Excellent ECODAN s heating performance, even at low outdoor temperature!

Similar documents
Excellent ECODAN s heating performance, even at low outdoor temperature!

Excellent ecodan s heating performance, even at low outdoor temperature! Small capacity. Packaged type. Small capacity (Under 5kW)* SUHZ-SW45

Excellent ecodan s heating performance, even at low outdoor temperature! INDOOR UNIT. Hydro box ERSC OUTDOOR UNIT

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3)

ECODAN ecodan can heat rooms and supply domestic hot water, realising greater comfort and energy saving.

Central Home Heating and Hot Water Supply

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Do you want a versatile solution

Samsung Eco Heating System

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Tower Green HE Hybrid

HEAT PUMPS LINE AS AIR TO WATER

THE HEAT PUMP CHOICE OF PROFESSIONALS

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

Sweden s leading air source heat pump

HT V2 HT Split

AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Air to water Heat Pump System

Samsung System Air Conditioner Eco Heating System

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Inverter Hot Water Heat Pumps

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Air to water Heat Pump System

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

2012 Heating Price List. Price List Heating 1st November Mitsubishi Electric is a market leader in renewable solutions.

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

NATURAL HEATING MACHINE

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Natural geothermal energy

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

FREQUENTLY ASKED QUESTIONS

TOSHIBA AIR CONDITIONING

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

FLOW TEMP. CONTROLLER [MASTER] (Cased) PAC-IF061B-E PAC-IF062B-E PAC-IF063B-E. FLOW TEMP. CONTROLLER [SLAVE] (Cased) PAC-SIF051B-E

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

HEAT PUMPS FOR HEATING AIR-TO-WATER

Product Line Introduction. Karl Zhang Technical support engineer

Technical description. Atec.

Efficient heating that won t cost the earth

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

Installer Please Read Instructions Inside

Mitsubishi Electric's

WHY A MHI HEAT PUMP?

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

QUANTUM. Reliable solar hot water, whenever you want it

High temperature air-to-water heat pumps

NIBE SPLIT ACVM 270 Air/water heat pump

PRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling

Advance Split

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Samsung Air Conditioning

PAC BT LOW TEMPERATURE HEAT PUMP

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator

White paper: New Ecodesign rules and energy labelling for space and water heaters

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Heat Pump Air Conditioning Systems

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Kills bills. How Vaillant technologies reduce home heating bills

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Air to Water Heat Pump

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

FLOW TEMP. CONTROLLER 3 (Cased) PAC-IF041B-E

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Increase your flexibility.

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

Product catalogue 2014 INNOVATIVE IDEAS FOR SMART SAVING

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

A +++ R32 Daikin Altherma 3 powered by Bluevolution. Why choose Daikin Altherma 3? 65 C

2009 Panasonic Marketing Europe GmbH / All rights reserved

Daikin Altherma Low Temperature monobloc heat pump

PRODUCT LINEUP AIR TO WATER For RESIDENTIAL

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

AIR CONDITIONING SYSTEMS

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

> > > Heat pump systems. Water Chillers. Dehumidifiers

User instructions DHP-AT

A single answer for multiple zones.

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

PROMATIC WDC Heating controllers Energy under control

Transcription:

145

ECODN ECODN can heat rooms and supply domestic hot water, realising greater comfort and energy saving. ECODN Economic, eco conscious next generation heating system Both energy-saving and safe for the environment, the Mitsubishi Electric ECODN incorporates a highly efficient heat pump system that captures the heat in the air, a renewable energy resource. Equipped with advanced inverter control, meticulous temperature control assures comfortable heating, and its space-saving ll-in-one indoor unit is easy to install. These energysaving, high comfort and simple installation characteristics have drawn the ECODN heating system into the spotlight centre stage. Excellent ECODN s heating performance, even at low outdoor temperature! INDOOR UNIT OUTDOOR UNIT Hydro box, cylinder unit Packaged type Small capacity (Under 5)* Medium capacity (7.514)* Large capacity ( )* > = HW112/140 W50 W85 W112 Split type Small capacity (Under 5)* Medium capacity (7.514)* Large capacity* Reversible hydro box, Reversible cylinder unit SHW80/112/140 SHW2 SW50 SW75 SW100/120 SW0/200 Eco Inverter SUHZ-SW45 FRP71 * Rated capacity is at conditions 2W35. (according to EN14511) 146

2015 811/2013 2015 811/2013 New eco-design directive What is the ErP Directive? The Ecodesign Directive for Energy-related Products (ErP Directive) established a framework to set mandatory standards for ErPs sold in the European Union (EU). The ErP Directive introduces new energy efficiency ratings across various product categories. It affects how products such as computers, vacuum cleaners, boilers and even windows are classified in terms of environmental performance. Labelling regulations that apply to our TW heat pumps come into effect as of September 26, 2015. New energy label and measurements Under directive 2009/125/EC, TW heat pumps of up to 70 are required to show their heating efficiency on the energy label. The purpose of the energy label is to inform customers about the energy efficiency of a heating unit. The efficiency for space heating is ranked from to G. In the case of domestic hot water, it is from to G. package label is also required if the ECODN heat pump is installed with a controller and/or a solar system or additional. ll ECODN units* are already rated as for heating at both 55 and 35 and for domestic hot water, which are the highest efficiency ranks. *Except for our T/TW hybrid system Mr. SLIM Product label This label is for individual heating units, such as an ECODN heat pump. Typically, the space label is used for ECODN systems with a hydro box, and the combination label is used for ECODN systems with a cylinder unit. Heat pump space label Manufacturer Outdoor and indoor unit model name Symbol for space heating efficiency in low-flow temperature operation efficiency in medium-flow temperature operation Indoor and outdoor unit operating sound power level values Rated heat output () under average, colder and warmer conditions Combination label Symbol for domestic hot water DHW efficiency during medium-temperature operation European temperature climate map These labels are delivered with all ECODN outdoor units. What is the package label? heating system can use several energy-related products, such as a controller or solar thermal system. Therefore, a label showing the efficiency of the total heating system is required. The category range is defined from to G. Creating the package label is the responsibility of the installers and distributors. useful tool on the Mitsubishi Electric website is available to easily create the labels for ECODN products and controllers. erp.mitsubishielectric.eu/erp/options Package label This label is for heating systems that use several energy-related products, such as a controller or a solar thermal system. Package space label Sample B C D E F G Sample-1 with solar thermal system with hot-water storage tank with temperature controller with auxiliary heating units Package combination label Sample L B C D E F G L B C D E F G Sample-2 Designed for Optimal ZUBDN New Generation (Split type) Reliable performance in low-temperature outdoor air Customised package labels including ECODN heat pumps and 5 controller can be created on the Mitsubishi Electric website. ZUBDN New Generation provides powerful heating in cold regions where most heat pumps cannot perform very well. Its rated heating capacity is maintained even in outdoor temperatures as low as 15, even when flow temperature needs to be higher. That means it can be trusted to provide comfortable heating during severe winter months. Benefits ZUBDN New Generation Example: SHW140YH Integrated capacity () W45 (according to EN 14511) pprox. 22% higher than our previous model! 15 14 13 12 11 10 9 Nominal capacity can be kept at -15ºC! Previous model ZUBDN New Generation -28-20 -15-7 0 Outdoor-air temperature at intake duct Mitsubishi Electric s Flash Injection Technology The key to high heating performance at low outdoor temperatures Flash Injection Circuit Heat interchanger (HIC) B Injection compressor Flash Injection Circuit ZUBDN New Generation Indoor HE Refrigerant flow Power receiver LEVB LEVC B Injection compressor (injection port) LEV Flash Injection Circuit Outdoor HE Heat interchanger (HIC) The Flash Injection Circuit is an original technology. heat exchange process at point (heat interchanger) transforms liquid refrigerant into a two-phase, gas-liquid state and then compresses the gas-liquid refrigerant at point B (injection compressor). This circuit secures a sufficient flow rate of refrigerant for heating when outdoor temperatures are very low. Thanks to improving the heat interchanger and introducing a new injection compressor, the Flash Injection Circuit is now more powerful. 147

Indoor units New all-in-one compact indoor unit Easy to install and low maintenance ll-in-one: Key functional components are incorporated Compact cylinder unit: Just 00mm in height Compact hydro box: Only 600600mm footprint Easy installation: Factory fitted pressure relief valve Easy service: Relevant parts are located at the front of the unit for easy maintenance Easy transport: Handles attached on front and back (cylinder unit) Hydro box (Split type) Water pump Plate heat exchanger Strainer Expansion vessel* Booster * Manometer Cylinder unit (Split type) Manometer Booster * Strainer Expansion vessel* Tank 3-way valve Domestic hot water pump Scale trap Larger capacity system Outdoor units SW0/200YK SHW2YK2 Water pump Plate heat exchanger djustable feet Indoor units EHSE-YM9EC, EHSE-, ERSE-YM9EC, ERSE- Domestic hot water plate heat exchanger *Depending on model Our 810HP ECODN heat pumps, only available with a hydro box connection, are suitable for large houses and small businesses where a high heating load is necessary. Our latest generation of 810HP Power Inverter outdoor units can now reach 60 maximum flow temperature instead of 53 previously. The new 810HP hydro box is available in both heating only and reversible and can be connected to a customised capacity domestic hot water tank. High-performance for domestic hot water re-charge External plate heat exchanger more energy savings using ECODN s unique and innovative technologies Save energy in domestic hot water operations Thanks to an external plate heat exchanger, ECODN offers much higher domestic hot water efficiency. Compared to our previous model, domestic hot water recharge efficiency is improved by approximately 17%* 1, thereby reducing operating costs. void performance loss due to scale scale trap is incorporated after the plate heat exchanger to capture calcium scale particles, thus maintaining the high performance of the external plate heat exchanger. (Just a 3% reduction during 15 years* 2 ). Lighter weight Compared to our previous model, the cylinder unit is up to 15kg lighter*. This is thanks to the coil incorporated in the tank which has been removed and replaced by a much lighter plate heat exchanger. *Comparison between and VM2B. Optimised stratification for better comfort COP (recharging) 140% Our new model (External heat exchanger with scale trap) 120% 100% 80% 60% 40% 20% 0% 0 2 4 6 8 10 12 14 year < * 1, * 2> Usage condition Thanks to the L-shaped inlet pipe from the plate heat exchanger, stratification is well maintained after re-charge. You do not need to worry about running out of hot water the same as with a conventional coil in tank. Supply water temperature can be kept high until all the hot water in the tank has been used. <Our test result> Initial performance level of previous model (Coil in tank) Tank temperature: 10 degree to 60 degree up time: 1 hour per 1 day Supersaturation of CaCO3: 50 *15 years accelerated testing The secret behind our external plate heat exchanger system Thanks to the unique plate heat exchanger and scale trap technology, a more efficient performance is achieved. In conventional systems, there is a risk of calcium scale building up on the heat-exchange plate if it is exposed to tap water directly. Therefore, it is difficult to use plate-based heat exchangers to heat tap water. To resolve this problem, ECODN is equipped with a scale trap that catches homogeneous calcium nuclei in the tap water before it has a chance to grow into large scales, thereby inhibiting build-up in the external heat exchanger. ECODN can use a plate heat exchanger to heat tap water, resulting in much higher domestic hot water performance. Notice: In the case of the special conditions such as very hard tap water, please consult with a specialist before installation. Circulating Water Tap Water Pump Scale Trap P-HE Hot Water Fresh Water External P-HE circuit DHW Storage Tank 148

Unique technology of ECODN uto daptation Maximize energy savings while retaining comfort at all times Regarding the relation of flow temperature and unit performance, a 1 drop in the flow temperature improves the coefficient of performance (COP) of the TW system by 2%. This means that energy savings are dramatically affected by controlling the flow temperature in the system. In a conventional system controller, the flow temperature is determined based on the pre-set heat curve depending on the actual outdoor temperature. However, this requires a complicated setting to achieve the optimal heat curve. Heat curve setting (Example) Flow temp. 60 If flow temperature is lowered 1 COP is improved 2% -15 10 Outdoor temp. Mitsubishi Electric s uto daptation function automatically tracks changes in the actual room temperature and outdoor temperature and adjusts the flow temperature accordingly. iming to realise further comfort and energy savings, Mitsubishi Electric is proud to introduce a revolutionary new controller. Our advanced uto daptation function measures the room temperature and outdoor temperature, and then calculates the required heating capacity for the room. Simply stated, the flow temperature is automatically controlled according to the required heating capacity, while optimal room temperature is maintained at all times, ensuring the appropriate heating capacity and preventing energy from being wasted. Furthermore, by estimating future changes in room temperature, the system works to prevent unnecessary increases and decreases in the flow temperature. ccordingly, uto daptation maximises both comfort and energy savings without the need for complicated settings. Future room temperature estimation Room temp. Target temp. (a) Higher than the target room temp. (b) pproximately same as the target temp. lower the flow temp. keep the flow temp. (c) Lower than the target room temp. raise the flow temp. Modify the flow temperature by comparing actual and estimated room temperature. 3 points T0 T1 Future Time Two-zone control (for heating/cooling) Simultaneously control two different zones Using ECODN, it is possible to control two different flow temperatures, thereby managing two different heating load requirements. The system can adjust and maintain two flow temperatures when different temperatures are required for different rooms; for example, controlling a flow temperature of 40 for the bedroom radiators and another flow temperature of for the living room floor heating. nother feature of this model is that two-zone cooling control is now possible. Using these functions it is easy to maintain the most comfortable temperature in each room and to save energy too. Two temperature zones Wireless remote controller as thermistor Hydro Box Pump 40 Mixing control Mixing valve Flow Switch Radiator Pump Mixing tank Flow Switch Underfloor heating *Items such as mixing tank, mixing valve flow switch and pumps are not included and need to be purchased locally. 149

Multiple unit control Connect up to 6 units utomatic control of multiple units for bigger capacity and better efficiency maximum of 6 units* can be configured according to the heating/cooling load of the building. The most efficient number of operating units is determined automatically based on heating/cooling load. This enables ECODN to provide optimal room temperature control, and thus superior comfort for room occupants. lso incorporated is a rotation function that enables each unit to run for an equal time period. If one of the units malfunctions when using the Multiple Unit Control, another unit can be automatically operated for back-up, thereby preventing the system operation from stopping completely. *Only same models (same capacity) can be used. Multiple unit control COP ratio (%) 100 1 unit 2 units 3 units 4 units 5 units 6 units Multiple unit control One large unit control lways high efficient operation! ON/OFF control Total Inefficient operation at low capacity. 23 23 23 23 23 23 Up to 138!! slave slave slave slave slave slave master Main RC Multiple unit control Intelligent boiler interlock n existing boiler can be used for extra heating capacity in an efficient way The flexibility of ECODN s intelligent control allows the system to be combined with the boiler currently in use. dditionally, this control can judge which heating source to use either ECODN or the existing boiler, based on various conditions*. In the event of one heating unit not working due to some unforeseen problem, the other heating system can be used as a back-up, thereby preventing the heating system operation from stopping completely. *Please check below Heat source switchover. Intelligent system combining a boiler with ECODN Intelligent boiler interlock systen Hydro box Room temperature wireless remote controller (option) Electricity *Thermostat (field supply) also can be used. Radiator Radiator Turning boiler on/off according to operational conditions. Pump Other source (Gas, Oil, etc) Mixing tank Boiler * Items such as a mixing tank, and pump are not included and need to be purchased locally. Heat source switchover - Choose appropriate system based on needs 4 types of heat source switchover logic 1 Switchover based on actual outdoor temperature Heat source switchover occurs when the outdoor temperature drops below a pre-set temperature. 2 Switchover based on running cost Heat source switchover occurs by judging optimal operation based on running cost. *Pre-registration of the energy price of electricity, and gas or oil per 1h is necessary. 3 4 Switchover based on CO2 emission level Heat source switchover occurs to minimise CO2 emission. *Pre-registration of CO2 emission amount from electricity and gas or oil is necessary. Switchover can also be activated via external input For example, the peak cut signal from electric power company. 150

Remote controllers Smart user-friendly controller with stylish design Main remote controller Large screen and backlight for excellent visibility, even in dark environment Multi-language support (supports 15 languages) Can be removed from main unit and installed in a remote location (up to 500m) Quick reading of operation data (7.5 times faster than previous model) Wide range of convenient functions in response to user demand Function settings NEW NEW NEW NEW Energy monitoring Two-zone control (cooling and heating) Two separate schedules Summer time setting Built-in room temperature sensors Hybrid control (boiler interlock) Wireless remote controller (optional) Floor drying mode Weekly timer Holiday mode Legionella prevention Error codes Built-in room temperature sensor; easy to place in the best position to detect room temperature Wiring work eliminated Simple design that is easy to operate Remote control from any room without needing to choose an installation location Backlight and big buttons that are easy to operate Domestic hot water boost and cancellation Simplified holiday mode 13 Jun 2015 13:41 Main controller PR-WT50R-E (Option) Wireless remote controller PR-WR51R-E (Option) Receiver Energy monitoring View electricity consumption and heat output on the remote controller Every end user can now easily check the energy data of the ECODN heat pump. Other features Daily, monthly and yearly data are stored and can be displayed using the main remote controller. External power meter and heat meter can be connected for accurate measurement. SD card is also available for storing data. capacity produced Electric energy used 2 Jan 2015 23:59 CONSUMED ELECTRICL ENERGY Jan 2015 57 DHW 7 Heatin 50 Coolin 0 *Using pre-set values on the main remote controller, estimated energy consumption/output can be shown without external power and a heat meter. Depending on operating condition and system configuration, there is some possibility to show different data from the reality. *This function is available depending on the version of the outdoor unit model. Summer time setting Easy adjustment for summer time Two separate schedules Pre-setting two different schedules for winter and summer seasons Just switch the summer time mode on using the main remote controller and the clock in the main remote controller is adjusted to summer time hours. This function can release the end user from clock setting tasks. Two different schedule settings are available for use via the main remote controller. These schedules can be pre-set and changed depending on the season. For example, from November to March, space heating and domestic hot water are used; however, during warm months such as from pril to October, only domestic hot water is used. <Example> 29 2015 23:59 6h 15h Summer time 2015 0:00 7 1 Sep 2015 12: Schedule 1 Schedule timer 1 pr Oct Schedule timer 2 Nov Mar Jan Dec Space heating Domestic hot water Winter time daytime early morning Schedule 2 Domestic hot water Summer time any time 151

Easy commissioning Pump for primary water circuit* speed setting possible using ECODN s main remote controller Even when the system is running, pump output can be set to one of five different settings using the main remote controller. The person commissioning the system can adjust this speed much more easily. *Speed setting of pump for domestic hot water is not available through the main remote controller when the system is running. Flow sensor newly incorporated The flow sensor is key for monitoring energy output and can also be used to detect flow error as well. Flow rate can be checked on the main remote controller. Flow rate can also be shown as graphs using the SD card tool. Run indoor unit* without outdoor unit During installation or situations such as an outdoor unit malfunction, the indoor unit can be operated using a. While using this mode, flow and tank temperature are selectable. Fixing and maintenance of the outdoor unit can be done without stopping heating and domestic hot water operation*. *Models with electric only. *When the indoor unit operation stops, please check all settings after the outdoor unit is connected. SD* card For easier settings and data logging The initial setting for ECODN is now simpler than ever before. The special software enables the required initial settings to be saved to an SD card using a personal computer. The system set-up is as easy as moving the SD card from the computer to the SD card slot in the indoor unit. Compared to the previous procedure of inputting settings using the main controller at the installation site, a remarkable reduction in set-up time has been achieved. Thus, it is ideal for busy installers. Hydro box operation panel Printed circuit board Control and electric box SD card slot SD card SD card performed easily and the logging of operation data saved to an SD card can be confirmed via a personal computer. *SD card function is only used at the time of installation. Items that can be pre-set Simply copying pre-set data to an SD card, the same settings can input into another unit using the SD card. Initial settings (time display, contact number, etc.) settings uto adaptation Heat curve Two different temperature zones (heating and cooling) Interlocked boiler operation settings Holiday mode settings Schedule timer settings (two separate schedules) Domestic hot water settings Legionella prevention settings ll items that are set by the main controller can be set via a personal computer. Data that can be stored Operation data up to a month long can be stored on a single SD card (2GB). Consumed electrical energy Delivered energy Flow rate Operation time Defrost time ctual temperature Room temperature Return temperature Domestic hot water temperature Outdoor temperature Error record Input signal Etc. 152

Split type specifications Indoor unit <Cylinder unit> Dimensions Weight (empty) HWD mm kg Power supply (V/ Phase / Hz) Heater Booster Power supply (V/ Phase / Hz) Immersion Power supply (V/ Phase / Hz) Domestic hot water tank Guaranteed operating range*1 Target temperature range Volume / Material mbient Outdoor Sound pressure level (SPL) Type Immersion Expansion vessel Booster Room temperature Room temperature DHW Legionella prevention L / *1 The environment must be frost-free *2 UK model db () 200 / Stainless steel 0~35*1 See outdoor unit spec table 10~ 25~60 40~60 60~70 28 EHST20D- EHST20D- EHST20D- EHST20D- EHST20D- VM6C YM9C TM9C VM2EC VM6EC YM9EC YM9C VM2EC MHC MHCW*2 only 00595680 110 111 112 112 104 105 106 103 103 105 97 103 96 110 103 400/Three/50 2/Three/50 400/Three/50 400/Three/50 2 6 (2/4/6) 9 (3/6/9) 9 (3/6/9) 2 6 (2/4/6) 9 (3/6/9) 2 9 (3/6/9) 2 9 26 13 23 9 26 13 9 13 9 32 32 32 3 3 13 13 EHST20D- MHCW*2 <Hydro box> Dimensions Weight (empty) Type Immersion Expansion vessel Booster HWD mm kg Power supply (V/ Phase / Hz) Heater Booster Power supply (V/ Phase / Hz) Guaranteed mbient operating range*1 Target temperature range Outdoor Room temperature Room temperature Sound pressure level (SPL) db () *1 The environment must be frost-free EHSD- EHSD- MC EHSD- EHSD- YM9C VM2EC VM6C VM6EC YM9C YM9EC TM9C EHSE- YM9EC only 8005360 950600360 38 43 44 45 42 48 43 49 44 49 44 49 60 62 400/Three/50 400/Three/50 2/Three/50 400/Three/50 2 9 (3/6/9) 2 2 6 (2/4/6) 6 (2/4/6) 9 (3/6/9) 9 (3/6/9) 9 (3/6/9) 9 (3/6/9) 9 13 9 9 26 26 13 13 23 13 32 32 32 0~35*1 See outdoor unit spec table 10~ 25~60 28 EHSE- <Reversible cylinder unit> Dimensions Weight (empty) HWD mm kg Power supply (V/ Phase / Hz) Heater Booster Power supply (V/ Phase / Hz) Immersion Power supply (V/ Phase / Hz) Domestic hot water tank Guaranteed operating range*1 Target temperature range Volume / Material mbient Outdoor Sound pressure level (SPL) Type Immersion Expansion vessel Booster Room temperature Room temperature DHW Legionella prevention L / *1 The environment must be frost-free *2 If you use our system in cooling mode at the low ambient temperature (10 or below), there are some risks of plate heat exchanger breaking by frozen water. db () ERST20D- ERST20D- ERST20C- and cooling 00595680 103 96 110 2 2 9 9 200 / Stainless steel ERST20C- 103 0~35*1 See outdoor unit spec table See outdoor unit spec table (minimum 10*2) 10~ 25~60 5~25 40~60 60~70 28 <Reversible hydro box> Type Immersion Expansion vessel Booster Dimensions Weight (empty) HWD mm kg Power supply (V/ Phase / Hz) Heater Booster Power supply (V/ Phase / Hz) Guaranteed mbient operating range*1 Outdoor Target temperature range Room temperature Room temperature ERSD- ERSC- ERSC- ERSE- ERSE- YM9EC and cooling 8005360 950600360 45 43 49 61 63 400/Three/50 2 2 9 (3/6/9) 9 9 13 0~35*1 See outdoor unit spec table See outdoor unit spec table (minimum 10*2) 10~ 25~60 5~25 Sound pressure level (SPL) db () 28 *1 The environment must be frost-free *2 If you use our system in cooling mode at the low ambient temperature (10 or below), there are some risks of plate heat exchanger breaking by frozen water. 153

Outdoor unit SUHZ- SW45V (H) *1 SW50VK (-BS) SW75VH (-BS) SW100V/YH (-BS) SW120V/YH (-BS) SW0YK (-BS) SW200YK (-BS) SHW80VH SHW112V/YH SHW140YH SHW2YK2 Dimensions HWD mm 8808403 68090 9439503 13509503 13509503 133810503 133810503 13509503 13509503 13509503 133810503 Product weight (empty) kg 54 43 75 118/1 118/1 136 136 120 120/134 134 149 Power supply (V / Phase / Hz) VH : YH, YK : 400/Three/50 (7/W35) (2/W35) (35/W7) (35/W18) Sound pressure level (SPL) Sound power level (PWL) COP Power input COP Power input EER Power input EER Power input db () db () 4.50 5.06 0.889 3.50 3.40/3.04 1.029/1.151 4.00 2.73 1.465 3.80 4.28 0.888 52 61 5.50 4.42 1.244 5.00 2.97 1.684 4.50 2.76 1.6 5.00 4.60 1.087 46 63 8.00 4.40 1.818 7.50 3.40 2.206 6.60 2.82 2.340 7.10 4.43 1.603 51 68 11.20 4.45 2.517 10.00 3.32 3.009 9.10 2.75 3.9 10.00 4.35 2.299 54 70.00 4.10 3.902 12.00 3.24 3.704 12.50 2.32 5.388 14.00 4.08 3.431 54 72 22.00 4.20 5.238.00 3.11 5.145.00 2.76 5.797 18.00 4.56 3.947 62 78 25.00 4.00 6.250 20.00 2.80 7.143 20.00 2.25 8.889 22.00 4.10 5.366 62 78 8.00 4.65 1.720 8.00 3.55 2.254 7.10 3.31 2.145 7.10 4.52 1.571 51 69 11.20 4.46 2.511 11.20 3.34 3.353 10.00 2.83 3.534 10.00 4.74 2.110 52 70 14.00 4.22 3.318 14.00 2.96 4.7 12.50 2.17 5.760 12.50 4.26 2.934 52 70 23.00 3.65 6.1 23.00 2.37 9.705 20.00 2.22 9.009 20.00 3.55 5.634 59 75 Operating current (max) 12.0 20 13.0 17.0 25 29.5/13.0 32/ 29.5/13.0 32/ 19.0 25 21.0 32 29.5 32 35.0/13.0 40/ 13.0 26.0 32 Piping Guaranteed operating range Diameter Liquid/Gas Max. length Out-In Max. height Out-In DHW *2 mm m m 6.35/12.7 15 to 24 15 to 35 10 to 46 6.35/12.7 40 15 to 21 15 to 35 15 to 46 9.52/15.88 40 20 to 21 20 to 35 15 to 46 9.52/15.88 75 20 to 21 20 to 35 15 to 46 9.52/15.88 75 20 to 21 20 to 35 15 to 46 9.52/25.4 80 20 to 21 20 to 35 15 to 46 12.7/25.4 80 20 to 21 20 to 35 15 to 46 9.52/15.88 75 28 to 21 28 to 35 15 to 46 9.52/15.88 75 28 to 21 28 to 35 15 to 46 9.52/15.88 75 28 to 21 28 to 35 15 to 46 12.7/25.4 80 25 to 21 25 to 35 15 to 46 Note: based on EN 14511 (Input to circulation pump is not included.) It may differ according to the system configuration. *1 SUHZ-SW45VH incorporates base. *2 Optional air protection guide is required where ambient temperature is lower than 5. Optional parts <Indoor unit> Parts name Specification Cylinder unit Hydro box Wirelss remote controller Wirelss receiver Thermistors Immersion EHPT accessories for UK Joint pipe Wi-Fi interface Drain pan stand PR-WT50R-E PR-WR51R-E PC-SE41TS-E For room temp. For buffer and zone PC-TH011-E (flow and return temp.) PC-TH011TK-E For tank temp. (5m) PC-TH011TKL-E For tank temp. (m) For boiler PC-TH011HT-E (flow and return temp.) PC-I03V2-E 1Ph 3 PC-WK01UK-E PC-SG73RJ-E PC-WF010-E PC-DP01-E For SW200YK/ SHW2YK2 (-BS) ø9.52 ø12.7 D665mm H270mm W595mm N/W: 14.5kg VM6C YM9C TM9C *1 PC-DP01-E is necessary when you use ERST units. If you use ERST units without this parts, drain will be flowed from the base of units, in cooling mode. VM2EC VM6EC YM9EC EHST20D- EHST20D- YM9C EHST20D- VM2EC EHST20D- EHST20D- MHC MHCW EHST20D- MHCW ERST models *1 E SD or E SC models E SE models <Outdoor unit> Parts name Connector for drain hose signal output ir discharge guide ir protection guide Drain socket Centralised drain pan Control/Service tool PC-SE60R-E PC-SE61R-E MC-886SG-E PC-SJ07SG-E PC-SG59SG-E PC-SH96SG-E PC-SJ06G-E PC-SH63G-E PC-SH95G-E PC-SG61DS-E PC-SJ08DS-E PC-SG63DP-E PC-SG64DP-E PC-SH97DP-E PC-SK52ST Eco Inverter SUHZ- SW45V (H) SW50VK (-BS) SW75VH (-BS) Power Inverter SW100V/YH (-BS) SW120V/YH (-BS) SW0YK (-BS) SW200YK (-BS) SHW80VH ZUBDN SHW112V/YH SHW140YH SHW2YK2 154

Packaged type specifications Indoor unit <Cylinder unit> Dimensions Weight (empty) Power supply (V/ Phase / Hz) HWD mm kg Heater Booster Power supply (V/ Phase / Hz) Immersion Power supply (V/ Phase / Hz) Domestic hot water tank Guaranteed operating range*1 Target temperature range Volume / Material mbient Outdoor Type Immersion Expansion vessel Booster Room temperature DHW Legionella prevention L / Sound pressure level (SPL) db () *1 The environment must be frost-free *2 UK model EHPT20- EHPT20-VM6C EHPT20-YM9C only EHPT20-TM9C EHPT20-MHCW*2 00595680 98 99 100 100 98 400/Three/50 2/Three/50 2 9 6 (2/4/6) 26 32 9 (3/6/9) 13 9 (3/6/9) 23 32 3 13 200 / Stainless steel 0~35*1 See outdoor spec table 10~ 25~60 40~60 60~70 28 <Hydro box> Type Immersion Expansion vessel Booster Dimensions HWD mm Weight (empty) kg Power supply (V/ Phase / Hz) Heater Booster Power supply (V/ Phase / Hz) Guaranteed mbient operating range*1 Outdoor Target temperature Room temperature range Sound pressure level (SPL) db () *1 The environment must be frost-free EHP- EHP-VM6C EHP-YM9C only 37 8005360 38 38 400/Three/50 2 9 6 (2/4/6) 26 9 (3/6/9) 13 32 0~35*1 See outdoor spec table 10~ 25~60 28 Outdoor unit Dimensions HWD mm Product weight (empty) kg Power supply (V / Phase / Hz) (7/W35) COP Power input (2/W35) COP Power input Sound pressure level (SPL) db () Sound power level (PWL) db () W50VH2 (-BS) 7409503 64 5.00 4.50 1.111 5.00 3.50 1.429 46 61 W85VH2 (-BS) 9439503 79 9.00 4.18 2.153 8.50 3.17 2.681 Operating current (max) 13.0 23.0 25 29.5 32 13.0 Guaranteed operating range DHW 15 to 21 15 to 35 20 to 21 20 to 35 20 to 21 20 to 35 25 to 21 25 to 35 *1 15 to 46 15 to 46 15 to 46 15 to 46 Note: based on EN 14511 (Input to circulation pump is included.) It may differ according to the system configuration. *1 Optional air protection guide is required where ambient temperature is lower than 5. 48 66 W112VH (-BS) HW112YH2 (-BS) HW140VH2 (-BS) HW140YH2 (-BS) 135010203 133 11.20 4.47 2.506 11.20 3.34 3.353 135010203 148 400/Three/50 11.20 4.42 2.534 11.20 3.11 3.601 135010203 134 14.00 4.25 3.294 14.00 3.11 4.502 135010203 148 400/Three/50 14.00 4.25 3.294 14.00 3.11 4.502 53 69 53 67 53 67 35.0 40 25 to 21 25 to 35 15 to 46 53 67 13.0 25 to 21 25 to 35 15 to 46 155

Optional parts <Indoor unit> Parts name Specification Cylinder unit Hydro box EHPT20- EHPT20-VM6C EHPT20-YM9C EHPT20-TM9C EHPT20-MHCW EHP- EHP-VM6C Wireless remote controller Wireless receiver Thermistors Immersion EHPT accessories for UK Wi-Fi interface PR-WT50R-E PR-WR51R-E PC-SE41TS-E PC-TH011-E PC-TH011TK-E PC-TH011TKL-E PC-TH011HT-E PC-I03V2-E PC-WK01UK-E PC-WF010-E For room temp. For buffer and zone (flow and return temp.) For tank temp. For tank temp. (longer) For boiler (flow and return temp.) 1Ph 3 EHP-YM9C <Outdoor unit> Parts name Power Inverter ZUBDN Connector for drain hose signal output PC-SE60R-E ir discharge guide PC-SG59SG-E ir protection guide PC-SH63G-E Drain socket PC-SG61DS-E Centralised drain pan PC-SG64DP-E Control/Service tool PC-SK52ST W50VH2(-BS) W85VH2(-BS) W112VH (-BS) HW112YH2(-BS) HW140VH2(-BS) HW140YH2(-BS) Interface/ controller Parts name Description step control interface PC-IF011B-E controllers PC-IF032B-E System controllers PC-IF061B-E PC-IF062B-E PC-SIF051B-E Note: SUHZ CNNOT be connected to these IFs. 1 PC Board w/ Case 1 PC Board w/ Case 1 PC Board w/ Case 1 PC Board w/ Case 1 PC Board w/ Case 156

157 Combination table Split type Type VM6C YM9C TM9C VM2EC VM6EC YM9EC MHCW EHST20D- EHST20D- EHST20D-MHC EHST20D-MHCW EHST20D-VM2EC EHST20D-YM9C ERST20C- ERST20C- ERST20D- ERST20D- EHPT20- EHPT20-VM6C EHPT20-YM9C EHPT20-TM9C EHPT20-MHCW VM2EC VM6C VM6EC YM9C YM9EC TM9C EHSD- EHSD-YM9C EHSD- EHSD-MC ERSC- ERSC- ERSD- EHP- EHP-VM6C EHP-YM9C EHSE-YM9EC EHSE- ERSE-YM9EC ERSE- Eco Inverter SUHZ- SW45V(H) Power Inverter SW75VH SW50VK Cylinder unit Hydro box Package type HW112YH2 ZUBDN HW140VH2 HW140YH2 W112VH Power Inverter W85VH2 W50VH2

158 Split type : Combination is available. Blank: Combination is NOT available. SW100VH SW100YH Power Inverter SW120VH SW120YH SW0YK SW200YK SHW2YK2 SHW80VH SHW112VH ZUBDN SHW112YH SHW140YH Mr. SLIM FRP71VH