WORLDWIDE DISTRIBUTORS Australia Austria Bahrain Belgium Brazil Bulgaria Canada Chile Cyprus Denmark Estonia Finland France Germany Hungary Iceland Italy Kazakhstan Kuwait Latvia Lithuania Malta Oman Poland Portugal Qatar Rep.of Ireland Romania Russia Slovenia Spain The Netherlands Turkey UAE UK Certificate No FM 85224 All Thermoscreens products are certified in accordance with CE regulations and where applicable comply with the following standards: EN 60335-2-30, 89/336/EEC Electromagnetic Compatibility (EMC), Machinery Directive (89/392/EEC, as amended by 91/368/EEC, 93/44/EEC and 93/68/EEC) Low Voltage Directive, (72/23/EEC as amended by 93/68/EEC) IP21 Rating CSA - Standard 22.2 UL 2021 / UL 1995, GOST R 23511-79, GOST R 50033-92 Thermoscreens Limited, St. Mary's Road, Nuneaton, Warwickshire CV11 5AU Telephone: +44 (0) 2476 384 646 Fax: +44 (0) 2476 388 578 E-mail: sales@thermoscreens.com Web site: www.thermoscreens.com All information within this brochure is for reference purposes only. Products are manufactured under a continuous improvement process and details may change. A GROUP COMPANY Registered in England no. 691333
Heat Pump Range in cooperation with AIR CONDITIONING SYSTEMS
HEAT PUMP RANGE The PHV DXE range of air curtains has been developed in a collaboration between Thermoscreens, the market leading manufacturer of high quality air solutions and the leading environmental control manufacturer Mitsubishi Electric. Heat pumps are movers of heat energy and upgrade naturally occurring low temperature heat from the surrounding outdoor air into useful high temperature heat which can then be used to reduce the primary fuel consumption of mechanical equipment. As heat pumps require less that a third of the power of an equivalent direct electric air curtain, they are considerably cheaper to run. heat pump. The air curtain and heat pump is controlled via a Mitsubishi interface integrated in the air curtain. This allows a high degree of efficiency and high COP s up to 3.7. Both Thermoscreens and Mitsubishi Electric are responding to a growing market for highly efficient equipment that delivers exceptional performance in the most energy efficient way possible. The retro fit of a heat pump is easy and not expensive. The heat pump unit is usually installed on the top of a building or on the facade. The air curtain is installed above the door opening as usual and connected to the ENERGY RECOVERY AND TECHNOLOGY Heat pumps upgrade naturally occurring energy from the outdoor air via a refrigerant gas (R410A) and transmit this energy to an air curtain. Outdoor air energy Electric energy for heat pump Heating energy for air curtain Heat pump
HEAT PUMP RANGE APPLICATION The range is available as either surface mounted or recessed models. The recommended maximum door height of an installation is 3.75m. AIR CURTAIN The surface mounted PHV DXE range is manufactured in a contemporary design. The steel casing, including the removable front panel, is finished in standard RAL 9010. The recessed unit is designed with a combined inlet and outlet grille. Tangential fans provide a constant and comfortable air stream. EFFICIENCY The independent BRE Institute ( Building Research Establishment,UK) analysed the efficiency of the whole system. A COP of 3.7 was achieved. This can vary between 2.4 and 3.7 depending on the outdoor temperature and operating performance. HEAT PUMP The air curtain PHV DXE is equipped with a Mitsubishi Electric interface. This allows an easy connection to Mr. Slim Power Inverter and Zubadan Inverter heat pumps. The systems are aligned and allow optimal functioning. BENEFITS Advanced modern technology Reduced running costs Reduced carbon emissions Significant payback period Easy to install and maintain High energy efficiency through inverter technology Allows open door policy
PHV DXE SURFACE MOUNTED 3,75 PHV1500DXE NT PHV2000DXE NT 0 0,5 1,0 1,5 2,0 Technical specification Model PHV DXE Models Dimensions L x D x H (mm) Supply (50Hz) Heat Output (kw) COP Loading (A) Velocity (m/s) Air volume (m 3 /h) Weight (kg) db(a) @ 3m PHV1500DXE NT HO 1746 x 377 x 255 400V-3P&N PHV2000DXE NT LO 2296 x 377 x 255 400V-3P&N PHV2000DXE NT HO 2296 x 377 x 255 400V-3P&N 50% 8.3 100% 14.4 50% 7.9 100% 14.1 50% 11.2 100% 21.3 3.7 2.5 3.7 2.9 3.2 2.4 12.7 1 9.0 2600 60 60 15.7 2 9.5 3300 78 61 15.7 2 9.0 3130 80 61 1 for units with electric heaters disabled, 240v power supply 1.8 amp load 2 for units with electric heaters disabled, 240v power supply 2.7 amp load PHV DXE RECESSED RANGE 3,50 PHV1500DXE R PHV2000DXE R 0 0,5 1,0 1,5 2,0 Technical specification Model PHV DXE R Models Dimensions L x D x H (mm) Supply (50Hz) Heat Output (kw) COP Loading (A) Velocity (m/s) Air Volume (m 3 /h) Weight (kg) db(a) @ 3m PHV1500DXE R HO 1650 x 436 x 296 400V-3P&N PHV2000DXE R LO 2240 x 436 x 296 400V-3P&N PHV2000DXE R HO 2240 x 436 x 296 400V-3P&N 50% 8.3 100% 14.4 50% 7.9 100% 14.1 50% 11.2 100% 21.3 3.7 2.5 3.7 2.9 3.2 2.4 12.7 1 9.0 2600 67 60 15.7 2 9.5 3300 85 61 15.7 2 9.0 3130 88 61 1 for units with electric heaters disabled, 240v power supply 1.8 amp load 2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
PHV DXE SURFACE MOUNTED 100 250 mm min. for pipes E D E 295 255 377 C A B C Electric Supply and Control Wiring Inlets PHV1500DXE NT PHV2000DXE NT A (mm) 1746 2296 B (mm) 1400 1896 C (mm) 700 948 D (mm) 1300 1824 E (mm) 650 912 168 36 M10 inserts x 6 mm Hot Gas Refrigerant Connection Liquid Line Refrigerant Connection PHV DXE RECESSED RANGE 436 Alternative position for Electrical Supply an Control Wiring Inlets 100 296 DECKENNIVEAU CEILING LEVEL 20-65mm 476 C Electric Supply and Control Wiring Inlets B A B PHV1500DXE R PHV2000DXE R A (mm) 1650 2240 B (mm) 800 1095 C (mm) 1690 2290 Cut-Out in Ceiling: Length (mm) 1655 2245 Width (mm) 445 445 55 314 140 M10 inserts x 6 mm Hot Gas Refrigerant Connection Liquid Line Refrigerant Connection www.thermoscreens.com
HEAT PUMP MR.SLIM, POWER-/ZUBADAN- INVERTER Technical Data- PUHZ range Models Dimensions LxWxH (mm) Supply (50hz) Loading A per phase Fuse Complete pipe length max. height Connections difference Communication cable Thermoscreens Mitsubishi Electric PHV1500DXE HO PUHZ-RP140YHA (Power Inverter) PUHZ-HRP125YHA (Zubadan Inverter) 950 x 330 x 1350 400V-3PN 6.37 16 75 30 943 x 330 x 1350 400V-3PN 4.91 16 75 30 s. 16 s. 16 PHV2000DXE LO PUHZ-RP140YHA (Power Inverter) PUHZ-HRP125YHA (Zubadan Inverter) 950 x 330 x 1350 400V-3PN 6.37 16 75 30 943 x 330 x 1350 400V-3PN 4.91 16 75 30 s. 16 s. 16 PHV2000DXE HO PUHZ-RP200YHA2 (Power Inverter) 950 x 330 + 30 x 1350 400V-3PN 8.8 32 120 30 s. 22 CONTROL SYSTEM Mitsubishi Electric Mr. Slim Kommunikationsleitung Connection cable Air Luftschleier curtain On/Off An/Aus Heating Heizung On/Off An/Aus Heating Heizung Auto/Low/High Auto/Niedrig/Hoch Thermoscreens PHV DXE Thermoscreens Control Bedieneinheit Unit
CONTROL OPTIONS MANUAL CONTROL The Thermoscreens air curtain have the option of a stand alone remote controller when the air curtain is not controlled by BEMS ( Building Energy Management System ). This controller has the following functions - 50% or 100% DIRTY FILTER INDICATOR Thermoscreens install a Dirty filter Indicator in every heat pump air curtain to indicate when the filter needs cleaning. The filter indicator schedule is based on fan operating hours and helps the customer to maintain and service the air curtain appropriately. - Ambient/heat switch - Auto Mode ( to ensure consistent comfort levels are thermostatically maintained) ADDITIONAL OPTIONS Standard colour RAL 9010, other RAL colours available on request Additional electrical heating for defrost period