PARVIS Safe and tranquil thanks to Parvis

Similar documents
INDEX. Installation recommendation

Perimeter protection

CONFIGURATION OF THE OPTICALS

INDICE. Installation recommendation

INDEX. Installation recommendation

DUAL OPTIC. Installation manual

INDEX. Installation recommendation

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

BARRIERE & SENSORI BARRIERS & SENSORS

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

BARRIERS & SENSORS Catalogue 2017

English. Series. Installation and Use Manual

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

Installation And commissioning manual. Series S Double Beam 1/16

ACTIVE INFRARED BARRIER

FSLIMPRO

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

Long-Range Barrier Sensors

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

Active Infrared Multi Beam Sensors

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Intrusion. Outdoor protection perimeter

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Active Infrared Multi Beam Sensors. R Series

Quick Selection Guide Intrusion Detectors

Photoelectric Beam Detector

INFRARED MODULATED BARRIERS

4040 FM 535 F :

"Pegaso" wireless alarm system

Twin Photobeam Detectors Manual

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

OPTICAL TURNSTILE SYSTEM

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

ADPRO PRO Series by Xtralis

JUNE 2014 SECURITY SYSTEMS

RLS-3060SH REDSCAN ULTIMATE

/ / 2018

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Intrusion Outdoor Protection Perimeter

>WIRELESS> ALARM SYSTEM CR200

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

RLS-3060SH REDSCAN ULTIMATE

User Detection Sensors

FIRERAY 5000 range USER GUIDE

PHOTOELECTRIC DETECTOR

THE BEST SOLUTIONS FOR OUTDOOR PERIMETER PROTECTIONS

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

Presented By. BEI Security

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

P E R I M E T E R m i n i c a t a l o g u e

Solar Powered Wireless Photobeam Sensors

Technical Manual. Level Alarm Unit CARLA & WIDS

Outline Specification: EDSUKMT1 MAN TRAP CYLI NDER GATE

ADPRO PRO Passive Infrared Detector. Webinar November Ben Klösen, PLM

ITALIAN SECURITY MANUFACTURER

Movement Detector GJD 300

2 General Application Photoelectric Sensors

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

CORPORATE PROFILE PERIMETER PROTECTION SYSTEMS

SEPTEMBER SECURITY SYSTEMS REV.00

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

MADE TO PROTECT OUTDOOR DUAL-TECH CURTAIN DETECTORS AGATE / AOCD-250

2 General Application Photoelectric Sensors

Guardall BG-9 BG-9. High Security Seismic Detector

Automatic Self-Adjusting General Purpose Sensor

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

PHOTOELECTRIC DETECTOR

IP65 High Bay Dual Sense Sensor

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Instructions manual. By-alarm. By-alarm Manager software

Description. Optex Incorporated

RILEVATORI DI MOVIMENTO DA INTERNO serie unum

ACTIVE INFRARED PERIMETER DETECTION BEAMS & ENCLOSURES

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible


Dräger REGARD -1 Control System

EXTRA WIDE ANGLE ARRAYS EWA 0.3 GI V1 EWA 0.53 GI V1 EWA 1.35 GI V1 ANIMAL ALLEY ARRAYS AA 0.53 GI V1 AA 0.53 GI M1 AA 0.9 GI M1.

NATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER

IP65 High Bay Dual Sense Sensor

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

HX-80NRAM. High Mount Outdoor Detector

General Purpose Photoelectric Sensor

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

WIRELESS NETWORK USER MANUAL MHz RFT-868-PIR Wireless Passive Infrared Sensor

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

D-Tect 2 GJD300 Quad PIR Movement Detector

Laser Distance Sensor Type M Analog-Output

- Basic information of Laser Scan detector

Open-area Smoke Imaging Detection (OSID)

Transcription:

PARVIS Safe and tranquil thanks to Parvis PARVIS MES 9000S PARVIS DUAL PARVIS WS PARVIS SMA A safety system for outdoors, for civil and industrial environments, nts, that integrates e with the garden lighting system with three different product lines. MES 9000 S The photo-devices with pulse and synchronized infrared beams create an invisible and discreet barrier, because fastened to an aluminum structure placed inside the polycarbonate body with standard diameter for sustenance of the lighting bodies. In fact, thanks to the different types of sealing covers, it is possible to finish off the poles with the various models of lighting bodies available on the market. This and other special characteristics have rendered the product patented ed on a European level.the electronics allow to discriminate at onset the passage of small animals; alternatively, it is possible to command the exclusion of the first two rays at a ce (alarm control unit).the number of double TX and RX beams, their rotation by distan- 180 horizontally and by 20 vertically, placed in a single column, allow to achieve protection, following any type of geometric shape of the site. DUAL Uses the photo-devices and relative electronics of the SANDOR DUAL / QUAD / ESA series with crossed Beams (see characteristics). But lodged in the structure of the PAR- VIS MES. On both lines, the optional feature is available to use the sealing cover with integrated micro-camera, that can be connected to the Video-surveillance eillance system, in addition to the attachment of the lighting bodies. WS The wireless version of the PARVIS line, that can be interfaced with the most common radio alarm transmitters available on the market, thanks to the alarm and ring exits with N.C. contact commanded by bi-stable relays with low absorption. tampe- The autonomy varies based on the number of rays (max. 3 years). 04-05 EUROPEAN PATENT

8 Beam Figure - Simple barrier ADJUSTMENT ANGLE CABLE PASSAGE SECTION 8 Beam Figure - Single barrier HOUSING FOR FASTENING 8 Beam Figure - Crossed barrier HIGH BRIGHTNESS LEDS VISIBLE AT 200m BUZZER PARVIS RP Connection PARVIS DUAL PARVIS DUAL DUAL TRADITIONAL OPTICAL LENS DUAL SMA OPTICAL LENS DUAL IN AND OPTICAL LENS

NEW PARVIS SMA PERFORMANCE Random delay. Parallel and crossed beams. Environmental disqualification from fog with OC signal. AND-OR random or first two beams. Beam 1 or first 2 exclusion. Wire or optical synchronism. Anti-mask with OC signal. Dragging protection. Adjustable crossing time. 4 optical synchronism channels. LED exclusion. NEW SMA RX OPTICAL LENS HEATERS POWER SUPPLY AT 12 OR 24 Vac / Vcc BUTTON ACTIVATED ALIGNMENT NEW SMA TX OPTICAL LENS HEATERS POWER SUPPLY AT 12 OR 24 Vac / Vcc BUTTON ACTIVATED ALIGNMENT POWER SUPPLY 10-30 Vcc HEATERS POWER SUPPLY 10-30 Vac/Vcc TERMINAL BOARD WITH RS485 OUTPUT THE NEW PARVIS SMA The new SMA (single man alignment) technology allows for alignment by a single operator, as the high brightness LEDs and buzzer for each optical lens can reach maximum value without use of additional instrumentation. Alignment is achieved simply via a button located on each optical lens. RS485 output for system centralisation. Ability to operate with optical synchronism.

CHARACTERISTICS TECHNICAL CHARACTERISTICS TECHNICAL PARVIS TECHNICAL CHARACTERISTICS PARVIS MES PARVIS SMA Maximum internal distance of use 400 m Maximum external distance of use 100 m Synchronization Wire Wire or Optical Optical lens with dual beam YES with 35 mm in AND lenses Photo devices Pulsed beams, working wave 950 NM Maximum double beam configuration 4TX + 4RX inside column 4TX + 4RX Beam arrangement Parallel Circuit power supply 13,8 Vcc 10-30 Vcc Circuit absorption From 135 to 150 ma per column, based on the number of beams housed Heater absorption 24 Vac 12-24 Vac-cc Thermostat heater absorption From 30 to 50W per column, based on the number of beams housed Operating temperature from -25 to +65 C Alarm outputs Relay with NC/NO free contacts Tamper protection output Column opening tamper protection Environmental disqualification from fog YES with special OC output (signal attenuation at 90%) Beam anti-masking YES with special OC output RS 485 serial output NO YES for local and remote control on universal resident interface, owner and not, combined with management software Degree of protection IP 54 Pole size Diam. xh 80mm x from 1200 to 4000 mm Different heights available on request PARVIS FUNCTIONAL PERFORMANCE PARVIS MES PARVIS SMA Tracking and alignment system Test point SMA technology via high brightness on each beam LED and Buzzer Optical excursion 180 horizontal and 20 vertical Operating mode settable OR: single beam on board or via remote AND Random (random of two beams) AND 1st and 2nd beam (if there are 4 beams in a column) Dragging protection Settable on the first bottom beam Response time Adjustable 50/500ms Time delay function Random 0 or 2 seconds (can be activated via dip) Beam exclusion mode settable 1st beam at the bottom on board or via remote 1st and 2nd beam at the bottom Temporary total for 1 minute LED activation Can be excluded with dip Optional mounting accessories Housing, plug with microcamera, lighting fixture Accompanying manuals Instructions manual with application example figures Warranty Integral 2 years for manufacturing defects PARVIS MES 9000S is compatible with SANDOR PLUS and MANA IR

CHARACTERISTICS TECHNICAL CHARACTERISTICS TECHNICAL PARVIS TECHNICAL CHARACTERISTICS PARVIS DUAL PARVIS DUAL SMA PARVIS WS Maximum internal distance of use 300 m 400 m 150 m Maximum external distance of use 80 m 100 m 40 m Minimum installation distance between columns TX and RX Column height 1 m 4m Column height 1.5 m 6m Column height 2 m 8m Synchronization Optical lens Optical lens Optical lens Optical lens with dual beam YES with 35mm in AND lenses Photo devices Pulsed beams in working wave 950 NM Maximum double beam 2TX + 2RX 2TX + 2RX or 4TX + 4RX configuration inside column Beam arrangement (4 beams) crossed (2 beams) parallel or Parallel (4 beams) crossed Circuit power supply 13,8 Vcc 10-30 Vcc 3.6V 19Ah batteries included Circuit absorption per column 135mA From 0.5 to 1 microa per column, based on the number of beams Heater power supply 24 Vac 12-24 Vac - cc Not required Thermostat heater absorption 30 W 0 per column Operating temperature from -25 to + 65 C from -25 to + 65 C from -25 to + 65 C Alarm outputs Relay with NC/NO free contacts Low absorption micro relay with NC/NO free contacts Tamper protection output Column opening tamper protection Environmental disqualification from fog NO YES with special OC output Yes but without a special output Beam anti-masking YES with special OC output Degree of protection IP54 Pole size Diam. xh 80mm x from 1200mm to 4000mm PARVIS FUNCTIONAL PERFORMANCE PARVIS DUAL PARVIS DUAL SMA PARVIS WS Tracking and alignment system Test point SMA technology via high Test point on each beam brightness LED and Buzzer on each beam Optical excursion 180 horizontal and 20 vertical Operating mode settable OR: single beam OR: single beam on board or via remote AND two beams AND two beams AND AND 1st and 2nd beam (se in (if there are 4 beams in a column) Response time 250ms fixed Adjustable 50/500ms Time delay function NO Random 0 or 2 seconds (can be activated via dip) LED activation Can be excluded with dip Optional mounting accessories Housing, plug with microcamera, lighting fixture Accompanying manuals Instructions manual with application example figures Warranty Integral 2 years for manufacturing defects