SPACEMOTION SERIES SMM 01

Similar documents
PHOTOELECTRIC AMPLIFIER SERIES

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

MD12-1 Vehicle Loop Detector

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

FlowJam Bulk Flow Detection

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

General Specifications

UNIVERSAL COMPACT SENSORS

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

Installation, Operating and Maintenance Manual

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Operating Instructions. Digital Radar Motion Detector With Infrared Remote Control MWD BF. Hörmann KG Verkaufsgesellschaft

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Retroreflective sensor with polarization filter

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

MD12-2 Vehicle Loop Detector

Retroreflective sensor with polarization filter

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

M2500 Engine Controller Installation Manual

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

REA 105 Arc Protection Module. Operator s Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

I/A Series 716C 1/16 DIN Temperature Controller

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

Snifter. User Manual. Distributor

English. Italiano. Português. Françias. Español

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

AO Annunciator Module

U L T R A S O N I C G A S L E A K D E T E C T O R

Ultrasonic Proximity Sensor

DESIGN EASY ADJUSTMENT

APM110 LOW AIR VELOCITY ALARM

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

GAS SUPRESSION CONTROL PANEL:

D-TEK -MS Vehicle Loop Detector. Operating Instructions

Constant voltage 3-phase rectifier.

SENSA MRE DDM MR

QT50RAF Radar-Based Sensor

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Vibracon LVL-A* Level limit switch for liquids, compact design

PTE0705 Electric Fence Monitor

Door Release Power Supply

ARCHITECTURAL DOOR HARDWARE SENSORS CATALOG

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Movement-based energy control

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

SELECTION TABLE x 42 x x 48 x x 50 x M12 x 70. Housing material. Typ. operating range/scanning range [mm]

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

Flostop TS D7E and A8E. Operation Manual

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

General Purpose IO Technical Manual

Alarm Panel Operating Instructions

Ceiling PIR HS presence detector. Product Guide. Overview. Features

5.0. Photoelectric Sensors. Technical Reference. Introduction

Operation and Maintenance Manual

R-GAGE QT50R-AFS Sensor

Microwave Doppler Flow Switch. Installation & Operation Manual

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

IR FLAME DETECTOR RIV-601/F

Snifter ATEX22 VERSION. User Manual. Distributor

WIO 200B and WIOI200B Water in oil sensor

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

ENGINEERED PARKING SYSTEMS MODEL 3416D

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Flopurge TS. Operation Manual

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

Transcription:

SPACEMOTION SERIES SMM 01 Description K-Band motion and direction detection Max sensing range: 3 metres Adjustable sensing field range Adjustable slow speed zone Selectable background suppression Selectable direction sensitive detection Adjustable off time delay 10-30 V dc or 24 V ac/dc supply voltage Power and output indicators Solid state relay output monitor function (Sniffer) Compact IP67 housing design Especially designed for escalator and moving-walk applications The SpaceMotion series is a compact Doppler radar sensor that detects motion in the detection area using the latest in microwave technology and a powerful microprocessor. The compact design allows it to be installed in space limited locations, where traditional motion sensors cannot be installed. The microwave technology allows the sensor to be mounted behind plastic constructions for out-of-sight installations. The Doppler radar sensor detects objects that are in motion towards or away from the sensor. People passing the sensor perpendicular (i.e. with no intention of entering an escalator) will have no or very low speed relative to the sensor such motion can remain undetected. The detection field is divided into two parts; low-speed zone and highspeed zone. The part of the field closest to the sensor is the low-speed zone where low speed motion is detected. This is intended to detect people in a multi-storey building that are moving from one escalator to the next making a semi-circular movement/turn i.e. perpendicular to the sensor and with a relatively low speed. The extension of the low speed zone relative to the high speed zone can be adjusted from 0 100% of the total range. Total range is also adjustable. The sensor also includes a background suppression feature which allows the sensor to ignore all constant movements of minor objects (either directly or indirectly detected through reflections) e.g. handrails. Technical Data ac/dc 10-30 V dc / 24 V ac Supply voltage dc 10-30 V dc Voltage ripple +/ 15 % Solid state 100 ma monitor function Yes (dc model only) Reverse polarity protected Yes Short circuit protected Yes Power consumption Max 600 mw Technology Microwave K-Band, 24.125 GHz Horizontal field +/ 40 Vertical field +/ 16 Power on indicator Green LED indicator Yellow LED 0-3 m, potentiometer adjustable 0-10 sec, potentiometer adjustable Background suppression Selectable Low speed zone extension Potentiometer adjustable Housing dimension (w x h x d) 50 x 50 x 30 mm Housing material Plastic, PVC Ø 4 mm 4 x 0,14 mm 2 Environmental Data Vibration 10-55 Hz, 0,5 mm Shock 30 g Temperature, operation 20 to +55 C Temperature, storage 40 to +80 C Sealing class IP 67 Approvals a SPACEMOTION SERIES I 1

SMM 01 SPACEMOTION SERIES Available Types Type Power Supply Housing 5 m cable (w x h x d) Order Reference 10-30 V dc 24 V ac / 10-30 V dc 50 x 50 x 30 Low SMM 01 L S50P 5 Solid SMM 01 H S50P 5 State NC Low Relay SMM 01 L S50P 5 SMM 01 H S50P 5 0-3 m s Cable Supply + Supply Wiring Diagrams Sniffer Sniffer (load as NPN) (load as PNP) (load as NPN) (load as PNP) 2 I SPACEMOTION SERIES

SPACEMOTION SERIES SMM 01 Dimensions and Descriptions 50,8 29,5 13,9 23 13,9 50,8 50,8 49,8 27,5 5,5 Ø 4 Direction sensitive on Direction sensitive off Signal summation on Signal summation off Background suppression on Background suppression off LED indicators speed zone (Units in mm) Sensing Characteristics Sensitivity (normalised) 100 90 80 70 60 50 40 30 20 10 0 90 75 60 45 30 15 0 15 30 45 60 75 90 Degrees Elevation Azimuth Azimuth Elevation SPACEMOTION SERIES I 3

SMM 01 SPACEMOTION SERIES Applications ESCALATOR Pedestrian detection Telco reserves the right to change specifications without notice. 4 I SPACEMOTION SERIES

SMM 01 USER MANUAL Spacemotion Series EN tel Product Data Electrical Data Supply voltage (*) 10-30 V dc or 24V ac Power consumption Max 600 mw : Solidstate 100mA / 30 DC (*) Depends on type, 10-30V dc types have build-in output monitoring function (sniffer). Steps Check the power supply complies with electrical data. Make sure power is off. Connect all wires according to wiring diagrams. Turn on power. Wires/Pins Cable Supply + Pin 1 / 4 pin, M12 plug, male Environmental Data Temperature, operation -20 to +55 C Sealing class IP 67 Supply Pin 3 / (load) Pin 4 / Sensing 0-3m Horizontal field +/-40 degrees Vertical field +/-16 degrees Indicators Green LED Power On Yellow LED status. (See output logic) Blink for output alarm (*) (*) For types with build-in output monitoring function. Pin 2 / Adjustments Mechanical adjustment Sensor plug Notice that the sensing field is not symmetrical. The sensing field is in the direction perpendicular to front of the housing. The sensing field is narrow in the directions where the cable is inserted and wide in the direction orthogonal to the cable insertion. Notice that there are two different types of the sensor marked with L and H. Whenever two sensors are used to detect the same objects, use one of each type, to avoid risk of interference. Available Models Type Model Illustration SMM 01 L S50P SMM 01 H S50P SMM 01 L S50P SMM 01 L S50P Supply Voltage 10 30 V dc 24 V ac / 10 30 V dc Low Low Solid State Relay NC Sensing 0 3 m Acces to potentiometers and LED s The sensor has to be disassembled in order to get access to potentiometers, LED s and switch. The enclosure can be taken apart if the 4 top screws are removed, and the PCB-board will be visible as shown in figure 1. Potentiometers (*) Extension of high-speed zone adjustment Within the sensing range, there are two zones; a high speed zone and a low speed zone. In the low speed zone which is close to the sensor, objects with speeds down to app. 20 cm/s will be detected. This is advantageous in order to detect crossing traffic close to the escalator, for instance when traffic is passing from one escalator to the next escalator in a multi-storey building. In the high speed zone only objects with speed larger than 0.4 m/s = 1.5 km/h will be detected. This will to reduce cross-traffic detection, but on the other hand still detect motion towards the sensor. (*) See figure 1. For radar sensor it is the speed towards the sensor that matters. (or more precisely the magnitude of the velocity projected on the line between the sensor and the object). Increasing the potentiometer will increase the fraction of the high speed zone and reduce the size of the low speed zone. Delay on de-activation of output can be adjusted between 0 s and 10 s Dip switches (*) 1 Background suppression on/off. Minor signals from constant signal contributors as for instance fluorescent light tubes and constantly moving parts as handrails on escalators, that may lead to unwanted detection are suppressed. Disable the function if it is not needed. Wiring diagrams The sensor has a solid-state relay output, and for the dc-versions also with an integrated output monitor Sniffer. Connect as below to ensure correct function of the sniffer. If faulty connected or failure is found the output is de-energised and the yellow LED will start blinking. Ensure correct connection and repower the sensor to escape the fault mode. If there is no Sniffer, i.e. the ac/dc-versions, there are no special requirements for connection of the opto-coupled solid state relay output. Configuration of NPN output 2 Signal summation on/off. If signal summation is on, multiple objects with different speed are all contributing to detection. Can provide more consistent detection of for instance legs, because these consist of different minor parts moving with different velocity relative to the sensor. Turn signal summation off if the range is larger and the sensor is directed towards the body, because the sensor then will have less sensitivity to background traffic. 3 (**) Direction sensitive on/off. If on the sensor will only detect objects moving towards the sensor. If off the sensor will detect both objects moving towards and away from the sensor. (*) See figure 1 (**) Only present for direction sensitive types Logic Detection indicator Moving objects present OFF OFF No objects or non-moving objects ON ON Configuration of PNP output Electrical adjustment 1 2 3 Turn potentiometer fully clockwise for maximum range. Turn Off-delay fully anti clock wise to remove off-delay, for instant response. Turn high speed zone fully anti clock wise to remove high speed zone, for maximum motion sensitivity. This setting corresponds to the factory setting. Check if the sensing distance is adequate, but not excessive. Turn the potentiometer anti clockwise in steps until suitable range is obtained. With the speed zone set to zero (fully anti clock wise) the sensor will detect all motions down to 20 cm/s in the full sensing range. Crossing traffic will therefore be detected in the entire sensing range. Turn the speed zone potentiometer clockwise in steps in order to make the part of the sensing zone which is distant from the sensor to a high speed zone. Check whether crossing traffic is detected. 4 Finally increase the Off-delay if needed by the control system. Website: www.telcosensors.com Warning V 1.3 Part Number: 0666220820 E-Mail: info@telcosensors.com April 2017 edition This product is not a safety system and must not be used as such.! It is not designed for personnel safety applications, and must not be used Made in Denmark as a stand alone personnel safety system. Telco A/S reserves the right to make changes without prior notice