Procenter Delivery Systems. [Includes: Delivery Units and Assistant s Units (All Styles)] (no serial numbers on Assistant s Units)

Similar documents
Artizan Ortho-Pedo Bench Installation / User Manual

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-10 AseptiMini Pneumatic Portable Dental System

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

Sound Cover [ , , , ]

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-17A Express Air Portable Dental System

MODEL 7000 SUCTION UNIT

Table of Contents. English

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-17X2 Express Plus II Portable Dental System

Use and Care Guide. Over the Patient Units and Swing Mount Units

A-dec 300 Support Systems

SAVE THESE INSTRUCTIONS

INSTRUCTIONS FOR OPERATION AND CARE OF

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

222 / 223 Barrier-Free Examination Table

USER MANUAL SAVE THESE INSTRUCTIONS

Industrial Vacuums, Inc

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Owner & Operator Manual

PowerVac G Single to Twin Conversion Kit [ ]

Dental Unit User's Guide

X99 Series. Dental Handpiece. Instruction For Use

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Owner & Operator Manual

OPERATION AND MAINTENANCE MANUAL

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

MaxiCompressor. evo. High Performance 50 PSI Compressor TH PLACE ADEL, IOWA 50003

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install

USER S OPERATING AND INSTRUCTION MANUAL

Xaact Spot. Xaact Hot Spot

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Instructions for Use. A-dec 461 Cuspidor with Support Center

OPERATING INSTRUCTIONS

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Ui REFRIGERATOR SPEC SHEET

OPERATING INSTRUCTIONS

Syclone Amalgam Separator Installation and operating guide

ASPIRE Laboratory Aspirator

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Integra Ultrasonic Tooth Scaler

TrueClean ToteCleaner

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

Cool Mist Ultrasonic Humidifier

MODEL HBX-1 P/N 3G59332

OPERATIONS MAINTENANCE MANUAL

SpeedClave Steam Sterilizers

Installation Instructions PP-AS20 Anti-Scale System

Printed in U.S.A Rev. A 6/2005 0B

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

VetPro Solo Installation

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

InstructIons for use A-dec 561 Cuspidor

Wax Base Heater & Dispenser

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Instruction Manual. Cheese Warmer with Pump

INSTRUCTIONS FOR OPERATION AND CARE OF

User s Manual and Operating Instructions

Ultrasonic Cool Mist Humidifier

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-425 Transport II Portable Dental System

Installation & Operation Manual Ice Cream Freezers

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

IMpORTANT SAFETy INSTRUcTIONS

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Garment Steamer Model SC620

AUTOMATIC STERILIZERS

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

20 High velocity Air

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

18 INCHES, OSCILLATING STAND FAN

Instructions for Use A-dec Self-Contained Water System

Instruction Manual for Meat Grinder XMCA-SS

TrueClean ToteCleaner

Outdoor/Commercial Refrigerator USER S MANUAL

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

Outdoor Refrigerator USER S MANUAL

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Single Handle Lavatory Faucet

Easy Vac BAGLESS VACUUM

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

User Manual. Please read this User Manual and the Safety Information before operating the Soda Maker.

Hg5 Amalgam Separator Installation and Operations Manual

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

30 Misting/Oscillating Fan Model Number 01030

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

Transcription:

User Guide Procenter Delivery Systems [Includes: Delivery Units and Assistant s Units (All Styles)] Serial Number Locations DA259601i Procenter Delivery Unit Cabinet Mounted Units Assistant s Unit Compact Assistant s Unit (no serial numbers on Assistant s Units) Note Work surface shapes may vary per cabinet, your exact shape may not be shown. Control knobs and adjustments remain the same, or similar, for all units. Serial Number Location Intended Use... 2 Electromagnetic Interference... 2 Disposal of Equipment... 2 Transportation / Storage / Operating Conditions... 2 Authorized EU Representative... 2 Calling for Service... 2 Symbols... 3 Work Surface Weight Limit... 4 Self-Contained Water System... 4 Manual Shut-Off Valves for Air and Water Supply... 5 Pressure Regulator Valves... 5 Master ON / OFF Switch... 6 Water Selector Switch... 7 Flex Arm (Lock / Unlock)... 8 Quick-Connect Ports... 9 HVE / Saliva Ejectors... 10 Operating Handpieces...11 Handpiece Controls... 12 Syringe Operation & Adjustments... 13 Adjustment Knob Location... 14-16 Cleaning & Maintenance... 17-23 Specifications... 24 Replacement Parts... 24 Warranty Information... 25 Technical Library at Midmark.com Language of origin: English 1 Part No. 003-1261-00 Rev. V (9/9/15)

Compliance Information and Symbols Intended Use Midmark delivery systems are intended to provide dental professionals with air, water and suction to operate dental handpieces, syringes, and Midmark authorized accessories during dental examinations and procedures. Electromagnetic Interference Midmark dental operatory components are designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and this operatory, remove the interfering device from room and / or plug product into an isolated circuit. Transportation / Storage / Operating Conditions Transportation / Storage Temperature:...23 F to 100 F (-5 C to 38 C) Relative Humidity:... 10% to 90% (non-condensing) Atmospheric Pressure:... 7.2 PSI to 15.3 PSI (50 kpa to 106 kpa) Operating Temperature Range:...59 F to 95 F (15 C to 35 C) Authorized EU Representative Countries in the EU should direct all questions, incidents, and complaints to Midmark s Authorized EU representative listed below. Calling For Service Midmark EMEA Ltd Beech House First Floor, East Wing Ancells Business Park Fleet Hampshire GU51 2UN United Kingdom Tel: + 44 (0) 1252 360 940 Fax: + 44 (0) 1252 360 941 Direct all service inquiries to your authorized Midmark dealer. When calling for service, you must provide the following information: Model / serial number Date of purchase Symptom(s) of malfunction Disposal of Equipment At the end of this product s life, the unit, accessories and other consumable goods may be contaminated from normal use. Consult local codes and ordinances for proper disposal of this equipment and other consumable goods. warning Do not modify this equipment without authorization of the manufacturer. Caution Federal law restricts this device to sale by or on the order of a licensed dental practitioner. 2

Symbols These symbols may appear on your equipment and/or in the manuals. Warnings and cautions are provided in the manuals where applicable. warning Indicates a potentially hazardous situation which could result in serious injury if not avoided. Type B, Applied Part Consult Manuals Caution Indicates a potentially hazardous situation which may result in minor or moderate injury if not avoided. It may also be used to alert against unsafe practices Type BF, Applied Part Protective Earth Ground 23 F -5 C 100 F 38 C Pressure Limit Temperature Limit Equipment Alert Indicates a potentially hazardous situation which could result in equipment damage if not avoided. Proper Shipping Orientation Humidity Limit NOTE Amplifies a procedure, practice, or condition. Fragile Maximum stacking height (Refer to n number on package.) Keep Dry 3

Product Features Work Surface Weight Limit Caution Exceeding the design weight limit may result in personal injury or damage the equipment. Maximum load on Flex Arm mounted units is 7 lbs (3.2 KG) Self-Contained Water System The Self-Contained Water System gives you control of the quality of water used in your delivery system. It also provides a means for cleaning the system s internal tubing. Caution Residual air pressure may cause the water bottle to pop off and spill or spray the contents if not released. Mounting Cap Before you begin filling the water system... A) Turn master switch OFF.. B) Press syringe air button and hold until all residual air pressure is expelled. (You can hear the air being expelled.) 2 3 4 1 Gasket DA2075 NOTE Distilled water is not required. Water used must meet all local requirements for drinking water. DA24701i To fill the Self-Contained Water System bottle... A) Unscrew water bottle. B) Fill bottle with water. C) Be sure Gasket is in place (in Mounting Cap). D) Screw bottle into Mounting Cap. Maximum load for cabinet mounted arms is 40 lbs (18 KG) DA101201i Note: If Gasket is improperly sealed, you will hear a hissing noise when the system is turned ON. 4

0 80 80 Manual Shut-Off Valves for Water and Air Supply Manual shut-off valves allow you to stop the air and/or water supply at the point of input to the operatory. This is recommended during extended periods of non-use (ex. vacation, holidays, etc.), or in the event of an equipment malfunction. Pressure Regulator Valves Pressure regulator valves allow you to control the air and water pressure supplied to the instruments of the delivery. City Water Gauge City Water Regulator Adjustment Knob Shut-off Valves Rotate clockwise 1/4 turn to Shut off. Air Regulator Adjustment Knob Water Manual Shut-off Valve 20 40 3 2 1 0 60 4 5 6 7 100 To Adjust the Pressure Regulators... A) Pull up knob and turn to adjust. B) Watch regulator gauge as you turn knob to achieve desired setting C) Push knob DOWN to lock. Air Regulator Gauge Recommended Settings: City Water Regulator Gauge Setting Air Pressure Regulator Gauge Setting 30 psi Air Manual Shut-off Valve 80 psi Equipment Alert Delivery components were designed to operate at the recommended settings. Poor performance or damage to the equipment may result if recommended settings are not maintained. Turn Clockwise for more pressure Turn Counter-Clockwise for less pressure 0 4 7 5 6 100 DA3820i 5

Master ON / OFF Switch The Master ON / OFF Switch must be ON to operate the delivery system. To turn the Delivery System ON or OFF... Move the Master Switch to the desired position. 2 3 4 1 DA24701i DA2075 SLIDE SLIDE O I OFF ON OFF Position returns to center ON Position DA2075_a 6

Water Selector Switch The Water Selector Switch allows you to choose the water source for the delivery system. You may select either City Water (tap water), or water from the Self-Contained System s water bottle. To select a water source... Toggle the switch to select the desired water source. City Water Self-Contained System Water Bottle DA229401i 7

Flex Arm (Lock / Unlock) A lock mechanism exists on the Flex Arm to prevent unexpected downward movement, which could result in injury to the patient or staff. The Master Switch must be ON for the air-powered Flex Arm lock to work. The Flex Arm can still be raised upwards when locked. Procenter Units To set the Flex Arm lock to a new height... A) Press and hold either Lock/Unlock Button. B) Raise flex arm slightly (to disengage the lock). C) Lower to desired height. D) Release the Lock/Unlock Button to engage the lock. Lock/Unlock Buttons 2 3 4 1 8

Quick-Connect Ports Quick-Connect Ports (air [yellow] and water [blue]) allow you to quickly connect accessories to the delivery system. Each Quick-Connect Port has a hinged clip that securely affixes the connecting line to a raised ring found on each port opening. Air Water Water ONLY (standard) Air (optional) Air Water DA229602i 9

HVE and Saliva Ejectors Before you begin... A) Turn facility vacuum system ON. B) Move lever to towards the OPEN position to activate and moderate suction for the HVE / Saliva Ejector. Closed Closed Open Open DA2308i HVE Saliva Ejector 10

Operation and Adjustments Operating Handpieces Handpieces can deliver water and air dependant on the setting of the Water Selector footswitch. To Operate handpiece... A) Turn Master Switch ON B) Move Water Selector Switch to desired setting. C) Remove handpiece from holder. D) Press foot pedal to deliver the selected drive air/water to the handpiece. Handpiece Blue Dot indicates Water Selection Water Selector Switch Da100202i 11

Handpiece Controls Each handpiece has its own Drive Air control knob and its own Coolant Water control knob. There is also a Coolant Air control knob that adjusts the coolant air for all handpieces. To adjust the Coolant Water... Rotate the Coolant Water control knob for the desired handpiece, until the desired flow is achieved. To adjust the Drive Air pressure... Rotate the Drive Air control knob for the desired handpiece, until the desired air pressure registers on the pressure gauge. Note: Refer to the handpiece manufacturer s literature for the recommended pressure setting. To adjust the air/water Spray Pattern... Rotate the Coolant Air control knob until the desired pattern is achieved. Note: If your handpiece has an internal coolant air connection this adjustment will have no effect. 12

Syringe Operation and Adjustments This page shows operation and adjustment for a standard 3-way syringe. Before you begin... A) Turn the Master Switch ON. B) Position the Water Selector Switch to Water or Air. Blue Dot indicates Water Selection Water Selector Switch Press Water Button for a Water Stream Press Air Button for an Air Stream To Adjust the Air Spray pressure and Water Spray pattern... Rotate the syringe Air control knob as desired. Press Air and Water Buttons for a Water/Air Mist Spray To Adjust the Water stream pressure and Water Spray pattern... Rotate the syringe Water control knob as desired. Syringe Water control knob Syringe Air control knob DA2595i 13

Adjustment Knob Location ProCenter Delivery Units Coolant Air Coolant Water Syringe Air Syringe Water Drive Air Pressure Gauge for the Drive Air 2 3 4 1 To access the control knobs... A) Use a screwdriver to rotate the lock screw on the panel access button. B) Press the panel access button and lift top section. Lock Screw Note: The lock screw prevents the panel access button from being pressed when it is rotated to the lock position. 14

Adjustment Knob Location - continued... Assistant s Units The Assistant s units have screw-type control knobs to adjust the air and water flow to the syringe. Control knobs Syringe Air Syringe Water DA2303 15

Adjustment Knob Location - continued... Cabinet Mounted Units Syringe Air Syringe Water Pressure Gauge (Drive Air) Syringe Water Knob Coolant Water Knob Coolant Air Knob Syringe Air Knob Drive Air Knob Ka998503 16

Cleaning, Disinfecting and Maintenance Barriers Midmark recommends the use of disposable barriers on all clinician controls that may be in contact with clinician hands and fingers during dental procedures. The use of barriers significantly reduces the need for chemical cleaners, thus prolonging the life of the equipment. Only use barrier material that is intended for use with dental equipment. Midmark recommends the use of an FDA market-cleared barrier such as Pinnacle Cover-all. Follow barrier manufacturer instructions for proper use of these products. Cleaning and Disinfecting In addition to the use of barriers Midmark recommends the use of an EPA registered and FDA market-cleared cleaner/disinfectant such as Cavicide to be used on all clinician controls or surfaces that may come in contact with dental instruments during dental procedures. General Purpose Cleaning For general purpose cleaning, use cleaners that are appropriate for the situation, such as warm water and mild detergents, or a 10% solution of bleach with water. Visual Inspection After cleaning, visually inspect the product for deterioration of covers and touch pads. Do not use the delivery system if excessive discoloration, cracking, or other signs of wear are noticeable (see Calling for Service instructions). Cleaning and Disinfecting Assistance For assistance with cleaning and disinfecting instructions contact the Midmark Technical Service Department at 1-800-Midmark, it is helpful to provide the delivery system model number and serial number when asking for assistance. Follow cleaner/disinfectant manufacturer instructions for proper use of the product. Care should be taken to avoid excessive application and pooling of liquids. Read all labels carefully! Additional information is available from the organizations listed below: Organization for Safety & Asepsis Procedures: http://www.osap.org Handpiece Accessories Only use dental handpiece accessories with the delivery system that are FDA market-cleared and refer to manufacturer s instructions for proper cleaning and disinfecting. Either an autoclavable syringe tip or a single use disposable syringe tip may be used. Equipment Alert AUTOCLAVABLE SYRINGE TIP STERILIZATION The autoclavable syringe tips supplied with the delivery system must be sterilized prior to use with each patient, including initial use. Be sure to thoroughly rinse and clean syringe tips prior to sterilization, any debris may reduce the effectiveness of the sterilization. Recommended sterilization process is steam autoclave. Recommended parameters are 125 C (250 F) and 106 kpa (15 PSI) for 40 minutes at temperature and pressure. American Dental Association: http://www.ada.org Dept. of Health & Human Resources Centers for Disease Control & Prevention (CDC): http://www.cdc.gov European Dental Association: http://www.eda-eu.org 17

Cleaning the Delivery System At the beginning of each day... Fill the Self contained water bottle with fresh water and perform a Purging Procedure. Note: See Purging Procedure described in this manual. DA101201i Note: Water must be safe for drinking. Distilled water is not required. Procenter Units For each new patient... Replace disposable tips, instruments, etc. and perform a Purging Procedure. Note: See Purging Procedure described in this manual. DA2536i 18

Cleaning the Delivery System - At the end of each day... A) Remove disposable tips, instruments, etc. B) Mix approximately 10% bleach (use only 5.25% bleach solution) with 90% water. Note: Use fill marks on the newer Midmark water bottles for quick measures.. Note: Use only 5.25% Bleach Solution. Do not use bleach with scents, color guards, or other additives. Mix fresh every day. DA2536i C) Perform a purging procedure. Leave the bleach mixture in the system for 10-20 minutes, then remove. Empty and rinse the water bottle Note: See Purging Procedure described in this manual. ~90% ~10% D) Fill the water bottle with fresh water and perform a purging procedure. Repeat as many times as needed, until all the bleach odor is gone. Equipment Alert Do not leave bleach mixture in system longer than 30 minutes. Doing so may damage the delivery system. E) Turn Master Switch OFF. Press and hold the foot control pedal until all pressure is released. DA2538i 19

Purging Procedure for the Delivery NOTE: The purging procedure removes debris from the tubing to the handpieces and syringe. Performing this procedure frequently may help reduce the accumulation of biofilm on your instruments. To begin the purging procedure... A) Turn Master Switch ON. B) Turn Water Selector Switch to bottle setting C) Move the foot control switch to the water setting. D) Disconnect handpiece from tubing. Flush the tubing to the handpieces... A) Press and hold the foot control pedal for 30 seconds. B) Press and hold the flush button for 30 seconds. C) Repeat for all tubing to the handpieces. SLIDE ON Position Flush Buttons Water Selector Switch Water Caution Hold the tubing and syringe over a container or drain while flushing. Flush the Syringe Tubing... A) Press and hold both syringe buttons (air and water) for 30 seconds. Foot Control Switch 20 DA255901i

Air/Oil Separator - Cleaning and Maintaining Periodically check the fluid level in the air / oil separator container. When the container is approximately 2/3 full, clean the air/oil separator as shown below. To clean the air/oil separator... A) Turn master ON/Off switch Off. B) Remove (unscrew) air/oil separator container. C) Dispose of the fluid and saturated gauze. D) Clean container and mounting cap. E) Install clean gauze and reinstall the container. 21

20 40 0 2 1 3 0 4 60 5 6 7 80 100 Maintaining and Replacing the Regulator Filters Step 1: Shut off manual valves to turn off water and air supplies to the operatory. Manual Shut Off Valves Step 3: Unscrew retainer nut and remove filter. Retainer Nut Filter Step 4: Install new filter. Secure with retainer nut. Note: Install the filter & retainer nut with the ridged side up (as shown). Filter Cap Step 2: Unscrew filter cap. Note: Use 9/16 wrench. Step 5: Reinstall filter cap. 22

Assistant s Units - Cleaning To clean the facility vacuum system... Refer to the instructions provided by the vacuum system s manufacturer. Note: Every dental practice is different, and no single cleaner is the best choice for every facility. See the list of organizations that may assist you in choosing the best cleaners available for your practice, in the front of this manual. Lid Basket Housing To clean the solids collector... A) Turn facility vacuum OFF. B) Remove lid and basket. C) Clean basket and housing. D) Reinstall basket and lid. Lid Basket Caution Always dispose of biohazardous debris according to local regulations. Housing DA147102i 23

Specifications Electrical Rating for Elevance and Midmark Ultra Chair: Complies to the applicable requirements of: Power Supply Model No.: 153808-001, -002 ES/IEC/EN 60601-1, CAN/CSA C22.2 No. 60601-1 (Safety Standards), EN/ IEC 60601-1-2 (EMC Standards) Replacement Parts These replacement parts can be purchased from your authorized Midmark dealer. Saliva Ejector Valve Part Number 029-3975-00 HVE Handpiece Valve Part Number 029-3974-00 Electrical Rating for Knight Chair: Complies to the applicable requirements of: Air Supply Requirements: Water Supply Requirements: Classifications: 24 VAC, 3.2 amp 13 VAC, 2 amp UL/IEC/EN 60601-1, CAN/CSA C22.2 No. 601.1, IEC 60601-1-1 Maximum 80-100 PSI (5.52-6.9 bar) Maximum 30-50 PSI (2.1-3.4 bar) Class I, Type B Applied Part, Ordinary Equipment (IPX0), Continuous Operation Solids Collector Basket Large Part Number 053-1106-00 Solids Collector Basket Small Part Number 118613 Saliva Ejector Tip Part Number 016-1116-00 Syringe Tip Part Number 120514 Regulator Valve Filter Part Number 053-1166-00 Certifications: Midmark Corporation...ISO-9001 Optional Accessories: Acteon Satelec Scaler Type B Applied Part Saliva Ejector Lever Part Number 016-1113-00 HVE Lever Part Number 016-1109-00 Acteon Satelec Curing Light Acteon Sopro Intra-oral Camera Type B Applied Part Type BF Applied Part DA2304-2 Bien AIr Electric Motor Dentsply Cavitron Scaler Type B Applied Part Type B Applied Part warning Equipment is not suitable for use in the presence of a flammable anesthetic mixture with oxygen, air, or nitrous oxide. Handpiece tubing and connectors intended to be used with ISO 7785-1 or ISO 7785-2 compliant air-driven handpieces Type B Applied Part 24 Clarification: Equipment is suitable for use in the presence of oxygen, air, or nitrous oxide.

Warranty Information SCOPE OF WARRANTY Midmark Corporation ( Midmark ) warrants to the original purchaser its Dental products and components (except for components not warranted under Exclusions ) manufactured by Midmark to be free from defects in material and workmanship under normal use and service. Midmark s obligation under this warranty is limited to the repair or replacement, at Midmark s option, of the parts or the products the defects of which are reported to Midmark within the applicable warranty period and which, upon examination by Midmark prove to be defective. APPLICABLE WARRANTY PERIOD The applicable warranty period, measured from the date of delivery to the original user, shall be as follows: 1. DENTAL PRODUCTS are warranted against defect in material and workmanship for the period indicated below from the time of delivery: (a) Two (2) years for all products and components (except for the periods in b thru e). (b) KINK-VALVE module carries a ten (10) year warranty. (c) The original light bulb on a new light carries a one (1) year warranty. (d) Accessories not manufactured by Midmark are excluded. (e) Replacement parts and accessories carry a ninety (90) day warranty. 2. Oral Surgery PRODUCTS are warranted against defect in material and workmanship for a period of one (1) year from the time of delivery. 3. STERILIZERS PRODUCTS are warranted against defect in material and workmanship for a period of one (1) year from the time of delivery. 4. ULTRASONIC CLEANER PRODUCTS when used in accordance with manufacturer s instructions and under normal use, are guaranteed for two (2) years after date of shipment. Within the period guaranteed, the manufacturer will repair or replace free of charge, at its sole discretion, all parts that are defective because of material or workmanship including costs for removing or installing parts. Repairs are made on a FOB repair depot basis. Manufacturer s liability, whether based on warranty, negligence or other cause, arising out of and/or incidental to sale, use or operation of the transducer elements, or any part thereof, shall not in any case exceed the cost of repair or replacement of the defective equipment, and such repair or replacement shall be the exclusive remedy of the purchaser, and in no case shall manufacturer be responsible for any and/or all consequential or incidental damages including without limitation, and/or all consequential damages arising out of commercial losses. 25 5. INTEGRA DENTAL CASEWORK AND ARTIZAN DENTAL FURNITURE PRODUCTS are warranted against defect in material and workmanship for the period indicated below from the time of delivery: (a) Five (5) years for all products and components (except for the shorter periods in (b and c), including plastic laminate top surfaces, door and drawer fronts, casters, and electrical components such as task lights and cords. (b) Three (3) years for task light ballast. (c) One year (1) for plastic laminate, solid surface countertops and accessories. EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following; (1) repairs and replacements because of misuse, abuse, negligence, alteration, accident, freight damage, or tampering; (2) matching of color, grain, or texture except to commercially acceptable standards; (3) changes in color caused by natural or artificial light; (4) products which are not installed, used, and properly cleaned as required in the Midmark Installation and or Installation/Operation Manual for this applicable product; (5) products considered to be of a consumable nature; (6) accessories or parts not manufactured by Midmark; (7) specially manufactured products; (8) charges by anyone for adjustments, repairs, replacement parts installation, or other work performed upon or in connection with such products which is not expressly authorized in writing in advance by Midmark. EXCLUSIVE REMEDY Midmark s only obligation under this warranty is the repair or replacement of defective parts. Midmark shall not be liable for any direct, special indirect, incidental, exemplary or consequential damages or delay including, but not limited to, damages for loss of profits or loss of use. NO AUTHORIZATION No person or firm is authorized to create for Midmark any other obligation or liability in connection with the products. THIS WARRANTY IS MIDMARK S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS.