O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

Similar documents
O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

DELI MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK. Featuring. Technology P902077H. Rev 4 1/07 COMPONENT

DELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION

OWIZ/OWIZV OWEZ/OWEZV

REAR LOAD DAIRY INSTALLATION & OPERATION HANDBOOK P056170D. Rev /10 COMPONENT

3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT

RM with INNOVATOR Doors

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

MULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL. Table of Contents

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

DELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT

QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

ISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

RL with INNOVATOR II No Heat Doors

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

Nosing Heater. Return Grill Heater

ORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

RLT with INNOVATOR Doors

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _F NSF Certified June 2010

FG-L Technical Data Sheet

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

Engineering Plan Views

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

IMPORTANT KEEP IN STORE FOR FUTURE USE

QDV5V - 1 Door Standard (Gemtron)

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

RLNIE with INNOVATOR II

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

INSTALLATION & OPERATION MANUAL

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

PWEE Technical Data Sheet

INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE

Installation & Service Manual

ORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX...

INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

RMN with INNOVATOR Doors Technical Data Sheet

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

QC BEVERAGE/DAIRY/DELI

Energy Efficient. Flexible Design Options.

Case Study of Adding Glass Doors to Multi-Deck Meat Case

Low Flow Unit Coolers

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

QM5, QM5G Multi-Deck Meat Display Case. Part Number: 31E03028 Date: 08/13/2007

Unico Training. Class for R E Michel Salesmen

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

Installation & Service Manual

Installation & Service Manual

HVI-4-406R/HVI-4-408R

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

DAIRY/DELI PRODUCE C A S E S O5DMA INSTALLATION & OPERATION HANDBOOK. P056442G Rev /13

INSTALLATION and OPERATION INSTRUCTIONS

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

CDC-R & CDC-D BAKERY MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

MODEL RD-8 Self Contained MODEL RD-2

Center Mount Unit Coolers

S2SGC MEAT/SEAFOOD MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Unico Training. Welcome to Unico!

NFW, NCW, NFWG, NCWG, NFWE, NCWE

SERVICING SUPERMARKET REFRIGERATION EQUIPMENT By: Kenneth S. Franklin National Service Manager Hussmann Refrigeration, Inc.

INSTALLATION and OPERATION INSTRUCTIONS

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Transcription:

GENERAL NOTES "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. SHIPPING WEIGHT Case --- Weight

ELECTRICAL DATA Case Fans Per High Efficiency Fans 120 Volt Length Case Amps Watts 4' 2 0.46 36.0 6' 4 0.94 70.0 8' 4 0.94 70.0 12' 6 1.40 106.0 LIGHTING DATA Case Length Lights per row Clearvoyant v4 LED Lighting (Per Light Row) Standard Power High Power (Cornice or Shelf) (Cornice Only) 120 Volts 120 Volts Amps Watts Amps Watts 4' 1 0.05 5.9 0.12 14.9 6' 2 0.08 9.4 0.20 23.8 8' 2 0.10 11.8 0.25 29.9 12' 3 0.15 17.6 0.37 44.8 GUIDELINES AND CONTROL SETTINGS BTUH/ft Superheat Set Conventional Parallel Point @ Bulb ( F) Evaporator ( F) Discharge Air ( F) Discharge Air Velocity (FPM) 1646 1440 6-8 26 30 270 DEFROST CONTROLS Timed-Off Defrost Defrosts Per Day Fail-Safe 6 40 47 "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. Listed BTUH/ft data represent unlighted shelves. For LED lighting, add 9 BTUH/ft per row of lighted shelving. BTUH load increases by 132 BTUH/ft when aftermarket merchandising accessories are utilized. isted evaporator temperature represents unlighted shelves. For lighted shelves and/or aftermarket merchandising accessories, reduce the listed evaporator temperature by 2 F. Conventional Discharge Air Control Recommended Settings: Cut-In Temp = Discharge Air + 2 F; Cut-Out Temp = Discharge Air - 2 F. Listed discharge air velocity represents the average velocity immediately after defrost. Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommended evaporator temperature is 4 F below the listed evaporator temperature.

SECOND NATURE DATA BTUH/ft (DR) Supply Fluid Discharge Air Temp (F) Case Model Coils Application Front Sill Type Conventional Parallel GPM/ft (DR) 1 Meat 6" Thermopane 1646 1440 0.42 20 30 1 Meat 6" Thermopane 1646 1440 0.99 25 30 SECOND NATURE DATA Timed Off Defrost Warm Fluid Defrost Case Model Coils Application Front Sill Type Defrost Fail Safe Fail Safe 1 Meat 6" Thermopane 6 60 47 26 49 1 Meat 6" Thermopane 6 45 42 26 49

CORNICE OPTIONS CURVED CORNICE CURVED CORNICE FACETED CORNICE FACETED CORNICE WITH NIGHT COVER WITH NIGHT COVER 39 5/8" 42 7/8" 39 1/2" 42 3/4" FLAT CORNICE 38 3/4" 41 3/8" FLAT CORNICE WITH WITH STANDARD NIGHT COVER FRONT OPTIONS FLAT FRONT 2 FLAT FRONT CLASSIC 2 METAL CLASSIC 2 POLYMER THERMOPANE ORIGIN 2 6" THERMOPANE FRONT 19 7/8" [50.5 cm] 29 7/8" [75.8 cm] 22 3/8" [56.9 cm] 4" THERMOPANE FRONT 27 7/8" [70.8 cm] 25" [63.5 cm] 4" THERMOPANE FRONT W/T NOSE LIGHT 27 7/8" [70.8 cm] 29 7/8" [75.9 cm] 26 3/16" [66.6 cm] 26 3/16" [66.6 cm] 26 3/16" [66.6 cm] 26 3/16" [66.6 cm] 27 3/8" [69.6 cm] 6" THERMOPANE FRONT Front sill and overall case height varies with base frame height.

OPTIONAL WIRING TO THE TOP 12 in X 10 in X 4 in 39 5/8" [100.6 cm] 91 1/8" [231.4 cm] SHIPPING HEIGHT 88 7/8" [225.7 cm] OVERALL CASE HEIGHT 85 5/8" [217.5 cm] CASE HEIGHT 63" [160.0 cm] INTERIOR HEIGHT 1 32 1/4" [81.9 cm] OPTIONAL DISCHARGE PLEXI DEFLECTOR LOAD LIMIT 54 7/8" [139.4 cm] VISUAL DISPLAY COIL PLENUM 5 1/8" [13.0 cm] 6 3/8" [16.2 cm] 31 3/4" [80.6 cm] 38 7/8" [98.7 cm] 19 3/8" [49.2 cm] 29 3/4" [75.5 cm] 42 7/16" [107.8 cm] 12" [30.5 cm] WIRING TO THE TOP (OPTIONAL) 2" MINIMUM AIR GAP PIPING TO THE TOP (OPTIONAL) REAR REFRIGERATION LOCATED 14 1/2" ABOVE FINISH FLOOR 43 1/8" [109.5 cm] 38 7/8" [98.7 cm] 31 3/4" [80.6 cm] 29 1/8" [74.1 cm]* 3" [7.6 cm] 28 5/8" [72.7 cm] 35 15/16" [91.2 cm]** ELECTRICAL JUNCTION BOX 1 1/2" PVC DRAIN CONNECTION DEFAULT REFRIGERATION 1 1/2" [3.8 cm] {END} 48" [121.9 cm] 72" [182.9 cm] 96" [243.8 cm] 144" [365.8 cm] 8 3/4" [22.2 cm] * :STUB-UP AREA ** :RECOMMENDED STUP-UP CENTERLINE FOR ELECTRICAL AND DRAINS 1 :AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18", 20", 22" & 24" Ends add approximately 1" to case height, 1/2" to the back & 1" to the front. Back panels add approximately 1" to the rear of the case.