Oil-in-Water Monitoring. for. Marine and Industrial. Applications

Similar documents
Oil-in-Water Monitoring. for. Marine and Industrial. Applications

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD ppm Bilge Alarm

Bristol Babcock Oil Content Monitor "oil in water"

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Oil-in-Water-Monitor. Type OMD-32 OMD-32A. DECKMA HAMBURG GmbH

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

marine Specialists in water quality monitoring

Turbimax CUE21 / CUE22

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

RIVERTRACE ENGINEERING LTD

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

GESTRA Steam Systems OR English. Installation Instructions Oil & Turbidity Detector OR 52-7

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Low Temperature Zirconia Oxygen Analyzer

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Turbimax CUE21 / CUE22

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Certificate: / 29 April 2014

continuous emissions monitoring Combustion & Environmental Monitoring

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Product data sheet Palas Fidas 200 S

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Mercury Vapor Monitor VM-3000

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Air & Water Heat Pump R832

SIMRAD GD10 IR GAS DETECTOR

VM-3000 Mercury Vapor Monitor

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

88MLV Series Open Channel Modular UV Systems

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Danfoss gas detection units

LMF Rotary Screw Air Compressors kW LX Range

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Certificate: _01 / 22 March 2013

SIMRAD GD10PE IR GAS DETECTOR

VM-3000 Mercury Vapor Monitor

Certificate: _01 / 22 March 2013

Technical Information OUSTF10

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

LC2200 Level Controller Installation and Maintenance Instructions

APPLICATION DATA SHEET

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

CLARITY II TURBIDIMETER

COMPACT FLAME CONTROLLER CFC 2000

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

ß-Aerosolmonitor FHT 59 C

LC1350 Level Controller

OPTISENS TUR 2000 Technical Datasheet

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

HPLC Column Ovens and Temperature Controllers

Dependable Solutions for Gas Detection

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

DISCHARGING. electrostatic innovations. Top-Class Discharging

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

An FT-NIR Primer. NR800-A-006

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Annunciator Unit SACO 16 D1. Product Guide

APPLICATION DATA SHEET

Danfoss gas detection units

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CERTIFICATE of Product Conformity (QAL1)

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Bench Top Cooling Tower H893

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Open-area Smoke Imaging Detector. Engineering Specification

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Analog Room Pressure Monitor RPC Series

Technical Information OUSTF10

FIRERAY 5000 range USER GUIDE

HFID Heated Total Hydrocarbon Analyzer Module

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Annunciator unit. Application

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Flostop TS D7E and A8E. Operation Manual

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Transcription:

Product Information Oil-in-Water Monitoring for Marine and Industrial Applications DECKMA HAMBURG GmbH Kieler Straße 316, 22525 Hamburg, Germany Tel.: ++49 (0)40 54 88 76 0, Fax: ++49 (0)40 54 88 76 10 e-mail: post@deckma.com Internet: www.deckma.com Page: 1 / 35

Content Page Company Profile 3 Bilge Alarm Monitor OMD-21 4-5 Bilge Alarm Monitor OMD-2005 6-7 Oil Monitor OMD-12 8-9 Oil Monitor OMD-15 10-11 Oil Monitor OMD-17 12-13 Pictures of Installations OMD-12, OMD-15 and OMD-17 14-16 Oil, Solids, Turbidity Monitor OMD-7 MK II 17-18 Measuring Principle OMD-7 MK II 19 Novel Concept of Oil-in-Water Monitoring 20 Specification OMD-7 MK II 21-23 Pictures of Installation OMD-7 24-31 Applicaton Questionnaire 32-35 Page: 2 / 35

COMPANY PROFILE DECKMA HAMBURG GmbH is a well established company, supplying Oil-in-Water Monitors and Systems to the marine and industrial markets since the early 1970's. The Managing Director, Mr. Günther Schulze, founded the company as a representation office in Germany for companies like Bailey Meters, Metritape, Tanksystem and Bristol Babcock Ltd. DECKMA HAMBURG GmbH has been involved in sales, service, engineering and development of 15 ppm Bilge Alarm Monitors and Tanker Deballasting Systems from the beginning of the MARPOL regulation 73/78 for pollution prevention equipment on board of ships. Since the early 1980's DECKMA HAMBURG GmbH introduced the wellknown OCD-Series of 15 ppm Bilge Alarm Monitors. More than 13.500 OCD-Bilge Alarm Monitors have been sold under the name DECKMA HAMBURG GmbH, mainly to Separator Manufacturers. In the industrial field, DECKMA HAMBURG GmbH developed "Turnkey Monitoring Systems" for the control of waste water in a variety of applications. Demands for better measuring technique required a complete new development. In 1996 DECKMA HAMBURG GmbH launched an all new Oil-in-Water Monitor, the "OMD-7 Industrial Monitor" capable of distinguishing between the different characteristics of Oil particles, Solids particles and Water Turbidity on a continuous basis. This was the beginning of a complete new Series of Oil-in-Water Monitors - the OMD-Series. The latest version of 15ppm Bilge Alarms OMD-2005 meets the IMO Resolution MEPC. 107(49). Up to now we sold more than 16. 000 units of the OMD-Series. Nowadays, DECKMA HAMBURG GmbH is a flexible and innovative enterprise with own Research- and Development Department, Sales and Marketing, Service and Engineering as well as manufacturing facilities for Monitors and Systems. Personal involvement of the Managing Director, the Directors and Employees are the strength of the company. A new factory located in Hamburg with 900 m² floor space was opened in 2001 to cope with the continued business expansion. Based on 35 years experience in continuous Oil-in-Water Monitoring we have gained recognition of this field world-wide. Our aim is to continue with outstanding quality of our products and customer orientated services world-wide. Page: 3 / 35

15ppm Bilge Alarm OMD-21 Compact 15ppm Bilge Alarm, with superior solids suppression capabilities According to the regulations of IMO Resolution MEPC.60(33), U.S. Coast Guard CFR 162.050-35 and Canadian Standard for 5ppm Bilge Alarm We help to protect the Environment Page: 4 / 35

Range (measurement & indication) Specification 0 to 50 ppm Range (IMO specification) 0 to 15 ppm (according IMO regulations) Accuracy better than IMO MEPC.60(33) Electrical power supply 24V to 240V, AC or DC, automatic voltage adjustment Electrical power consumption less than 6W / 6VA Sample Oily water from separator outlet, 0,1-4 l/min. Sample pressure 0 to 10 bar Sample temperature range +1 C to +65 C Sample connections R 1/4 ISO female Alarm 1 & 2 Set Point 1 to 15 ppm (independently adjustable) Alarm 1 operating delay for annunciation purposes 1 to 540 sec. Alarm 2 operating delay for control purposes 1 to 20 sec. Alarm contacts 2 independently adjustable switchover contacts Alarm contact operation mode De-energized in Alarm State Alarm contact ratings 3A, 240V each Alarm output 0..20 ma or 4..20 ma Current Loop, selectable Display Numeric 2-Digit LED Display Ambient temperature +1 C to +55 C Class of protection IP 65 Dimensions 152 mm x 155 mm x 91 mm (width x height x depth) Weight 2,55 kgs (Note: The manufacturer reserves the right to change or amend specifications without notice.) General information The OMD-21, 15ppm Bilge Alarm exceeds the requirements of IMO Resolution MEPC. 60 (33). With the OMD-21 DECKMA Hamburg offer the most advanced oil content measuring device, to prevent reliably pollution from oil. The OMD-21 measures the oil content in the sample through our advanced light scattering principle. Infrared light is passed through the sample and captured by an array of solid state sensors. The signals are then processed and through the application of advanced algorithms the displayed oil content disregards virtually all influence of solids present in the sample. Thus oil content is displayed and turbidity from other sources is disregarded. The OMD-21 provides two independent alarm contacts, for the operation of an audible alarm and/or operation of an automatic overboard discharge shutdown device. Special versions such as shock-proof, antimagnetic for Navy application or options like auto-clean system, higher sample throughputs are available on request. Contacts / Enquiries: Agent: DECKMA HAMBURG GmbH Phone: +49 (0) 40 54 88 76-0 Fax: +49 (0) 40 54 88 76-10 e-mail: post@deckma.com Internet: www.deckma.com Postal Address: Kieler Strasse 316 22525 Hamburg - Germany Page: 5 / 35

Page: 6 / 35

Range: Specification OMD-2005 0 30 ppm, Trend up to 50 ppm Accuracy According IMO MEPC. 107(49) Linearity Up to 30 ppm better than ± 2 % Display Power Supply: Consumption: Alarm Points 1 + 2: Alarm 1 Operating Delay: (for annunciation purpose) Alarm 2 Operating Delay: (for control purposes) System Fault Alarm: Alarm Contact Rating: Alarm Indication: Output Signal: Sample Water Pressure: Sample Flow: Ambient Temperature: Sample Water Temperature: Green Graphic Display 24 V 240 V AC or DC Automatic Voltage Selection < 15 VA Adjustable between 1-15 ppm (Works adjustment 15 ppm) Adjustable between 1 540 sec. (Works adjustment 2 sec.) Adjustable between 1 10 sec. (Works adjustment 10 sec.) Red LED Potential free 1-pole change over contacts, 3 A / 240 V Red LED's 0 20 ma or 4 20 ma, reversible ext. Load < 150 0,1 10 bar Approx. 0,1-4 l/min. depend. to pressure + 1 to + 55 C + 1 to + 65 C Roll: Up to 45 Size (over all): Degree of Protection: IP 65 Weight: Pipe Connections: 360 mm W x 240 mm H x 100 mm D 7,3 kgs R ¼" Female Contacts / Enquiries: Agent: DECKMA HAMBURG GmbH Phone: +49 (0) 40 54 88 76-0 Fax: +49 (0) 40 54 88 76-10 e-mail: post@deckma.com Internet: www.deckma.com Postal Address: Kieler Strasse 316 22525 Hamburg Germany Page: 7 / 35

OIL-IN-WATER MONITORS OMD-12 Series for continuous measurement of Oil-in-Water Model OMD-12 A Oil-in-Water Monitors and Systems for Industrial Applications Page: 8 / 35

Besides our Oil/Solids/Turbidity Monitor, Type: OMD-7, DECKMA HAMBURG GmbH has expanded the scope of supply with the OMD-12 Series, especially developed for applications in clean water or with a low content of solids in the water. This Series is especially for the quick, continuous control of Oil-in-Water in many different applications. Utilizing the latest "state of the art" in micro-processor design and measuring technique, the benefits of the OMD-12 are: Easy to operate Improvement on Solids suppression Variable Parameters Compact Model 14 Segment LED's Reliable Light Weight (3,5 kgs) OMD-12 with ManualClean Unit SPECIFICATION OMD-12 SERIES Range: 0-30 ppm (trend indication to 50ppm) Accuracy: Better than +/- 2 ppm insoluble Oil (with special calibration) Degree of Protection: IP 65 Size OMD-12: 175 x 190 x 220 mm (W x H x D) Size OMD-12 A: 210 x 330 x 220 mm (W x H x D) Sample Temperature: +1 to +70 C Alarm Contact Rating: Potential-free 1 pole change-over contacts, 3 A / 24 V Alarm Operating Points: 15 ppm (Factory Set) adjustable from 1-30 ppm Alarm 1 & 2 Operating Delay: 2-30 sec. adjustable Power supply: 24 Volt AC/DC, other voltages on request Output Signal: 0-20 ma or 4-20 ma, reversible Ri < 500 (Change or amendment of specifications without notice.) Additional Equipment like Sample Lift Pumps and Sample Conditioning Units available on request. Models: OMD-12 - without Autoclean-System OMD-12A - with Autoclean-System Contacts / Enquiries: DECKMA HAMBURG GmbH Kieler Straße 316, 22525 Hamburg / Germany Telephone: +49 40 54 88 76 0 Telefax: +49 40 54 88 76 10 e-mail: post@deckma.com Internet: www.deckma.com Agent: Page: 9 / 35

OIL-IN-WATER MONITORS OMD-15 Series for Boiler Feedwater and Condensate Model OMD-15A with Autoclean System Continuous Monitoring of Oil-in-Condensate or Oil-in-Boiler Feedwater Page: 10 / 35

The OMD-Series includes a Monitor, the OMD-15, for the control of Oil-in-Boiler Feedwater or Boiler Condensate. This Monitor is type approved by Germanischer Lloyd in accordance with the IMO-Resolution MEPC.60 (33) and with the "Technische Regeln für Dampfkessel TRD 604", sheet 1. Utilizing the latest "state of the art" in micro-processor design and measuring technique, the benefits of the OMD-15 are: Easy to operate Improvement on Solids suppression Variable Parameters Compact Model 14 Segment LED's Reliable OMD-15 Light Weight (3,5 kgs) SPECIFICATION OMD-15 SERIES Range: 0-9,9 ppm Accuracy: Better than +/- 1 ppm insoluble Oil (with special calibration) Degree of Protection: IP 65 Size OMD-15: 175 x 190 x 220 mm (W x H x D) Size OMD-15A: 210 x 330 x 220 mm (W x H x D) Sample Temperature: +1 C to +90 C Alarm Contact Rating: Potential-free 1 pole change-over contacts, 3 A / 24 V Alarm Operating Points: 2 ppm (Factory Set) adjustable from 0,2-9,9 ppm Alarm 1 & 2 Operating Delay: 2-20 sec. adjustable Power supply: 24 Volt AC/DC, other voltages on request Output Signal: 0-20 ma or 4-20 ma, reversible Ri < 500 (Change or amendment of specifications without notice.) Additional Equipment like Sample Lift Pumps and special Coolers available on request. Models: OMD-15 - without Autoclean-System OMD-15A - with Autoclean-System Contacts / Enquiries: DECKMA HAMBURG GmbH Kieler Straße 316, 22525 Hamburg / Germany Telephone: +49 40 54 88 76 0 Telefax: +49 40 54 88 76 10 e-mail: post@deckma.com Internet: www.deckma.com Agent: Page: 11 / 35

OIL-IN-WATER MONITORS OMD-17 Series for continuous measurement of Oil-in-Water Model OMD-17 with Auto Clean Unit Oil-in-Water Monitors and Systems for Industrial Applications Page: 12 / 35

The OMD-17 Series is designed for higher oil concentrations up to 100 ppm oil-in-water. It is suited especially well for various cooling water applications. This Monitor is type approved by Germanischer Lloyd in accordance to the IMO-Resolution MEPC.60 (33) and with increased oil concentrations. Utilizing the latest "state of the art" in micro-processor design and measuring technique, the benefits of the OMD-17 are: OMD-17 Easy to operate Improvement on Solids suppression Variable Parameters Compact Model 14 Segment LED's Reliable Light Weight (3,5 kgs) SPECIFICATION OMD-17 SERIES Range: 0-99 ppm Accuracy: Better than +/- 5 ppm insoluble Oil (with special calibration) Degree of Protection: IP 65 Size OMD-17: 175 x 190 x 220 mm (W x H x D) Size OMD-17 A: 210 x 330 x 220 mm (W x H x D) Sample Temperature: +1 to 90 C Alarm Contact Rating: Potential-free 1 pole change-over contacts, 3 A / 24 V Alarm Operating Points: 15 ppm (Factory Set) adjustable from 1-99 ppm Alarm 1 & 2 Operating Delay: 2-30 sec. adjustable Power Supply: 24 Volt AC/DC, other voltages on request Output Signal: 0-20 ma or 4-20 ma, reversible Ri < 500 (Change or amendment of specifications without notice.) Additional Equipment like Sample Lift Pumps and Sample Conditioning Units available on request. Models: OMD-17 - without Autoclean-System OMD-17A - with Autoclean-System Contacts / Enquiries: Agent: DECKMA HAMBURG GmbH Kieler Straße 316, 22525 Hamburg / Germany Telephone: +49 40 54 88 76 0 Telefax: +49 40 54 88 76 10 e-mail: post@deckma.com Internet: www.deckma.com Page: 13 / 35

Examples for OMD-12, OMD-15 and OMD-17 applications. Control of cooling water for transformers in a transformer station. Each transformer is connected to a separate coolingstream. The cooling water is controlled by an OMD-15 A Monitor with a sample lift pump. Page: 14 / 35

Page: 15 / 35

OMD-12A with sample lift pump for the control of cooling water. The flow of the sample water is approx. 2-4 l/min. Sample is taken in bypass condition from the main pipe. (DN 65) Page: 16 / 35

SETTING NEW STANDARDS FOR CONTINUOUS MONITORING OF: Oil-in-Water Multi-Functional-Monitor Type: OMD-7 MK II Accurate monitoring of: Oil-in-Water Solids-in-Water Turbidity We help to protect the Environment. Page: 17 / 35

DECKMA HAMBURG GmbH are proud to announce the launch of an all new Oil-in-Water Monitor, the "OMD-7 MK II Industrial Monitor", designed to measure the content of Free Oils, Suspended Solids and Turbidity in Water continuously and independently. This design represents the first all new Industrial Monitor capable of distinguishing between the different characteristics of Oil particles, Solid particles and Water Turbidity on a continuous basis. The OMD-7 MK II comprises a compact Measuring Cell, Monitor with integral Computer Unit and Monochrome Alphanumeric Display and our proven Sample Conditioning Unit (SCU) for sample processing. The measurement method employs light scattering as the base technique but uses a novel concept whereby multiple wavelength lightsources combined with multiple detector angles are used to differentiate between the various contaminants within the water phase. Great attention has been given to ensure the instrument construction is rugged whilst remaining easy to use. The proven Automatic cell cleaning device, as used on our OCD range of products, has been incorporated to ensure the measuring cell remains in 100% optimum condition throughout even the most demanding of applications. All variable operational parameters can be adjusted on site by key inputs at the Monitor Key Pad. These include Oil, Solids and Turbidity range and Alarm Set Points, Alarm Time Delays and Frequency of Cleaning Cycle. By use of this novel Light Scattering technique the OMD-7MK II is capable of measuring Free Oil, Solids and Turbidity in the following applications: Surface Water Run-Off from Power Stations, Chemical Plants, Refineries and Petroleum Tank Farms. Boiler Condensate returns, Produced Water Discharge from Production Platforms and FPSO's, Cooling Water in a variety of Industrial environments. Contacts / Enquiries: DECKMA HAMBURG GmbH Kieler Straße 316, 22525 Hamburg / Germany Telephone: +49 40 54 88 76 0 Telefax: +49 40 54 88 76 10 e-mail: post@deckma.com Internet: www.deckma.com Agent: Page: 18 / 35

Jan. 2000 Measuring Principle of the OMD-7 MK II The principle of measurement is based on the scattering of light, internationally known as "Scattered Light Principle". The measurement is based on the fact that oil droplets and solids particles present in the sample water scatter light (due to the system arrangement in the measuring cell). The use of three different wave length for the incident light and the angular arrangement of the receivers allow the monitoring of typical scattered light distribution patterns of oil droplets and solids. The intensity of scattered light from the sample glass tube is received by the solid state detectors. After amplification the signals converted into digital data. A microprocessor controls data acquisition, data integrity and light source intensities. The data is sent to the electronic unit for further processing. The oil content can now be calculated independently from the solids content as well as the sample turbidity. All calculated values are displayed on a LCD display. Parallel to the above measurements, the projected light signals are monitored and in the absence of the light-beams, the alarm circuits are activated ("Monitor Fault Alarm"). Emitter Sample cell Receiver Optical Arrangement Page: 19 / 35

Novel Concept of Oil-in-Water Monitoring Introduction Environmental awareness has forced the introduction of stricter discharge limits for oil emission/pollution. Therefore the accuracy requirements for measuring equipment are increasing. Natural turbidity of water, caused by solids or biological growth has always had an adverse effect on oil content measuring equipment. Continuous monitoring of the free oil content, even in waste water, now becomes possible with the new OMD-7 oil monitoring device from DECKMA HAMBURG GmbH (Germany). Measuring Principle After intensive research a novel concept for oil-in-water monitoring was developed. It features a multi-angle multi-wavelength optical measurement system. The water sample is treated by a sample conditioning unit to ensure full homogenisation. The data acquired by the optical system yields different scatter patterns that allows discrimination of solids particles from oil particles in the sample stream. Natural sources of turbidity such as mud or algae does not influence the oil content measurement up to a high level of solids contamination. The turbidity of the sample is also displayed. The sensitivity of the new measuring concept is well suited for oil separator monitoring and coolant control. Scattered light measurements could not replace laboratory analysis in all cases, but can now offer a much more accurate reaction to potential pollution risks. More important, the OMD-7 requires no hazardous chemicals, solvents or consumables so no toxic waste is produced. A typical application for the OMD-7 is the monitoring of cooling water from a coastal power station (see fig.). Due to tidal variations the intake water had differing levels of turbidity, but this solids content can now be discriminated from the oil content. O M D- 7 re ad in gs [p p m] 40 30 20 10 Solids Oil 0 0 1 2 3 4 5 6 7 8 Time [days] Figure: DECKMA HAMBURG GmbH OMD-7 Test Results Open coolant system of a coastal power station with periodical tidal influence on the solids content. The general increase in the solids reading is due to seasonal changes. Summary Continuous oil monitoring in waste water and many other industrial applications without using chemicals and consumables is now possible with the new OMD-7 Monitor from DECKMA HAMBURG GmbH. A high background level of solids contamination is no longer a problem with this novel measuring technique. Due to the novel light scattering technique the OMD-7 is capable of measuring free oil, solids and turbidity in the following applications: Surface Water Run-Off from Power Stations, Chemical Plants, Refineries and Petroleum Tank Farms, Boiler Condensate returns, Produced Water Discharge from Production Platforms and FPSO's, as well as Cooling Water in a variety of Industrial environments. Page: 20 / 35

OMD-7 MK II OIL / SOLID / TURBIDITY Monitor This new microprocessor based monitor makes it possible to simultaneously determine the content of both free oils and suspended solids in water streams as well as the water turbidity. -Specification- APPLICATIONS Liquids with low water solubility ie. Diesel oil, petroleum products, synthetic oils, vegetable oils, several chemicals etc. Non-oil, solids contaminations ie. dust, grinding powder, sand etc. Water turbidity measurement ie. water pollution monitoring etc. MEASURING PRINCIPLE RANGE (OIL ONLY) Accuracy: Different wavelength light scattering, (polychrome) multiangle measurement 0-200 ppm, other ranges on request Better than ±5 ppm or ±10% of reading (whichever is greater). Accuracy can be increased optionally by calibration against a specific oil (e. g. up to ±2 ppm or ±5 % of reading (whichever is greater) for Diesel Oil. RANGE (SOLIDS ONLY) Accuracy: 0-800 smu (Solid Measuring Unit, equals 0-800 ppm Test Air Cleaner Dust according to I.M.O), or equivalent content of other solids, depending on solid density. Calibrated against a specific solid: ±5 ppm or ±10% of reading (whichever is greater). Absolute: ~50%, based on different bulk-densities RANGE (TURBIDITY) Accuracy: 0-1000 FTU (Formazin turbidity units) ±5 FTU or ±10% of reading (whichever is greater) RANGE (OIL AND SOLIDS) Accuracy: 0-100 ppm Oil and 0-200 ppm solids in any ratio Oil content reading: Better than ±5 ppm or ±20 % (whichever is greater) Solids content reading: Better than ±5 ppm or ±20 % (whichever is greater) Page: 21 / 35

CALIBRATION Factory set, calibration against specific oil and/or solid is possible. ZERO SETTING Factory adjusted zero drift: 1ppm (oil), 3ppm (solid), 5 FTU (turbiditiy) maximum (automatic cell cleaning) CELL CLEANING Automatic cell wiper RESPONSE TIME 10 sec maximum (for 90% response to step) OUTPUT Voltage or Current Oil: Voltage: 0 to 5V DC, Current: 0(4) - 20 ma Solids: Voltage: 0 to 5V DC, Current: 0(4) - 20 ma Turbidity: Voltage: 0 to 5V DC, Current: 0(4) - 20 ma DIGITAL INTERFACE Optional: Serial - RS 232 DISPLAY LCD-Display, alphanumeric Optional: Remote LED-Display ALARM STRUCTURE Oil: Two independent set points adjustable over the monitor range with individual delay time Solids: Two independent set points adjustable over the monitor range with individual delay time Turbidity: Two independent set points adjustable over the monitor range with individual delay time Condition-alarm Optional: Logic-combination of one alarmpoint of the oil-, solid- and turbidity-alarm each achieves High flexibility in alarm-structure to special conditions specified by the customer Fault-alarm indicates monitor fault, displayed fault-codes guarantee rapid fault-analysis ALARM CONTACTS Potential free single pole changeover contact for each alarmpoint, rating 5A @ 240VAC/300VDC resistive 1.5A @ 240VAC/30VDC inductive Page: 22 / 35

SAMPLE CONDITIONS Flowrate 2 l / min Pressure 0 to 2 bar Temperature 0 to 70 C ENVIRONMENT Temperature -20 to 70 C Humidity, rel. 5-95% ELECTRICAL SUPPLIES Monitor: 100 W, 110/220 VAC, 50/60 Hz Sample conditioning unit: 1.1 kw, 380/440 V, 3-phase, 50/60 Hz AIR SUPPLY 5 to 7 bar, auto cell cleaning SCOPE OF SUPPLY Compact measuring cell with microprocessor based front end electronics. All components are represent latest state of art. Computer based calculation unit with monochrome alphanumeric LCD-display. Coloured TFT-display optional available. Alarm evaluation featuring sophisticated oil to Solids discrimination algorithm. Reliable Sample Conditioning Unit, approved industrial version. The manufacturer reserves the right to alter the above specification without notice. Contacts / Enquiries: Agent: DECKMA HAMBURG GmbH Kieler Straße 316, 22525 Hamburg / Germany Telephone: +49 40 54 88 76 0 Telefax: +49 40 54 88 76 10 e-mail: post@deckma.com Internet: www.deckma.com Page: 23 / 35

Oil-in-Water Monitoring Systems OMD-7 System with Air Compressor and Sample Lift Pump. Page: 24 / 35

OMD-7 System for hazardous area (Air-purged system) Page: 25 / 35

OMD-7 System for 2 sample points. Page: 26 / 35

OMD-7 Components Monitor Measuring Cell Sample Conditioning Unit Page: 27 / 35

OMD-7 System (outdoor-application) Page: 28 / 35

OMD-7 System (outdoor-application) Page: 29 / 35

OMD-7 System "Special" for Separator control with Air Conditioning System, suitable for 4 sample points. Page: 30 / 35

Sample Selection Valves Page: 31 / 35

Application Questions for Industrial Applications Customer: Plant location: Customer Contact: Phone No. : Enquiry No.: Fax No. : Application: Date: Estimated Delivery: 1.0 PLANT LOCATION AND PROPOSED EQUIPMENT LOCATION 1.1 Site conditions: Outdoors Sheltered Fully enclosed room Heated Area Non heated area Hazardous area Non hazardous area Ambient Temperature:: C 1.2 Customer prefered installation: Frame work Steel enclosure Stainless Steel enclosure Glas reinforced enclosure Protection IP: Other enclosure Prefered material for pipework: Copper Stainless Steel Others: 1.3 Equipment installation: Above sample point Below sample point Sample point level Page: 32 / 35

2.0 SAMPLE POINT(S) CONDITIONS 2.1 Number of sample points required: 2.2 Are sample points to be switchable: Yes No If yes: Manual Automatic 2.3 Anti freezing heater for piping: Existing Necessary Not necessary 2.4 Sample is to be taken from: High level pipe Low level pipe Surfaced channel 2.5 If surface, available space for skimmer mounting: x mm 2.6 If pipe, dimensions of pipework: : x mm (id x od) 2.7 Pipe permanently filled: Yes No Min. level: cm Max. level: cm 2.8 Pipe flow rate: Turbulent flow Laminare flow m/sec.: or m³/h: 2.9 Normal pressure in pipe: bar/min.: bar/max.: 2.10 Distance between equipment location and sample points: 1. mm 2. mm 3. mm 3.0 SAMPLE WATER QUALITY Page: 33 / 35

3.1 Sample water temperature: min.: C max.: C 3.2 Are particulates/solids expected at location of the sample point? Yes No If "Yes" what concentration: mg/l 3.3 Are there amounts of gases present in effluent? Yes No If "Yes", concentration: % Type: 3.4 Are there chemicals present in effluent? Yes No If "Yes", concentration: % Type: 3.5 Are algae expected in effluent? Yes No Any other growth: 3.6 What amount of oil is expected in effluent? min.: ppm(mg/l) max.: ppm(mg/l) 3.7 What Type of oil could be in the sample water? Viscosity?(If available) ------------------------------------------------------------- ----------------------------------- 4.0 SUPPLIES 4.1 Available power supply: V Hz A, 1 Phase V Hz A, 3 Phase 4.2 Instrument air supply available? Yes No Pressure: bar 4.3 Clean water supply available? Yes No Pressure: bar 4.4 Is there a local drain available? Yes No Distance to drain line: m 5.0 OUTPUTS Page: 34 / 35

5.1 What type of signal outputs are required: 0-20 ma 4-20 ma Voltage 5.2 What control functions are required, i.e. alarms, sirens, valves: 6.0 ADDITIONAL REMARKS AND INFORMATIONS: 7.0 LOCATION SKETCH: Please return to: DECKMA HAMBURG GmbH Kieler Straße 316, 22525 Hamburg / Germany Telephone: ++49 40 54 88 76 0 Telefax: ++49 40 54 88 76 10 e-mail: post@deckma.com Internet: www.deckma.com Page: 35 / 35