maxium smart Vac The innovative system for efficient smoke evacuation

Similar documents
maxium smart Vac The innovative system for efficient smoke evacuation

marvac The innovative system for efficient smoke evacuation

Examination Lights. marled E3. Latest-generation examination light

Ceiling support units. Independant. Flexible positioning and optimum utilization of space in the operating room and intensive care unit

marled Operating Lights

BUILD the clinic you ve always imagined.

UNITS /2017-E S-PILOT. The solution for smoke evacuation

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

STAUFF STAUFF. Local solutions for individual customers worldwide. Laser Particle Monitor - LPM 1 FILTRATION TECHNOLOGY

Megadyne. MEGADYNE Smoke Evacuation Portfolio for eff icient removal of surgical smoke

STAUFF STAUFF. Local solutions for individual customers worldwide. Laser Particle Monitor - LPM 1 FILTRATION TECHNOLOGY

Beckhoff short profile

The new mains-operated ATMOS respiratory tract suction devices in the reliable 26 l and 16 l class

Drying and heating chambers

STT 3000 Series STT250 /150 Surge Protection Device Specifications

SHAKING WATER BATHS ENGLISH

DIAPHRAGM VACUUM PUMPS

SYSTEMS PRODUCT OVERVIEW

Powerful universal suction devices for gynaecology and obstetrics. ATMOS S 351 Natal ATMOS C 451

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH HYDROPHOBIC VALVE

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

MTL1000 range of signal conditioners. For reliable, high quality process communications

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

Intelligent. Powerful.

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

PROCESS AUTOMATION PEPPERL+FUCHS BEBCO EPS 6000 SERIES PURGE AND PRESSURIZATION SYSTEM

Vacuum Interrupters. Outstanding vacuum-related manufacturing techniques of MEIDEN has

CO₂ incubators. C CB series

MEDIST s.r.o., Petrusovskeho 4, Humenne, Slovakia Tel.: , Fax: ,

PCMini52 Digital RH & Temperature Mini Probe User s Manual

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

DIAPHRAGM VACUUM PUMP LABOPORT N FT.18

Free swing slide-channel door closer TS 99 DORMA. in Contur Design

Getinge WD14 Tablo Tabletop washer-disinfector. Fast and with high-throughput

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 04

Operator s Manual AER DEFENSE TM

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Drying and heating chambers. Series ED FD FED FP M

HERAEUS HERASAFE KS SAFETY CABINET CLASS II. Safety. Everything you need more than you expect

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Dräger P4000 Pressure and Leak Testing

AZTECA A LITRE STERILISER

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

DIAPHRAGM VACUUM PUMPS FOR AUTOCLAVES

The right temperature worldwide. Chapter Proline. LAUDA the big one. Thermostats, Circulation chillers, Water baths

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

Ultra low temperature freezers

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

CO₂ incubators. C CB series

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

The Ottawa Hospital OPERATING ROOM NURSING POLICY, PROCEDURE, PROTOCOL MANUAL

Dental instrument Washer Disinfectors

Dräger Pac 5500 Single-Gas Detection Device

Dräger Pac 7000 Single-Gas Detection Device

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Dräger Pac 8500 Single-Gas Detection Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Safety requirement compliance for Lasers

Varistar LHX 3 Air/Water Heat Exchangers

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

COOL COMBINATION EQUIPMENT PROTECTION SOLUTIONS INDUSTRIAL ENVIRONMENTS

Multi-User Vacuum Systems for up to ten Users LABOBASE

ADVANCED PORTABLE SUCTION A STERIS Company

Tropic 2.0 ultrasonic nebuliser

ACCUVAC Lite. Simply Strong Suction Made Easy

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH MECHANICAL VALVE

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger X-am 5000 Multi-Gas Detection

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

SINGLE USE INSTRUMENTS

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

EZPlus Fully Automatic Sterilizers

Relationship between Air Volume and Particle Removal No. of 0.5 μm particles (per L) 800 Air volume 1 0.3m 3 /min 600

Dräger X-am 2500 Multi-Gas Detection

GLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled

HEALTHCARE GET AHEAD IN LAUNDRY

beta.line modular technology and services

FieldLink Cable solutions for Automation & Drives

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

~äéü~käáåé= FIRST CHOICE FOR SMALL AND MEDIUM FORMATS. íéåüåçäçöó=~åç ëéêîáåéë. ~äéü~kñ dampening solution filtration ~äéü~kê water preperation

THE GATES TB. ValveGate TM Mini-Thoracotomy Retractor with straight arms, 30x60mm blades with turnable crossbar (detachable) for accessories*

Dräger Polytron 7000 Fixed gas detector

Designers Manual. Haldex Single Air Drier

Arc Fault Protection System D1000

Weller. Zero-Smog Filter Systems. Tip Extraction. Volume Extraction

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems

Fume Extraction Solutions. We care for your working environment.

Dräger QuadGard Control System

For more information on Tarkett go to

LOGIC CONTROLLED DEKO 25 EASE OF USE

AVAILABILITY EASE OF INSTALLATION SERVICE. SpectraCool Slim Fit Air Conditioner. Easy to Specify and Ready to Use

NT 35/1 Tact Te. Tact system (Tact Automatic Filter Cleaning System) Ideal connections. High-quality, robust equipment.

Dräger Pac 6000 Single-Gas Detection Device

Transcription:

maxium smart Vac The innovative system for efficient smoke evacuation www.klsmartin.com

Enhanced visibility and maximum safety at the operating site surgical smoke is a trouble of the past!

maxium smart Vac: innovative and efficient maxium smart Vac Enhanced visibility and maximum safety at the operating site surgical smoke is a trouble of the past! KLS Martin has a huge expertise in laser- and electrosurgery. With the innovative smoke evacuation system maxium smart Vac, KLS Martin is setting a new standard in the evacuation of surgical smoke. In the recent years the demand for devices with the possibility to extract the smoke directly from the OR field has grown. The smoke evacuator maxium smart Vac in combination with our innovative high-frequency generators are reliable partners in your operating theater. Convince yourself! The advantages at a glance Simultaneous evacuation to high-frequency activation Individual parameters can be memorized in the user program of the maxium Extended filter-capacity due to special filter technology Two suction hoses can be connected, each individually or simultaneously TURBO mode LAP mode Obstruction control Connection to central suction device possible 3

maxium smart Vac: innovative and efficient maxium smart Vac Easy selection and adjustment of parameters The smoke evacuator maxium smart Vac offers reliable protection from particles, viruses, gases and carcinogenic substances capable of invading the lung. When used in automatic mode, the smoke evacuator is only active when needed, triggered by HF- or laser activation. LAP mode* TURBO mode Start/Stop mode (manually) Active suction/ delay active suction Standby suction Modification of parameters (up and down pushbuttons) 4

TURBO Mode Huge quantity of smoke can be eliminated effectively from the OR field. LAP Mode* Specially designed for laparoscopic procedures; suction parameters will be automatically limited and the reflux of gas will be reduced to a minimum. START/STOP Alternatively, the smoke evacuator can also be activated manually. Active suction / standby suction Active suction, stand-by suction and delay time can be selected as required before and during the surgical procedure. These parameters can be easily adjusted by pressing the up and down buttons. Modification of parameters (up and down pushbuttons) * only when ordering maxium smart Vac with LAP mode 5

maxium smart Vac: cost efficient and reliable maxium smart Vac Changeable main filter unit The specially designed filter system which corresponds to ULPA* standard provides safe and effective protection in the operating theater. The large inner-filter-surface provides a long-lasting lifetime. The main filter unit provides two different connections. Suction tubes with Ø 22 mm as well as with Ø 10 mm can be connected individually or simultaneously. The filter status will be measured permanently and shown on the indicator. A required filter change will be displayed by the smoke evacuation system, early in advance. If required, the smoke evacuator can be connected to a central-or-suction system. This optional feature can be ordered on request. * ULPA = Ultra Low Penetration Air 6

maxium smart Vac maxium maxium smart Cart The HF generator as well as the smoke evacuation system can be positioned on a specially designed trolley. Alternatively, the system can be placed on a pendant. User-friendly set-up of parameters via MCB (=Martin-Communication-Bus) The parameters for the maxium smart Vac can be selected and adjusted through the HF generator maxium and memorized in the user-program.* * Please consider that maxium HW06 and software V3.398 are required. 7

Accessories for smoke evacuation system maxium smart Vac High Efficiency Surgical smoke can be extracted directly from the surgical site, where it is created. KLS Martin offers a wide range of accessories for the elimination of surgical smoke created from electrosurgery or medical laser systems. Various clip-on attachments offer in combination with the smoke evacuation system maxium smart Vac reliable protection from surgical smoke. 80-060-03-04 (Packaging unit = 12 pieces) Electrode handle with electrode Ø 2.4 mm, with attached clip-on applicator, sterile, flexible tubing length = 3 m, suction hose connection Ø = 22 mm Moreover KLS Martin provides a solution where a disposable clip-on applicator can be attached to a reusable electrode handle. 80-060-02-04 (Packaging unit = 12 pieces) Clip-on applicator, sterile, flexible tubing length = 3 m, suction hose connection Ø = 22 mm, attachable for KLS Martin electrode handles 80-217-xx-04, 80-210-12-04* 8 * Electrode-handle needs to be ordered separately. Please find more accessories on page 10.

smartlap Electrodes with smoke evacuation for laparoscopy Premium quality working tips L-hook J-hook Needle smartlap electrodes Overview Item. No. Description 83-525-30-04 smartlap electrode, Ø 5 mm, L-hook 83-525-31-04 smartlap electrode, Ø 5 mm, J-hook 83-525-32-04 smartlap electrode, Ø 5 mm, needle-tip Accessories 80-060-04-04 Single-use tubing for smoke evacuation, Ø 10 mm, with Luer-lock connector 83-120-51-04 Connector cord, monopolar, Ø 4 mm, 3-pin 9

maxium smart Vac at a glance Ordering information for smoke evacuation system maxium smart Vac and accessories Item No. Product description 80-062-00-04 Smoke evacuation system maxium smart Vac with LAP-Mode, 220 V incl. main filter unit (item 80-060-01-04) 80-062-00-10 Smoke evacuation system maxium smart Vac with LAP-Mode, 100 V incl. main filter unit (item 80-060-01-04) 80-062-01-04 Smoke evacuation system maxium smart Vac, 220 V incl. main filter unit (item 80-060-01-04) 80-062-01-10 Smoke evacuation system maxium smart Vac, 100 V incl. main filter unit (item 80-060-01-04) Item No. Individual components 80-060-01-04 Main filter unit for smoke evacuator maxium smart Vac (ULPA standard) 80-811-50-04 Single-pedal foot switch for manual activation 80-060-06-04 Adapter for connection to a central suction (Ø 22 mm) Item No. Connection options for automatic operation (HF generator or laser) 80-091-01-04 MCB connection cable (maxium and maxium smart Vac) 80-060-05-04 Adapter for mains current detection 76-100-60-04 Extension cable for smoke evacuation with laser 80-091-02-04 Connection cable ME MB2/3 with maxium smart Vac 79-800-02-04 Interlink cable to Limax 60/diomax 980/1550 Item No. Accessories and consumables 80-060-02-04 Clip-on applicator, sterile, disposable, flexible tube length 3 m, Ø 22 mm for reusable electrode handles KLS Martin 80-217-xx-04 and 80-210-12-04 (packaging unit = 12 pieces) 80-060-03-04 Clip-on and electrode handle, Ø 2.4 mm, sterile, disposable, flexible tube length 3 m, Ø 22 mm (packaging unit = 12 pieces) 80-060-04-04 Air hose, sterile, Ø 10 mm with Luer-Lock connection, 2.5 m long, (e.g. for connection of trocar) (packaging unit = 20 pieces) 79-225-02-04 Funnel, flattened on one side, with Ø 22 mm connection, can be autoclaved 50 times at max. 134 C (273 F) 79-225-03-04 Plastic suction tube with cone connection for suction hose Ø 22 mm, can be autoclaved 50 times at max. 134 C (273 F) 79-225-06-04 Hose connector, straight, Ø 22 mm (female) to Ø 10 mm (male); can be autoclaved 50 times at max. 134 C (273 F) 79-225-07-04 Hose connector, straight, Ø 22 mm (female) to Ø 22 mm (male); can be autoclaved 50 times at max. 134 C (273 F) 79-225-08-04 Air hose Ø 22 mm, 3.0 m long, multi-use; can be autoclaved 50 times at max. 134 C (273 F) 79-225-09-04 Air hose Ø 10 mm, 2.0 m long, multi-use; can be autoclaved 50 times at max. 134 C (273 F) 79-225-10-04 Suction hose, sterile, Ø 22 mm, single-use (packaging unit = 25 pieces) 79-225-11-04 Prefilter (HEPA standard), Ø 22 mm, sterile, single-use (packaging unit = 20 pieces) 10

Technical specifications Power supply 100-240 V ± 10%; 50/60 Hz Appliance air flow > 750 l/min Power input < 500 W / 740 VA Activation Automatic activation, front-panel button, optionally by foot switch Mains current detection (adapter) Interfaces Foot switch, MCB (Martin Communication Bus), USB Protection class I Classification acc. to MDD IIa Type of applied part CF; defibrillation-proof Main filter ULPA efficient 99.9995% @ 0.1-0.2 μm for tube size Ø 22 mm and Ø 10 mm Filter lifetime 40 hours. Filter change will be indicated at the unit. Weight Smoke evacuation system maxium smart Vac, 220-240 V, 10.6 kg Smoke evacuation system maxium smart Vac with LAP mode, 220-240 V, 11.6 kg Smoke evacuation system maxium smart Vac, 100 V / 110 V / 120 V / 127 V, 12.6 kg Smoke evacuation system maxium smart Vac with LAP mode, 100 V / 110 V / 120 V / 127 V, 13.6 kg EMI Keeps limits according to EN 55011 and IEC 60601-1-2 Immunity according to IEC 801 Dimensions Width 390 mm Height 218 mm Depth 460 mm (with main filter) Environmental conditions for Ambient temperature -25 C to +70 C (-13 F to 158 F) transportation and storage Relative humidity 10% to 100% Atmospheric pressure 500 hpa to 1060 hpa Environmental conditions for operation Ambient temperature +10 C to +40 C (+50 F to 104 F) Relative humidity 30% to 75% Atmospheric pressure 700 hpa to 1060 hpa CE-marking: conform with 93/42/EEC Classified acc. to MDD (Medical Device Directive) IIa 11

KLS Martin Group KLS Martin Australia Pty Ltd. Sydney Australia Tel. +61 2 9439 5316 australia@klsmartin.com KLS Martin do Brasil Ltda. São Paulo Brazil Tel. +55 11 3554 2299 brazil@klsmartin.com KLS Martin Medical (Shanghai) International Trading Co., Ltd. Shanghai China Tel. +86 21 5820 6251 china@klsmartin.com KLS Martin India Pvt Ltd. Chennai India Tel. +91 44 66 442 300 india@klsmartin.com Martin Italia S.r.l. Milan Italy Tel. +39 039 605 67 31 italia@klsmartin.com Nippon Martin K.K. Tokyo Japan Tel. +81 3 3814 1431 nippon@klsmartin.com KLS Martin SE Asia Sdn. Bhd. Penang Malaysia Tel. +604 505 7838 malaysia@klsmartin.com Martin Nederland/Marned B.V. Huizen The Netherlands Tel. +31 35 523 45 38 nederland@klsmartin.com Gebrüder Martin GmbH & Co. KG Moscow Russia Tel. +7 499 792-76-19 russia@klsmartin.com Gebrüder Martin GmbH & Co. KG Dubai United Arab Emirates Tel. +971 4 454 16 55 middleeast@klsmartin.com KLS Martin UK Ltd. London United Kingdom Tel. +44 1189 000 570 uk@klsmartin.com KLS Martin LP Jacksonville Florida, USA Tel. +1 904 641 77 46 usa@klsmartin.com Do you know how to get all important information about the KLS Martin Energy Devices? Please download KLS Martin App Energy Devices! The App is available for Android and ios. https://itunes.apple.com/de/app/ kls-martin-energy-devices/id1198171415?l=de&ls=1&mt=8 https://play.google.com/store/apps/ details?id=com.klsmartin.energydevices Gebrüder Martin GmbH & Co. KG A company of the KLS Martin Group KLS Martin Platz 1 78532 Tuttlingen Germany P.O. Box 60 78501 Tuttlingen Germany Tel. +49 7461 706-0 Fax +49 7461 706-193 info@klsmartin.com www.klsmartin.com 06.18 90-228-02-05 Printed in Germany Copyright by Gebrüder Martin GmbH & Co. KG Alle Rechte vorbehalten Technische Änderungen vorbehalten We reserve the right to make alterations Cambios técnicos reservados Sous réserve de modifications techniques Ci riserviamo il diritto di modifiche tecniche 12