BenchTOF. The next generation of time-of-flight mass spectrometers for GC and GC GC

Similar documents
Detailed characterisation of essential oils by flow-modulated GC GC TOF MS with Tandem Ionisation

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

An Introduction to Mass Spectrometry

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

Technical specifications of FT-IR Spectrometer

Mobile CWA Detection and Identification. Innovation with Integrity. Mobile Mass Spectrometer MM2 CBRNE

get mass. without massive work. [ 3100 MASS DETECTOR ]

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

This document is a preview generated by EVS

IMPROVING THE QUANTITATIVE REPRODUCIBILITY OF AN ATMOSPHERIC PRESSURE CHEMICAL IONISATION SOURCE FOR GC/MS AND GC MS/MS ANALYSIS

Datalogging as standard

Hiden HPR-20 QIC EGA for evolved gas analysis in TGA-MS

On Line SPE LC/MS/MS Applications

detectors UltiMate 3000 Variable Wavelength Detectors

intrinsically safe detector for hydrocarbon gases

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

300 series HPLC autosamplers

ice 3000 Series Atomic Absorption Spectrometers

Soft Ionisation Techniques, Terry Whitmore, Hiden Analytical

Standoff CWA/TIC Detection. Innovation with Integrity. Toxic Gas/Vapour Threat Mitigation RAPIDplus CBRNE

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

[ ACQUITY QDa DETECTOR ] SEPARATING BEYOND QUESTION BRINGING THE POWER OF MASS DETECTION TO YOU

Software-Aided Operation of Modern Industrial Leak Detectors

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

ProStar 325 UV-Vis Detector

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

CALIDUS tm the Modular micro Gas Chromatograph

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Application Note CBRNE Stand-Off Detection of Toxic Industrial Chemicals in Industrial Complexes Using RAPIDplus

RIID capability in the palm of your hand

Metal Detection. Total Protection For You and Your Customers SAFELINE

PG 990 Atomic Absorption

FIXED GAS ANALYZER (FGA)

Application Note. Authors. Abstract

Chemical Threat Detection. Innovation with Integrity. Integrated CWA/TIC detection and identification: Bruker RAID-S2plus CBRNE

High resolution mass spectrometry (HRMS*) in Graz

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

HISTORY OF VARIAN CAPILLARY INJECTORS

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

AAnalyst 700 Atomic Absorption Spectrometer

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

Sensitive Determination of Microcystins from Environmental Waters Using On-Line SPE

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Automated Infrared Thermography Complete Solutions from a Single Source

Altanium Temperature Controllers

ETHOS UP HIGH PERFORMANCE MICROWAVE DIGESTION SYSTEM MILESTONE

Fixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications

LSM Quadrant Source and Measure Unit for LED Production Tests. Two Global Leaders. One Complete Solution.

Recent Improvements in Process GC Instrumentation

HPLC Column Ovens and Temperature Controllers

Chemistry Instrumental Analysis Lecture 29. Chem 4631

Hiden QGA Quantitative Gas Analysis System

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Metal Detection. High Performance Metal Detection Delivering Efficiency and Reliability SAFELINE

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Process Gas Chromatograph

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

RAID-S2. Innovation with Integrity. Stationary Rapid Alarm and Identification Device. Defence CBRNE

July 13, Reducing False Positives When Monitoring for Low Concentrations of Airborne Organic Chemicals in the Workplace

GOLD RX/HC. The air handling unit with a reversible heat pump. Ventilation, heating and cooling all in one

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

Installation Manual. Humidifier for CIA Advantage. Version 1.1. March 2013

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Soxtec 200 series Solvent Extraction Solution

Model S FT-IR SPECTROMETER

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

Intelligent Signature Series Analog Detection

Compact Product Suite Compact HMI 6.0 Overview ABB

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS

SOLUTION MINING RESEARCH INSTITUTE

A660 Air Conditioning Laboratory Unit

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

LHCb Rich Detectors Control and High Voltage Systems

COMPLETELY AUTOMATED HYDROLYSIS

Fire & Security Products. Siemens Flame Detector a highlight in detection. technology.

An FT-NIR Primer. NR800-A-006

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

Transcription:

BenchTOF The next generation of time-of-flight mass spectrometers for GC and GC GC

BenchTOF Delivering unparalleled confidence for sample characterisation A BenchTOF for every application... Outstanding performance for every GC and GC GC application, unbeatable productivity and enhanced quality of results come as standard with every BenchTOF. High-definition TOF MS Take the next step up in GC MS and harness the SIM-level sensitivity and full spectral information available with BenchTOF-Evolve, while keeping the user interface you re familiar with. 4 ev M + Tandem Ionisation If you re in a high-throughput or QA/QC laboratory, BenchTOF-HD with TOF-DS software gives you the outstanding productivity you need, whatever your GC (or GC GC) application. If you d love the extra confidence in sample characterisation that comes with Tandem Ionisation, then choose BenchTOF-Select. Join the growing number of laboratories worldwide, and discover what BenchTOF can bring to your analysis. GC GC solutions

Innovative technology, unique design The unique design of BenchTOF opens up possibilities that cannot be achieved with other GC MS techniques. BenchTOF instruments incorporate the latest advances in mass spectrometry, including Tandem Ionisation for confident identification and unparalleled productivity. Additionally, novel software developments, including the ChromSpace GC GC data processing module for BenchTOF, enable simple workflows for evolving your laboratory s capabilities. The combination of these advances, with the inherent sensitivity and spectral quality of BenchTOF, delivers the analytical resolution required to tackle even the most challenging analyses. Tandem Ionisation Exclusive to Markes, Select-eV allows you to collect soft EI spectra down to ev, with no inherent loss in sensitivity and full automation in TOF-DS software with no need for manual intervention. Tandem Ionisation now adds unparalleled productivity for soft ionisation. Soft and hard ionisation spectra are obtained across every peak, in both GC and GC GC analyses, for comprehensive sample characterisation in a single run. Caryophyllene 2 ev 4 55 8 79 69 94 9 2 33 One chromatographic peak, two complementary spectra. Rapid switching of ionisation energy enables reference-quality and soft EI spectra to be obtained simultaneously, without user intervention and in a single workflow. 93 6 2 33 48 48 6 6 75 89 24 The combination of GC GC and mass spectra at low and high ionisation energies confers unparalleled power to identify specific isomers within our chromatograms Dr M. Salim Alam School of Geography, Earth and Environmental Sciences, University of Birmingham, UK

High-definition TOF MS Changing the way you think about TOF MS Every BenchTOF instrument offers an unbeatable combination of sensitivity, spectral quality, selectivity, speed and stability, which together deliver high definition mass spectrometry a powerful approach to any GC MS or GC GC MS application. Outstanding sensitivity Confident identification Instrument detection limit (IDL) calculated using fg OFN = (t RSD concentration)/ = (2.998.6 )/ = 32 fg 8 57 2 393 47 42 435 449 M + Relative abundance (%) 8 6 Intensity ( 5 counts) 6 4 43 7 85 463 477 49 55 59 533 4 45 5 55 562 4 2 99 327 5.26 5.28 5.3 5.32 5.34 Retention time (min) 2 3 4 5 m/z Outstanding results for trace-level analysis of targets and unknowns are possible with BenchTOF. Time-of-flight instruments are not mass filters and simultaneously analyse all ions. When combined with the highly efficient direct extraction ion source in BenchTOF, this boosts sensitivity to the level normally encountered in selected ion monitoring (SIM) mode as illustrated by the calculated IDL from repeat injections of octafluoronaphthalene (OFN). Unlike other TOF mass spectrometers, the spectral quality of BenchTOF results in excellent matches to classical quadrupole spectra in commercial or custom libraries. In this example, the spectrum of tetracontane (C 4 H 82 ) shows preservation of the molecular ion.

Enhanced data clarity Flexibility for fast GC and GC GC Intensity ( 7 counts) 4 2 TIC 5 5 2 25 Time (min) Intensity ( 5 counts) EIC (m/z 269 ±.5) 5 5 2 25 Time (min) High-speed spectral acquisition provides information-rich datasets which allow enhanced data-mining, and ensure compatibility with fast GC and GC GC. The transition to GC GC is now even easier with the ChromSpace data processing plug-in for TOF-DS. 2.. Second-dimension retention time (s) 2 3 4 5 6 First-dimension retention time (min) Precise identification of target compounds becomes possible when sub-unit mass selectivity is used to eliminate matrix interferences as illustrated here for identification of the herbicide alachlor in a river water extract. Signal-to-noise ratios are also dramatically improved, enhancing quantitation of trace-level analytes in complex matrices. Intensity ( 5 counts) EIC (m/z 269.8 ±.4) 5 5 2 25 45 45 Forward match: 97 Reverse match: 93 77 77 MeO 46 9 58 32 9 N 8 32 46 Cl O Time (min) 6 6 88 88 224 237 224 237 Alachlor BenchTOF 269 269 NIST Minimal maintenance The exceptional stability of BenchTOF reduces the need for maintenance, minimising downtime and improving productivity as demonstrated here by the relative standard deviations obtained over the course of a month for a fragrance mix. Even with no intermediate instrument tuning, the ISTD-corrected area responses for 23 injections show minimal variation. ISTD-corrected area response..8.6.4.2 β-pinene 2.% RSD Benzyl acetate 2.% RSD Neomenthol 5.3% RSD Dihydromyrcenol 5.8% RSD 2 3 4 Time (weeks)

BenchTOF-Evolve A stepping-stone to time-of-flight mass spectrometry. For laboratories attuned to routine GC MS workflows, BenchTOF-Evolve provides a refreshingly straightforward way of realising the benefits of TOF mass spectrometry. The software package that comes with BenchTOF Evolve provides full instrument control, but minimises any training requirements by allowing you to process the data in your familiar software environment. Also supplied as standard is Markes TargetView platform for powerful peak deconvolution and compound identification in challenging samples. TargetView (.lsc,.cdf,.d,.raw) Clarity (.cdf) MassHunter (.d) TraceFinder (.raw) ChemStation (.d) Chromeleon (.raw) Xcalibur (.raw) Familiar data-processing protocols such as Agilent s ChemStation package (shown here) can be used to analyse data generated by BenchTOF-Evolve, thanks to the ability to save data files in a range of file formats. BenchTOF-Evolve also fits seamlessly into any laboratory, delivering enhanced data confidence with no impact on workflows.

BenchTOF-HD Powerful features for improved laboratory workflow The needs of demanding high-throughput laboratories are exceeded, thanks to the TOF DS software package that comes as standard with every BenchTOF-HD and BenchTOF-Select. In addition to full instrument control, you ll be able to enjoy the benefits of automated, real-time data-processing with immediate display and reporting of results and unlockable parameters for fast sequencing and rapid method development. Large-scale data screening and comparison of complex GC MS profiles is also simplified with the innovative ChromCompare module. An icon-based method overview in TOF-DS makes setup easy. Background Autosampler GC BenchTOF Raw data subtraction Integration Library search Quant & reporting Real-time data processing Peak list Peak spectrum The fast qual-to-quant workflow in TOF-DS makes it easy to import target compounds, quant ions and retention time windows from a spreadsheet. Auto-propagating peak tables With real-time data processing, automated integration, deconvolution and library-searching can all be set to happen while the sample is still acquiring. Source EIC showing the identified peak The results browser shows all the quantitative information on one screen including compound list, sample list, calibration curve and graphics for the identified peak and associated internal standard (such as EIC overlays and spectra).

M + 4 ev Tandem Ionisation A ground-breaking advance in MS Tandem Ionisation adds to the already innovative technology featured in all BenchTOF instruments, by incorporating a novel ion-source design for simultaneous collection of hard and soft EI spectra. With Tandem Ionisation you can enjoy effortless real-time visualisation of results within TOF-DS software, improved detection limits and additional confidence in compound identification using qualifier ion ratios at both and low ev. Powered by a unique flight-box design Reference-quality spectra for confident identification are generated thanks to the ion source floating at 3 kv, minimising differences in ion impact velocities at the detector. A compact design means that BenchTOF is easily accommodated in any laboratory. Designed from first principles for optimum performance, the compact BenchTOF flight-box eliminates issues historically associated with TOF MS. Full sample characterisation is achievable in a single run, with the unique ion-source design featuring Select-eV soft electron ionisation and Tandem Ionisation mode. SIM-like sensitivity for targets and unknowns is achieved using efficient direct extraction of ions from the source. Multi-stage reflectron optimises resolution.

Simple integration of soft EI into laboratory workflows within TOF-DS Autosampler GC BenchTOF Raw data Data file Integration Background subtraction method 4 ev method Quant & reporting Library search Tandem ionisation is fully integrated into the TOF-DS method workflow, with a simple graphical overview used to display each step from instrument control all the way through to reporting of results. Here we show the use of Tandem Ionisation at 7 and 4 ev, culminating in quantitative results for both ionisation energies. Improved detection limits with soft EI Peak area ( 4 counts) 3 2 4 ev R 2 =.9984 5 5 2 8.3 8.35 8.4 Concentration (ng/l) R 2 =.9974 Intensity (counts) 6 4 2 4 ev Retention time (min). pg Bu 3 SnEt EIC (m/z 29) Unlike other soft ionisation techniques, the repeatability of soft EI is comparable to that of, meaning that robust quantitation can be performed. Reduced background noise and enhanced quantitation ions also improve detection limits as illustrated here, where the LOD achieved for a tributyl tin derivative (Bu 3 SnEt) in a water extract fell from pg at, to just. pg at 4 ev.

BenchTOF-Select Harness the power of Tandem Ionisation for full sample characterisation in a single run. With Tandem Ionisation, two complementary sets of spectra are continuously acquired, aiding the rapid characterisation of targets and unknowns in a single run. In addition, the robustness of BenchTOF systems allows you to use ion ratios between low-ev and spectra as an additional qualifier for compound identification, prior to sample quantitation and reporting. 2,2,4,6-Tetramethylbenzene 34 2 ev 9 Intensity ( 7 counts) 2 ev 4 5 65 77 9 5 9 34 2 3 5 5 2 25 Retention time (min) Two perfectly aligned chromatograms are generated using Tandem Ionisation, as for this example of gasoline, enabling fast exploration of hard and soft ionisation data. A library of soft ionisation spectra is provided with every BenchTOF Select, to help rapidly integrate Tandem Ionisation into laboratory workflows.

Ultimate confidence in isomer identification Similar terpenes in fragrance and aroma profiles can be difficult (or impossible) to speciate based on conventional electron ionisation alone. Tandem Ionisation adds an additional level of confidence in such situations, but with no inherent loss in sensitivity, or inconvenience to the operator. It also fits seamlessly into laboratory workflows, providing independent checks of ion ratios at and low ev, and between spectra, for robust quality control. Speciation of isomers indistinguishable at 36 (2E,6E)-Farnesol 8 (2Z,6E)-Farnesol Intensity ( 7 counts) 2 ev 4 55 69 69 8 8 93 93 9 2 9 6 9 OH 2 ev 222 4 55 69 69 8 95 93 9 22 36 27 6 48 9 24 9 OH 2 ev 222 2 4 6 8 Retention time (min) 69 8 93 84 22 36 9 6 48 (2E,6Z)-Farnesol 7989 24 2 ev 222 69 8 93 9 22 36 6 (2Z,6Z)-Farnesol 2 ev 7689 24 222 Conventional and soft EI spectra can be acquired simultaneously in a single run using Tandem Ionisation. The result as shown in this example of a fragranced detergent is two complementary datasets, enabling enhanced characterisation of compounds that are impossible to speciate using just data, such as the four isomers of farnesol. 4 55 69 8 93 7 OH 4 55 69 8 93 9 OH

GC GC solutions Integrated instrument control and data processing The new ChromSpace software module allows you to enjoy all the benefits of TOF-DS including full instrument control and fast method development while also exploring and processing your GC GC MS files within a single software platform. ChromSpace uses the same clean, icon-based layout as TOF-DS, further simplifying the transition to GC GC. Key features include: Dynamic and targeted deconvolution modes to expose hidden peaks. Simultaneous acquisition and processing of MS and single channel data, e.g. FID. Simplified, user-friendly quantitative workflow. Customisable layout to suit all users. ChromSpace for unparalleled productivity Instant library match provided when clicking on a peak. Colour scaling immediately normalises upon zooming. Fully customisable layout to suit all users. Sectional plots present unfolded chromatograms in a classical format. Peak table dynamically links chromatograms and spectrum pane for rapid data exploration. ChromSpace is the ideal choice for exhaustive screening of complex samples. A unique combination of peak perception algorithms ensures that even trace/masked peaks are not overlooked or incorrectly merged.

Compatibility with multiple modulators The platform-neutral design of BenchTOF means that you re not restricted to using a specific GC GC modulator. As a result, the best modulator can be chosen for your application with flow-modulated and thermally-modulated technologies being the most popular. Flow modulation Thermal modulation Has lower running costs. Enables efficient modulation of volatiles. Shows excellent between-sample and between-instrument repeatability. Can also be configured for heartcutting two-dimensional GC. Allows easy implementation of parallel detection. May involve more complex method optimisation. Has higher running costs. Is the most popular modulator, with a wide user base. Is often restricted to analytes boiling above C 4. Has a high peak capacity and enhanced signal-to-noise ratios due to narrower peak widths. Offers simple method development. Second-dimension retention time (s) 8 7 6 5 4 3 2 Second-dimension retention time (s) 5 4 3 2 Caffeine 5 5 2 25 3 35 4 First-dimension retention time (min) 2 3 4 5 6 7 8 First-dimension retention time (min) Efficient and repeatable analysis of volatiles in tobacco smoke was achieved using thermal desorption coupled with flow-modulated GC GC TOF MS. Optimisation of parameters revealed the complexity of this challenging whole-smoke sample, without the hassle and expense of liquid cryogen. Over 3 components were detected in this coffee extract using the high separation capacity of thermal modulation with cryofocusing, resulting in peak widths as narrow as 4 ms. Note the (predictably) high level of caffeine.

Confident screening of targets and unknowns in a single run The combination of sensitivity, spectral quality and speed makes BenchTOF-HD, coupled with GC GC, the perfect solution for routine GC GC MS work. In a single run, both targets and unknowns can be separated and confidently identified, making this technique ideal for both investigative work such as monitoring emerging contaminants and target-focused studies. Comprehensive screening of environmental pollutants Second-dimension retention time (s) 4 3 2 PAHs PCBs Pesticides 79 8 53 53 8 79 BenchTOF 4 77 9 263 237 73 73 237 263 5 28 43 55 7 85 98 23 BenchTOF 345 38 345 38 NIST 243 258 229 Dieldrin Forward match: 835 Reverse match: 84 Cl Cl Cl Cl Cl Cl Galaxolide O Forward match: 89 Reverse match: 9 5 2 25 3 35 4 45 5 55 4 NIST 77 9 5 28 43 55 7 85 98 228 23 258 O First-dimension retention time (min) 79 As well as identifying individual chemicals in three important groups of target compounds (PCBs, PAHs and pesticides), this entire water extract was screened for emerging contaminants, such as the polycyclic musks associated with cosmetics (circled). Confident matching against commercial or in-house MS libraries allows fast screening of targets and unknowns.

An extra dimension of information for exhaustive sample characterisation Tandem Ionisation, by simultaneously acquiring and soft EI spectra, complements the separating power of GC GC for example, by enabling in a single run the improved speciation of hydrocarbon isomers that is crucial for robust chemical fingerprinting. Alongside this is the outstanding analytical resolution required to tackle even the most complex petrochemicals, courtesy of the speed, sensitivity and the unique soft electron-ionisation capability of BenchTOF-Select. Additional confidence in chemical fingerprinting Isomer elucidation by low-ev TOF MS. 7 57 7-Methyloctadecane 3 83 85 99 27 4 ev 55 4 69 239 253 43 97 2 225 268 99 268 Untargeted screening by TOF MS. Unlike thermal modulation, flow modulation allows optimal retention-time alignment of MS and FID data sets to be easily achieved, enabling single-run qualitative and quantitative analysis. 85 43 7 3 57 83 7 2-Methyloctadecane 85 57 225 99 27 3 4 4 ev 55 69 43 83 2 239 253 268 268 99 85 43 7 225 57 When used with Tandem Ionisation, dual MS/FID detection (widely employed in the petrochemical industry) pushes the boundaries of hyphenated systems by allowing three information-rich datasets to be acquired in a single run. Robust quantitation by FID. 43 43 7 57 Nonadecane 85 268 4 ev 99 3 27 4 55 69 83 97 2 225 239 268 99 85 7 57

Markes International UK: Gwaun Elai Medi-Science Campus, Llantrisant, RCT, CF72 8XL T: +44 ()443 23935 US: 26-D Kenwood Road, Cincinnati, Ohio 45242 2355 Gold Meadow Way, Gold River, Sacramento, California 9567 Germany: Schleussnerstrasse 42, D-63263 Neu-Isenburg, Frankfurt T: +49 ()62 8825569 E: enquiries@markes.com W: www.markes.com T: 866-483-5684 (toll-free) L-3 (566-5) BenchTOF, BenchTOF-Select, BenchTOF-Evolve, BenchTOF-HD, TargetView and TOF-DS are trademarks of Markes International. ChromCompare, ChromSpace, Tandem Ionisation and Select-eV are registered trademarks of Markes International. Chromeleon, TraceFinder and Xcalibur are trademarks of Thermo Fisher Scientific. Clarity is a registered trademark of DataApex. ChemStation and MassHunter are trademarks of Agilent Technologies.