(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24

Similar documents
Control and extinguishing by water mist

What is conventional fire detection?

Installation & User Manual DURAUTO. Domestic Gas Detector

TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

GL-CO-RFG Channel Gas Leak Alarm System

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

NG-9B NATURAL GAS ALARM

KAE Gas Alarm Operation Manual

Gas Leak Detection Alarm

KAB Gas Alarm Operation Manual

Gas leak detection + trapped person alarm

OPERATING INSTRUCTIONS

169MHz Telecare Devices Gas & Carbon Monoxide Detector

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

Installation, Operating and Maintenance Manual

169MHz Telecare Devices. Gas Detector

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

PROGRAMMING MANUAL. CM (Micro v. 1.0)

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Electronic control unit for gas leak detection with 4 detection zones

_VF3640-STAND-FAN_ /01 24/02/14 09:33 Page1. Harmony VF /01

FEC400 Series. Installation Manual

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Operation & Maintenance Manual

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB750. Issue 01

M15051) INSTRUCTION MANUAL

WARNING FIRE DOOR CLOSING

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

PORTABLE AIR CONDITIONER

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

De Longhi Appliances via Seitz, Treviso Italia /11.13

FR EN NL DE ES PT IT TR RU UK

EXTINGUISHING CONTROL PANEL PX2 SERIES

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Pioneer-R16 Gas Monitor Operator s Manual

Instructions Manual SHC520X - SHC700X

PORTABLE AIR CONDITIONER

GLD-30 Gas Leak Detector

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

TCM-2 Thyristor Control Module DATA SHEET

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Smoke Alarm User s Manual

10yr O2NE & Safe-Ox. User Manual

ADOS Biogas 905. Multi-channel Gas Analyser. A D O S GmbH Instrumentation and Control Trierer Str FRG

IRceL CH4 Methane (CH 4

Two-Channel Gas Controller

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

Dual Alarm Clock Radio

O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec.

Operating instructions Page 12

CO 2 Fire Extinguishing Systems

7 Fin Oil Filled Radiator

OPERATING INSTRUCTIONS

testo 316-EX gas leak detector Instruction manual

Commercial and Light Industrial Fire Alarm Control Panel

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

User and Installation manual

Fire Alarm Advanced Application AEL-AD3A

LF-4000 Series Conventional Fire Alarm Control Unit

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use

CARBON INFRARED HEATER CH2500 TW

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

PolyGard 2-channel Gas Controller MGC-03

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

GS100M Gas Detector. Technical Specification

DS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Alarm Panel Operating Instructions

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

2 Front Back ᄠ ౪ᄠ ᑵෂ ۳ෂ

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

General Care and Safety Guide

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

Register your new Bosch now:

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

INSTRUCTION MANUAL FOR USE AND MAINTENANCE

Transcription:

(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24 Microprocessed gas detector, designed according to Regulation UNE-EN 50194, allows for METHANE gas detection (natural or town gas). The detector is gauged in order to inform about a danger when gas concentration over 10% of the Explosive Lower Limit (L.I.E.) 1 is reached. When the concentration level is lower than 10% L.I.E. again, within a particular time, the detector will be reset automatically. The detector is catalogued as Type-A device, as a visual and sound alarm is produced and an outlet which can act directly or indirectly on a cutting device and/or other auxiliary devices. It is provided with: Green light indicator for feeding and operation detector. Alarm red light indicator. Failure orange light indicator. Acoustic indicator for prealarm and alarm through piezoelectric buzzer. Relay output through tension-free NA, C and NC contacts. Internal push-button for operation test cycle. The detector feeding tension may vary according to the selected model. AE09/GM 230V AC AE09/GM-12 12V DC AE09/GM-24 24V DC The detector needs to be fed for proper performance. When the detector is fed, 120 seconds are needed for warming and stabilization, during such time, the detector is not able to detect the presence of METHANE gas. 1 L.I.E. Volumetric concentration of gas or flammable vapour in the air under which a gas explosive atmosphere can not be formed..

INSTALLATION. WARNINGS. Installation and dismantling of these devices is to be made by authorized personnel. Do not manipulate or open the units as it may result in electrocution and wrong operation. Such devices are not to be used by persons (adults or children) with reduced physical, mental or sensorial capacity or by people who do not have the needed knowledge or experience unless they are supervised or trained on the use of the apparatus by a person responsible for their safety. Children must not play with the units. At the power supply connection to the fixed installation, a full disconnection system is to be incorporated in accordance with the regulations on installation currently in force. The detector will be installed over the level of a possible gas exhaust, and near the ceiling, 30 cm. maximum, and in a place where air can flow without being stopped by the furniture. The detector will be installed vertically, allowing for the air circulation through the air vents in the detector casing. 30 cm More than 30 cm CORRECT POSITION INCORRECT POSITION The detector should not be installed: In a closed space (for example in a cabinet or behind the curtains); directly over a sink; near a door or window; near an extractor fan; in an area where temperature may decrease below -10 C or over +40 C. In places where dust and dirt may block the sensor; In a wet or humid place.

WIRING For the detector wiring, it is necessary to open the detector by pushing on the side parts of the cover in order to to access the connection terminals. SUPPLY VOLTAGE AE09/GM Model AE09/GM needs to be feed at 230V AC for proper performance. The detector is provided together with a 1.8 m cable ready to be connected to a socket. Direct connection to CL1 terminal without using the cable is also possible. AE09/GM-12 AE09/GM-24 Model AE09/GM-12 needs to be feed at 12V DC for proper performance. Such tension, from a power supply, is to be directly connected to CL2 terminal. Model AE09/GM-24 needs to be feed at 24V DC for proper performance. Such tension, from a power supply, is to be directly connected to CL2 terminal. OPERATION RELAY. All models of detectors are provided with a relay outlet through tension-free contacts, that tilts 10 seconds after the detector goes to alarm state. This outlet may be used to connect an electrovalve for the gas supply cut-off or to repeat the detector state in a centralized alarm system. Terminal assignment is as follows: C NC NA Common contact Closed contact, in standby Open contact, in standby

Feeding examples for normally fed electrovalves. Electrovalves are usually open when being fed. When cutting-off the power supply blocks the gas flow and manual reset is required.

OPERATION HEATING PERIOD When the detector is fed, a heating period for the sensor starts, necessary for it to stabilize and carry out the correct measure of the METHANE level in the environment. This cycle takes 120 seconds and it is shown through the flashing and alternate activation of red light indicators for ALARM and orange indicators for FAILURE. When this cycle is finished, for correct operation of the detector, only the red indicator for FEEDING should be lit continuously. STANDBY STATE. This state is shown through fixed lighting of the feeding green indicator. The detector analyses the METHANE gas concentration in the environment every 100 milliseconds, its state is updated when modifications are produced. FAILURE STATE. If the detector shows any type of anomaly, stopping correct operation, the orange indicator for FAILURES is activated in a continuous way. PRE-ALARM STATE. When the level of METHANE gas concentration is over 10% L.I.E., the detector activates (1 time per second) the acoustic alarm and the red indicator for ALARM in an intermittent way. ALARM STATE. If the pre-alarm state is confirmed for 10 consecutive seconds, the detector goes to alarm state, activating the acoustic alarm and the red indicator for ALARM in a continuous way. In case of ALARM. 1. Extinguish the flames. 2. Cut off the gas supply from the gas main control. 3. Do not turn the lights on or off, or any electric unit. Open the windows for ventilation. When the alarm stops, the reason for the alarm to be activated is to be determined and measures are to be taken. If the alarm continues on, and the is no apparent cause for the leak and/or it can not be repaired, vacate the place and IMMEDIATELY NOTIFY the emergency service from a safe place. Gas detectors are accuracy instruments. If required, the acoustic alarm can be silenced by pressing the SW1 pushbutton placed inside the detector. OPERATION RELAY ACTIVATION Operation relay activation is produced 8 seconds after confirming the alarm state. DETECTOR REPLACEMENT.

The detector is automatically replaced when the level of METHANE gas concentration is reduced under 10% L.I.E., and such level is maintained for 5 consecutive seconds. The acoustic alarm, the ALARM red indicator and the operation relay are off. MANUAL OPERATION TEST. A test for the detector correct operation can be carried out by pressing the SW1 pushbutton. To access this pushbutton, the alarm casing needs to be opened. While the pushbutton is pressed, the acoustic alarm, the alarm red indicator and the operation relay are activated. MAINTENANCE Visual inspection is the minimum recommended maintenance work, checking that there are no elements stopping the air circulation through the air vents. Periodical operation test is also recommended. For gas presence to be noticed in a place, LPG and methane gases contain a smelly substance. This smell can be noticed before the detector starts working that, in any case, it has been calibrated below the level of gas explosion. The detector should be installed between 1 and 4 metres from gas appliances. The detector should not be installed in a closed place, for example in a cabinet or behind a curtain, directly under a sink, near a door or window, near an extractor fan, in places where dust and dirt may block the sensor or in wet or humid places. For cleaning, use a slightly wet cloth. Do not use cleaning products as well as solvents, alcohol, bitumen, varnish or paint on the detector or near it as such products may affect the unit reliability. Periodic tests of operation are recommended by pressing the TEST key, in order to check correct operation of the light and acoustic indicators and the outlet, as well as the electrovalve if connected, and checking that the detector air inlets are dust and dirt-free. Do not use another test method, such as the use of gas from lighters or from other devices that could damage the detector sensor beyond repair. The use of a suction device for the cleaning of the air inlets is recommended. The detector outlet may be used for the activation of a cut-off valve on the incoming gas pipe. Such valve will need a manual action for being reset in open position. The valve installation and use is to be in accordance with Regulation EN1775 and domestic regulations. LIFETIME In order to verify the detector lifetime, the installation date is to be marked on the detector side label. The sensor is to be replaced every 6 years from the installation date.

TECHNICAL CHARACTERISTICS AE09/GM AE09/GM-12 AE09/GM-24 Supply voltage: 230V AC 12V DC 24V DC Heating cycle consumption: 13 ma 31 ma 110 ma Standby consumption: 12 ma 13 ma 70 ma Alarm consumption: 14 ma 56 ma 122 ma Classification: Type-A device Relay contacts: C, NC and NA voltage-free. Relay contact maximum current: 8A 250VAC/30VDC Operation indicator Green, fixed activation Heating cycle indicator Activation of Failure (orange) and Alarm (red) indicators alternatively Failure state indicator Orange, fixed activation Pre-alarm state indicator Red and acoustic indication, intermittent activation Alarm state indicator. Red and acoustic indication, fixed activation Acoustic alarm: piezoelectric buzzer, 3300Hz, 85 db Alarm level: 10% L.I.E. METHANE gas(ch 4 ) Alarm confirmation: 10 seconds Relay activation delay: 8 seconds Initial heating period: 120 seconds Temperature range: 0º - +50º C (room temperature). Humidity range: Relative humidity 10% - 90% with no condensation Casing material White ABS Dimensions: 130 x 70 x 52 mm Weight 300 gr 133 gr 137 gr For environment preservation, the electric or electronic unit is not to be treated as domestic waste at the end of its lifetime. Please, make selective collection taking it to specific collecting points for the recycling of electric and electronic units in your town/city. Please, keep these instructions in a safe place..

YOUR NEAREST POINT OF ASSISTANCE AND SUPPLY CENTRAL OFFICE C/ Julián Camarillo, 26 2ª Planta 28037 Madrid Tel: 91 754 55 11 Fax: 91 754 50 98 GAS PROCESSING PLANT Av. Alfonso Peña Boeuf, 6. Pol. Ind. Fin de Semana 28022 Madrid Tel: 91 754 55 11 Fax: 91 329 58 20 NORTHEAST OFFICE C/ Rafael de Casanovas, 7 y 9 SANT ADRIA DEL BESOS 08930 Barcelona Tel: 93 381 08 04 Fax: 93 381 07 58 EAST OFFICE Tel: 628 92 70 56 Fax: 91 754 50 98 NORTHWEST OFFICE C/ José Luis Bugallal Marchesi, 9 15008 A Coruña Tel: 98 114 02 42 Fax: 98 114 24 62 SOUTH OFFICE Edificio METROPOL 3 C/ Industria, 5 3ª Planta Mod.17 Parque Industrial y de Servicios del Aljarafe (P.I.S.A.) 41927 Mairena del Aljarafe Seville Tel: 95 465 65 88 Fax: 95 465 71 71 CANARIES OFFICE C/ Sao Paulo, 17, 2ª Planta. Oficina 3-2-15. Urb. Ind. El Sebadal 35008 Las Palmas de Gran Canaria Tel: 928 24 45 80 Fax: 928 24 65 72 http:// e-mail: comercial@aguilera.es