POWDER APPLICATOR. Perma Press

Similar documents
Operating Instructions and Spare Parts List. ZR Monocyclone. Issued 09/01. ZR Monocyclone 9

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

VULKAN. Stationary Powder-Filling Machines

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

KEE & SEE URAS VIBRATORS

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Flow-Rite Original Ink Dispensing Cartridge

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

LDDC Series Double-Deck Drum Pre-cleaner. Instruction Manual LAMBTON MACHINERY(ZHENGZHOU)CO. LTD

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Product instruction manual Easymount Wide Format Laminators

Practic - HLE. Piston Compressors 2 TO 10 HP 6 TO 500 LITRES

GRIND PRO DUAL OR DISC SANDER. Operator Manual

FD Heavy Duty Feeder for FD 280 Tabbing System

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HEATING AND VENTILATION

Product instruction manual Easymount Wide Format Laminators

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INSTALLATION AND MAINTENANCE OF THE "THOMPSON-BRITISH" AUTOMATIC PLATEN

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Read this entire manual before operation begins.

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

INSTALLATION INSTRUCTIONS

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

Manual of Versatility Heat Press Machine. Operation warning

hp Dust Collector With Vacuum Attachment

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

BASIL 6700 TUNNEL CAGE WASHER

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

3 in 1 Garden Vacuum 9255 Instructions for Use

INSTRUCTION MANUAL Model: SU3022

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Model Letter Opener Revision 3 - Brush Transport

XPS-ProDry User s Guide Dryer Base

FD 430 Envelope Sealer

Creasing and Folding

CG60/ 70/ 80/ 90/ 100 SS/BK

7. Industrial Cylinder Heated Drying Ironers FCU 1664/320, FCU 2080/320. Features and Benefits. Options. preferred by on-premises laundries worldwide

PART II. THE PRECLEANING OF PADDY

Operating Instructions

Tempest /PowderPro. Installation Instructions. Heidelberg QM46DI X /98

BASIL 6000 TUNNEL CAGE WASHER

OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER

ART cm Island Curved Glass

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Metos HOT-FILL and SOUS-VIDE pumps and basins

LTP50 TABLET PRESS USER MANUAL

For contact or information about your nearest sales office please visit:

SECAP Conveyor TC72 / Dryer TD72

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

TSS 15/55 Hi-Lift Vacuum

INTERNATIONAL MACHIINE CONCEPTS. Operating Manual. Tablet Counting and Filling Machine. Model IMC

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

The Original & Patented Self-Cleaning Vacuum Product Catalog Ridgeview Tulsa,OK

BWS 1000 OPERATION AND MAINTENANCE MANUAL

Part No KEMPER Filter-Master XL

200Kg/h Frozen Potato Fries Process Machine List

Joto Mister T1 Pretreat Machine Model No.: E-PT-MT1

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Cooling Unit for Producing Chilled Water. Envicooler. Operation and Maintenance Instructions. Air handling with the focus on LCC

Installation Guide. P1500W Series Air Dryer

Simply Plug and Convey

SOLUTIONS TO STATIC PROBLEMS

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

Recycling Equipment for Processing recycled Refrigerators

OWNER S MANUAL. Model No. B-16 STAND PET DRYER

OWNER S MANUAL #DC2000B #DC2000BCF

INK CURING TIPS TIPS & TECHNIQUES

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Powered by the Dyson digital motor V4

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Installation manual. Tumble dryers T4130. Compass Control

Tempest Hot Air Drying System. Installation Instructions. Ryobi X /98 Rev-C

Solid biofuel solutions

DEUTSCH Bio-Master Bio-Max

100cm Chimney Hood GB IE

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

Operation Manual for the ProVetro Profi-Beveler Ø 60 cm

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

INSTRUCTION MANUAL. 05/13/03 Part # TITAN Rollbag TM MODEL 1055

AIRSPEED TECHNOLOGY High velocity airflow Powerful cleaning performance ZAS1000A

Static Control in the Plastic Bottling Industry

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Tempest TP420/180 Electric Pressure Washer

Installation and Servicing Instructions. Alpha GasSaver GS-2

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64

LITTLE BLASTER LARRY HESS AND ASSOCIATES, INC. BLAST-IT-ALL P.O. BOX 1615 SALISBURY, NC WITH DUST COLLECTOR

Portable Air Conditioner USER MANUAL

INSTALLATION INSTRUCTIONS

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM

Mopit 4 Operator s / Service Manual

General Characteristics.3. S.M.A.R.T System Set-up...5. Start-up Procedures.6. Shut-down Procedures 8. General Maintenance..8

List of tables. User manual MONIKA 2, ROTA

Transcription:

APPLICATOR Perma Press

Perma Powder Applicator This fully automated machine applies powders to the printed area and also collects the excess powder all in one operation. Characteristics Adds adhesive powder automatically, removes all excess grains automatically, recycles excess powder automatically.many producers of screen transfers are spending hours on applying adhesive powder manually. Many have problems with static electricity or difficulties getting rid of excess powder outside the printed area. With the Perma Powder Applicator you can avoid all these problems. The Perma Powder Applicator was developed by a screen printer for screen printers. It is constructed and manufactured in Sweden and our aim has been to produce a high quality machine, with excellent durability and performance.

Advantages of the Perma Powder Applicator Runs sheets up to a width of 100 cm, continuously and fast. Any excess powder is recycled automatically. Improved working environment due to a unique construction that filters the circulating air. Less problems with static electricity. Special discharging of static electricity makes your work run smoothly and without interference. New, innovative suction and air knife system makes sure that any excess powder is removed outside the printed areas. Description of Function Application of Adhesive Powder on Transfers (or any other kind of powder) The body of the machine is made of steel, welded sheet steel with red painted finish, and a net shaped belt conveyor is to be found on it. Above the belt conveyor and perpendicular to the direction of the movement of the belt conveyor, there is on one end a powder scatterer, and on the other end an air knife. When the belt conveyor is rolling and a print sheet is laid flat on it in the beginning of the line direction, the print sheet will first pass under the powder scatterer. The powder scatterer is vibrating and adhesive powder will fall from the scatterer down onto the passing print sheet, creating a thin and even layer of powder on it. The moist ink of the newly printed transfers will fix the powder where it is wanted (on the transfers), and not on the naked parts of the print sheet. This fixation is used when the print sheet then passes under the air knife, where the excess powder on the print sheet alongside of the transfers will be blown off, while the fixed powder on the transfers will remain. Hence the powder will only lie on the transfers. The belt conveyor is vibrating in order to bounce up the loose powder, making the blow off process more efficient. Consequently, when the print sheet with the transfers has passed the air-knife, there will be adhesive powder only on the transfers and no undesired adhesive powder alongside. Circulation of Powder The adhesive powder, which doesn t stick to the transfers due to the fact that it falls alongside the print sheet, or is not fixed on the transfers and therefore blown off the print sheet, will be sucked down by the suction fan through the net shaped belt conveyor into the underlying collecting vessel. The powder, which is collected in the collecting vessel, will be pumped up to the powder scatterer by two suction pumps, and the circulation is thereby completed. There is a filter in the shape of a cylinder, which is cleaning the sucked down air from the adhesive powder. Some of the air, which is sucked down and cleaned by the filter, will be used for the air-knife, while the rest will be let out into the air in the room. Please note that this filtered air is cleaner than normal indoor air. The filter is cleaned with a heavy blow of air.

MAIN SWICH SUM BELT 5 6 5 6 7 4 7 4 8 3 8 3 9 2 9 2 10 10 1 1 BELT FAN Installing the PERMA Powder Applicator 1. The machine (which is mounted on wheels) is delivered in running order, fully prepared for installation between the printing machine and dryer. A professional should carry out installation. 2. The unit is designed for connection to a 400 V/16 A**, three-phase electric power supply. 3. The unit is also connected to a 6 bar compressed air supply. (Compressor is not included.) 4. No external air ducts are required. The filtered air is purer than normal indoor air. Technical Description of the Perma Powder Applicator 1. Drop down inlet 2. Conveyor belt 3. Powder scatter 4. Double airknife 5. Conveyor vibrator 6. Emergency stop 7. Electrical control cubicle 8. Operation panel 9. Main switch 10. Filter regulator 11. Excess air 2170 mm CLEAR SPEED OF SPEED OF FILTER CONVEYOR ALARM VIBRATOR 800-8700 mm PRESSURE OF FLUIDIZATION FILTER CLEARING TRANSPORTATION OF 1950 mm SUCTION CONVEYOR CONVEYOR VIBRATOR VIBRATOR 1380 mm FEEDER 1380 mm 900 mm Perma Powder Applicator from frontside Perma Powder Applicator from above

Powders: Most kinds of powders can be used and easily exchanged if the process requires a different kind of powder. The powder is exchanged in the following way; The suction pump is switched off, while the vibrator of the powder scatterer is kept running. The aperture of the powder scatterer is opened to the maximum and all the remaining powder in it is emptied out. As all of the powder has been collected in the vessel, the suction fan is turned off. Empty the collecting vessel and then add the new powder into it. Switch the suction fan and the suction pump on. The machine is now ready to operate again. Maintenance of the Perma Powder Applicator Conveyor belt, air tubes and hoses should be inspected daily. Adjustments of conveyor belt (by tightening or loosening the nut on one of the pulley axles) may be necessary every once in a while. Filter should be inspected occasionally, and may need to be cleaned / replaced after some years. Perma Powder Applicator Standard Equipment 1 Perma Powder Applicator 1 manual (in English) Filter box (patent pending) Easy change of filter, open the door and replace in seconds Working Space: Depth: Width : Height: 140 cm (55 in) 217 cm (85 in) 155 cm (61 in) Powders: Most kinds of powders can be used Airknife Double, adjustable airknife for secure removal of excess powder.

Accessories: These parts are not included as standard and have to be bought separately. Air compressor Technical Specifications Model for sheet size 70x50cm (19 x25 )* * Unit of measurement stated in foot and inches, and unit of weight stated in pounds. ** American model adjusted to US standards regarding voltage, amperage etc. is available. Size and Weight Total height: 140 cm (4 7 )* Conveyor height: 80-85 cm (2 8-2 9 )* Length: 140 cm (4 7 )* Width: 208 cm (6 10 )* Conveyor width: 90 cm (36 )* Weight: 250 kg (550 lbs.)* Electrical Specifications Electric Voltage: 400V** through three-phase electric power supply, with no use of neutral. Amperage: 16A** / 6,3** in normal use Cycle per Second: 50-60 Hz Fuse: 16A** Compressed Air: 6-bar pressure from compressor Perma Press AB Faktorvägen 5, Box 10 274, SE- 434 23 Kungsbacka, Sweden. www.permapress.se Phone: +46 300-56 80 50 Fax: +46 300-188 12 E-mail: sales@permapress.se