Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

Similar documents
Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Glenside Environmental Services Ltd

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

This document is a preview generated by EVS

Rol van ISSeP als sectoraal operator

Complete Gas Analysis

MANUFACTURER OF POLLUTION CONTROL SYSTEMS

GUIDELINES FOR DESCRIBING THE ACCREDITATION SCOPES OF TESTING LABORATORIES

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Technical manual 2G-TA 04 - Gas

This document is a preview generated by EVS

Chemistry Instrumental Analysis Lecture 29. Chem 4631

ACTIVITIES OF THE MEASURING GROUP

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Airborne Hazard Emergency Response

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Wet ElectroStatic Precipitator

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

Ministerial Decree No. 14/2005 (VI. 28.) KvVM. on the rules concerning the screening surveys of remedial site investigations.

INTERNATIONAL STANDARD

Thermo Scientific TVA2020 Introduction

The Laboratory is qualified to update standards identifying the test procedures.

The Laboratory is qualified to update standards identifying the test procedures.

TEST REPORT Page 1 of 28. Uçar Oyuncak San.ve Tic.Ltd.Şti.

Meeting NFPA standards for

Monitoring Flammable Vapors and Gases in Industrial Processes

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

portable gas analyser

Xgard. Fixed detectors For flammable, toxic or oxygen gases

English Version. This Technical Specification (CEN/TS) was approved by CEN on 25 October 2009 for provisional application.

INTERNATIONAL STANDARD

PRODUCT CONFORMITY CERTIFICATE

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Real-time Monitoring Technology for Preservation Environment of Archives

Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Industrial Grade Gas Detection Detecting The Difference

Title. Author(s)Yoshida, Fumikazu; Yoshida, Haruyo. Issue Date Doc URL. Type. File Information

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

CZ-CPA code CSNEN CPNBÚ CSNEN ISO/IEC 17067:2014 scheme la, lb, 5 CP NBÚ CSNEN ISO/IEC 17067:2014 scheme 3 CPNBÚ

BULGARIAN ACCREDITATION SERVICES ACCREDITED ACCORDING TO BDS EN/ISO 17020:2005

portable gas analyser

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

The Appendix is an integral part of Certificate of Accreditation No. 104/2015 of

HFID Heated Total Hydrocarbon Analyzer Module

Automatic Isokinetic Sampler ST5

incontrol Systems Inc. Flame and Gas Detection

Annex to the Accreditation Certificate D-ZE according to DIN EN ISO/IEC 17065:2013

CONTENTS. Abstract. Abstrak. Acknowledgement. List of Figures. List of Tables. List of Symbols and Abbreviations CHAPTER 1.

Ambient air quality monitoring

DIRECTIVE 98/34/EC REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC.

Energy recovery from exhaust gases using Heat Pipe technology

Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

National foreword. Text affected

3M Oldham OLCT 100. Description. Fixed Gas Detector

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines

Recent Improvements in Process GC Instrumentation

Sensor Suite Sensors. Sensor Suite Sensors: Overview. Ordering Guide. Overview FEATURES

CERTIFICATE of Product Conformity (QAL1 )

with plasma ioniser and Remote Control USER MANUAL

This document is a preview generated by EVS

A comparison of emerging gamma detector technologies for airborne. radiation monitoring

LFL Monitoring. MEGTEC Systems

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

RENAR Accreditation Activities

Sýnishorn Ventilation in hospitals - Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

PERFORMANCE EVALUATION OF DIFFERENT GREEN ROOF DESIGNS CHENGDU, CHINA

Fire Protection Scover

Iesf Report l't March 2010

Duct Air Quality Sensors

Air-Quality Detection Module. User s Manual

Structural Fires: Selected Guidance from NYS Department of Health

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Smoke detection in hazardous areas:

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS ( MARPOL reg VI/15 )

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Footwear Test methods for uppers and lining Water vapour permeability and absorption

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

DIRECTIVE 98/34/EC REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES BY MEMBERS OF CENELEC

Declaration of Compliance BS3882:2015

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Air Purification Systems. Clearing the Air. Air Purification Systems. Air Purification Systems

Transcription:

Page 1 of 7 All tests and sampling performed by the laboratory meet the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009. The Laboratory is qualified to update standards identifying the test procedures. The laboratory is qualified to provide opinions and to interpret the test results. Tests: 1 Determination of mass concentration of particulate matter in emissions by gravimetry 2a* Determination of mass by NDIR method (NO and NO 2 ) (SO 2 ) (CO) (CO 2 ) (NO,NO 2,SO 2,CO 2,CO,O 2 ) 2b* Determination of mass by chemiluminescence method (NO and NO 2 ) 2c* Determination of mass by FID method (TOC) IP 100 (ISO 9096, ČSN EN 13284-1) IP 200a ČSN ISO 10 849, ČSN ISO 7935, ČSN EN 15058, IP 200b ČSN EN 14792, IP 200c ČSN EN 13526, ČSN EN 12619, Emission

Page 2 of 7 2d* Determination of mass by paramagnetic method (O 2 ) 2e* Determination of mass by electrochemical method (NO,NO 2, CO,O 2 ) 2f* Determination of volume concentration of CO 2 by balance calculation from element analysis and amount of burned fuel 3a* Determination of the velocity and volume flow rate 3b* Determination of volume flowrate by balance calculation from element analysis and amount of burned fuel IP 200d ČSN EN 14789, IP 200e (ČSN EN 50379-1, ČSN EN 50379-2, IP 200f (OTN ŽP 2008) IP 300a (ČSN ISO 10780, ČSN EN ISO 16911-1 IP 300b (OTN ŽP 2008) 3c* Determination of water vapour in ducts by condensationabsorption, condensation and electrical capacitance method 4 Reserved IP 300c (ČSN EN 14790)

Page 3 of 7 5 Determination of the mass concentration of gases and vapours taken into liquid by the calculation from measured values** (SO 2 ) (HCl) (HF) (Ammonia) (Sulfane) (Cl 2 ) (HCN) (HCOOH, CH 3 COOH) (total reduced sulphur - TRS) 6 Determination of the mass concentration of metals by the calculation from measured values** (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (Hg) (Cr 6+ ) (Be, Se, Zn, Sn, Te) 7 Determination of mass concentration of persistent organic compounds by the calculation from measured values** (PCDD/PCDF, PCB) (PAH) IP 500 (ČSN EN 14791, ISO 7934, ČSN EN 1911, ČSN 834752, ISO 15713, ČSN 834728, ČSN 834712, EPA CTM 33, STN 834735, EPA Met. 16A) IP 600 (ČSN EN 14385, ČSN EN 13211, EMEP p. 3. 12, EPA Met. 0061, EPA Met. 29) IP700 (ČSN EN 1948-1, ČSN EN 1948-4+A1 ISO 11338) 8 Determination of mass IP 800

Page 4 of 7 concentration of volatile organic compounds (VOC) by capture on solid sorbent by calculation from measured values** 9 Reserved 10 Determination of concentration of odour substances by dynamic olfactometry 11* Demonstration of quality of automated measuring systems 12 Reserved 13* Measurement of operating efficiency of 2nd stage petrol vapour recovery system by "wet method" B 14-20 Reserved 21* Determination of mass concentration of airborne dust TSD, PM10 fraction and PM2.5 fraction** (ČSN P CEN/TS 13649, ČSN EN ISO 16017-1, EPA Met. 0011) IP 1000 (ČSN EN 13725) IP 1100 (ČSN EN 14181, p.6 QAL2, p.8 AST) IP 1300 (DIN EN 16321-2) IP2100 (ČSN EN ISO 13137, ČSN EN ISO 16000-1, ČSN EN 481 ČSN ISO 7708, Govenrment Regulation No. 361/2007 Coll., Annex No. 3 ČHMÚ 1997 MP 11 ČSN EN 12341) Automated emission measuring systems Petrol vapours Outdoor and indoor air, occupational environment #, immission * Asterisk at the ordinal number identifies the tests performed outside the laboratory premises. ** Two asterisks at the test procedure name indicate that the laboratory determination of an analyte in the # sample is subcontracted to an accredited testing laboratory. Cross at the standard indicates that this standard applies to gas turbines only. occupational environment except the measurement for work categorisation purposes

Page 5 of 7 Sampling: number Sampling procedure name 1 Sampling of solid pollutants in emissions (Isokinetic sampling with automatic or manual isokinetic control) 2 4 Reserved 5 Sampling of gases and vapours by absorption of liquids (non-isokinetic and isokinetic sampling with automatic or manual isokinetic control) (SO 2 ) (HCl) (HF) (Ammonia) (Sulfane) (Cl 2 ) (HCN) (HCOOH, CH 3 COOH) (total reduced sulphur - TRS) 6 Sampling of metals by condensation-absorption method (isokinetic sampling with automatic or manual isokinetic control) (As,Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (Hg) (Cr 6+ ) Sampling procedure identification IP 100, chapter 7 (ISO 9096, ČSN EN 13284-1) IP 500, chapter 7 (ČSN EN 14791, ISO 7934, ČSN EN 1911, ČSN 834752, ISO 15713, ČSN 834728, ČSN 834712, EPA CTM 33, STN 834735, EPA Met. 16A) IP 600, chapter 7 (ČSN EN 14385, ČSN EN 13211, EMEP p. 3.12, Sampled object

Page 6 of 7 number Sampling procedure name Sampling procedure identification (Be, Se, Zn, Te, Sn) EPA Met. 0061, EPA Met.29) Sampled object 7 Sampling of persistent organic compounds by dilution method (Isokinetic sampling with automatic or manual isokinetic control) (PCDD/PCDF, PCB) (PAH) 8 Sampling of volatile organic compounds (VOC) by capture on a solid sorbent 9 Reserved 10 Sampling of odour substances 11-20 Reserved 21 Sampling for the determination of mass concentration of airborne dust TSD, PM10 fraction and PM2.5 fraction** IP 700, chapter 7 (ČSN EN 1948-1, ČSN EN 1948 4+A1, ISO 11338-1) IP 800, chapter 7 (ČSN P CEN/TS 13649, ČSN EN ISO 16017-1, EPA Met. 0011) IP 1000, chapter 7 (ČSN EN 13725) IP2100, chapter 6 (ČSN EN ISO 13137, ČSN EN ISO 16000-1, ČSN EN 481 ČSN ISO 7708, Government Regulation No. 361/2007 Coll., Annex No. 3 ČHMÚ 1997 MP 11 ČSN EN 12341) Outdoor and indoor air, occupational environment #, immission

Page 7 of 7 Explanations and abbreviations: IP internal regulation NDIR Nondispersive Infrared Spectrometry FID Flame Ionization Detection TSD Total Suspended Dust VOC Volatile Organic Compounds TOC Total Organic Carbon PCDD/PCDF Polychlorinated Dibenzodioxins/Polychlorinated Dibenzofurans PCB Polychlorinated Biphenyls PAH Polycyclic Aromatic Hydrocarbons EMEP Sampling and Chemical Analysis Manual (European Monitoring and Evaluation Programme) Emission waste gas containing pollutants, which is released in a controlled way or leaks into atmosphere from air pollution sources air STN Slovak Technical Standard ČSN Czech Technical Standard EPA U.S. Environmental protection agency DIN Deutsches Institut für Normung OTN ŽP Branch technical standard of MoE SR ISO International Organization for Standardization EN European Standards (CEN - European Committee for Standardization) TESO Registered trademark of Technické služby ochrany ovzduší