Installation Guide for models:

Similar documents
Installation Guide for models:

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Series. Access Power Controllers. Installation Guide

Access Power Controllers with Power Supplies

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

SP-1000X. Panic Device Power Controller Installation Guide. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Rack Mount Series Installation Guide

AL600ULX Series. Power Supply/Charger. Installation Guide

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

AL800ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

more than just power! Altronix is the professional security industry s leading manufacturer

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Booster Power Supply Manual

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Remote NAC Power Supply D7038

MODEL B2 INSTALLATION MANUAL

MR-2602 Two Zone Fire Alarm Control Panel

PSN-1000 & PSN 1000(E) Installation Manual

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

KT-100 Door Controller

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

RELEASE DEVICE CONTROLS

Model 17A00 Expansion Enclosure

AL602ULADA AL802ULADA AL1002ULADA

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

4100U City and Relay Cards Installation Instructions

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Notification Appliance Circuit Module

Addressable NAC Output Module D327A

EVO192 v3.0 Fire and Burglary What s New

Power Supplies. Overview

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

1. POWERPATH Operation

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Public Safety DAS Annunciator Panel

MANUAL RESET ALARM RELEASE

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

MANUAL RESET ALARM RELEASE

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

July 14, 1999 DF C-100.

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Commercial and Light Industrial Fire Alarm Control Panel

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

/9308 External Battery Chargers Installation Instructions

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MANUAL RESET ALARM RELEASE BOX

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

I TS-12 1 Y K DO WHAT THEY DON T. Model. INSTALLATION lnstrljctlons. FIRE BURGLARY lnstrumentsrn INC.

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Transcription:

140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Sixteen (16) fuse protected power-limited outputs. Maximal33F - Power Supply 1: 12VDC @ 5.3 amp or 24VDC @ 5.6 amp. - Power Supply 2: 12VDC @ 5.3 amp or 24VDC @ 5.6 amp. - Sixteen (16) fuse protected non power-limited outputs. Maximal55F - Power Supply 1: 12VDC @ 9.3 amp. - Power Supply 2: 12VDC @ 9.3 amp. - Sixteen (16) fuse protected non power-limited outputs. Maximal77F - Power Supply 1: 24VDC @ 9.6 amp. - Power Supply 2: 24VDC @ 9.6 amp. - Sixteen (16) fuse protected non power-limited outputs. Maximal75F - Power Supply 1: 12VDC @ 9.3 amp. - Power Supply 2: 24VDC @ 9.6 amp. - Sixteen (16) fuse protected non power-limited outputs. Altronix Corp. Rev. DFF051613 More than just power. Installing Company: Service Rep. Name: Address: Phone #:

MaximalF Series Overview: MaximalF Access Power/Controllers distribute and switch power to access control systems and accessories. They convert a 120VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form C contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed. Altronix Model Number Maximal11F Maximal33F Maximal55F Maximal75F Maximal77F 12VDC Output 10.1-10.1- MaximalF Series Configuration Chart: Nominal DC Output Voltage Options Power Supply 1 Power Supply 2 [DC] [AUX] [DC] [AUX] 24VDC Output ---------- 20.28-10.0-10.0- ---------- 20.19-10.03-10.03-12VDC Output 24VDC Output 12VDC Output 24VDC Output 12VDC Output 24VDC Output Maximum Supply Current for Main and Aux. Outputs (Power Supply 1/ Power Supply 2) (amp) eflow4nb eflow4nb ---------- ---------- 10.05- ---------- 10.05- ---------- ---------- 10.1- ---------- ---------- 20.28-20.2- ---------- 20.28- ---------- 10.05- ---------- ---------- ---------- 3.3A + 3.3A 20.2-20.2-3.3A + 3.6A 3.6A + 3.6A eflow6nb eflow6nb ---------- ---------- 10.0- ---------- 5.3A + 5.3A eflow102nb eflow102nb eflow104nb ---------- 20.17- ---------- 20.19- ---------- 20.28- ---------- ---------- 20.19- ---------- 20.19- ---------- ---------- 20.17- ---------- 20.19- ---------- 20.19- eflow102nb ---------- eflow104nb ---------- 20.28- ---------- 20.17- eflow104nb ---------- 20.28-5.3A + 5.6A 5.6A + 5.6A Fuse Protected Outputs 120VAC 60 Hz Input (current) Current per ACM8 output (amp) Power Supply Board Input Fuse Rating 16* 7A 2.5 16 7A 2.5 9.3A + 9.3A 16 7A 2.5 9.3A + 9.6A 16 8A 2.5 5A/ 5A/ 5A/ 5A/ (eflow102nb) 6.3A/ (eflow104nb) Power Supply Board Battery Fuse Rating 7.5A/ 32V 10A/ 32V 15A/ 32V 15A/ 32V 9.6A + 9.6A 16 9A 2.5 6.3A/ 15A/ 32V *Maximal11F only: This unit is classified as Power-Limited stand alone power supply with stand-by battery and it is suitable to power: sensors, electro-mechanical devices (e.g. electric door strikes). *Maximal33F, Maximal55F, Maximal75F and Maximal77F: The DC output for these power supplies are not power-limited. If a power-limited output is required in the end-product application, the DC output from the power supply must be connected to a separately Listed control unit or accessory board that provides power-limited outputs. The product(s) providing the power-limited output(s) must be listed as appropriate for the particular end-product application and wired in accordance with the products installation instructions. Class 1 wiring methods, separation of circuits, and proper fire-rated enclosures all must be considered when connecting the DC output of the power supply to the end-product devices. The auxiliary outputs of these units are power-limited. UL Listings for US Installations: UL 294 - UL Listed for Access Control System Units. UL Listings for Canadian Installations: ULC-S319-05 - Electronic Access Control Systems Class I equipment. CSA C22.2 No.205 - Signal Equipment. ULC-S319-05 Electronic Access Control Systems will be invalidated through the use of any add-on, expansion, memory or other module manufactured by the manufacturer or other manufacturers. ACM8 Board Input Fuse Rating 10A/ 10A/ 10A/ 10A/ 10A/ Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused) - 2 -

MaximalF Series Features: ACM8 Access Power Controller Modules: Sixteen (16) independently trigger controlled outputs. Output options: a) Sixteen (16) Fail-Safe filtered power outputs. b) Sixteen (16) Fail-Secure filtered power outputs. c) Sixteen (16) form C relay outputs (rated @ 5 amp/28vdc or VAC). d) Any combination of the above. Sixteen (16) Access Control System trigger inputs. Input trigger options: a) Sixteen (16) normally open (NO) dry trigger inputs. b) Sixteen (16) open collector inputs. c) Any combination of the above. Sixteen (16) unswitched filtered aux. power outputs (outputs are rated @ 2.5 amp). Red LEDs on ACM8 board indicate individual outputs are triggered (relays energized). Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs. Fire Alarm disconnect input trigger options: a) Normally open (NO) or normally closed (NC) dry trigger input. b) Polarity reversal input from FACP signaling circuit. Green LED on ACM8 board indicates FACP disconnect is triggered. FACP output relay indicates that FACP input is triggered (form C contact rated @ 1 amp/28vdc not evaluated by UL). eflow Power Supply/Charger provides common power for ACM8 board (factory wiring) and all connected access control devices (field wiring). ACM8 board main fuses are rated @ 10 amp. Output fuses are rated @ 2.5 amp. eflow Power Supply/Charger: Input: 120VAC, 60Hz. For output voltage and supply current, refer to MaximalF series Configuration Chart, pg. 2. Auxiliary Power-Limited output rated @ 1 amp (unswitched). Over Voltage Protection. Built-in charger for sealed lead acid or gel type batteries. Maximum charge current 1.54 amp. Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption. Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger. AC fail supervision (form C contacts). Battery fail & presence supervision (form C contacts). Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Fuse ratings, refer to MaximalF series Configuration Chart, pg. 2. Green AC Power LED indicates 120VAC present. AC input and DC output LED indicators. Short circuit and overload protection. Enclosure accommodates up to four (4) 12VDC/12AH batteries. Enclosure dimensions (H x W x D): 26 x 19 x 6.25 (660.4mm x 482.6mm x 158.75mm). Maximal Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, the Canadian Electric Code, Part I, Part II and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. Power Supply Board LED Diagnostics (pg. 5) Access Power Controller LED Diagnostics (pg. 5) Power Supply Board Terminal Identification (pg. 6) Access Power Controller Terminal Identification (pg. 6) Power Supply Board Stand-by Battery Specifications (pg. 7) Power Supply Board Output Voltage Settings (pg. 7) Access Power Controller Typical Application Diagram (pg. 7) FACP/Optional Power Supply Hook-up Diagrams (pg. 10) 1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 12). - 3 - Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused)

2. Connect unswitched AC power (120VAC 60Hz) to terminals marked [L, N] (Fig. 3, pg. 8). Use 14 AWG or larger for all power connections. Secure green wire lead to earth ground. Keep power-limited wiring separate from non power-limited wiring. Minimum 0.25 spacing must be provided (Fig. 3, pg. 8). CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel. 3. Select desired DC output voltage by setting SW1 to the appropriate position on the power supply board (Maximal11F and Maximal33F), (Fig. 1, pg. 7). Maximal55F power supply is factory set at 12VDC. Maximal77F power supply is factory set at 24VDC. Maximal75F consists of one (1) power supply board that is factory set at 12VDC, and one (1) power supply board that is factory set at 24VDC. 4. Measure the output voltage of the unit before connecting any devices to ensure proper operation. Improper or high voltage will damage these devices. 5. Output options (Fig. 2, pg. 7): The unit will provide either sixteen (16) switched power outputs, sixteen (16) dry form C outputs, or any combination of both switched power and form C outputs. (a) Fail-Safe Switched Power outputs: For Fail-Safe operation connect the positive (+) input of the access control devices to terminal marked [NC]. Connect the negative (-) input of the access control devices to terminal marked [COM]. (b) Fail-Secure Switched Power outputs: For Fail-Secure operation connect the positive (+) input of the access control devices to terminal marked [NO]. Connect the negative (-) input of the access control devices to terminal marked [COM]. (c) Form C outputs: When form C outputs are desired the corresponding output fuses (1-8) of each ACM8 board must be removed. 6. ACM8 Auxiliary Power outputs (unswitched): Connect access control devices that require constant power to terminals marked [C] positive (+) and [COM] negative (-). Outputs can be used to provide power for card readers, keypads etc. eflow Auxiliary outputs (unswitched): For auxiliary device connection this output will not be affected by Low Power Disconnect or Fire Alarm Interface. Connect device to terminals marked [+ AUX -- ] (Fig. 3, pg. 8). 7. Input trigger options (Fig. 2, pg. 7): (a) Normally Open [NO] input trigger: Inputs 1-8 are activated by normally open or open collector sink inputs. Connect access control panel outputs, keypads, push buttons, REX PIRs, etc. to terminals marked [IN] and [GND]. (b) Open Collector Sink inputs: Connect the access control panel open collector sink positive (+) to terminals marked [IN] and the negative (-) to terminals marked [GND]. 8. ACM8 Fire Alarm Interface options (Figs. 5-9, pg. 10): A normally closed [NC] or normally open [NO] input trigger from a fire alarm control panel or a polarity reversal input from an FACP signaling circuit will affect selected outputs. To enable FACP Disconnect for an output, open the corresponding switch(es) [SW1-SW8] on each ACM8 board. To disable FACP disconnect for an output, close the corresponding switch(es) [SW1-SW8] on each ACM8 board. (a) Normally Open [NO] input: For non-latching hook-up refer to (Fig. 6, pg. 10). For latching hook-up refer to (Fig. 7, pg. 10). (b) Normally Closed [NC] input: For non-latching hook-up refer to (Fig. 8, pg. 10). For latching hook-up refer to (Fig. 9, pg. 10). (c) FACP Signaling Circuit input trigger: Connect the positive (+) and negative (-) from the FACP signaling circuit output to the terminals marked [+ INP -]. Connect the FACP EOL to the terminals marked [+ RET -] (polarity is referenced in an alarm condition). Jumper J3 must be cut (Fig. 5, pg. 10). 9. FACP Dry form C output (Not evaluated by UL) (Fig. 2a, pg. 7): FACP form C contacts can be use to trigger reporting or signaling devices. These contact switch upon a fire alarm input trigger to the ACM8 boards. 10. Stand-by Battery Connections (Figs. 3, pg. 8): For U.S. Access Control applications batteries are optional. Batteries are required for Canadian installations (ULC-S319). When batteries are not used, a loss of AC will result in the loss of output voltage. When the use of stand-by batteries is desired, they must be lead acid or gel type. Connect battery to terminals marked [-- BAT + ] (Fig. 3, pg. 8). Use two (2) 12VDC batteries connected in series for 24VDC operation (battery leads included). Use batteries - Casil CL1270 (12V/7AH), CL12120 (12V/12AH), CL12400 (12V/40AH), CL12650 (12V/65AH) batteries or UL recognized BAZR2 and BAZR8 batteries of an appropriate rating. 11. Battery and AC Supervision outputs (Fig. 3, pg. 8): It is required to connect supervisory trouble reporting devices to outputs marked [AC Fail, BAT Fail] supervisory relay outputs marked [NC, C, NO] to appropriate visual notification devices. Use 22 AWG to 18 AWG for AC Fail & Low/No Battery reporting. Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused) - 4 -

12. To delay AC reporting for 2 hrs., set dip switch [AC Delay] to OFF position (Fig. 3, pg. 8). To delay AC reporting for 1 min., set dip switch [AC Delay] to ON position (Fig. 3, pg. 8). 13. Low Power Shutdown (Fig. 3, pg. 8): To enable Low Output Power Shutdown, set dip switch [Shutdown] to ON position. To disable Low Output Power Shutdown, set dip switch [Shutdown] to OFF position. 14. Installation of tamper switch (Not Included) (Fig. 3b, pg. 8): Mount UL Listed tamper switch (Sentrol model 3012 or equivalent) at the top of the enclosure. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side (Fig. 3b, pg. 8). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal, open the door of the enclosure. 15. Multiple power supply inputs (Fig. 2, pg. 7) (Not evaluated by UL): When using an additional Listed external power supply, jumpers J1 and J2 located on corresponding ACM8 board must be cut (Fig. 2b, pg. 7 & Fig. 5, pg. 10). Connect external Listed power-limited access control power supply to the terminals marked [- Control +] (These terminals are paralleled to the - Power + terminals). When using DC power supplies, polarity must be observed. When using AC power supplies, polarity need not be observed. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute) (Fig. 4a, pg. 7). Maintenance: Unit should be tested at least once a year for the proper operation as follows: FACP Supervision: To ensure proper connection and operation of the Fire Alarm disconnect hookup. Please follow the appropriate procedure below: Normally Open Input: Placing a short between terminals marked [T] and [+ INP] will trigger the Fire Alarm Disconnect. Remove the short to reset. Normally Closed Input: Removing the wire from terminal marked [INP -- ] will trigger the Fire Alarm Disconnect. Replace the wire to terminal marked [INP -- ] to reset. FACP Signal Circuit Input: It is necessary to trigger the Fire Alarm System. In all of the above scenarios the green TRG LED of the ACM8s will illuminate. All outputs selected for Fire Alarm Disconnect will activate releasing locking devices. Note: All outputs [OUT 1 - OUT 8] must be in a normal (de-energized) condition prior to testing. When the unit is configured for Normally Open (Fig. 8, pg. 10) or Normally Closed (Fig. 10, pg. 10) latching operation, it is necessary to reset the Fire Alarm Disconnect by activating the Normally Closed reset switch. Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level (refer to MaximalF series Configuration Chart, pg. 2). Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage at the battery terminals and at the board terminals marked [+ BAT ] to ensure that there is no break in the battery connection wires. Note: Maximum charge current is 1.54 amp. Expected battery life is 5 years; however, it is recommended to change batteries within 4 years or less if necessary. Power Supply Board LED Diagnostics: Red (DC) Green (AC/AC1) Power Supply Status ON ON Normal operating condition. ON OFF Loss of AC, Stand-by battery supplying power. OFF ON No DC output. OFF OFF Loss of AC. Discharged or no stand-by battery. No DC output. Access Power Controller LED Diagnostics: LED ON OFF LED 1- LED 8 (Red) Output relay(s) energized. Output relay(s) de-energized. Trg (Green) FACP input triggered (alarm condition). FACP normal (non-alarm condition). - 5 - Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused)

Power Supply Board Terminal Identification: Terminal Legend Function/Description L, N Connect 120VAC 60Hz to these terminals: L to hot, N to neutral. Do not use terminal marked [G] + DC Factory connected to ACM8 board. Trigger EOL Supervised NO, GND RESET Fire Alarm Interface trigger input from a short or FACP. Trigger inputs can be normally open, normally closed from an FACP output circuit (power-limited input) (Fig. 3, pg. 8). FACP interface latching or non-latching (power-limited) (Fig. 3, pg. 8). + AUX Auxiliary Power-Limited output rated @ 1 amp (unswitched) (power-limited output) (Fig. 3, pg. 8). AC FAIL Indicates loss of AC power, e.g. connect to audible device or alarm panel. Relay normally energized NC, C, NO when AC power is present. Contact rating 1 amp @ 30VDC (power-limited) (Fig. 3, pg. 8). BAT FAIL NC, C, NO Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present. Contact rating 1 amp @ 30VDC. A removed battery is reported within 5 minutes. Battery reconnection is reported within 1 minute (power-limited) (Fig. 3, pg. 8). + BAT Stand-by battery connections. Maximum charge current 1.54 amp (non power-limited) (Fig. 3, pg. 8). Terminal Legend -- Power + -- Control + TRIGGER INPUT 1-INPUT 8 IN, GND OUTPUT 1- OUTPUT 8 NC, C, NO, COM FACP INTERFACE T, + INPUT -- FACP INTERFACE NC, C, NO Access Power Controller Terminal Identification: Function/Description 12VDC or 24VDC from power supply/charger (factory connected). These terminals are paralleled to the - Control + terminals. These terminals are paralleled to the - Power + terminals. These terminals can be connected to an external Listed power-limited access control power supply to provide isolated operating power for the devices (Not evaluated by UL) (jumpers J1 and J2 must be removed). From normally open and/or open collector sink trigger inputs (request to exit buttons, exit pir s, etc.) 12VDC to 24VDC trigger controlled outputs. Maximum load per output is 2.5 amp. Maximal11F: P/S 1-10.1-VDC @ 3.3 amp P/S 2-10.1-VDC @ 3.3 amp or P/S 1-20.28-VDC @ 3.6 amp P/S 2-20.28-VDC @ 3.6 amp or P/S 1-10.1-VDC @ 3.3 amp and P/S 2-20.28-VDC @ 3.6 amp. Maximal33F: P/S 1-10.0-VDC @ 5.3 amp P/S 2-10.0-VDC @ 5.3 amp or P/S 1-20.28-VDC @ 5.6 amp P/S 2-20.28-VDC @ 5.6 amp or P/S 1-10.0-VDC @ 5.3 amp and P/S 2-20.28-VDC @ 5.6 amp. Maximal55F: P/S 1-10.03-VDC @ 9.3 amp and P/S 2-10.03-VDC @ 9.3 amp. Maximal75F: P/S 1-10.03-VDC @ 9.3 amp and P/S 2-20.17-VDC @ 9.6 amp. Maximal77F: P/S 1-20.17-VDC @ 9.6 amp and P/S 2-20.17-VDC @ 9.6 amp. Fail-Safe [NC positive (+) & COM Negative (-)], Fail-Secure [NO positive (+) & COM Negative (-)], Auxiliary output [C positive (+) & COM Negative (-)] (When using AC power supplies polarity needs not to be observed), NC, C, NO convert to dry form C 5 amp 24VAC/VDC rated dry outputs when fuses are removed. Contacts shown in a non-triggered state. Fire Alarm Interface trigger input from FACP. Trigger inputs can be normally open, normally closed from an FACP signaling circuit output (Figs. 5-9, pg. 10). Form C relay contact rated @ 1 amp 28VDC for alarm reporting (not evaluated by UL). Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused) - 6 -

Power Supply Board Stand-by Battery Specifications: Battery Maximal11F Maximal33F Maximal55F, Maximal75F & Maximal77F 7AH 30 Mins./4 amp* 10 Mins./6 amp 5 Mins./10 amp 12AH 35 Mins./4 amp* 30 Mins./6 amp* 30 Mins./10 amp* 40AH Over 4 Hours/4 amp* Over 4 Hours/6 amp* Over 2 Hours/10 amp* 65AH Over 4 Hours/4 amp* Over 4 Hours/6 amp* Over 4 Hours/10 amp* *Only these configurations can be utilized in ULC-S319 installations. Fig. 1 OPEN --- 24V CLOSED --- 12V Power Supply Board Output Voltage Settings: Fig. 1a Switch Detail OPEN SWITCH CLOSED SWITCH --- DC + Fig. 2 Access Power Controller Typical Application Diagram (for each ACM8): ACCESS CONTROL PANEL OUTPUT RELAY C NO NC F1 IN GND 1 IN GND 2 NORMALLY OPEN N.O. DOOR RELEASING DEVICE IN GND IN GND 3 4 IN GND 5 IN GND 6 IN GND 7 IN GND 8 KEYPAD F2 F3 F4 F5 F6 F7 F8 SW5 FACP (Fire Alarm Control Panel) TRG J3 NO C NC + INP --- T + RET - + --- FACP INTERFACE Fig. 2a FACP Dry Form "C" Output NO C NC FACP SW1-SW8 FACP Interface Enabled LED1 SW1 SW2 SW3 SW4 SW6 SW7 SW8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 10A MAIN FACP Interface Disabled MAG. LOCK J2 J1 --- + Control OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 --- + Power ELECTRIC STRIKE ELECTROMAGNETIC DOOR HOLDERS UL Listed Power Supply For this application corresponding fuse F8 must be removed. This procedure makes the output a dry contact. MAG. LOCK J2 J1 Fig. 2b FACTORY WIRED TO EFLOW POWER SUPPLY POWER SUPPLY (Not evaluated by UL) - 7 - Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused)

5A 5A AC DELAY SHUTDOWN O N 1 min. 2 hr. enable TRIGGER EOL disable SUPERVISED AC DELAY SHUTDOWN O N 1 min. 2 hr. enable TRIGGER EOL disable SUPERVISED NO GND RESET NO GND RESET Fig. 3 Tamper Switch OPEN --- 24V CLOSED --- 12V Power Supply Board --- DC + --- BAT + AC1 AC FAIL BAT FAIL L G N NC C NO NC C NO AC DC + AUX Line Neutral OPEN --- 24V CLOSED --- 12V Wire Strap (from Enclosure to Door) Power Supply Board --- DC + --- BAT + AC1 AC FAIL BAT FAIL 120VAC Input 60 Hz. L G N NC C NO NC C NO Line Neutral Earth Ground AC DC + AUX CAUTION: When power supply board is set for 12VDC use only one (1) 12VDC stand-by battery. Connect red battery lead to the terminal marked [+ BAT] and to the [positive (+)] terminal of the battery. Connect black battery lead to terminal marked [BAT -- ] and to the [negative (--)] terminal of the battery. + BAT --- Optional Rechargeable Stand-by Battery for UL294 Applications. Note: 12V batteries required for Canadian installations. Optional Rechargeable Stand-by Battery for UL294 Applications Note: 12V batteries required for ULC-S319 installations. Optional Rechargeable Stand-by Battery for UL294 Applications Note: 12V batteries required for ULC-S319 installations. CAUTION: When power supply board is set for 12VDC use only one (1) 12VDC stand-by battery. Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. 12AH Rechargeable batteries are the largest batteries that can fit in this enclosure. A UL listed external battery enclosure must be used if using the 40AH or 65AH batteries. Sentrol model # 3012 Tamper Switch or equivalent (Not Included) Enclosure Edge of Enclosure Fig. 3a to Access Control Panel or U.L. Listed Reporting Device Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused) - 8 -

NEC Power-Limited Wiring Requirements: Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25 away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below. Your specific application may require different conduit knockouts to be used. Any conduit knockouts may be used. For power-limited applications use of conduit is optional. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute). Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring methods. For Canadian installations use shielded wiring for all connections. Note: Refer to wire handling drawing below for the proper way to install the CM or FPL jacketed wire, (Fig. 4a). Fig. 4 Supervisory Connections (power-limited) Optional UL Listed Battery Enclosure (non power-limited) Supervisory Connections (power-limited) Supervisory Connections (power-limited) Supervisory Connections (power-limited) 120VAC Input 60Hz (non power-limited) ACM8 outputs* Battery Connections (non power-limited) Fig. 4a Incorrect Wire Handling External Jacketed Shield Correct Wire Handling Supervisory Connections (power-limited) Wire Insulation Solid Copper Conductors Pull back external jacketed shield approx. 1/2. *Power-limited for Maximal11F. Non power-limited for Maximal33F, Maximal55F, Maximal75F and Maximal77F. - 9 - Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused)

FACP Hook-up Diagrams: Fig. 5 Optional hook-up using two (2) isolated power Fig. 6 Polarity reversal input from FACP signaling circuit supply inputs (Only applicable on Maximal11F) output (polarity is referenced in alarm condition): (Not evaluated by UL): CUT JUMPERS J1 AND J2 ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (ACM8 POWER) ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (LOCK POWER) CUT JUMPER J3 NO C NC FACP INTERFACE FACP SIGNAL CIRCUIT OUTPUT EOL -- FROM FACP SIGNAL OUTPUT + CIRCUIT Fig. 7 Normally Open - Non-Latching FACP Fig. 8 Normally Open FACP Latching trigger input trigger input: with reset: (This output has not been evaluated by UL) NO C NC FACP INTERFACE N.O. TRIGGER INPUT NO C NC N.O. TRIGGER INPUT JUMPER N.C. RESET SWITCH Fig. 9 Normally Closed - Non-Latching FACP trigger input: Fig. 10 Normally Closed - Latching FACP trigger input with reset: (This output has not been evaluated by UL) NO C NC FACP INTERFACE JUMPER N.C. DRY TRIGGER INPUT JUMPER N.C. RESET SWITCH N.C. TRIGGER INPUT Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused) - 10 -

Notes: - 11 - Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused)

Enclosure Dimensions (H x W x D approximate): 26 x 19 x 6.25 (660.4mm x 482.6mm x 158.75mm) 19 (482.6mm) 2 (50.8mm) 4 (101.6mm) 7 (177.8mm) 4 (101.6mm) 2 (50.8mm) TOP 6.25 (158.75mm) 1.25 (31.75mm) 0.85 (21.59mm) 8.9 (226.06mm) 19 (482.6mm) 8.4 (213.36mm) 0.85 (21.59mm) 1.25 (31.75mm) 1.5 (38.1mm) 1.5 (38.1mm) 1.5 (38.1mm) 8.5 (215.9mm) 5 (127mm) 1.25 (31.75mm) 7 (177.8mm) 7.5 (190.5mm) 7.5 (190.5mm) 26 (660.4mm) 26 (660.4mm) 8.5 (215.9mm) 26 (660.4mm) LEFT RIGHT 10 (254mm) 7 (177.8mm) 1 (25.4mm) 1 (25.4mm) 2 (50.8mm) 0.85 (21.59mm) 8.9 (226.06mm) 8.4 (213.36mm) 0.85 (21.59mm) 1.25 (31.75mm) BOTTOM 6.25 (158.75mm) 19 (482.6mm) 4 (101.6mm) 2 (50.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIMaximal11F/33F/55F/75F/77F Series F06N MEMBER Maximal11F/Maximal33F/Maximal55F/Maximal77F/Maximal75F Access Power Controllers (Fused) - 12 -