Installer: (Name, address, telephone number)

Similar documents
Installer: (Name, address, telephone)

Installer: (Name, address, telephone)

Installer: (Name, address, telephone)

Installer: (Name, address, telephone number)

Installer: (Name, address, telephone number)

Installer: (Name, address, telephone)

MOTOR FOR SLIDING GATES SERIE GR8 220V

Risk assessment and analysis for swing gates

GATE INFORMATION PACK

Ditec DOR Folding doors operator

GUIDE TO INSTALLATION

Professional Instruments. Safe Gates. Regulations overview Safety for gates and doors Notice on the EN Certification

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

dhf General Information Automated Gates Guidance for enforcement bodies

Ditec DAS107PLUS User Manual IP2270EN.

Ditec QIK80EH Electromechanical barrier (Translation of the original instructions)

HULME MARTIN HEAT SEALERS

HULME MARTIN HEAT SEALERS

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS

Electromagnetic Locking Devices Performance Requirements

Spoonshine CUTLERY POLISHERS

The plant meets the requirements of the current FSS 5 Checklist for Vessel Process Plants

ST1. Mod. USE AND MAINTENANCE MANUAL

Guide to Gate Safety Legislation & the Machinery Directive

The New EMC Directive 2004/108/EC

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Motorised swing doors User manual (translation of the original instructions) IP2225EN

Sliding Gates White Paper 1 Sliding Gate Safety Third Edition

1. Terms defined in the Construction Products Regulation (CPR)

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz

GECE cm touch control ceramic hob. GECE cm touch control ceramic hob

Basically, the instruction handbook shall contain the following information:

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop

Waste water ejection unit

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

DHF Introduction DHF 2

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

The New EMC Directive 2004/108/EC

Monitored Pneumatic Valves On Series Ported Manifold

CE Marking and Technical Standardisation

Transition from GAD to the GAR July,

Specification for Rising Bollards Control System

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

INTERNATIONAL STANDARD

½ Monitored Pneumatic Valves On Series Ported Manifold

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

CE marking & your legal obligations

British Standards for Machinery Guarding

CTA15-2 warming drawer. operating and installation instructions

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

IMPORTANT SAFETY INFORMATION

INTERNATIONAL STANDARD

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

GB User and maintenance manual

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

Introduction to machine safety

Health & Safety and Installation guide

51AKS I S O OWNER S MANUAL

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

INTERNATIONAL STANDARD

EXHIBITION SITE. fieramilanocity. Exhibition Site Safety Document (An. IV and V Min. Decree 22/7/2014)

Non-contacting guards

Role of CE Marking in the Placing on the Market of Electronic Components

SAFETY STANDARDS & SOLUTIONS MATERIAL HANDLING & INTRALOGISTICS

English... 5 Čeština Slovenčina Magyarul Polski Русский... 85

TTV 4500 / TTV 4500 HP / TTV 7000

INTERNATIONAL STANDARD

Kitchen Appliance Lift INSTRUCTION MANUAL

WIND TURBINE DAMAGE PREVENTION

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Introduction to machine safety

Council Directive 93/68/EEC of 22 July 1993 amending Directives

INTERNATIONAL STANDARD

VL FOREVER 600 INOX - VL FOREVER VL FOREVER 600 PRO

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

INSTRUCTIONS AND ADVICE FOR THE USE, INSTALLATION AND MAINTENANCE OF BUILT-IN ELECTRIC HOBS

INTERNATIONAL STANDARD

Lawnmowers (pedestrian controlled, battery powered)

SAFETY AND OPERATING MANUAL

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Snifter ATEX22 VERSION. User Manual. Distributor

HR 601 C A AUS. ENGLISH Instructions for use Page 2

OPERATING INSTRUCTIONS

ESSENTIAL REQUIREMENTS CHECK LIST

INTERNATIONAL STANDARD

MOULD WITH ENTERING PUNCHES

Valve Manufacturers Association of America

Electrostatic Precipitator

Bowker Machinery Ltd

Transcription:

Installer: (Name, address, telephone number) UNAC GUIDE No. 11 FOR THE MOTORISATION OF HINGED PEDESTRIAN DOORS IN ACCORDANCE WITH THE MACHINERY DIRECTIVE 98/37/EEC AND THE STANDARDS pren 12650-1* - pren 12650-2* * The standards mentioned are provisional and refer to the January 2002 version With this publication UNAC sets out to inform and assist installers in applying the specifications of the directives and of European standards concerning the safe use of motorised gates/doors. It should be noted that those who sell and motorise an existing manual door/gate become the manufacturer of the motorised door/gate machine and must prepare and keep the technical file, as laid down by Annex V of the Machinery Directive (98/37/EEC). The technical file must contain the following documents: Assembly drawing of the motorised door/gate (usually included in the installation manual). Electrical connections and control circuit diagrams (usually included in the installation manual). Risk analysis including (as indicated on the following pages): the list of the essential requirements as indicated in Annex I of the Machinery Directive; the list of the risks presented by the door/gate and the description of the solutions adopted. They must also keep the manuals for installation and maintenance of the door/gate and of the components. Prepare the operating instructions and general warnings for safety (if necessary integrating those in the manual for installation of the door/gate) and give the user a copy. Compile the proof book and give the user a copy (see facsimile in Annex 1). Draft the EC declaration of conformity (see facsimile in Annex 3) and give the user a copy. Fill in the label or plate with CE marking and attach it to the motorised door/gate. N.B. The technical file must be held and made available to the competent national authorities for at least ten years from the date of construction of the motorised door/gate. Risk areas of the hinged door (Figure 1) The information given was drafted and checked with the utmost care, nevertheless UNAC declines all responsibility for any errors, omissions or inaccuracies due to technical or graphical requirements. UNAC points out that this guide does not replace the content of standards which the manufacturer of the motorised door/gate must observe. - 1 - UNAC Guide No. 11 May 2005

KEY TO THE MECHANICAL RISKS CAUSED BY MOVEMENT OF THE DOOR Pursuant to the Machinery Directive: Danger zones refer to any zone within and/or around machinery in which an exposed person is subject to a risk to his or her health and safety. Exposed person refers to any person wholly or partially in a danger zone. Impact Crushing Shearing Dragging Cutting Hooking ANALYSIS OF THE RISKS AND CHOICE OF SOLUTIONS IN ACCORDANCE WITH THE MACHINERY DIRECTIVE 98/37/EEC AND THE STANDARDS EN 13241-1, EN 12453, EN 12445 The risks listed below follow the sequence of the installation process. These risks are those which are commonly present in motorised doors/gates systems. According to the various situations, consideration therefore has to be made of any possible additional risks and exclude those which are not applicable. The solutions to be adopted are those indicated by the standards mentioned above; in the case of risks not dealt with, the safety integration principles indicated by the Machinery Directive (Annex 1 1.1.2) have to be applied. MD 1.3.1 1.3.2 Mechanical, structural and wear risks ) 1.1.2 [1] Preliminary checks. Before starting installation or starting up an automatic door, an inspection has to be carried out on site by professionally skilled staff. This inspection is for evaluating risks and choosing and applying the most appropriate solutions according to the type of pedestrian traffic (intense, limited, one-way, two-way, etc.), the type of users (including the disabled, children, etc.) and the presence of potential dangers or special local situations. The result of this inspection is recorded by compiling this risk analysis. [2] Loss of stability and break-up. Check the solidity of the structure installed (architraves, jambs, walls, locks, hinges and leaves) in relation to the weight of the leaves and the forces generated by the drive unit. Attach the drive unit stably, using adequate materials and following the instructions in the installation manual. Check that the travel of the leaves is limited (during opening and closing) by mechanical stops of adequate strength. Check that the leaves cannot come out of their pintles or hinges and fall (for example through lifting). 1.5.15 [3] Tripping. Any thresholds in the ground area of the transit space of the door must be appropriately shaped and indicated. 1.1.3 1.3.4 [4] Materials. To build sliding and fixed leaves use materials whose possible breakage does not involve risks of injury. For example, with framed leaves, use laminated safety glass, and for leaves without a frame used hardened glass. Transparent leaves must be appropriately indicated. N.B. Avoid contact between glass and other rigid materials (glass, iron, etc.). - 2 - UNAC Guide No. 11 May 2005

1.3.7 1.3.8 1.4 Mechanical risks due to movement of the door. Choose one of the following types of installation. [5] SOLUTION 1 Impact and crushing on the closing edge (Figure 1, risk A) Measure the closure forces (using the instrument required by the standard pren 12650-1) as illustrated, and check that the values measured by the instrument are below those indicated in the graph. Force IMPACT CRUSHING time The graph shows the maximum values of the dynamic, static and residual operating forces, in relation to the various positions of the door. To avoid the risk of the leaves hitting people and causing them to fall (for example the elderly who use a walking stick), the installation of opening sensors is recommended with sensing of presence in the whole transit area, installed if necessary on the mobile leaf. So as to avoid non-monitored side passages, it is possible to border the accesses by means of fixed guards. [5] SOLUTION 2 Impact and crushing on the closing edge (Figure 1, risk A) Install presence sensing devices (in accordance with the standard EN 12978) that monitor the area of movement of the closing leaves. N.B. The test specimen for presence sensing is a parallelepiped (700 x 300 x 200 mm) with 3 faces with a light and reflective surface and 3 faces with a dark and opaque surface. Specimen for presence sensing - 3 - UNAC Guide No. 11 May 2005

[5] SOLUTION 3 Impact and crushing on the closing edge (Figure 1, risk A) Install a safety mat (in accordance with the standard EN 12978) in the area of movement of the leaves. N.B. The mat must be embedded in the floor, or have ramped edges, in order to avoid a step threshold. Safety mat Specimen for presence sensing [6] SOLUTION 1 Impact and crushing on the opening edge (Figure 1, risk B) Check that the safety distances illustrated exist, in the two different cases. [6] SOLUTION 2 Impact and crushing on the opening edge (Figure 1, risk B) Measure the opening forces (using the instrument required by the standard pren 12650-1) as illustrated, and check that the values measured by the instrument are below those indicated in the graph. Force IMPACT CRUSHING The graph shows the maximum values of the dynamic, static and residual operating forces, in relation to the various positions of the door. time - 4 - UNAC Guide No. 11 May 2005

[6] SOLUTION 3 Impact and crushing on the opening edge (Figure 1, risk B) Install presence sensing devices (in accordance with the standard EN 12978) which monitor the area of movement of the leaf during opening. N.B. The test specimen for presence sensing is a parallelepiped (700 x 300 x 200 mm) with 3 faces with a light and reflective surface and 3 faces with a dark and opaque surface. Specimen for presence sensing [7] Dragging of hands in the points of rotation of the hinged door (Figure 1, risk C). Check that the safety distances illustrated exist, in the three difference cases; or Attach a rubber strip resistant to penetration of fingers. Rubber Strip Rubber Strip [8] Dragging, hooking and cutting due to shaping of the mobile leaves. Eliminate or protect any sharp edges, handles, projecting parts, etc. (for example by covers or strips in rubber). MD Type of risks 1.5.1 1.5.2 1.5.10 1.5.11 Electrical and electromagnetic compatibility risks [9] Direct and indirect contacts. Dispersion of electrical energy. [10] Risks relating to electromagnetic compatibility. Use CE-marked components and materials pursuant to the Low Voltage Directive (73/23/EEC). Carry out the electrical connections, connection to the mains, earth connections and relevant checks, in accordance with current regulations and as indicated in the installation manual of the drive unit. N.B. If the electrical supply line is already set up (via both a socket and a connector block), declarations of conformity to Italian law no. 46/90 are not necessary. Use CE-marked components pursuant to the EMC Directive (89/336/EEC). Carry out the installation as indicated in the manual for installation of the drive unit. - 5 - UNAC Guide No. 11 May 2005

Type of risks Safety and reliability of drive unit and control and safety devices. 1.2 [11] Safety conditions in the event of malfunctioning and power failure. Use drive units which comply with the standard pren 12650-1 and safety devices which comply with the standard EN 12978. 1.5.3 [12] Energy types other than electrical energy If hydraulic drive units are used, they must comply with the standard EN 982; or if pneumatic drive units are used, they must comply with the standard EN 983. 1.2.3 1.2.4 [13] Actuation and disabling of the drive unit. Check that, after a fault or power failure, the drive unit restarts safely without creating hazardous situations. [14] Power supply switch. Install an omnipolar switch for electrical insulation of the door/gate (or use an electrical plug), in accordance with current laws. This switch (or plug) must be positioned or protected against accidental or unauthorised actuation. 1.5.14 [15] Risk of trapping. Check that the force necessary for opening or closing the door manually does not exceed 220 N. 1.2.4 1.2.5 [16] Emergency stop. [17] Opening controls. If appropriate, install an emergency stop control in accordance with the standard EN 418. N.B. Make sure that the emergency stop does not introduce additional risks, aborting operation of the safety devices installed. If movement sensing devices are used, they should be installed in order to monitor an area of at least 1500 mm from the leaf (completely open, in the case of opening contrary to the direction of transit). N.B. Check that the movement sensors see the whole width of the transit space. So as to avoid non-monitored lateral passages, the accesses can be bordered by fixed guards. If mats are used, they should be installed in order to cover the whole width of the transit space (minus 75 mm maximum) and in order to cover a distance of 1000-1500 mm from the leaf (fully open, in the case of opening contrary to the direction of transit). They must also be embedded in the floor, or have ramped edges, in order to avoid a step threshold. Should 2 mats be placed adjacent, the inactive distance must not exceed 60 mm. The photocells used as opening control are only suitable if used by trained staff. They should be installed 1000-5000 mm from the leaf (fully open, in the case of opening contrary to the direction of transit) and at a height of 300-1000 mm from the floor. If manual controls are used (for example pushbuttons, magnetic cards, etc.), they must be appropriately positioned and indicated in order to prevent risks or accidental actuation - 6 - UNAC Guide No. 11 May 2005

Environmental risks 1.5.7 [18] Risk of explosion. If the door is installed in areas with a risk of explosion, it must comply with the requirements of the ATEX directive (94/9/EEC). The electrical parts must comply with the standard EN 50020. [19] Low energy doors used for the transit of the disabled. The low energy hinged doors (no higher than 1.6 J) must be able to be regulated so that the minimum times of opening and closure of the leaf (to move through 80 ) are in accordance with the table below. Width of the Weight of the leaf leaf 50 kg 60 kg 70 kg 80 kg 90 kg 750 mm 3.0 s 3.1 s 3.2 s 3.3 s 3.5 s 850 mm 3.1 s 3.1 s 3.2 s 3.4 s 3.6 s 1,000 mm 3.2 s 3.4 s 3.7 s 4.0 s 4.2 s 1,200 mm 3.8 s 4.2 s 4.5 s 4.8 s 5.1 s The minimum time of deceleration of the leaf during closure (last 10 ) must be 1.5 s. The time of stopping of the door in an open position must not be less than 5 s. The static force developed by the drive unit must be less than 67 N (measured at 25 mm from the main closing edge). Doors for the disabled must be indicated by appropriate signs. N.B. If required by the evaluation of risks, install safety devices so as to prevent contact between the leaf and the person. [20] Doors used as an escape route and emergency exit. The leaf of the hinged door must open in the direction of escape by a push not greater than 220 N, attached to the closing edge at a height of 1000 mm. N.B. Doors used as escape routes and as fire doors (class A) must be certified by an authorised organisation. 1.5.6 [21] Fire doors. The drive unit must close the door automatically after a fire alarm control or in the absence of power supply. Integration principles for safety and information. 1.7.1 1.7.2 [22] Warnings In the case of clear glass leaves, attach clearly visible marking. Any manual release devices and emergency pushbuttons must be adequately indicated. Use signs to indicate the use of doors with one-way transit (entrance only/exit only). Attach all those signs or warnings considered necessary for indicating any unprotected residual risks and to indicate any foreseeable improper use. 1.7.3 [23] Marking. Attach the label identifying the product and the manufacturer, with the CE marking. 1.7.4 [24] Instructions. Consign to the user the operating instructions, safety warnings and EC declaration of conformity (cf. facsimile in Annex 3). 1.6.1 1.1.2 [25] Maintenance. [26] Unprotected residual risks. A maintenance plan has to be drawn up and implemented. Check on the proper working of the safety devices at least once a year. Record the work carried out in the proof book (cf. facsimile in Annex 1). Inform the user in writing (for example in the operating instructions) of any unprotected residual risks and foreseeable improper use. - 7 - UNAC Guide No. 11 May 2005