Swimming Pool Heat Pump

Similar documents
Swimming Pool Heat Pump

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL

ULTRATEMP TM HX HIGH PERFORMANCE HEAT PUMP

INSTALLATION AND USER MANUAL

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

INSTALLATION AND USER MANUAL

Dehumidifier User Manual. (For the series of DP40~DP70)

General safety precautions English

General safety precautions English

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

PC20-AMFII / PC40-AMF USER MANUAL

SWIMMING POOL HEAT PUMP

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

Inverter Swimming Pool Heat Pump

INSTALLATION AND USER MANUAL for your heat pump

Owner s Manual Super-Slim Four-Way Cassette

USER MANUAL TPS-M5/M55/M555

Inverter Air Source Heat Pump Monobloc system

Instructions for installation

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Owner s Manual for Swimming Pool Heat Pump

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Swedish design and manufacture since 1967

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Portable Air Conditioner. Instruction Manual

SWIMMING POOL HEAT PUMP Owners Manual

Hydro-S Heat pump 230V black type 12horizontal. Swimming Pool HeatPump UserandServicemanual

Tankless Water Heater

OPERATING INSTRUCTIONS

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

Harmo Powerpack Horizontal Units Installation & instruction manual

Reverse Cycle Split System Air Conditioner

Inverter Split-type Room Air Conditioner

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Operating Instructions Air Conditioner

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

OWNER S MANUAL VMH 09/12/18/24

KSD-35 DR11 KUE-35 DVN11

Residential Gas Hybrid Water Heater

General safety precautions English

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

OPERATION MANUAL. Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A

WARNING/SAFETY PRECAUTIONS

FR120RC/FR120RM FR120RR/FR120RB FN-153/FN-153C

Cabinet Refrigerators/Freezers Instruction manual

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Bar Fridge USER MANUAL MB46W

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

DD12E DEHUMIDIFIER USER'S MANUAL CONTENTS. VOLTAGE: V~50Hz

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

ULTRA LOW TEMPERATURE FREEZER. User Manual

OPERATION MANUAL. Packaged air-cooled water chillers and packaged reversible air to water heatpumps EWAQ009ACV3 EWAQ010ACV3 EWAQ011ACV3

User s Information Manual

Split Portable Air Conditioner

PORTABLE AIR CONDITIONER (LOCAL)

Owner's Manual TABLE OF CONTENTS

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

Instructions for installation and use English. More documents on: H B /09

Progress plus Instruction manual

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Reverse Cycle Portable Air Conditioner with Dehumidifier

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Swimming Pool Heat Pump

General safety precautions English

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Model Modèle Modell Modello Modelo Malli:

CONTENTS. 1.1 General terms of delivery Voltage Water treatment... 2

General safety precautions English

Universal Fire Tube Boiler Wall Mount Models

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

DAIKIN ROOM AIR CONDITIONER. Operation Manual

HT V2 HT Split

Air source heat pump. (water heating module-18kw)

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

Convection Panel Heater

Installation Manual Compac 6/8

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Local Air Conditioner

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

PORTABLE AIR CONDITIONER (LOCAL)

Dehumidifier User Manual

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

Operation and Installation Manual

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

Transcription:

Swimming Pool Heat Pump - Operation and Installation Manual - Model:LCSPI-95BP,LCSPI-135BP,LCSPI-180BP, LCSPI-220BP, LCSPI-280BP

TABLE OF CONTENT INTRODUCTION...... 2 This manual... 2 The Heat Pump... 2 SAFETY INSTRUCTIONS. 3 Warning.. 3 Caution. 4 CONTENTS..... 4 OVERVIEW OF THE UNIT.. 5 EXPLODED VIEW. 6 INSTALLATION....... 7 Installation guidelines.... 7 Locating your Unit..... 7 Water connection..... 7 Electrical connection.... 8 Trial running..... 8 OPERATING THE UNIT.. 9 Features and functions. 9 User interface... 9 Buttons... 10 PARAMETER CHECKING AND ADJUSTMENT... 11 Parameter query table. 11 Parameter settings. 11 SYSTEM PROTECTIONS/ERROR CODES. 12 MAINTENANCE.. 13 TROUBLESHOOTING... 14 ENVIRONMENTAL INFORMATION... 14 DISPOSAL REQUIREMENTS. 15 WIRING DIAGRAM.... 16 INVERTER SWIMMING POOL HEAT PUMP TECHNICAL SPECIFICATION 17 READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT. DO NOT THROW IT AWAY. RETAIN FOR FUTURE REFERENCE. BEFORE OPERATING THE UNIT, ENSURE THE INSTALLATION HAS BEEN CARRIED OUT IN ACCORDANCE WITH THESE INSTRUCTIONS. IF IN DOUBT CONSULT YOUR LOCAL DEALER. 1

INTRODUCTION This manual This manual includes the necessary information to safely install and maintain your Heat Pump. Please read this manual carefully before you operate the unit. The Heat Pump The swimming pool heat pump is one of the most economical ways of heating your swimming pool efficiently. Using the free renewable energy from the air,it is over 4/5 time more efficient than traditional heating.the swimming pool heat pump extends your swimming season and gives you comfort at high level.you could enjoy swimming not only in summer,but also in spring,autumn and even winter time. ECO Friendly The Heat Pump uses R410A Refrigerant which is ozone friendly dramatically reducing Carbon Emissions. Titanium heat exchanger The advanced titanium heat exchanger guarantees a longer life span, free of corrosion. It can be used with all types of water treatment including chlorine, iodine, bromine and salt water. Multiple functions - Cooling and heating functions available - Auto operation, Auto-restart, Auto defrost - Auto timer on/off:no human attendance is required - Wide ambient working range: -10 C to 43 C Reliable operation The Heat Pump has several built in safety features, which include insufficient water flow protection, high/low pressure protection, overload protection, compressor protection. Self-diagnosis When there is malfunction,the swimming pool heat pump will make self-diagnosis by displaying error code on the control panel.to identify the problem,please refer to ERROR CODES pages in this manual. 2

SAFETY INSTRUCTIONS To prevent injury to the user, other people or damage to property, the following instructions must be followed. Install the unit only when it complies with local regulations, by-laws and standards. Check the main voltage and frequency. This unit must be earthed and have a supply voltage of 220 240 V ~ / 50Hz. The following safety precautions should always be taken into account: - Be sure to read the following WARNING before installing the unit. - After reading these instructions retain for future reference. Installing the Unit. Incorrect installation could cause injury due to fire, electric shock or water damage. If in doubt consult your local dealer or a qualified installer. Securing the Unit. The unit should be located on a solid, level, horizontal surface and securely fixed. Ensure free air-flow to all sides of the unit. Electrical Connections. Ensure the correct sized Circuit Breakers, isolators and cables are used.all terminals should be tightly secured and not prone to stress. This unit must be earthed. Materials. To prevent fire, electric shock and other hazards all materials should be suitable for the specific use of this unit. Never use an extension cable to connect the unit to the electric power supply. If there is no suitable earthed supply available, have one installed by a qualified electrician. Do not move/repair the unit yourself. Before carrying out any maintenance, service or repair work, the product must be isolated from the mains electrical supply. To prevent possible injury, only qualified engineers should carry out these works. Do not install the unit in a place where there is a chance of flammable gas leaks. If there is a gas leak and gas accumulates in the area surrounding the unit, it could cause an explosion. 3

Water Connections. All plumbing connections should be carried out as per the instructions in this manual. Failure to do so could result in water damage to property. Cleaning the Unit. To prevent injury always shut the power OFF when cleaning or servicing the unit. Error Codes. If an error code occurs or you can smell burning, isolate the unit immediately and call your local installer. Avoid contact with the fan when running as this will cause serious injury. CONTENTS Before starting the installation, please make sure that all items are found inside the box. The Unit Box Item Image QTY Item Image QTY Swimming pool heat pump 1 Accessories 1(Set) Operation and Installation Manual 1 4

OVERVIEW OF THE UNIT 5

EXPLODED VIEW 6

INSTALLATION Installation guidelines The following information is for guidance only. Locating the Unit The unit should be located on a solid, flat, horizontal surface. Ensure 3 metres of free air flow to the discharge panel and 1 metre to the inlet panel. Ensure adequate access to the controller and for maintenance purposes. Precautions --Avoid locating the unit close to bedrooms or other noise sensitive areas. --Avoid a location which could create vibration i.e. secured to a solid wall. --Try to avoid placing the unit under a tree or exposed to extreme conditions. Water connection The heat pump is connected to a filtration circuit with a by-pass. It is imperative that the by-pass is placed after the pump and the filter. The by-pass generally consists of 3 valves. This makes it possible to regulate the water flow which passes through the heat pump and to isolate the heat pump completely for any maintenance work, without cutting the flow of filtered water. If your installation is equipped with a water treatment system (chlorine, bromine, saltetc) the by-pass must be installed before the water treatment, with a non-return valve between the by-pass and water treatment system. 7

Electrical connection The Electrical supply must correspond to that indicated on the appliance. All supply cables have to be sized according to the appliance power and installation requirements. Please refer to below table: The above are an indication only.please refer to a qualified Electrician if in doubt. Use the cable glands and grommets provided inside the heat pump to secure and route the supply cables. Trial Running After connecting the unit to the pool system, ensure your installation is complete, with a suitable by-pass and electrical connections by a qualified engineer. Be sure that: 1) Appliance is horizontal and on a firm base. 2) Water system has no leaks. 3) Electrical Installation is compliant with all local regulations and standards. 4) The installation requirements described previously have been strictly adhered to. ATTENTION: THE HEAT PUMP ONLY OPERATES WHEN WATER FLOW IS PRESENT. You can start up the heat pump following the procedure below: - Open by-pass valves - Start pool system pump - Turn on pool heat pump - Set controller 8

Features and functions Basic controller functions The basic controller functions are: Turning the heat pump ON / OFF. 24 hour time clock. Timer ON and timer OFF. Parameter adjustment User interface NEVER LET THE DIGITAL CONTROLLER GET WET. THIS MAY CAUSE AN ELECTRIC SHOCK OR FIRE. NEVER PRESS THE BUTTONS OF THE DIGITAL CONTROLLER WITH A HARD, POINTED OBJECT. THIS MAY DAMAGE THE DIGITAL CONTROLLER. NEVER INSPECT OR SERVICE THE DIGITAL CONTROLLER YOURSELF. REFER TO A QUALIFIED SERVICE ENGINEER. 9

Buttons Unit ON/OFF button Press this button for 3 second to switch unit ON/OFF. Mode button Under main operation interface when unit ON,press this button for 3 seconds to switch heating or cooling modes. and adjustment buttons On main operation interface under heating mode,press and buttons to set target outlet hot water temperature. On main operation interface under cooling mode,press and buttons to set target outlet cooling water temperature. Clock/Timer button Clock settings:press for 3 seconds entering into clock flashing status,then press entering into Clock Setting status:firstly Hour-digit flashes,press and to adjust number,press or each time will make number up or down by one time,if press or for long time,hour-digit will automatically up or down.after finishing setting Hour-digit,press entering into Minute-digit settings,which is same as Hour-digit settings.after Minute-digit settings finished,press to exit. Timer settings:press entering into Timer selection, Timer 1 will firstly display,press or to choose different Timers.Then press again to enter into Timer1 settings,press or to adjust target time,other Timers settings are in same way. Mandatory defrost 10

Press and for 3 seconds entering into mandatory defrost mode. Factory reset Press + + + for 3 seconds entering into factory reset. PARAMETER CHECKING AND ADJUSTMENT Unit running status query On main operation interface,press following table: for 3 seconds to check temperatures,see the Code Temperature Name Display Range 01 Inlet water temp -20~99 02 Outlet water temp -20~99 03 Ambient temp -20~99 04 Exhaust gas temp 0~125 05 Return gas temp -20~99 06 Coil temp -20~99 System parameter query and settings Press for 3 seconds entering into parameter query status,press or to check parameters,then press to modify parameters by using with or, after modifications completed,press to confirm and exit. SYSTEM PARAMETER TABLE Code Parameter Name Adjustment Range Default P01 Target/inlet water temp difference 2 ~18 2 to start compressor P04 Target cooling water temp 7 ~30 12 P05 Target hot water temp 15 ~50 35 P06 Exhaust gas overheat protection gas temp 80 ~125 120 P07 Exhaust gas overheat protection exit gas temp 50 ~100 95 P08 Compressor current protection 2A~50A 20A P09 Inlet water temp compensation -5 ~15 0 11

P11 Defrost cycle 20MIN~90MIN 45MIN P12 Defrost entry coil temp -15 ~-1-3 P13 Defrost duration time 5MIN~20MIN 10MIN P14 Defrost exit coil temp 1 ~40 20 P15 Ambient/coil temp difference for defrost entry 0 ~15 5 P16 Ambient temp for defrost entry 0 ~20 17 P17 EEV action cycle 20S~90S 30S P18 Heating EEV action factor -5 ~10 3 P19 Exhaust gas temp to trigger EEV adjustment 70 ~125 95 P20 Defrost EEV open angle 20~450 400 P21 EEV min. open angle 50~150 80 P22 EEV mode option 0:manual/1:auto 1 P23 EEV manual step 20~450 350 P24 Cooling EEV action factor -5 ~10 3 P27 Cooling EEV working mode 0=Ambient temp; 1=Cooling EEV 0=Ambient temp action factor P28 Water pump working option 0=Stop when target water temp reached /1=NOT stop when target water temp reached 0=Stop when target wate temp reached SYSTEM PROTECTIONS/ERROR CODES When an error occurs or the protection mode is set automatically,the wired controller will display an error code as below. Error code Error Name Remark Er 03 Water flow failure Er 04 Winter anti-freeze protection Er 05 High pressure failure Er 06 Low pressure failure Er 09 Communication failure Er 10 Inverter module communication failure(communication failure btw. PCB and inverter module) Er 12 Exhaust gas over-heat protection Er 15 Inlet water temp sensor failure Er 16 Coil temp sensor failure Er 18 Exhaust gas temp sensor failure Er 20 Inverter module abnormal run protection 12

Er 21 Er 23 Er 27 Er 29 Er 32 Er 35 Ambient temp sensor failure Outlet cooling water over-cold protection Outlet water temp sensor failure Return gas temp sensor failure Outlet hot water over-heat protection Compressor current protection MAINTENANCE To protect the paintwork, avoid leaning or putting objects on the shell. External Heat Pump parts can be wiped with a damp cloth and domestic cleaner. (Warning: Never use cleaning agents containing sand, soda, acid or chloride as these can damage the surfaces.) To prevent blockages in the titanium heat exchanger, ensure that the system incorporates a water and filter treatment facility. In the event of a problem occurring due to contamination, the system should be cleaned as described below. (Warning: the fins on the finned tube heat exchanger are sharp!). Cleaning the Heat Exchanger and Pipework Contamination in the pipes and heat exchanger can reduce the performance of the heat pumps titanium heat exchanger. If this is the case, the pipe system and heat exchanger must be cleaned by a technician. Use only pressurized drinking water for cleaning. Cleaning the air system The finned heat exchanger, fan and condensate outflow should be clear of all obstructions (leaves, twigs, etc.) before each new heating season. These can be manually removed using compressed air or by flushing with clean water. It may be necessary to remove the unit cover and air inlet grid first. Attention: Before opening the unit, ensure that all electrical supplies are isolated. To prevent the evaporator and the condensate tray from being damaged, do not use hard or sharp objects for cleaning. Under extreme weather conditions (e.g. snow drifts), ice may form on the air intake and exhaust air outlet grids. If this happens, the ice must be removed in the vicinity of the air intake and exhaust air outlet grids to ensure that the minimum air flow rate is maintained. Winter Shutdown. To prevent frost damage to the unit when not in use the Heat Pump should be drained of all water. Failing this another form of frost protection should be considered and actioned. Attention: The warranty does not cover damage caused by inadequate frost protection measures during the winter. 13

TROUBLESHOOTING This section provides useful information for diagnosing and correcting certain prolems which may occur. Before starting the troubleshooting procedure, carry out a thorough visual inspection of the unit and look for obvious defects such as loose connections or defective wiring. Before contacting your local dealer, read this chapter carefully.it could save you time and money. WHEN CARRYING OUT ANY MAINTENANCE ENSURE ADEQUATE PRECAUTIONS ARE TAKEN TO PREVENT AN ELECTRIC SHOCK. The hints below are for guidance only. If you cannot solve the problem, consult your installer/local dealer. The Heat pump will not run. Please check: There is a supply voltage (tripped fuse, power failure). The switch on the wired controller is switched on, and whether the correct set point temperature has been set. The set temperature level cannot be reached. Please check whether: The permissible operating conditions for the heat pump have been adhered to (air temperatures too high or too low). The air inlet or outlet area is blocked, restricted or very dirty. There are closed valves or stop-cocks in the water pipes. The timer works but the programmed actions are executed at the wrong time (e.g. 1 hour too late or too early). Please check whether: The clock and the day of the week are set correctly, adjust if necessary. If you cannot correct the fault yourself, please contact your after-sales service technician. Work on the heat pump may only be carried out by authorized and qualified after-sales service technicians. ENVIRONMENTAL INFORMATION This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol. It should only be serviced or dismantled by professional trained engineers. This equipment contains R410A refrigerant in the amount as stated in the specification. Do not vent R410A into the atmosphere: R410A, is a fluorinated greenhouse gas with a Global Warming Potential (GWP) = 1975. 14

DISPOSAL REQUIREMENTS Dismantling of the unit, treatment of the refrigerant, of oil and of other parts must be carried out in accordance with relevant local and national legislation. Your product is marked with this symbol. This means that electrical and electronic products should not be mixed with unsorted household waste. Do not try to dismantle the system yourself: the dismantling of the system, treatment of the refrigerant, of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation. Units must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring that this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information. 15

WIRING DIAGRAM Please refer to the wiring diagram on the electric box. LCSPI- BP 16

Inverter Swimming Pool Heat Pump Technical Specification Model LCSPI-95BP LCSPI-135BP LCSPI-180BP LCSPI-220BP LCSPI-280BP Air 27,Water inlet/outlet:26 /28, Humidity 80% Air 15,Water inlet/outlet:26 /28, Humidity 70% Power supply Capacity(kW) 10.23~2.55 14.11~3.52 19.12~4.78 22.79~5.69 28.68~7.16 COP 16.11~6.14 16.23~6.19 16.18~6.15 16.09~6.12 16.07~6.11 Capacity(kW) 8.06~2.01 11.02~2.75 14.11~3.52 17.18~4.29 21.53~5.38 COP 8.16~4.72 8.22~4.75 8.19~4.73 8.11~4.63 8.05~4.61 230V/1Ph/50Hz Rated power input kw 1.71~0.16 2.32~0.21 3.12~0.29 3.72~0.35 4.71~0.45 Evaporator Heat exchanger Hydrophilic fin and copper tube Titanium in PVC shell Water flow volume m³/h 3.5 4.8 5.9 7.5 9.6 Package dimensions mm( L*W*H) 662*724*950 662*724*950 757*826*1080 757*826*1080 757*826*1080 Unit net dimensions mm( L*W*H) 650*688*823 650*688*823 745*792*954 745*792*954 745*792*954 Sound pressure at 1m Sound pressure at 10m Water proof level db(a) 39~48 40~49 43-52 45~54 45~55 db(a) 19~28 20~28 23~32 24~34 25~36 IPX4 17