Multi line separator module

Similar documents
Input module, input/output module

Output module (230 V)

Input module, input/output modules

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

FDCL221-M Multi line separator module

Mimic display driver, LED ribbon cable

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FDCL221-Ex Line adapter (Ex)

FDCIO223 (ES 45) Transponder

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

OH720, OP720, HI720, HI722

ASA linear smoke detector

FDOOT221, FDO221, FDT221

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

DM1131 / DM1133 / DM1134 Manual call points

FDOOT241-9, FDOOT241-A, FDO241, FDT241

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDOOT241-A9-Ex Multisensor fire detector

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDCL221 Line separator

FDBZ290 Air sampling smoke detection kit

SWING radio fire detection system

FDBZ290 Air sampling smoke detection kit

FDCW241 Radio gateway Mounting

Fire control panel for modernization

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

Fire control panels FC360

FC722 Fire control panel

Radio fire detection system

FC724 Fire control panel

FC722 Fire control panel

OOH740, OOHC740 Automatic fire detectors

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Fire control panels FC726 FC726-XA

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FC724 Fire control panel

DC1192 Input /Output module

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

DT1101A / DT1102A / DO110xA Automatic fire detectors

OOH740-A9-Ex Multisensor fire detector

DF1101-Ex Infrared flame detector

FC723 Fire control panel

OOH740-A9-Ex Multi-sensor fire detector

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Test units and accessories

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

FC2020 Fire control panel

FDA241, FDA221 Siemens ASD

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Room thermostat with 24-hour time switch and large LCD

Electronic timeswitch

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Test units and accessories

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Frost Protection Thermostat

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FS20 Fire detection system

FDM273 Radio manual call point Mounting

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDL241-9 Linear smoke detector Mounting Commissioning

Call stations and extensions

1592P01. for liquids in piping DN

Sinteso TM product catalog.

FDA241, FDA221 Siemens ASD

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

DF1151-Ex Infrared flame detector

DOW1171 / DCW1151 Radio fire detection system

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

XC10 Extinguishing control panels

Synova TM product catalog.

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDBZ290 Air sampling smoke detection kit Technical Manual

Room Temperature Controllers

Duct Temperature Sensors

Test units and accessories

RVL479. Heating Controller. for use with a partner unit

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Frost Units for air temperature monitoring

Room Temperature Sensors

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Room thermostats with LCD RDD100..

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Flush-mounted room thermostat

Room Temperature Controller

FDS229 Alarm sounder with supplementary optical indication Technical Manual

Use. For 2-pipe fan coils

Fire safety products and accessories siemens.com/cerberus

FDCIO223 Input/output module (transponder)

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Room thermostat with independent DHW control

Room thermostat with Auto Timer, independent DHW

FDCIO223 Input / output module (transponder)

Wall-mounted room thermostat with LCD

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Transcription:

Sinteso Cerberus PRO Multi line separator module FDCL221-M Multi line separator module, addressed (FDnet/C-NET) Automatic module with several separate line separators Formation of stub lines (T-branches) in the FDnet/C-NET Operation of the module in one or two loops Individual addressing of line separators for easy location identification Status indicator (LED) for each line separator Communication via FDnet/C-NET (addressed individually) Easy installation and connection of the stub lines Installation in intermediate distributor or fire control panel 2018-10-04 Control Products and Systems

Properties Features Protected electronics Integrated alarm indicators (LEDs) for signaling the line separation Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated Functions FDCL221-M multi line separator module Nine electronic switches (line separators) Connections for the detector lines (FDnet/C-NET) Connections for the stub lines (T-branches) Jumper for configuring the operation mode 1 loop operation: Nine line separators in one FDnet/C-NET 2-loop operation: Two FDnet/C-NET loops, four line separators in each Disconnects the affected bus area in the event of a short-circuit in the FDnet/C-NET so that the area unaffected by the short-circuit continues to function Yellow LEDs for the status indicator (line separation) Observe national guidelines and regulations. Fields of application: To ensure that several stub lines do not fail in the event of a short-circuit Connection between two stubs on the FDnet/C-NET, if there is no other device between the branches Connection to two separate FDnet/C-NET loops Changing from existing collective systems to the addressed Sinteso and Cerberus PRO fire detection system 2

1 2 3 7 4 6 5 1 Screw terminal for FDnet/C-NET loop 1 5 Jumpers 2 Screw terminal for FDnet/C-NET loop 2 6 FDnet/C-NET loop 2 3 FDnet/C-NET stub lines 7 FDnet/C-NET loop 1 4 Connector (20-pin) for sub-stub lines 3

Type Overview Type Designation Order number Weight [kg] FDCL221-M Multi line separator module S54312-F6-A1 0.126 Accessories for the multi line separator module FDCL221-M Type Designation Order number Weight [kg] TS35 (L = 122 mm) TS35 (L = 288 mm) FDCH221 U-rail TS35/7.5/122 U-rail TS35/7.5/288 Housing with cover, seal, and screws BPZ:5644780001 BPZ:5644230001 0.041 0.098 S54312-F3-A1 0.282 M20 x 1.5 metal cable gland A5Q00004478 0.036 M20 metal counter nut A5Q00004479 0.006 DBZ1190-AB 0.5 2.5 mm 2 (3-pin) connection terminal BPZ:4942340001 0.001 Replacement material for the multi line separator module FDCL221-M Type Designation Order number Weight [kg] FDCM291 Mounting foot A5Q00003855 0.001 Product documentation Document ID Name 008164 Equipment overview Sinteso Detector system FD20 008331 List of compatibility (for 'Sinteso ' product line) A6V10229261 A6V10224006 A6V10224008 List of compatibility (for 'Cerberus PRO' product line) Technical manual Multi line separator module FDCL221-M Installation Multi line separator module FDCL221-M, Housing FDCH221 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download 4

Notes Mounting Mounting options Directly on a flat surface Directly on a U-rail TS35 In housing FDCH221 (accessory) with cover, seal, and screws 1 1 3 1 1 Mounting using mounting feet FDCM291 on U-rail TS35 2 Housing FDCH221 3 Connection terminal DBZ1190-AB 2 Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 5

Technical data Operating voltage Operating current (quiescent) 1-loop operation 2-loop operation FDCL221-M DC 12 33 V 2.25 ma (9x 250 µa) 2x 1 ma (4x 250 µa) Operating temperature -25 +70 C Storage temperature -30 +75 C Air humidity (non-condensing) Communication protocol Colors: Module carrier Housing FDCH221 Housing cover Protection category (IEC 60529) Without housing With housing FDCH221, screwed 95 % rel. FDnet/C-NET ~RAL 9010, pure white ~RAL 9010, pure white Transparent matt IP30 IP65 Standards EN 54-17 Approvals VdS LPCB System compatibility FDnet C-NET G209162 531n/02 FS20 FS720 6

Dimensional drawings Multi line separator module FDCL221-M 43.5 46.5 8.2 24 A 118 132 102 36 A A = 4.5 5.8 09 0786 FDCL221-M FDCL221-M - Short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. A6V10224006 305/2011/EU (CPR): EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20847; DoC No.: CED-FDCL221-M 7

Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2008 Technical specifications and availability subject to change without notice. 8 Document ID Manual FD20/FD720 Edition 2018-10-04 Register 5