Dale Power Solutions Ltd

Similar documents
Loadstar AC/DC Systems

Wall Mountable Electric Fireplace with remote control

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Constant voltage charger. Type UP 610. »We store the world's energy« Network

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Excel-EN Conventional Fire Control Panel

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

Installation, Operating and Maintenance Manual

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

PMD-MXT -XX -XXX. Ordering Example. Model Input Channels Input Type. THC Thermocouple channels channels channels RTD RTD

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

RE-PR3-E-27 3-Phase Panel Mount 27kW

PSN-1000 & PSN 1000(E) Installation Manual

TRENCH HEATING LIMITED

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

OPERATION AND INSTALLATION MANUAL

EMEX 110 and EMEL. EMEX 110 and EMEL. 110, 50 and 24 volt AC/DC Central Battery Systems. EMEX 110 and EMEL

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

FLOAT BATTERY CHARGERS

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

IGD.CO.UK

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

SOLU T IONS / PRODUCT OVERVIEW

NEO XL NEO XL NEO XL POWER SUPPLIES - MADE IN SWEDEN ENGLISH

FP EZ4F 4 Zone Controller

AUTOMATION. Operator s Manual LOE-2126 LOE-3136 LOE Internet Enabled Ultrasonic Sensor. Rev. B, 1/12

INPUT / OUTPUT MINI MODULES

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

1/2 CONDENSATE TRAP INDEX

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Installation and user manual for the BiWire / Conventional Repeater Panel

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

» EN50171» Lighting» Reliable

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

ECC-50/100C. Emergency Command Center

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

TECHNICAL DATA OBSOLETE

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

UNIVERSAL PUMP CONTROLLER

Specification/ Data Sheet

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Intelligent Security & Fire Ltd

AL800ULADA. NAC Power Extender. Installation Guide

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

N9 Smart Driveway Alarm User Manual

LIVING INNOVATIONS ENG PRODUCT CATALOG

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Commercial and Light Industrial Fire Alarm Control Panel

DICTATOR Hold-Open Systems for Hazardous Areas

Installation Guide for models:

ZXSe Range Data Sheet

INSTRUCTIONS WATER CHILLERS. Active Aqua Chiller, 1/10 HP. Active Aqua Chiller, 1/4 HP. DISTRIBUTED BY

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

UNIVERSAL PUMP CONTROLLER

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

BOOSTER PUMP SYSTEMS PROCESS & CHEMICAL FEED EQUIPMENT

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Door Release Power Supply

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

UNIVERSAL PUMP CONTROLLER

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Intelligent Security & Fire Ltd

ET10 Series Stand-alone LCD Fan Coil Thermostat

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

Process Alarm Module RTA 421

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Conventional Fire Alarm System Product Range Guide

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Flopurge TS. Operation Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Chair Side Unit (CSU) Includes CSU Models: 320, 351, 356, 362, 370, 3351 & AP 11

Installation Guide for models:

WHITE PAPER: IMPROVED RELIABILITY AND SAFETY IN A NEW STATE OF THE ART FABWIDE HEAT SOURCING AND CONTROL SYSTEM

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

GS100M Gas Detection Controller

Multi-Gas-Controller MGC2

Smart Series TAS-05-11, TAS-05-12

BX444-Mc Gas Detector

Constant voltage 3-phase rectifier.

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Transcription:

DC THYRISTOR SYSTEMS DATASHEET Features Erskine Single Phase Input DCV Range 24V, 48/50V or 110V nominal Up to 63 Amps per charger Constant voltage/current limited output Standard alarm module LCD metering LED indica ons Use with lead acid or nickel cadmium ba eries Parallel opera on capability Input and output voltage op ons Custom alarm configura on op ons Control & distribu on op ons Enclosure & paint colour op ons Product Range Standard Range & Base Enclosures Current Rating 24VDC 48/50VDC 110VDC 6A WM3 WM3 WM3 10A WM3 WM3 WM3 16A WM3 WM3 WM3 20A WM3 WM3 WM4 25A WM3 WM3 WM4 32A WM3 WM4 FSA66 40A WM3 WM4 FSA66 50A WM4 WM4 FSA66 63A FSA66 FSA66 FSA66 Enclosure Type Style Height Width Depth WM3 Wall Moun ng 600mm 600mm 350mm WM4 Wall Moun ng 800mm 600mm 350mm FSA66 Floor Standing 2050mm 600mm 623mm.

Standard Specifications AC Input Supply phase & voltage: Supply voltage varia on: Supply frequency: Supply frequency varia on: Protec on and isola on: Power factor: Single phase 230V +/- 10% to meet output specifica on 50 / 60Hz +/-6% to meet output specifica on, +/- 10% transient MCB, D characteris c 0.8 lagging at full load and float voltage se ng DC Output Nominal voltages available: 24VDC, 48/50VDC, 110VDC Voltage se ng ranges: Float 100 125%, Equalise 110 135%, Commission 120 145% Sta c voltage regula on: Current limit se ng range: +/-1% voltage, for output voltages up to 120% of nominal 10 100% of rated current for float, equalise and commission se ngs Sta c current regula on: +/-2% Regula on characteris c: Ripple voltage: IU according to DIN41773 <1% rms of nominal dc voltage ra ng when connected to a ba ery of Ah capacity Efficiency: 75% to 93% depending on ra ng and any op ons fi ed Mechanical Protec on ra ng: Enclosure finish: Cooling: Audible noise level: Cable entry: IP40 Pale grey RAL7035 textured Natural convec on 55 65dBA depending on ra ng and load Bo om for floor standing enclosures Top wall mounted enclosures.

General Opera ng temperature range: -10 C to +40 C Opera ng temperature de-rate: Up to 55 C de-rate output current by 1% per 1 C Storage temperature range: -20 C to +70 C Opera ng al tude: 0 to 1000m Opera ng al tude de-rate: Up to 3000m de-rate output current by 1.9% per 500m Opera ng humidity: 10% to 90% RH non condensing Safety: BS EN 62040 1-2 EMC: BS EN 62040-2 Alarm & Monitoring DAU Standard systems: Controls: Display: Alarm & status indica ons: Remote alarm: Automa c equalise charge: Flexible configura on: Remote alarm relay op on: Equipped with the Erskine DAU (DC Alarm Unit) module. Equipped with 8 pushbu ons for display page naviga on, configura on and charger mode control. LCD display with 4 line x 20 characters providing charger output voltage, current and status informa on 10 dedicated LED s providing Supply On, Supply Fail. Equalise, DC Low Volts, DC High Volts, Earth Fault, Charger Fail, High Voltage Trip, High Ba ery Impedance, and Fault indica ons. Configurable SPCO volt free relay contact. Provides automa c med equalise charge following a charge failure. Configurable alarm trip, reset and mers. Individual alarms selectable e to be auto reset or latched. 5 spare auxiliary alarm inputs. Selectable mapping of alarms to remote relay. Op onal remote alarm relay for up to 8 individual relay contacts DCV Charger Typical Internal Layout.

Options Addi onal analogue metering Extra configurable remote alarm relay contacts Special DC output voltages, op onal nominal 12VDC, 30VDC, 60VDC, 120VDC Special AC input voltages, op onal nominal 220 250VAC, 380 440VAC, 480VAC, 660VAC Customer specific distribu on isolators, circuit breakers or fuses Charger and/or ba ery isola on An condensa on heaters 2mV CCITT smoothing for 12, 24, 40 or 48/50VDC output systems Output blocking diodes for parallel opera on Counter EMF diodes for parallel opera on Counter EMF diode systems for loads sensi ve to high charge voltages Ba ery charge voltage temperature compensa on (NTC) Different ba ery technologies i.e. VRLA, vented lead acid or wet NiCd Low DC voltage load disconnect facility Ba ery autonomies to suit customer requirements Ba ery fuse boxes, enclosures and stands Ba ery reverse polarity protec on increased panel protec on ra ngs up to a maximum of IP54 Top or bo om cable entry Custom cubicle sizes for more complex solu ons and special enclosure paint colours Larger cubicle sizes for more complex solu ons DCV Charger Single Line Diagram Dale Power Solu ons Ltd reserves the right to make changes in specifica on without no ce or liability. All informa on is subject to Dale Power Solu ons own data & is considered accurate at me of publishing..

DC THYRISTOR SYSTEMS DATASHEET Features 24V Charger ra ngs available from 80A up to 250Amps output Erskine Single Phase Input CV Range 48/50V Charger ra ngs available from 80A up to 125Amps output 220V Charger ra ngs available from 10 to 25Amps output Constant voltage/current limited output Standard alarm module LCD metering LED indica ons Use with lead acid or nickel cadmium ba eries Parallel opera on capability Input and output voltage op ons Custom alarm configura on op ons Control & distribu on op ons Enclosure & paint colour op ons Product Range Standard Range & Base Enclosures Current rating 24VDC 48/50VDC 220VDC 10 to 25A FSA66 32 to 63A 10 to 63Amps available in the DCV product range 80A FSA66 FSA66 100A FSA66 FSA66 125A FSA66 FSA66 160A 200A 250A FSA66 FSA66 FSA66 Enclosure Type Style Height Width Depth FSA66 Floor Standing 2050mm 600mm 623mm

Standard Specifications AC Input Supply phase & voltage: Single phase 230V Supply voltage varia on: +/- 10% to meet output specifica on Supply frequency: 50 / 60Hz Supply frequency varia on: +/- 6% to meet output specifica on, +/- 10% transient Protec on and isola on: MCB, D characteris c Power factor: 0.8 lagging at full load and float voltage se ng DC Output Nominal voltages available: 24VDC, 48/50VDC, 110VDC, 220VDC Voltage se ng ranges: Float 100 125%, Equalise 110 135%, Commission 120 145% Sta c voltage regula on: +/-1% voltage, for output voltages up to 120% of nominal Current limit se ng range: 10 100% of rated current for float, equalise and commission se ngs Sta c current regula on: +/-2% Regula on characteris c: IU according to DIN41773 Ripple voltage: Efficiency: <1% rms of nominal dc voltage ra ng when connected to a ba ery of Ah capacity 4 x charger output ra ng 75% to 93% depending on ra ng and any op ons fi ed Mechanical Protec on ra ng: IP40 Enclosure finish: Pale grey RAL7035 textured Cooling: Natural convec on Audible noise level: 55 65dBA depending on ra ng and load Cable entry: Bo om for floor standing enclosures

General Opera ng temperature range: -10 C to +40 C Opera ng temperature de-rate: Up to 55 C de-rate output current by 1% per 1 C Storage temperature range: -20 C to +70 C Opera ng al tude: 0 to 1000m Opera ng al tude de-rate: Up to 3000m de-rate output current by 1.9% per 500m Opera ng humidity: 10% to 90% RH-non condensing Safety: BS EN 62040-1-2 EMC: BS EN 62040-2 Alarm & Monitoring DAU Standard systems: Controls: Display: Alarm & status indica ons: Equipped with the Erskine DAU (DC Alarm Unit) module. Equipped with 8 pushbu ons for display page naviga on, configura on and charger mode control. LCD display with 4 line x 20 characters providing charger output voltage, current and status informa on 10 dedicated LED s providing Supply On, Supply Fail. Equalise, DC Low Volts, DC High Volts, Earth Fault, Charger Fail, High Voltage Trip, High Ba ery Impedance, and Fault indica ons. Remote alarm: Automa c equalise charge: Flexible configura on: Remote alarm relay op on: CV Charger Typical Internal View Configurable SPCO volt free relay contact. Provides automa c med equalise charge following a charge failure. Configurable alarm trip, reset and mers. Individual alarms selectable e to be auto reset or latched. 5 spare auxiliary alarm inputs. Selectable mapping of alarms to remote relay. Op onal remote alarm relay for up to 8 individual relay contacts

Options Addi onal analogue metering Extra configurable remote alarm relay contacts Special DC output voltages, op onal nominal 12VDC, 30VDC, 60VDC, 120VDC Special AC input voltages, op onal nominal 220 250VAC, 380 440VAC, 480VAC, 660VAC Customer specific distribu on isolators, circuit breakers or fuses Charger and/or ba ery isola on An condensa on heaters 2mV CCITT smoothing for 12, 24, 40 or 48/50VDC output systems Output blocking diodes for parallel opera on Counter EMF diodes for parallel opera on Counter EMF diode systems for loads sensi ve to high charge voltages Ba ery charge voltage temperature compensa on (NTC) Different ba ery technologies i.e. VRLA, vented lead acid or wet NiCd Low DC voltage load disconnect facility Ba ery autonomies to suit customer requirements Ba ery fuse boxes, enclosures and stands Ba ery reverse polarity protec on increased panel protec on ra ngs up to a maximum of IP54 Top or bo om cable entry Custom cubicle sizes for more complex solu ons and special enclosure paint colours Larger cubicle sizes for more complex solu ons CV Charger Single Line Diagram Dale Power Solu ons Ltd reserves the right to make changes in specifica on without no ce or liability. All informa on is subject to Dale Power Solu ons own data & is considered accurate at me of publishing.