MORE THAN JUST FIRE PROTECTION

Similar documents
MORE THAN JUST FIRE PROTECTION

VELMIST. System Mgły Wodnej Niskociśnieniowej

FIRE KILL INNOVATIVE FIRE PROTECTION SOLUTIONS

Low Pressure INNOVATIVE FIRE PROTECTION SOLUTIONS in the. Woodworking Industry INNOVATIVE FIRE PROTECTION. VID Fire-Kill. Denmark.

TUNPROTEC. Active Tunnel Fire Protection

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

Watermist Applications and Approvals

CERTIFICATE OF FIRE APPROVAL

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Fire protection for buildings

Performance Based Fire Protection With Water Mist

Watermist Fire Protection of Plant Rooms

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Approved products and systems for water mist systems and VdS 3188 for planning and installation

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Can we use knowledge and experience from other sectors to prove Water mist s suitability for land applications? UK Water Mist Seminar 8th March 2016

Water Mist v Sprinklers

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064

FOREFRONT AT THE OF PROTECTION

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Installation and Maintenance Requirements

PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY

The Science Behind Water Mist Protection of Typical Building Hazards

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

Additional Requirements for Watermist Systems Protecting High-rise Buildings

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Ruhrpumpen Fire Systems

Water Mist Fire Suppression

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

The History of IWMA. 18th International Water Mist Conference will (IWMC) take place in London on 19th & 20th September 2018

automatic FiReFighTing SYSTeMS in PainT booths

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

High Ceiling Protection

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

and Sprinkler System in Resalat Tunnel of Tehran

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

The requirements of BS Watermist Fire System standard and how to demonstrate compliance

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

What is HI-FOG? The natural enemy of fire

Fixed fire protection solutions

OPEN SPRINKLER SYSTEM

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Nessie High Pressure Water Mist Components for Fire Fighting

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

Approval of water mist systems in buildings

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Smoke detection in hazardous areas:

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

Moving Target: A Case Study in Providing Fire Protection Below a Reconfigurable Concert Hall Seating System. Part 1: Concept Design

MSC Guidelines for Automatic Sprinkler Systems

Water Mist and Heritage Buildings Case - St. Mark s Dome, Venice

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

KITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems

Üntel is ready for CPR

S p e c i a l P u r p o s e S p r i n k l e r s. Attic Spaces Retail Windows High Security Institutions Minimal Water Damage Conditions

WATER MIST CONVENTION AND EXHIBITION

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Abu Dhabi Conformity Assessment Scheme for Fire Pumps

Shipboard incinerators with capacities up to 4000 kw

9 Standards, Regulations and Authorities

Fire protection solutions for ships and offshore facilities

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

Update on European Standardization Work

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

SECURITY BLANKET Foam Fire Protection Products

This document is a preview generated by EVS

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

Extreme Fires!

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Zurich s experience case studies

High-pressure water mist systems and fire testing. Max Lakkonen IFAB Institute for Applied Fire Safety Research

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

High pressure water mist sprinkler system for fighting fires

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Sprinkler systems. A presentation for fire brigade staff

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM SAID. DONE!

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Transcription:

MORE THAN JUST

VID Fire-Kill is a world leading innovative developer and manufac turer of waterbased firefighting products, specializing in fixed water-based systems utilizing environmental friendly firefighting methods. WE CARE ABOUT THE ENVIRONMENT We feel obligated to do our utmost to protect the world which is why our products combine high firefighting perform ance and robust and reliable designs, with environmentally sound methods: We offer a large range of successfully tested and approved products matching our customer s individual requirements, and we always strive for the highest possible quality at all times. All our products are unique, offering either a better performance, a better approval or a better solution than what is found on the market today. With the advances in watermist fire protection technology and the continued addidtion of VID Fire-Kill products, approvals and covered applications, we form the spearhead of the fire protection industry. Utilizing water pressures from 2-12 bar helps save energy to run fire pumps, and also enables the use of traditional approved sprinkler components such as pumps, pipes, fittings, hangers, etc. in our systems. 60-80% less water use compared to conventional sprinklers helps save water, and reduces the water damage and potential business interruption occurred with a system activation. FireKill low pressure watermist products shall always give positive value to the end user. Positive value in our eyes is when the total sum of all benefits we supply is larger than the cost of obtaining the system. To create these benefits all our products and systems are created with unique selling points enabling us to provide as much value as possible. In short: We offer a FM approved product range. We offer a CEN with third party witness product range. Land Commercial Land Industrial Heritage Offshore/ Maritime Infrastructure We offer a fully MED and Type approved product range to all IMO watermist standards. We offer the largest product range with most covered variety of applications. We specialize 100% in low pressure watermist solutions. Our production system is ISO 9001 accredited, FM approved and DNV/GL MED-D and Lloyds Register MED-B approved. We have more than 25 years knowhow within watermist R&D, manufacturing and sales. We care about aesthetics! That is why we offer innovative fire protection that you almost cannot see.

The FireKill OH system for commercial land applications is an automatic, concealed lowpressure watermist system ideal for a wide range of domestic and public areas and applications such as: Domestic areas Offices Data processing areas Meeting rooms Hotels Museums Shopping areas Residential areas Institutions Schools Atriums Restaurant seating areas Indoor car-park Storage areas The different finishes and optional painted finishes make the system blend in with almost any type of surface, securing the aestetics of your surroundings. The OH nozzles are combined with the WAC alarm valve. The valves, which are made in bronze, are characterized by being able to detect small flows which are common in watermist systems and also by having an integrated Anti False Alarm feature which reduces the risk of false alarms coming from pressure shocks. The patented FireKill OH range of nozzles are tested and approved to various applications. FireKill OH-VSO is s an automatic, pendent low pressure watermist nozzle tested and approved for HC1/OH1 in accordance with FM 5560, Appendix G. FireKill OH-DR1 is an automatic, pendent low pressure watermist nozzle tested in accordance with CEN/LPCB for domestic and residential with DnVGL third party witness. FireKill OH-UPR is an automatic, upright low pressure watermist nozzle tested in accordance with CEN/VdS for non-automatic, fully enclosed garages, underground garages and such applications with DnVGL third party witness. LAND COMMERCIAL FireKill OH-PX2 is an automatic, pendent low pressure watermist nozzle tested in accordance with CEN/VdS for selected OH-3 sales, storage and technology areas anclosed by OH-1 areas with smooth ceilings and walls with DnVGL third party witness. INNOVATIVE

LAND INDUSTRIAL Internal combustion engines, oil pumps, oil tanks, fuel filters, generators, transformer vaults, gear boxes, MACHINERY SPACE, STORAGE, PUMP ROOMS & CONVEYOR SYSTEMS I N N O VAT I V E F I R E P ROT E C T I O N drive shafts, lubrication skids, diesel engine driven generators, exposed combustion turbine, insulated combustion turbine and other similar equipment using liquid hydrocarbon fuel and/or hydraulic heat transfer The system can be designed with different parameters depending on enclosure size, making it possible to optimize the system for its use. The single open nozzles and the N-pipes system have been tested to a and lubrication fluids with volatility less than or equal to heptane; enclosures with incidental use or storage of long list of different protocols. To proof its use as an protection system, hydrocarbon ignitable liquids (also known as flammable N-pipes have been successfully tested to various DFL test methods with liquids) of not more than two 55 gal (208 L) drums. amendments, all designed accordingly to CEN/EN 14972. Systems are to be fitted with our C-EL FM approved zone valve for either manual or automatic activation by flame and/or heat detectors. FireKill K6 is an open low pressure watermist nozzle suited for fire protection of machinery spaces, special hazard machinery spaces, combustion turbines and insulated combution turbines. The FireKill K6 system is FM approved as it has been successfully tested to the FM5560 standard, appendix E and F in room sizes respectively of 320 m3 (5m ceiling height) 800m3 (8m ceiling height) and 4610 m3 (12m ceiling height) FireKill Model N-pipe is a low pressure fine water spray deluge system, which was created for the protection of many different applications. The N-Pipe is manufactured in different shapes suiting different applications, typically biomass storage, conveyors, wooden industry machines etc. Various options for individually fitted systems i order to meet your exact needs and create the best solution

LIFE SAFETY & STRUCTURE PROTECTION HERITAGE INNOVATIVE The FireKill systems have been tested towards a large range of different protocols, whereas some is specially made for specific applications and some are standard protocols in accordance with authorities. All tests has been carried out in accredited laboratories in accordance with written protocols. The AU7 nozzles have been tested in accordance with the DFL fire test standard No. 90805-01 Full Scale Fire Test Method of Active Fire Protection Systems for Fire Protection of Large Indoor Spaces with Large Multiple Seating Areas by the Danish Fire Laboratories The APS System has been tested in accordance with the Danish Fire Laboratories test method TM 70111-04 for horizontal installed systems designed to protect atriums and other such applications. The FireKill System for heritage building such as old churches, museums, theaters etc. is a combined system including a variety of the FireKill products such as OH nozzles, APS system, KIP system for the attic, facade system for outdoor protection. This makes the system a complete package protecting irreplaceable values. FireKill Model AU7 nozzles have been designed specifically for the fire protection of large indoor spaces with high ceiling heights, which contains moderate fire loads and spaces in which the fire load concentration does not exceed an average of 1MW/m2. FireKill low pressure watermist atrium System Model APS is a system utilizing very small open watermist nozzles integrated in stainless steel pipes, designed specifically for the protection of atriums and other such large rooms.

FireKill Model OH-OPX1 is a patented open, low pressure watermist nozzle for fire protection of car deck and RO-RO space. FireKill Model K6 is a patented open low pressure watermist nozzle for fire protection of machinery space category A and pump rooms. FireKill Model B1 is a patented open low pressure watermist nozzle for fire protection of the bilge area (space between floor plates and tank top) in machinery space cat A and pump rooms. FireKill Model K6-North Sea and Pacific and B1-Bengal for machinery space cat SAFETY AT SEA Aaccording to MSC Circ. 1165 with DnVGL MED-B approval. FireKill Model K6-Skagerak for local application according to MSC Circ. 1387 with LR MED-B approval. FireKill OH-Neptun is a patented range of automatic, pendent low pressure watermist nozzles. They provide a highly reliable and enhanced firefighting performance along with low water requirements, which is typical for the FireKill watermist nozzles. The nozzles are available in custom finishes and optional colored finishes, thus making the FireKill OH-Neptun blend in with almost every type of surface. FireKill Model OH-Neptun for accommodation according to MSC Res 265(84) with DnVGL MED-B approval FireKill Model OH-OPX1 Skagerak and Suez for RO-RO deck in accordance with IMO Circ. 1430 with DnVGL MED-B approval. FireKill Model HS and MS for deluge systems, outdoor and indoor protecting process areas etc, holding FM approval. OFFSHORE/ MARITIME INNOVATIVE

TUNPROTEC is a reliable and robust fast-response fixed fire protection system, designed specially for the protection of infrastructure applications, such as tunnels, etc. The patented TUNPROTEC system includes a double-knock detection system for fast detection of fires with minimal risk of false activations, a low pressure watermist system for controlling and suppressing the fire and an application-tailored control system for ensuring that the system is operational 24/7 and can be easily integrated into tunnel control systems, e.g. SCADA. A full automatic system designed to minimize installation and running costs, while ensuring fast and reliable protection of people and tunnel structures from fires. MORE THAN JUST The TUNPROTEC system ensures environmentally friendly and safe protection of your tunnel complexes with low water and power requirements. By utilizing readily available, standard components in combination with expertly designed essential components, the TUNPROTEC system allows for an easy to install fire protection system at competitive low prices and system requirements without lowering the systems fire protective capabilities. INFRASTRUCTURE INNOVATIVE The TUNPROTEC system has successfully been tested and received various approvals including: MSC circ. 1165 watermist nozzle component test approval FM5560 section valve approval EN54 approval on detection and control system UPTUN 251, NFPA 750 & NFPA 502 compliant UPTUN Full scale fire testing 3 MW - 28 MW Runehamar Full scale fire testing 30 MW - 100 MW TUNPROTEC has the capability to prevent and control temperature buildup and its ability to minimize back layering in tunnel fires is impressive. The TUNPROTEC system effectively returns the thermal expansion of the smoke and temperature buildup to minimal values within the first minute after activation, reducing temperatures from 400 C to < 60 and completely stopping the development of back layer. By preventing these two devastating factors, the TUNPROTEC system prevents potential catastrophic fires from developing and allows firefighters to enter the site and actively fight the fire almost immediately after system activation. Learn more about TUNPROTEC from the TUNPROTEC website - www.tunprotec.com.

A P P R O VA L S I N N O VAT I V E THE NECESSARY DOCUMENTATION F I R E P ROT E C T I O N All FireKill products are developed and manufactured in our ISO 9001 accredited production located in Denmark. We also hold the EC Directive Module D certificate from the Marine Equipment Directive (MED), and our production and management system is verified by Factory Mutual, DNV and Lloyds Register. In other words, FireKill equals state of the art and internationally recognized fire protection holding several approvals. Watermist, still being a commercially young technology, needs good documentation to get accepted by the AHJs. Since watermist needs fire testing to determine the system specific data, it is often the test data which is required, however the problem with this is that it can be difficult for non-related watermist people to read and understand test data. For the same reason most AHJs require approvals because it becomes easier to accept the result. A notifying body approval from FM, VDS, UL, DNV, etc. will consist of a listing which is fully controlled. This means that they list the system on a public webpage where everybody can verify that the approval exists and is valid. To get such a watermist approval the system has to undertake four approval parts: Fire testing of the system Component testing of the system components Approval of the system DIOM, drawings, technical literature. Approval of the production facilities

VID Fire-Kill ApS Svalbardvej 13 5700 Svendborg Denmark Tel.: 6262 1024 Fax: 6262 3661 www.vid.eu sales@vidaps.dk This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. VID Fire-Kill ApS and its subsidiaries assume no responsibility for any errors that may appear in the publication, or for damages arising from the information in it. No information in this publication should be regarded as a warranty made by VID Fire-Kill ApS. The information in this publication may be updated without notice. Product names mentioned in this publication may be trademarks. They are used for identification purposes only. 01.2018.