CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Similar documents
SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500

INSTALLATION INSTRUCTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

MODELS K2EU060A, K4EU090A, & K3EU120A

ACCESSORY KIT INSTALLATION INSTRUCTIONS

VariCool VAV Engineering Guide

C13-Series Engineering Guide

VertiCool Aurora Engineering Guide

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

INSTALLATION INSTRUCTION-50 Hz

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER MODEL: LA120 NOTES, CAUTIONS AND WARNINGS SAVE THIS MANUAL B-0203

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

INSTALLATION INSTRUCTION

JCseries EVAPORATIVE CONDENSER. engineering data

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

CoolSpot Engineering Guide

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

Advance Release September 2009

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

COMMERCIAL AIR HANDLER

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Water-Cooled Self-Contained Units

Split System Heat Pumps

PACKAGE AIR CONDITIONER

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

Modular Supply Make-Up Air Unit

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

technical guide Water-Cooled Self-Contained Units

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

COMMERCIAL AIR HANDLER

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

CWA4 Chilled & Hot Water Fan Coil

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Commercial High-Efficiency Condensing Units

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

INSTALLATION INSTRUCTION

SSL & SBS Engineering Guide

Cooling/Heat Pump Convertible Air Handlers

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Cooling/Heat Pump Convertible Air Handlers

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

40 RM/RMS Packaged Air-Handling Units

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Service Step by Step Trouble-Shooting Check-List

Cooling/Heat Pump Convertible Air Handlers

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

50TM COMBINATION HEATING/COOLING UNITS

1.1 This section applies to air handling units for HVAC Systems.

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

Cabinet Unit Heaters Steam / Hot Water

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

CHAMPION SPLIT-SYSTEM CONDENSING UNITS (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: N4 (778) N4Y (492)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Installation, Start-Up and Service Instructions

50TM TFF COMBINATION HEATING/COOLING UNITS

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM HEAT PUMP FOUR PIPE SYSTEM DESCRIPTION E*FB180 & 240 F*EH180 & & 20 NOMINAL TONS INDOOR UNIT

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Transcription:

550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The units are shipped as single packages with the blower module mounted on top of the coil module, but the blower module can be repositioned in the field to meet almost any installation requirement. The following illustration shows three of the more common installation arrangements. Refer to the unit installation instruction for other possibilities. The blower module includes the blower wheels and room for a field-mounted motor and drive. The coil module includes direct expansion coils, 1" throwaway filters, liquid line solenoid valves for both capacity reduction and pumpdown, thermal expansion valves, distributors and a condensate drain pan. Each evaporator coil is pressurized with air to 325 psig and leak tested under water. After the headers are brazed onto the coil and the coil is installed in the unit, the coil will be pressurized with a combination of refrigerant-22 and nitrogen to 150 psig for pressure testing and additional leak testing. After the coil is evacuated and dehydrated, it will be pressurized with a holding charge of refrigerant-22 for storage and/or shipping. A supply air plenum, return air grille, steam coil, hot water coil, base section, suspension hardware, blower motors and drive accessories are available for field-installation to provide additional application flexibility. This evaporator blower, applied with a matching condensing unit, will provide years of quiet, efficient and dependable operation. FEATURES APPLICATION FLEXIBILITY - This evaporator blower can be arranged for a variety of air discharge patterns in either the horizontal or the vertical position. The unit can be bottom-supported or ceiling-suspended and can be arranged to meet almost any space or duct requirements. Each unit is available with a choice of blower motors, drive packages plus other accessories to make them suitable for most applications. PART LOAD OPERATION - Each evaporator blower has multiple coils with pre-piped distributors, expansion valves and solenoid valves. They require no field modifications for part load operation. Capacity reduction not only provides economical operation but also maintains more even temperature and humidity levels in the conditioned space. EASY SERVICE - Serviceable expansion valves are provided on every unit. These superior valves are factory-installed to provide many years of trouble-free operation. If service is required, you won t have to unbraze any joints. PUMPDOWN - Each evaporator blower includes a solenoid valve for non-recycling pumpdown. When the cooling requirement in the conditioned space is satisfied, the refrigerant will be pumped into the high side of the system.

550.23-TG5Y ACCESSORIES RETURN AIR GRILLE - This decorative, expanded metal grille will enhance the appearance of any unit that has no return air ductwork and is especially recommended for units located within the conditioned space. SUPPLY AIR PLENUM - This decorative, horizontal discharge plenum will enhance the appearance and performance of any unit that does not have supply air ductwork. It has the same durable finish as the evaporator blower, is fully insulated, is shipped ready for mounting on horizontal or vertical units and has grilles which may be adjusted to meet the throw and spread requirements of the conditioned space. BASE SECTION - The base section can be used to elevate units off the floor. If desired, outdoor air may be introduced thru these sections by cutting an access opening to accommodate the outdoor air duct connection. The base has a durable finish to match the evaporator blower unit. It may have to be insulated for certain applications. SUSPENSION PACKAGE - This accessory can be used to suspend horizontal units from above without interfering with access to the unit. It can also be used for elevating a floor-mounted unit (either horizontal or vertical) to provide additional height for the installation of a trap at the condensate drain connection. A suspension package can be used with vibration isolators. HOT WATER COIL - A drainable water coil is available for field installation between the blower and the coil modules of both horizontal and vertical units. Since their casings match the dimensions and the finish of the basic units, they become an integral part of the unit after installation. The coil slides out of its casing for easy installation. The coil has copper tubes that have been mechanically expanded into aluminum fins. Both headers are located on the same end of the coil. Each coil is leak-tested at 325 psig under water and dried before their connections are capped for storage and shipping. STEAM COIL - A steam coil is available for field installation between the blower and coil modules of both horizontal and vertical units. Since their casings match the dimensions and the finish of the basic units, they become an integral part of the unit after installation. The coil slides out of its casing for easy installation and is pitched in its casing to facilitate condensate drainage. The coil has copper tubes that have been mechanically expanded into aluminum fins. Both headers are located on the same end of the coil. Each coil is leak-tested at 325 psig and dried before their connections are capped for storage and shipping. BLOWER MOTORS - Different HP motors are available to meet almost any air delivery requirement. All motors are UL approved, have inherent protection, permanently lubricated ball bearings and get field-mounted within the insulated cabinet of the unit to minimize the transmission of sound to the surrounding space. DRIVE PACKAGES - Different size pulleys and belts are available to provide a blower RPM range to meet almost any air delivery requirement. Variable pitch motor pulleys can be adjusted to provide the proper blower RPM. All drive packages are rated at least 25% above the nominal HP rating of the blower motor. Two-groove pulleys and two belts are provided on every drive package rated at 5 HP. PHYSICAL DATA - Unit and Accessories Rows Deep 4 Rows High 24 Evaporator Coil Finned Length (in.) 83 Fins / Inch 12 Tube OD (in.) 1/2 Face Area (Sq. Ft.) 17.4 Centrifugal Blowers Wheel Dia. x Width (in.) (2 Per Unit) 15 x 12 (8) Quan. & Size (in.) Filters (Throwaway) 20 x 22 x 1 Face Area (Sq.Ft.) 24.1 Operating Charge (Refrigerant-22) Lbs.-Oz. 12-0 Drainable, Hot Water Coil Non-Freeze, Steam Distributing Coil Weight (Lbs.) Operating Weight, (Lbs.) *Less Motor and Drive. ELECTRICAL DATA Motor Rating 1 Power Supply Rows Deep 2 Fins / Inch 8 Tube OD (in.) 1/2 Face Area (Sq.Ft.) 14.5 Supply/Return (Copper) OD (in.) 1-3/8 Rows Deep 1 Fins / Inch 8 Tube OD x ID (in.) 1 x 5/8 Face Area (Sq.Ft.) 13.5 Inlet/Outlet (Brass) NPTE (in.) 1-1/2 Shipping* 800 Operating 690 Motor & Drive 3 HP 90 5 HP 120 Supply Air Plenum 150 Base 120 Return Air Grille 15 Steam Coil 150 Hot Water Coil 150 Nameplate Amps Locked Rotor Amps Min. Wire Size, 2 (AWG) Max. Wire Length, 3 (Ft.) Max. Fuse Size, 4 (Amps) 208-3-60 10.6 70.4 14 105 20 3 HP 230-3-60 9.2 61.2 14 140 15 460-3-60 4.6 30.6 14 550 8 208-3-60 13.6 86.0 12 135 25 5 HP 230-3-60 13.4 85.0 12 150 25 460-3-60 6.7 42.5 14 385 12 1 For additional motor data, refer to blower motor and drive data table. 2 Based on three, 60 C insulated copper conductors in steel conduit. 3 Based on an 80% power factor and a 3% voltage drop. 4 Dual element, time delay fuses. 2 Central Environmental Systems

550.23-TG5Y FIELD WIRING THERMOSTAT 2TH04701224 W / SUBBASE HCE180/LEU240 THERMOSTAT 2TH04701224 W / SUBBASE HCE240/LEU240 SUPPLY AIR BLOWER PERFORMANCE 1 CFM RPM* ESP 2 BHP 3 KW ESP 2 BHP 3 KW ESP 2 BHP 3 KW ESP 2 BHP 3 KW ESP 2 BHP 3 KW 6400 7200 8000 8800 9600 600.25 1.4 1.2.10 1.7 1.5 - - - - - - - - - 700.57 1.8 1.6.43 2.1 1.8.26 2.4 2.1.06 2.8 2.4 - - - 800.95 2.3 2.0.83 2.6 2.3.67 2.9 2.5.50 3.4 2.9.30 4.0 3.5 900 1.34 2.8 2.4 1.23 3.2 2.8 1.09 3.7 3.2.94 4.3 3.7.75 5.0 4.3 1000 1.74 3.4 2.9 1.63 4.0 3.5 1.51 4.7 4.1 1.37 5.4 4.7 - - - 3 HP Motor 5 HP Motor *Min./Max. speed for 3 HP drive accessory is 600/775 RPM. Min./Max. speed for 5 HP drive accessory is 775/970 RPM. 1 Unit resistance is based on a wet evaporator coil and clean filters. 2 Available ESP (external static pressure) in IWG to overcome the resistance of the duct system and any accessories added to the unit. Refer to the blower motor and drive data table and the accessory static resistance table for additional information. 3 Motors can be selected to operate into their service factor because they are located in the moving air stream, upstream of any heating device. Units with steam or hot water coils are the only exception. On these units, the BHP must not exceed the nominal HP rating of the motor. NOTE: Refer to Form 550.13-AD1.1 for blower performance curves. BLOWER MOTOR AND DRIVE DATA Drive Motor Blower Pulley Motor Pulley Belt Model No. RPM Range HP 1 Frame Shaft Size Mfgs. No. Size Mfgs. No. Size 1LD0404 600-775 3 56 7/8 A55 AK104 10 X 1-3/16 1VM50 3.4-4.4 x 7/8 1LD0406 775-970 5 184 1-1/8 A51 2 2AK94 9 X 1-3/16 2VP56 4.0-5.0 x 1-1/8 1 All motors are 1750 RPM and have a 1.15 service factor. 2 Two matched belts. Central Environmental Systems 3

550.23-TG5Y HEATING COIL CAPACITIES HOT WATER COIL CAPACITY*, Mbh Hot Water Coil Entering Water Temp. Minus Entering Air Temp., F Unit Model GPM CFM 70 90 110 130 150 6,400 179 229 280 331 382 1HW0405 LEU240 35 8,000 199 255 312 369 425 9,600 220 282 344 407 469 *These capacities do not include any blower motor heat. NOTE: Water Temperature Drop ( o F) = 2 x MBH GPM CAPACITY CORRECTION AND PRESSURE DROP VS GPM CAUTION: Do NOT operate the supply air blower motor above its nominal HP rating when a unit is equipped with a hot water coil accessory. Do NOT use steam in these hot water coils. Hot Water Coil Pressure Drop + Capacity Correction GPM PSI Factor 15 0.2 0.74 35 0.8 1.00 1HW0405 55 1.5 1.04 75 2.5 1.06 + For pressure drop in feet (water), multiply these values by 2.31. STEAM COIL CAPACITY 1, Mbh @ 2 psig 2 Steam Coil Dry Bullb Temperature of Air Entering Coil, F Unit Model CFM 10 30 50 70 6,400 402 364 325 286 1NF0453 LEU240 8,000 464 419 374 330 9,600 481 435 388 342 1 These capacities do not include any blower motor heat. 2 Multiply these capacities by the following factors to correct for higher steam pressures. Steam pressure, psig 5 10 15 20 25 Capacity correction factor 1.05 1.12 1.19 1.25 1.30 NOTE: Steam rate (lbs./hr.) = 1.025 x MBH. CAUTION: Do NOT operate the supply air blower motor above its nominal HP rating when a unit is equipped with a steam coil accessory. Although these coils are suitable for much higher pressures, steam above 25 psig will provide too much heat and could damage the blower motor. ACCESSORY STATIC RESISTANCES (IWG) CFM Supply Air Plenum Return Air Grille Non- Freeze Steam Coil Hot Water Coil 6400.03.04.14.07 7200.03.05.17.08 8000.04.06.21.10 8800.05.07.25.12 9600.06.08.29.14 PLENUM PERFORMANCE CFM Throw, Feet Minimum Maximum 6400 80 145 8000 98 165 9600 115 185 4 Central Environmental Systems

COIL CIRCUITING - Liquid Line 550.23-TG5Y UNIT DIMENSIONS ACCESSORIES Heating Coil - Add 6" to overall unit height when used. Plenum - Add 24-5/8" to overall unit height when used. Base - Add 23-3/8" to overall unit height when used. CLEARANCES 24" on one side for piping connection and access to blower motor. 1" on opposite side. 1" on rear. APPROX. SHIPPING WT. (Less Motor and Drive) LEU240-800 lbs. All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. A B C D E F G H J K L M N P 89-1/2 85 26-1/8 29-1/2 59 2-7/16 15-7/8 12-7/16 20-3/4 16 16 20-3/4 1 1-5/8 Central Environmental Systems 5

550.23-TG5Y ACCESSORY DIMENSIONS SUPPLY AIR PLENUM - Model 1SP0405 SHIPPED KNOCKED DOWN FOR FIELD ASSEMBLY RETURN AIR GRILLE - Model 1RG0405 BASE SECTION* - Model 1BS0405 SHIPPED KNOCKED DOWN FOR FIELD ASSEMBLY *Ventilation air can be brought into the unit through the base section providing the base section is fully insulated in the field. 6 Central Environmental Systems

ACCESSORY DIMENSIONS (Cont d.) 550.23-TG5Y HOT WATER COIL* - Model 1HW0405 *Coil is field-installed between the evaporator coil and the blower section of the unit. STEAM COIL* - Model 1NF0453 *Coil is field-installed between the evaporator coil and the blower section of the unit. SUSPENSION KIT - Model 1HH0451 BASIC UNIT SUSPENSION WEIGHTS (Lbs.) Suspension Point w/3 HP Motor* A 142 B 132 C 152 D 162 E 132 F 127 Total Weight 847 *Motor location at suspension point F. Central Environmental Systems 7

P.O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A Copyright by York International Corporation 1993. All Rights Reserved. Code: EBY, EGY 550.23-TG5Y Supersedes: Nothing