Operating and assembly manual: Electric instantaneous flow heater Admiral

Similar documents
ELECTRIC WATER HEATER HT382E55

Tankless Electric Water Heater MS-C2PSU Series

CONTENTS. Important Safety Instructions page 2

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

SEIH7KTS1,SEIH9KTS1 SEIH11KTS1. Installation Manual. Issue STROM- ELECTRICAL.

KOSPEL S.A KOSZALIN UL. OLCHOWA 1

Flow Factor ~

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

Installation Manual SEIHTP1, SEIHTM1. Issue SEIHTM1 Model Shown STROM- LIMITED.

INSTALLATION AND OPERATION MANUAL

This manual provides many important safety points. Please read it carefully and follow the instruction rules.

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

VADA - Rain2Main Automatic Rainwater Controller

Instantaneous water heater - Operation and installation instructions

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

TH100 Three in One Instant Hot Water Tap

V80-H Multistage Pump Instruction Manual

EH0533 Indoor Climate Control

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01

EH0554 Indoor Climate Control

Unvented Electric Water Heater 10/15 litre Undersink

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Zen Boiling Tap Range

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

SCHWAN INSTALLATION GUIDE

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

TECHNICAL PROPERTIES OF THE APPLIANCE

Air-Water heat pump Small GT

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

Installation and Operation Guide

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

INSTANT HOT WATER DISPENSER

Congratulations! You've just purchased a new Santon tankless water heater and will soon begin to enjoy the benefits of going tankless.

O Pro electric storage water heater

DHC-E TANKLESS ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER AND ELECTRICIAN

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

OPERATION AND INSTALLATION

Installation and Operation Guide

Installation & Operating Guide

SAVE THESE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

A few simple steps to ensure perfect water, every time.

SP16. 08/50740/1 (UK) - Issue 1

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

QUICK START GUIDE 04 WARNING 05 PACK CONTENTS 05 TECHNICAL SPECIFICATIONS 05 ELECTRICAL REQUIREMENTS 05 WIRING DIAGRAM 07 INSTALLATION OPTIONS

PANTHER. Condensate removal pump Installation and operating guide

A few simple steps to ensure perfect water, every time.

Convection Panel Heater

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

Instructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

HW3 Handwash Installation and Operating Instructions

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - HW

INSTALLATION & TECHNICAL MANUAL

INSTRUCTION MANUAL Water Dispenser

INSTANTANEOUS ELECTRIC SHOWER

Dene Bath Shower Mixer

SCHWAN INSTALLATION GUIDE

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

PURE 7.5/8.5/9.5/10.5kW

AMBION FLAME. INSTALLATION AND USER INSTRUCTIONS

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. User Guide W5-A

OPERATING AND INSTALLATION MANUAL

Flomate Mains Boost Pump Installation & Maintenance Instructions

Removing shipping locks

Mira Sport Max with Airboost

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

OPERATING AND INSTALLATION MANUAL

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Installation and Operation Guide

Electronically controlled instantaneous water heater

Installation & Operating Guide

Inverter Swimming Pool Heat Pump

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel Fax

Akva Vita Instantaneous water heater

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

INSTALLATION & TECHNICAL MANUAL

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Instructions for the fan motor control system, SILVER C

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Bath Shower Mixer

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

INSTALLATION INSTRUCTIONS

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

INSTALLATION INSTRUCTIONS WARRANTY

Transcription:

Operating and assembly manual: Electric instantaneous flow heater Admiral (build in AsC and AsC-W electric heating boilers or sold separately) Available power: 7,5kW; 12kW; 15kW; 18kW; 21kW 1

Please read this manual prior installation and use of purchased product. Efficiency of every flow heater is mentioned in technical data table. Using unit with insufficient power compared to hot water requirement will result in too low output temperature. Do not turn flow heater on in case of suspicion, that it may contain frozen water! Instantaneous flow heater Admiral requires permanent connection to electrical network, installation itself should be done by qualified electrician (in accordance with manual). Flow heater cannot be connected to electrical installation using electric plug. Safety instructions: 1. The installation of this Admiral appliance set must be in compliance with the National Electrical Code, as well as your local electrical and plumbing codes. 2. The unit must be properly earthed in accordance with all current regulations and laws. 3. Flow heater has to be connected and used in accordance with this manual. 4. All wiring and installation must be supervised by a qualified and trained electrician. 5. This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 6. This appliance must be permanently connected to the fixed circuit breaker and it must be installed vertically. Do not install this appliance near to tinder or strong magnetic field place. 7. Keep the flow heater off when exposed to freezing, do not install this unit in below zero C conditions. 8. Please test the outlet hot water temperature with your hand to make sure it is suitable for showering before doing so. 9. The heating chamber is treated with composite nano insulation material; it is natural if there might be a bit of smell or green blue smoke when the unit is used for the first time. 10. In case of cable/wire damage you must contact qualified electrician to replace it with a new wire(s). 11. Please flush the system through completely by opening the hot tap on the water heater circuit furthest away from the heater. Allow all air and debris to pass before closing the hot tap. 12. Before the installation please make sure that water flow is present, only then connect the power supply. The heater cannot be activated without water supply, otherwise damage may occur. 13. Opening external casing of this flow heater may result in electric shock. 14. Lack of mesh filter on supply side may cause damage and may void the warranty. 15. This water heater may cause small amount of water expansion due to residual heat after operation. In most systems this is easily accommodated by the distribution pipework and water supply system 2

Warranty doesn't cover mechanical damages being installers' fault, as well as poor water quality (np. sedimentation, high water hardness, etc.). Safety features in Admiral: Against water leakage Against overheating Build-in safety pressure valve Heater protection - no operation when lack of water Product description: Electric instantaneous flow heater Admiral is a device, which heats domestic hot water in flow manner. That is the most efficient way to obtain domestic hot water in faucet, sink or shower. Water is not preheated and stored, but heated directly when needed. As a consequence, no energy is lost in the process. Admiral has state-of-the-art, patented heat exchanger, solution which eliminates scale deposition most common issue with standard flow devices with build-in heaters. Water is completely separated from live components, what ensures high durability and 100% safety. Use: Electric instantaneous flow heater Admiral can be used to obtain domestic hot water in sink or shower. 3

Device schematics: 1. Thermic switch 2. Reset (of thermic switch) 3. Heat block 4. Temperature sensor 5. Flowmeter 6. Triac 7. Connecting block 8. Thermic safety fuse 9. Hot water outlet 10. Cold water inlet Electric schematics: Device installation - remarks: The installation must only be carried out by qualified installer and installed in accordance to all national and local electrical and plumbing regulations. 1. Make sure the device is not mechanically damaged and complete. 2. Do not install in premises where temperature falls below 0 C. 3. Compare your installation with device requirement (power allocation, supply voltage, water pressure, earth, wires cross section, proper fuses both over-current and differential-current, etc.). 4. Device needs to be earthed! 5. Main power circuit needs to be protected both over-current and differential-current fuses. 6. Do not install close to strong magnetic field. 7. In case of longer idle time of device, power supply needs to be disconnected. 8. We highly recommend fitting an isolation valve and ball valve before the unit to close system before removal of the tap and servicing. 4

Installation step-by-step: 1. Front and back sides of the unit. 2. Remove screws which fixed the bracket on back of the heating unit. 3. Hold the back bracket hanger in position against the wall and mark three mounting holes. Drill three holes of 6.00mm diameter, the distance between every two holes is 100mm. (Put plastic anchor in the hole, fix the bracket on the wall and secure the hanger using the screws supplied or an appropriate alternative method). 4. Uninstall screws on appliance to remove the front cover, please use hand to pull out the screen row line plug carefully before removing the front cover. Once your product has been fixed in accordance with the diagrams above please connect your product to the mains water supply using a 1/2" tap pipes to the blue connection of the unit. Flow heater Admiral 7,5 kw (single phase) has power cord taken out enabling to connect device without removing external casing! Flow heaters supplied with 400 V~ do not have power cord taken out. Connection to be made directly to connecting block inside device. The hole for inserting power cord is placed on the bottom side! Electrical works: 1. The installation must only be carried out by qualified electrician in accordance with all regulations. 2. The unit must be properly earthed and proper fuses need to be installed. 3. While connecting device, main electrical switch needs to be turned off (on electrical switchboard). 5

Water connection: Water connection need to be performed using elastic hoses with gasket. Do not use teflon or oakum for that purpose. Please pay special attention while making water connection, rotating or breaking connection may cause irreparable damage to the device. 1. All water pipes and other accessories must be in accordance with all current regulations and laws. 2. Device has to be connected vertically (connections from bottom side). Horizontal placement is forbidden. Blue connection is for cold water inlet, red one for hot water outlet. 3. Flush the system through completely by opening the hot tap on the water heater circuit furthest away from the heater. Allow all air and debris to pass before closing the hot tap. 4. Remember to use rubber gaskets on water connections. 5. On cold water inlet, rubber gasket should be equipped with mesh net. All connections need to be checked for tightness. Use: Flow heater starts operation when water flow sensor detects demand for hot water (eg. starting a shower) only then device turns on and starts to consume electrical energy). Device is turned off instantly when demand for hot water stops. It is possible to set required water temperature level, what additionally reduces total energy consumption. Flow heaters are equipped in overheating safety feature. When water temperature exceeds 67 C (7,5 kw) and 72 C (12-21 kw) device will enter into pause mode in order to avoid scales deposition. It will be indicated by "E1" shown on display. Device will return to standard mode after temperature cools down to 58 C. Automatics also monitors current loss, which when detected is indicated by "E2" shown on display. "E3" is shown when temperature sensor has been damaged. Admiral also protects build-in heating element from overheating electric supply is turned off when heating element temperature reaches 95 C (7,5 kw) and 90 C (12-21 kw). In case this protective system is activated, one should remove external case and press RESET button. Control: 1. Open the water faucet for a few minutes until water flow is continuous and all air is purged from water pipes, after turning water off turn on power supply. 2. With vented installation and turned on power supply, Admiral can be used. Press, and open running water to ensure flow rate of more than 3,2 l/min for flow heaters 12-21 kw and more than 2 l/min for flow heater 7,5 kw. 3. In order to turn device off simply stop using hot water. 4. Use and buttons to change requested temperature. 5. During standard operation display shows current water temperature, by pressing buttons set temperature is visible. 6. Device is equipped in safety valve, which will be triggered automatically when inside pressure exceeds 1,2 Mpa. 6

7. Press to learn electricity and water usage. 8. Admiral has build-in memory ensuring all parameters are kept in case of lack of electricity 9. If the unit has been paused, you may initially get a short burst of very hot water while you turn on again. Please run the water through for a few seconds to let the temperature settle down. Please check hot water with hand before you taking a shower. If the unit will not be used in winter, drain out water completely so that the heater will not freeze and be permanently damaged. Control panel: Information is shown when reaching requested temperature is not possible as a consequence of too high demand for hot water or too low starting temperature. Information of flow heater status - blinking icon signals water consumption. Flow rate activating heating: 3,2 l/min for flow heaters 12-21 kw and 2 l/min for flow heater 7,5 kw. Counter showing electricity and water consumption. Change by pressing button. Maintenance: Although it is not required by any regular maintenance procedures, please ensure consistent water flow, it is recommended for the following maintenance: 1. Periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head. Please periodically clean inlet strainer and the shower to keep a free water flow. 2. There is a built in meshed gasket screen at inlet connection which should be cleaned from periodically depends on your water quality. Please shut the water flow before doing so. Technical parameters: Power and supply 7,5 kw 12 kw 15 kw 18 kw 21 kw 230 V~ 400 V~ 400 V~ 400 V~ 400 V~ Minimal cable requirement 3 x 6 mm2 5 x 2,5 mm2 5 x 2,5 mm2 5 x 2,5 mm2 5 x 2,5 mm2 Water temperature range 30-55 C 30-60 C 30-60 C 30-60 C 30-60 C Minimal current 32,61 A 3x17,3 A 3x21,7 A 3x26 A 3x30,3 A Safety fuses 40 A 20 A 25 A 32 A 40 A Tapping size G 1/2 G 1/2 G 1/2 G 1/2 G 1/2 Water supply pressure 0,02-0,6 MPa 0,02-0,6 MPa 0,02-0,6 MPa 0,02-0,6 MPa 0,02-0,6 MPa Water flow activating heating 2 l/min 3,2 l/min 3,2 l/min 3,2 l/min 3,2 l/min Water temperature limiter 67 C 72 C 72 C 72 C 72 C Overheating sensor 95 C 90 C 90 C 90 C 90 C Flow rate with Δt=30 C 3,6 l/min 5,8 l/min 7,2 l/min 8,7 l/min 10,1 l/min Protection IP25 IP25 IP25 IP25 IP25 7

Dimensions: Troubleshooting: Problem Cause Solution Water leakagefrom connections. A. Not properly screwed connections. B. Lack of seal. A. Try to screw properly. B. Exchange seal. LED is not working. A. Lack of electricity. B. Damaged diode. A. Connect electricity. B. Exchange diode (service). Buttons does not work. A. Water supply is turned off. B. Too low water pressure. C. Device malfunction. A. Turn water supply on. B. Check water pressure. C. Service required. Water is too hot. A. Too high water temperature setting. B. Too low water pressure. A. Decrease water temperature setting. B. Increase water flow. Water is too cold. A. Too low water temperature setting. B. Too high water demand compared with device power. A. Increase water temperature setting. B. Decrease water flow (e.g. use only 1 intake point at one time). Water pressure is dropping. Mesh filter is filled. Check and clean filter. No water heating. Thermic switch was activated. Take casing off and press reset button. Display shows E1. Water temperature exceeded 67 C. Reduce temp. Increase water supply. Display shows E2. Leakage. Contact service. Display shows E3. Sensor malfunction. Contact service. Any attempt to fix device outside authorized service causes warranty loss! 8