WORLDWIDE DISTRIBUTORS

Similar documents
The advantages of closed heating systems. White paper

BFD Light Curtains The new choice for cutting edge safety for industrial doors

PTG, SWT Series. Heat Recovery Systems

International Product Compliance and Certifications. Product Safety Consulting, Inc.

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

Advantages of automatic boiler bottom blowdown

Textile fire protection closures EI 30/90

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications


This document is a preview generated by EVS

it500 Internet Thermostat INSTALLER MANUAL

English version. Alarm systems Terms and definitions

Future development of the furniture industry A look at the next 3-5 years

Installation Instructions

This document is a preview generated by EVS

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

Beckhoff short profile

Air and dirt in closed systems

This document is a preview generated by EVS

Forum for European Electrical Domestic Safety FEEDS. B. DOME FISUEL

CRA24-B3 controlled residential ventilation

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014

Expansion vessel in a solar installation. White paper

Type Approvals GARAGE DOOR OPENER RADIO TRANSCEIVER. (EuroHomeLink 2000) Czech Republic CTU R 1194 Cyprus MCW129/95 12/2000 Denmark 98.

ISO INTERNATIONAL STANDARD. Footwear Test methods for accessories: Touch and close fasteners Peel strength before and after repeated closing

ISO INTERNATIONAL STANDARD. Glass containers Vacuum lug finishes Part 1: General

HP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with Mr Slim Outdoor Units

International standards used locally worldwide ISO/TC 67

English Version. Office furniture - Office work chair - Part 4: Clarifications to EN :2000 (Dimensions)

Sýnishorn Safety of woodworking machines - One side thickness planing machines

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Part 1: Determination of film properties

Certificate of constancy of performance,

ISO 7458 INTERNATIONAL STANDARD. Glass containers Internal pressure resistance Test methods

ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) IRISH STANDARD I.S. EN 62382:2007. Price Code

The national standards bodies of:

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Steel cord conveyor belts Part 4: Vulcanized belt joints

This document is a preview generated by EVS

ILNAS-EN ISO 23640:2015

Sýnishorn Maintenance - Qualification of maintenance personnel

This document is a preview generated by EVS

CLEAR LIQUIDS - ESTIMATION OF COLOUR BY THE GARDNER COLOUR SCALE - PART 1: VISUAL METHOD (ISO :2004) IRISH STANDARD I.S. EN ISO :2005

This document is a preview generated by EVS

SOUTH AFRICAN NATIONAL STANDARD

ALARM SYSTEMS - INTRUSION AND

EUROPE STARTS WITH YOU!

ErP 2009/125/CE. Directives Eco design Energy labelling

LABORATORY GLASSWARE - GRADUATED MEASURING CYLINDERS (ISO 4788:2005) IRISH STANDARD I.S. EN ISO 4788:2005. Price Code

Sýnishorn ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 3: Standard penetration test

List of nationally authorised medicinal products

ISO/TS TECHNICAL SPECIFICATION. Geotechnical investigation and testing Laboratory testing of soil Part 6: Fall cone test

BIOLOGICAL EVALUATION OF MEDICAL

English Version. This Technical Report was approved by CEN on 11 December It has been drawn up by the Technical Committee CEN/TC 135.

DECORATIVE WALLCOVERINGS - ROLL AND PANEL FORM PRODUCTS IRISH STANDARD I.S. EN 15102:2007. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann

This document is a preview generated by EVS

This document is a preview generated by EVS

Rotary Screw Compressors SXC»Compact«Series

REFRIGERATING SYSTEMS AND HEAT

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

Recessed. Air Curtain. Fig 1. Recessed air curtain

Application guide RDG160 Remote control

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Flex resistance

This document is a preview generated by EVS

HEXALOBULAR INTERNAL DRIVING FEATURE FOR BOLTS AND SCREWS (ISO 10664:2005) IRISH STANDARD I.S. EN ISO 10664:2005. Price Code

Sýnishorn Respiratory protective devices - Gas filter(s) and combined filter(s) - Requirements, testing, marking

National foreword. Text affected

This document is a preview generated by EVS

International Customer Edition Date: June 2014

SOUTH AFRICAN NATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Glass containers Vacuum lug finishes Part 12: 89 regular

This document is a preview generated by EVS


This document is a preview generated by EVS

AIR CURTAIN T SURFACE MOUNTED RANGE

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015

Founding - Magnetic particle testing

ÍST EN :2015. Gildistaka ICS: 53.06

AutoM Click to go to the page. AutoM Auto Shaker Filter

SANS 21-1:2009 Edition 1 EN 115-1:2008

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

Sýnishorn Windows and doors - Watertightness - Test method

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

ISO INTERNATIONAL STANDARD

CONFORMITY ASSESSMENT - SUPPLIER'S

ICS Supersedes CLC/TS 62046:2005. English version

Eurocode 9 Design of aluminium structures


Sýnishorn Fire resistance test for service installations - Part 1: Ventilation ducts

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Operation Manual Part-No

SOUTH AFRICAN NATIONAL STANDARD

Transcription:

WORLDWIDE DISTRIBUTORS Australia Austria Bahrain Belgium Brazil Bulgaria Canada Chile Cyprus Denmark Estonia Finland France Germany Hungary Iceland Italy Kazakhstan Kuwait Latvia Lithuania Malta Oman Poland Portugal Qatar Rep.of Ireland Romania Russia Slovenia Spain The Netherlands Turkey UAE UK Certificate No FM 85224 All Thermoscreens products are certified in accordance with CE regulations and where applicable comply with the following standards: EN 60335-2-30, 89/336/EEC Electromagnetic Compatibility (EMC), Machinery Directive (89/392/EEC, as amended by 91/368/EEC, 93/44/EEC and 93/68/EEC) Low Voltage Directive, (72/23/EEC as amended by 93/68/EEC) IP21 Rating CSA - Standard 22.2 UL 2021 / UL 1995, GOST R 23511-79, GOST R 50033-92 Thermoscreens Limited, St. Mary's Road, Nuneaton, Warwickshire CV11 5AU Telephone: +44 (0) 2476 384 646 Fax: +44 (0) 2476 388 578 E-mail: sales@thermoscreens.com Web site: www.thermoscreens.com All information within this brochure is for reference purposes only. Products are manufactured under a continuous improvement process and details may change. A GROUP COMPANY Registered in England no. 691333

Heat Pump Range in cooperation with AIR CONDITIONING SYSTEMS

HEAT PUMP RANGE The PHV DXE range of air curtains has been developed in a collaboration between Thermoscreens, the market leading manufacturer of high quality air solutions and the leading environmental control manufacturer Mitsubishi Electric. Heat pumps are movers of heat energy and upgrade naturally occurring low temperature heat from the surrounding outdoor air into useful high temperature heat which can then be used to reduce the primary fuel consumption of mechanical equipment. As heat pumps require less that a third of the power of an equivalent direct electric air curtain, they are considerably cheaper to run. heat pump. The air curtain and heat pump is controlled via a Mitsubishi interface integrated in the air curtain. This allows a high degree of efficiency and high COP s up to 3.7. Both Thermoscreens and Mitsubishi Electric are responding to a growing market for highly efficient equipment that delivers exceptional performance in the most energy efficient way possible. The retro fit of a heat pump is easy and not expensive. The heat pump unit is usually installed on the top of a building or on the facade. The air curtain is installed above the door opening as usual and connected to the ENERGY RECOVERY AND TECHNOLOGY Heat pumps upgrade naturally occurring energy from the outdoor air via a refrigerant gas (R410A) and transmit this energy to an air curtain. Outdoor air energy Electric energy for heat pump Heating energy for air curtain Heat pump

HEAT PUMP RANGE APPLICATION The range is available as either surface mounted or recessed models. The recommended maximum door height of an installation is 3.75m. AIR CURTAIN The surface mounted PHV DXE range is manufactured in a contemporary design. The steel casing, including the removable front panel, is finished in standard RAL 9010. The recessed unit is designed with a combined inlet and outlet grille. Tangential fans provide a constant and comfortable air stream. EFFICIENCY The independent BRE Institute ( Building Research Establishment,UK) analysed the efficiency of the whole system. A COP of 3.7 was achieved. This can vary between 2.4 and 3.7 depending on the outdoor temperature and operating performance. HEAT PUMP The air curtain PHV DXE is equipped with a Mitsubishi Electric interface. This allows an easy connection to Mr. Slim Power Inverter and Zubadan Inverter heat pumps. The systems are aligned and allow optimal functioning. BENEFITS Advanced modern technology Reduced running costs Reduced carbon emissions Significant payback period Easy to install and maintain High energy efficiency through inverter technology Allows open door policy

PHV DXE SURFACE MOUNTED 3,75 PHV1500DXE NT PHV2000DXE NT 0 0,5 1,0 1,5 2,0 Technical specification Model PHV DXE Models Dimensions L x D x H (mm) Supply (50Hz) Heat Output (kw) COP Loading (A) Velocity (m/s) Air volume (m 3 /h) Weight (kg) db(a) @ 3m PHV1500DXE NT HO 1746 x 377 x 255 400V-3P&N PHV2000DXE NT LO 2296 x 377 x 255 400V-3P&N PHV2000DXE NT HO 2296 x 377 x 255 400V-3P&N 50% 8.3 100% 14.4 50% 7.9 100% 14.1 50% 11.2 100% 21.3 3.7 2.5 3.7 2.9 3.2 2.4 12.7 1 9.0 2600 60 60 15.7 2 9.5 3300 78 61 15.7 2 9.0 3130 80 61 1 for units with electric heaters disabled, 240v power supply 1.8 amp load 2 for units with electric heaters disabled, 240v power supply 2.7 amp load PHV DXE RECESSED RANGE 3,50 PHV1500DXE R PHV2000DXE R 0 0,5 1,0 1,5 2,0 Technical specification Model PHV DXE R Models Dimensions L x D x H (mm) Supply (50Hz) Heat Output (kw) COP Loading (A) Velocity (m/s) Air Volume (m 3 /h) Weight (kg) db(a) @ 3m PHV1500DXE R HO 1650 x 436 x 296 400V-3P&N PHV2000DXE R LO 2240 x 436 x 296 400V-3P&N PHV2000DXE R HO 2240 x 436 x 296 400V-3P&N 50% 8.3 100% 14.4 50% 7.9 100% 14.1 50% 11.2 100% 21.3 3.7 2.5 3.7 2.9 3.2 2.4 12.7 1 9.0 2600 67 60 15.7 2 9.5 3300 85 61 15.7 2 9.0 3130 88 61 1 for units with electric heaters disabled, 240v power supply 1.8 amp load 2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

PHV DXE SURFACE MOUNTED 100 250 mm min. for pipes E D E 295 255 377 C A B C Electric Supply and Control Wiring Inlets PHV1500DXE NT PHV2000DXE NT A (mm) 1746 2296 B (mm) 1400 1896 C (mm) 700 948 D (mm) 1300 1824 E (mm) 650 912 168 36 M10 inserts x 6 mm Hot Gas Refrigerant Connection Liquid Line Refrigerant Connection PHV DXE RECESSED RANGE 436 Alternative position for Electrical Supply an Control Wiring Inlets 100 296 DECKENNIVEAU CEILING LEVEL 20-65mm 476 C Electric Supply and Control Wiring Inlets B A B PHV1500DXE R PHV2000DXE R A (mm) 1650 2240 B (mm) 800 1095 C (mm) 1690 2290 Cut-Out in Ceiling: Length (mm) 1655 2245 Width (mm) 445 445 55 314 140 M10 inserts x 6 mm Hot Gas Refrigerant Connection Liquid Line Refrigerant Connection www.thermoscreens.com

HEAT PUMP MR.SLIM, POWER-/ZUBADAN- INVERTER Technical Data- PUHZ range Models Dimensions LxWxH (mm) Supply (50hz) Loading A per phase Fuse Complete pipe length max. height Connections difference Communication cable Thermoscreens Mitsubishi Electric PHV1500DXE HO PUHZ-RP140YHA (Power Inverter) PUHZ-HRP125YHA (Zubadan Inverter) 950 x 330 x 1350 400V-3PN 6.37 16 75 30 943 x 330 x 1350 400V-3PN 4.91 16 75 30 s. 16 s. 16 PHV2000DXE LO PUHZ-RP140YHA (Power Inverter) PUHZ-HRP125YHA (Zubadan Inverter) 950 x 330 x 1350 400V-3PN 6.37 16 75 30 943 x 330 x 1350 400V-3PN 4.91 16 75 30 s. 16 s. 16 PHV2000DXE HO PUHZ-RP200YHA2 (Power Inverter) 950 x 330 + 30 x 1350 400V-3PN 8.8 32 120 30 s. 22 CONTROL SYSTEM Mitsubishi Electric Mr. Slim Kommunikationsleitung Connection cable Air Luftschleier curtain On/Off An/Aus Heating Heizung On/Off An/Aus Heating Heizung Auto/Low/High Auto/Niedrig/Hoch Thermoscreens PHV DXE Thermoscreens Control Bedieneinheit Unit

CONTROL OPTIONS MANUAL CONTROL The Thermoscreens air curtain have the option of a stand alone remote controller when the air curtain is not controlled by BEMS ( Building Energy Management System ). This controller has the following functions - 50% or 100% DIRTY FILTER INDICATOR Thermoscreens install a Dirty filter Indicator in every heat pump air curtain to indicate when the filter needs cleaning. The filter indicator schedule is based on fan operating hours and helps the customer to maintain and service the air curtain appropriately. - Ambient/heat switch - Auto Mode ( to ensure consistent comfort levels are thermostatically maintained) ADDITIONAL OPTIONS Standard colour RAL 9010, other RAL colours available on request Additional electrical heating for defrost period