Discover the Difference

Similar documents
Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

DALAMATIC DUST COLLECTORS

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

Advanced Technology High-Ratio Pulse Jet Baghouse Dust Collectors

LP BAGHOUSE DUST COLLECTORS

Introduction Airflow and filtration area General design practices Cleaning system

Modular Baghouse Dust Collectors

Filter cleaning in hot gas applications PENTAIR 1

Pneumatic Vacuum Conveying: an Easy Clean, Efficient, and Safe Mode of Transfer for Difficult or Harmful Pharmaceutical Powders

[1] Lecture 2 Particulate emission control by mechanical separation & wet gas scrubbing

TubeJet Dust Collector Application Guide. Top or Side Bag Removal Rectangular Cylindrical Low or High Pressure

S_Series Click to go to the page. S-Series Bag Filter

Kice Dust Control System Design and Maintenance Basics Design, Maintenance, & Operation

Schenck Process is Your Explosion Protection Resource Center

Specifying a Dust Collector For a School Wood Shop

DUST AND FUME COLLECTOR FOR THERMAL CUTTING AND WELDING APPLICATIONS

Dust Collectors. Unique Design & Engineering Approaches for Dust Collection and Pneumatic Conveying

general brochure

ASR. Automatic Scrap Recycling Systems

Traditionally, two design approaches have been commonly used for dust collection in float glass plants:

Combustible Dust Issues

FS flat bag dust collector

State-of-the-art Developments to Save Energy in Coating Drying

Air Pollution Control Equipment & Service Needs

COMPOSITE MESH PAD (CMP) DRY SCRUBBERS ENFORCER III TM III

airblastechtips Technical Tips for the Surface Treatment Industry

GOVE LDMY Extractor Series

CLEARING THE AIR by Jeremiah Wann, president and

ACT Cartridge Dust Collector

MJC Mini. Cartridge Filter. Features. Principal specification and options

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

In-Line Air Separators

WELD STRONG BREATHE FREE

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

50 Years of Quality. Specifying a Dust Collector For a School Wood Shop

HOW WELL DO YOU KNOW YOUR DUST?

PARTS DRYING & BLOW-OFF

Reducing the Cost and Risk of Dust Collection in Coal

Providing State-of-the-Art Fine Particulate Control Through Advanced High Energy Ionization

PLATE HEAT EXCHANGERS BETTER BY DESIGN

INDUSTRIAL REMOTE FILTER

Blasting Basics. Section H: Table of Contents. Blasting Basics: Cabinet Capabilities

Powder Technology Division. Niro. Fluidized Spray Dryer FSD

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

International PCT Patent Application No. PCT/GB2011/ Automag. Self-purging, fully automated magnetic filter

FAS-300 Central Dust Collection Systems

MCB SERIES. cross ventilation cartridge dust collector

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

Integrated System Selection and Design

Distributed By: M&M Control Service, Inc Building Technologies

T F E

HYDRONICS BY JOHN SIEGENTHALER

Product Selection Guide

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

Survey Says: Clean for Safety and Profitability

general brochure Abrasive blast rooms with Pneumatic The reference in surface treatment

HOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air

BURWELL CYCLONE BLAST CABINETS

MJC cartridge dust collector

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

EIMCO FlexKlear Inclined Plate Settlers Inclined Plate Settlers have a long-standing reputation as efficient water clarification tools with two unfort

Rotary Impingement Tank Cleaning Equals Significant Water and Cost Savings

Inffusers. idl20 (2 WAY) ids60 (4 WAY)

Capture Waste Heat with Ultra-High Efficiency

MODULAR HIGH CAPACITY REFRIGERATED AIR DRYERS. GMRN & GMRC Series

Cost, time and water savings gained through optimized tank cleaning

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

EXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series

ESN Screw Compressors kw 50 Hz

the condensate management specialist PURO-CT Sustainable Condensate Management CONDENSATE SEPARATORS

MJC Cartridge Filter Unit Operation & Maintenance

RC350. Glaston Flat Tempering

EV-PRO CONDENSATE SEPARATORS

High Performance Diesel Fueled Cabin Heater. Abstract

minibrs Toll Free: Compact, powerful system is comfortable, easy to use and requires no containment

The best technical solution for high powder concentrations High level filtering surface and compact design Heavy duty construction for long life in

M O D U L E IV C O N T R O L T E C H N I Q U E S

compressed air system?

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Air. Pressure. Motion. nnnnnnnn

Screw Compressors ESN Fixed Speed & VS 250 Variable Speed

general brochure The reference in sandblasting

DUST COLLECTION TRAINING. Revision 2013

Vacuum Conveying. Industrial Equipment & Design Company....a world of experience in powder handling

LITTLE BLASTER LARRY HESS AND ASSOCIATES, INC. BLAST-IT-ALL P.O. BOX 1615 SALISBURY, NC WITH DUST COLLECTOR

ROTARY DRYER CONSTRUCTION

NON-CYCLING REFRIGERATED AIR DRYERS. GSRN Series

Airblast Tech Tips Grit Recycling Systems - common questions and answers

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

Packed With Features. Smart Pulsar controls are conveniently

Dust Collection Tips to Keep Free-From Foods Safe from Cross-Contamination

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

APPLICA TION OF SPRA Y COOLED TECHNOLOGY TO A BOP SHOP FURNACE HOOD

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER

Gas-Fired Unit Heaters Commercial & Industrial

Transcription:

Discover the Difference In virtually every application, Scientific Dust Collectors are sized to operate at air-to-cloth ratios significantly higher than those required by less sophisticated dust collectors. In some cases, our airto-cloth ratio is as much as twice or even more than that of generic collectors using venture-based cleaning systems. This means Scientific Dust Collectors need only half, or less, of the filtering fabric area for a given air volume. Obviously, this difference in air-to-cloth ratios is dependent on the type of dust collected and the specifics of the dust collection application. At first glance it appears as though Scientific Dust Collectors is grossly undersizing the equipment. Nothing could be further than the truth. In fact, you are at greater risk of having problems with your dust collector if you choose one that has to increase the filter area to compensate for the poor performance of the cleaning system. Benefits of Superior Performance Very reliable dust collection using a more compact collector that saves space. Wide selection of fabric types for any dust application. Fewer bags, valves and cages to maintain. Less wear and tear on the filtering media. Lower system pressure drops. Ability to handle high dust loads without the need for a cyclone precleaner. Greater ability to recover should the bags become blinded due to dust surges, moisture, loss of compressed air or other unexpected interruptions that occur in real life. By using our superior cleaning technology, Scientific Dust Collectors offers price competitive dust collectors without having to resort to cost cutting elimination of valued constructional features, quality and the attention to detail we believe you deserve. Benefits of Quality Construction Wide variety of dust collector types to choose from; full collectors, top bag removal, bottom bag removal, bin vents, inserts and special designs. Thicker tubesheets to avoid warping which can cause leakage. Standard primer paint inside and out, enamel paint on exterior to avoid weathering. Standard flanged inlets and outlets for easy duct connections. Rain hoods over access door to prevent moisture problems. All welded construction for easier installation and a sturdier structure. Platforms and ladders designed per OSHA safety standards. Large, leak tested, compressed air headers to reduce load on air compressor.

Company Background Scientific Dust Collectors is an autonomous division of Venturedyne, Ltd., a large diversified industrial manufacturing corporation with divisions involved with dust collection, indoor air quality, environmental test chambers and sub-micron particle counting for clean rooms. All dust collector design, manufacturing, applications and sales support are done in one location providing close control over key aspects of our business. Scientific Dust Collectors began business in 1981 when our first patented improvement for cleaning a filtering media was issued. Subsequent patents were issued in 1986, 1987 and 1988 that relate to further improvements in dust collector cleaning technologies. In 1995 all operations of Scientific Dust Collectors were relocated to our current facility in Alsip, IL. The reasoning behind the move was to allow Scientific Dust Collectors more space to grow and reach its full potential. A major investment was made in new manufacturing and engineering design capabilities. Benefits of Working With a Sound Company All engineering and manufacturing is done at one location ensuring consistency, careful monitoring and precise quality control. Common service parts are stocked on site for accurate inventory and immediate shipment. Computer aided design and drafting means exacting documentation and the ability to make changes quickly with little impact. Readily available application assistance and responsive customer service. Significant investment in manufacturing equipment to ensure quality & accuracy. Knowledgeable, experienced and stable personnel guarantees future business continuity. Summary Scientific Dust Collectors approach to dust collection can be summarized by the following: To provide very reliable dust collection using more compact dust collectors. To maintain our competitiveness through the innovation in our superior cleaning system and proper dust collection techniques. To add the quality and value back into our dust collectors that our competition takes out in order to save costs. To allow our customers the flexibility to tailor our dust collectors to their needs. To provide responsive customer service.

The Proof is in the Performance The performance superiority of Scientific Dust Collectors is not just an idle claim. It is fact based on sound theory, solid engineering practices and extensive field experience. The sections which follow lay out the theories that are the basis for Scientific Dust Collectors superior performance. Comparisons are made between Generic Dust Collectors and Scientific Dust Collectors to highlight the important differences and the superiority of Scientific Dust Collectors. Characteristics of Air Jet Pulses Maximum possible air jet velocity at the discharge of a plain orifice, even under ideal conditions, is fixed at the speed of sound. Secondary air outside the air jet will be induced into the jet, expanding the jet volume and slowing the jet down. A higher velocity jet will induce a greater volume of air. An air jet discharged into free air that allows free induction of secondary air, will expand at an angle of 15 regardless of its velocity. Expansion of the air jet will be constrained if the induced air can be limited from entering the jet. The air jet velocity will be maintained for a longer distance when expansion is constrained. The velocity of the cleaning air jet going into the bag must be great enough to overcome the velocity of the filtered air coming out of the bag. Generic Pulse Jet Cleaning If the air jet is allowed to expand freely as it enters the throat of the filter bags, the velocity of the air jet will decrease to the point where it is not strong enough to overcome the filtered air upward velocity and only the top few feet of the bags will be cleaned unless air jet expansion is constrained. By stopping the induction of secondary air, and therefore limiting the expansion of the air jet, the jet velocity stays high allowing the air jet to reach the bottom of the bag with a sufficient velocity. Generic pulse jet cleaning systems use a so called venturi to stop the induction of secondary air. Their venturi does not act to induce more cleaning air, in fact, the venturi limits the induction of secondary air. That is its purpose. In a typical generic collector the diameter of the venturi throat is 1-3/4". The filtered air velocity through the venturi, which must be overcome by the cleaning air jet, is high due to this small venturi area.

The Scientific Dust Collector Difference Scientific Dust Collectors use a patented high velocity converging/diverging nozzle, instead of the plain orifice used by generics, to generate our cleaning air jet. The nozzle geometry produces air jet velocities much greater than is possible with a plain orifice. A much greater volume of secondary cleaning air is induced by this increased air jet velocity. As with the generic system, Scientific Dust Collectors also stops the induction of secondary air to limit the expansion of the air jet. However, instead of using a flow restricting venturi, we use the whole open area of the bag mouth to limit the secondary air induction. The larger area of the bag opening reduces the filtered air velocity coming up and out of the bag. Less cleaning energy is wasted overcoming a high filtered air velocity. Comparison of Generic vs. Scientific Dust Collectors Cleaning Systems The comparison below assumes the only difference between dust collectors is the method of pulse jet cleaning, venturi vs. nozzle, and the air-to-cloth ratio used. Scientific Dust Collectors is operating at twice the air-to-cloth of the generic system which is quite common in actual field practice. Generic System Scientific Dust Collectors Bag Length 8' 8' Bag Diameter 4-1/2" 4-1/2" Bag Fabric Area 9.46 ft² 9.46 ft² Air-To-Cloth Ratio 5:1 10:1 Filtered Air Volume per Bag (5)(9.46) = 47.3 CFM (10)(9.46) = 94.6 CFM Bag/Venturi Throat Diameter 1-3/4" at venturi 4-1/2" at bag opening Bag/Venturi Throat Area Filtered Air Velocity at Bag/Venturi Throat Opening Cleaning Air Jet Velocity at Bag/Venturi Throat Opening π(1-3/4)² = 0.0167 ft² (4)(144) π(4-1/2)² = 0.1104 ft² (4)(144) 47.3 0.0167 = 2,832 fpm 94.6 0.1104 = 857 fpm Higher Velocity Lower Volume Lower Velocity Higher Volume As the above calculations show, in the generic system the cleaning air jet must overcome 2,832 fpm, a much higher filtered air velocity, even though the air volume per bag is only half that of the volume run through the Scientific Dust Collector bag. The energy required to overcome the high filtered air velocity in the generic system is not available to clean the built up dust cake off the fabric bag. Additionally, there are other problems associated with the generic system that increase bag wear and cause an uneven dust cake to build up, thus reducing the efficiency of the generic collector and increasing the pressure drop of the system.

Generic Cleaning System The high filtered air velocity through the venturi must be overcome by the cleaning air jet, robbing it of energy to clean the bag. A lower volume of secondary air is induced by the slower cleaning air jet. There is less energy available to clean the bag. The high velocity of the cleaning air at the discharge of the venturi creates a greater negative pressure at the top of the fabric bag. Dust fines are more apt to embed into the fabric blinding the bag in this area reducing the effective filter area of the bag. Higher negative pressure at the top of the bag causes premature bag wear and dust migration thru the bag during each cleaning cycle as fine dust is sucked into the bag. As the air jet expands inside the bag it can impinge upon the filtering media causing dust cake blowout. Once dust cake blowout occurs, the cleaning pressure in the bag is relieved prematurely, thus reducing the cleaning effectiveness. The Scientific Dust Collector Difference Much greater amount of secondary air is induced by the higher velocity air jet. More energy is available for cleaning. Lower throat velocity at the inlet of the bag does not add to the negative pressure on the outside of the bag that causes dust to then migrate and blind the top section of the bag. More even bag inflation pressure from top to bottom of the bag causes less wear and tear on the bags. Less chance for dust cake blowout to occur since the cleaning air jet is already expanded to the full diameter of the bag. Dust cake is more even and it is less densely packed providing higher filtering efficiencies at lower pressure drops. Scientific Dust Collectors makes better use of the available filtering media.

Downward Air Pattern and Low Can Velocities Improve Dust Collection Dust naturally wants to fall down out of an air stream due to gravity. That is, unless the air stream is directed upward at a high enough velocity to re-entrain the dust particles. Scientific Dust Collector housings, with high side inlets, are designed so as to promote downward air movement and to reduce the can velocity. Below is an example of two dust collectors, a generic collector and a Scientific Dust Collector, showing the effects of a high side inlet. Though the Scientific Dust Collector uses only half the cloth area, our enclosures are very liberally sized, yielding a slightly smaller footprint than that of the generic. Generic Dust Collector @ 5:1 A/C Scientific Dust Collectors @ 10:1 A/C 6,800 CFM @ 5:1 air-to-cloth 6,800 CFM @ 10:1 air-to-cloth 144 bags, 8' long, 4-1/2" dia. 72 bags, 8' long, 4-1/2" dia. 1,362 ft² total fabric area 681 ft² total fabric area Bag enclosure: 80" W x 80" D x 102" H Bag enclosure: 65" W x 92" D x 102" H Projected Interstitial Area: (80" x 80") _ (144)π(4.5)² = 28.5 ft² Projected Interstitial Area: (65" x 92") _ (72)π(4.5)² = 33.6 ft² 144 (144)(4) 144 (144)(4) Can Velocity = 6,800 cfm 28.5 ft² = 239 fpm Can Velocity = 6,800 cfm 33.6 ft² = 202 fpm Scientific Dust Collectors baffled high side inlet, an expensive option for others, allows dust laden air to flow down and across the filter bags so dust is directed down into the hopper. Scientific Dust Collector bags are spaced on 7-1/2" centers leaving a generous 3" spacing between bags. Generic collectors often have only a little more than 2" spacing between bags. Wide bag spacing helps to keep material from bridging between bags or hopping from row to row as each successive row of bags is pulse cleaned. The Scientific Dust Collectors Difference Now you know the Scientific Dust Collector difference. Not all dust collectors are created equal! Please do not group us with the many generic dust collectors on the market today that require more cloth area to overcome their poorer performance. Why settle for less when a more sophisticated alternative is available to you.