ALPHA+ Light Exposure and Weathering Testing Instrument. Xenotest Alpha+ Features. Xenotest Alpha+ Specifications. Sample Capacity

Similar documents
o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

Ci5000. Weather-Ometer. Accelerating Your Expertise. Setting the Standard for Xenon Weathering

Ci4000. Weather-Ometer. Accelerating Your Expertise. Setting the Standard for Xenon Weathering

Equipment specifications (D6)

UV Weather Resistance Test Chambers

Version: 1603 UV Accelerated Weathering Testers Weice Testing Instrument Co., Limited

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

UV Weather Resistance Test Chamber Technical Data

Mercury Vapor Monitor VM-3000

IWASAKI ELECTRIC CO., LTD

Corrosion Testing... also with Climate Control

Model KBWF 240 Growth chambers with light and humidity

Constant climate chambers

Corrosion Testing Instruments Model 618

VM-3000 Mercury Vapor Monitor

Environmental simulation chamber for complex alternating climate profiles

Constant climate chamber with humidity

Constant climate chamber with ICH-compliant illumination

Model KBWF 720 Growth chambers with light and humidity

Plant growth chambers

Corrosion Testing... also with Climate Control

FITOCLIMA 600 & 1200 PHARMA

Manufacturer since

Constant climate chambers

Latest developments in TPO stabilization for Automotive applications ANTEC MAY 8-10 TH 2017 ANAHEIM, CA

Constant climate chambers

Cyclic Corrosion Testers

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Dry Corrosion. Test Cabinets. acstestchambers.com

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

FITOCLIMA 600 & 1200 STABILITY

ADVANCED. Environmental Chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Dry Corrosion. Test Cabinets. acstestchambers.com

Tabletop 2340 EA-D Class S Autoclave 19 Litres

Constant climate chambers

Photo Stability Chamber

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations


ICH750L. Climate Chamber. Product specification

FITOCLIMA 600 & 1200 STABILITY

VM-3000 Mercury Vapor Monitor

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Instruments Designed for POF & Fibre Optic Cable Testing

Constant climate chambers

Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 1

NC 100. Vertical Steam Sterilizer

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

APPLIED. OMA-406R Rackmount Process Analyzer

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Textil Färghärdighetsprovning Del B02: Färghärdighet mot artificiellt ljus: Provning med Xenonbåglampa Tillägg 1 (ISO 105-B02:1994/Amd.

CTS Your Partner for Customised Technical Solutions

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Infrared Moisture Balance (FD-800)

Reproducible Climate...

TECHNICAL SPECIFICATION

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

Digital Sensors Erythema Sensor PMA2101

UV measurements for medical applications using SiC photodiodes

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Corrosion Testing... also with Climate Control

New Generation KBF 240 series

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Cyclic Corrosion Testers

UV aging test chamber

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

OT SERIES. Bench Top Steam Sterilizers

UMWELTSIMULATION TEMPERATUR VARIO. Walk-in chambers in modular design for multifunctional applications in different industrial fields

ISF1-X (Climo-Shaker)

Constant climate chambers

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Technical Description. Climate Test Cabinet with increased change rates. Stress Screening System Weiss. Mat. No.: Type

STABILITY ICH. ICH Stability Tests

KMF Environmental test chamber for constant climate

OMA-300 Process Analyzer

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

NC SERIES. Horizontal Steam Sterilizers

ISF4-X (Climo-Shaker)

shaker LT-X (Lab-Therm) Space saving stackable incubator shaker

www

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Laboratory thermostatic chambers

THE NEW GENERATION VACUUM PUMP SYSTEM SC

WASTEWATER Online UV%Transmission Analyzer

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

PERFORMANCE TESTERS. Performance Textile Testing

Bernd Eichler Sales Manager

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

PUV, PIR and PFO Series BROCHURE

AC1234 PRODUCT RANGE.

MMT. Moisture Management Tester

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Dated 15-Dec-2000; J. Schilz, subject to change

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

EC 160 CO 2. Incubator

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Textile test methods. Weather resistance Xenon arc radiation. CAN/CGSB-4.2 No. 69-M91. National Standard of Canada

Transcription:

Atlas Material Testing Technology LLC (p) +.773.37.4 (f) +.773.37.5787 Atlas Material Testing Technology GmbH (p) +49. 5.7. (f) +49. 5.7.49 www.atlas-mts.com We reserve the right to make technical changes to the instruments and systems. XENOTEST 6 Atlas Material Testing Technology GmbH All rights reserved. Printed in Germany. BV Pub. No. 563537 US Pub. No. 5 Xenotest Alpha+ Specifications Air-cooled xenon lamp W XENOSENSIV sensor to measure and control irradiance from to nm and the Black Standard Temperature Temperature control selectable either by test chamber temperature (up to C) or both test chamber temperature and Black Standard Temperature simultaneously (up to C) Ultrasonic humidification system Specimen spray system Microprocessor control Parameter check User guided operation by color graphic display TFT full color 5,7 Touch screen Data output via memory card or RS3 / USB interface Instrument-internal memory chip to store instrument data Thermoprinter XenoCal BST Black Standard Thermometer XenoCal WST White Standard Thermometer XenoCal BB Irradiance Sensor XenoCal WB 8 Irradiance Sensor XenoCal NB 3 Irradiance Sensor Irradiance range: nm (in W/m) Filter system Turning Mode Non-turning Mode XENOCHROME 93 W/m 8 W/m XENOCHROME 93 W/m 8 W/m window glass 57 W/m W/m Absorption filter lantern with: 6 IR + UV 7 W/m W/m 7 IR segments 7 W/m W/m 4 IR + 3 window segments 7 W/m W/m 65 W/m 5 W/m IR absorption filter system 6H 7 W/m W/m Temperature and Humidity Range Test chamber temperature: C to C* Black Standard Temperature: C to C* Relative humidity: to 95%* *Depending on the selected filter combination and irradiance as well as the ambient laboratory conditions Standard Optional Utility Requirements Sample Capacity Electrical Sample holders * Sample dimensions L x W (max.) 35 x 46 mm Exposure Area cm V ± %, / Hz (P,N,PE) AC or (P,PE) AC CEE (3 A, 3-pin. 6h) Amperage Maximum power consumption 6 A approx. 5 kva *without additional sensor ( samples during turning mode) Cooling air requirement for xenon lamp m3/h Cooling air requirement for test chamber m3/h Physical Specifications Water consumption for spray system.7 l/min Width x Depth x Height 9 x 78 x 8 mm Weight approx. 8 kg Water consumption for humidity max..33 l/min ALPHA+ Light Exposure and Weathering Testing Instrument

s & Standards Features Xenotest Alpha+ simulates and accelerates the natural weathering process providing reliable results regarding the long-term behavior of materials. It is the universal weathering instrument for testing light- and weatherfastness of any material, offering a variety of options to meet international standards and test methods. A large selection of optical filters to test various end-use conditions and weathering standards Proven xenon lamp technology with long operating life to provide high irradiance levels with low thermal loads Common s q Textiles Light- and weatherfastness in accordance with ISO 5-B, B4, B6 and AATCC TM 6 or manufacturer specific test methods (Marks & Spencer) Large color touch screen featuring multiple language capability for easier programming q Plastics Light- and weatherfastness to meet ISO 489-, 489- and numerous others Automatic control of irradiance and Black Standard Temperature (BST) q Interior Automotive Materials Testing of seat covers, carpeting, etc. in compliance with VDA 7, ISO 5-B6 and test standards defined by the automotive industry Automatic control and measurement of test chamber temperature and humidity q Paints and Coatings Light- and weatherfastness as specified in ISO 34 and others On screen display of diagnostics, program selection and parameter indication Standards A ATCC Adidas ASTM GB/T GME GMW ISO IKEA JASO Marks & Spencer MIL STD Nike SAE VDA VW TM 6H-998 TM 6-4 TM 69 Colour Lightfastness G5 G55 D6695 847-8 9 344 5-B 5-B4 5-B6 5-B 489-489- 34 IOS-PRG- 3 IOS-TM- 7 M 346 C9 C9A 8 F TM 6 J9 J 7 PV 3 PV 399 PV 39 Test assurance and reliability through microprocessor controlled parameter monitoring Data output to a printer, RS3 or memory card Test chamber with omega-shaped xenon lamp and optical components Optional control and calibration via XenoCal Turning and non-turning mode Specimen Spray System Remote Control Email Service Online Monitoring 3

Equipment technology Light 5 Irradiance in the Xenotest Alpha+ Spectral Power Distribution from to 8 nm 4,5 4, ---------- CIE85 (Tabelle 4) ---------- Daylight Extended IR ---------- Xenochrome 3,5 3, q User-friendly Touch Screen Operation The omega-shaped xenon lamp guarantees constant irradiance for standards or high irradiance test methods up to three times the maximum solar radiation. Irradiance [W/m /nm] 4,5 TFT full colour 5,7" touch screen control panel display of all test parameter., Most common test methods preprogrammed; space for custom tests.,5, PC interfaces RS3, Momory Card and Ethernet.,5 Online Programming and Monitoring via optional Add-ons., 3 4 5 Wavelength [nm] 6 7 8 q Reliable Sensor Technology Rotating XENOSENSIV sensor to measure irradiance between and nm and Black Standard Temperature according to ISO/DIN Filter Combinations Stationary sensor to measure and control the test chamber temperature and relative humidity q Versatile Instrument Functionality Supplemental electric heating device to achieve high temperature values even during dark cycles Simultaneous control of test chamber and Black Standard Temperature Ultrasonic humidification system to provide high humidity levels in the test chamber Specimen spray system for sample wetting in weatherfastness tests Integrated water tank to provide ultra-pure water automatically when connected to a supply line Non Aging Filter System XENOCHROME Simulation of solar radiation behind window glass XENOCHROME Simulation of outdoor solar radiation in accordance with CIE publication no. 85, table 4, low temperatures Simulation of outdoor solar radiation in accordance with CIE publication no. 85, table 4, normal temperatures, e.g. ISO 489- or ISO 34 Traditional Filter System window glass filters Simulation of solar radiation behind window glass for exposures at high temperatures (e.g. for automotive interior trim materials) Combination of absorption filters Simulation of solar radiation behind window glass 7 IR Combination of absorption filters 6 IR + UV and UV special glass cylinder Simulation of outdoor solar radiation needed for older standard requirements Combination of absorption filters 4 IR, 3 window glass filters Simulation of solar radiation behind window glass at high temperatures IR absorption filter system 6H Simulation of solar radiation behind window glass, e.g. AATCC TM 6 Option H Flexible filter system for absorption or non-aging XENOCHROME filter system.

Temperature Options & Accessories 7 Temperature Parameters Die Temperatur in the Xenotest Alpha+ im XENOTEST ALPHA+ q The Black Standard Temperature depends on test chamber humidity, irradiance and ambient air temperature in the laboratory. Options & Accessories in the Xenotest Alpha+ q The temperature ranges for outdoor solar radiation and solar radiation behind window glass for non-turning mode operation are displayed in the below temperature control performance graphics. The red lines indicate the test chamber temperatures for each irradiance value between the minimum and maximum blower speed. The blue lines show temperature differences between Black Standard and test chamber temperatures that fall between the minimum and maximum blower fan speed. Adding the corresponding values of the temperature difference and test chamber temperature will result in the relevant Black Standard Temperature. Temperature Control Performance for Outdoor Solar Radiation (XENOCHROME ) XENOCHROME XENOCHROME (High Energy Feld *) q XenoCal BB nm nm (UV) XenoCal Irradiance Sensor to measure irradiance: q XenoCal WB 8 nm 8 nm (UV +VIS) q XenoCal NB 3 3 nm XenoCal BST to measure amd calibrate Black Standard Temperature q XenoCal BB- BST Fan Speed /min. to measure and calibrate irradiance: to measure and calibrate both irradiance and BST simultaneously XENOCHROME XenoCal Irradiance Sensor XenoCal combined irradiance + BST Sensor BST-CHT ( C) q User selectable temperature control based on either the test chamber temperature (up to C) or using simultaneous control of test chamber temperature and Black Standard Temperature (up to C). XenoCal WST to measure, calibrate and adjust White Standard Temperature Fan Speed /min. Regular Specimen Holder for samples up to a thickness of 3 mm 8 9 8 9 Irradiance -nm (W/m ) Special Specimen Holder Temperature Control Performance for Solar Radiation behind Window Glass ( Window Glass) for samples up to a thickness of 5 mm such as automotive upholstery materials Specimen Holders CHT BST-CHT CHT, BST-CHT (C) 6 8 9 Irradiance @ - nm (W/m) Description Maximum Size Exposure Size Rack Capacity Regular Specimen Holder for samples up to 3 mm thick Textiles, plastics, coatings, papers 35 45 mm 35 mm Special Specimen Holder for samples up to 5 mm thick Carpets, plastics, foam-backed materials, thick panels 35 45 mm 35 mm Specimen Holder for Blue Scale Blue scale fabric during weathering tests 35 45 mm

www.atlas-mts.com We reserve the right to make technical changes to the instruments and systems. Atlas Material Testing Technology GmbH All rights reserved. Printed in Germany. BV Pub. No. 563537 US Pub. No. 5 Xenotest Alpha+ Specifications Air-cooled xenon lamp W XENOSENSIV sensor to measure and control irradiance from to nm and the Black Standard Temperature Temperature control selectable either by test chamber temperature (up to C) or both test chamber temperature and Black Standard Temperature simultaneously (up to C) Ultrasonic humidification system Specimen spray system Microprocessor control Parameter check User guided operation by color graphic display TFT full color 5.7" Touch screen Data output via memory card or RS3 / USB interface Instrument-internal memory chip to store instrument data Thermoprinter XenoCal BST Black Standard Thermometer XenoCal WST White Standard Thermometer XenoCal BB Irradiance Sensor XenoCal WB 8 Irradiance Sensor XenoCal NB 3 Irradiance Sensor Irradiance range: nm (in W/m) Filter system Turning Mode Non-turning Mode XENOCHROME 93 W/m 8 W/m XENOCHROME 93 W/m 8 W/m window glass 57 W/m W/m 6 IR+ UV 7 W/m W/m 7 IRsegments 7 W/m W/m 4 IR+3 window segments 7 W/m W/m 65 W/m 5 W/m IR absorption filter system 6H 7 W/m W/m Absorption filter lantern with: Temperature and Humidity Range Test chamber temperature: C to C* Black Standard Temperature: C to C* Relative humidity: to 95%* *Depending on the selected filter combination and irradiance as well as the ambient laboratory conditions Standard Optional Utility Requirements Sample Capacity Electrical Sample holders * Sample dimensions L W (max.) 35 46 mm Exposure Area cm V ± %, / Hz (P,N,PE) AC or (P,PE) AC CEE (3 A, 3-pin. 6h) Amperage Maximum power consumption 6 A approx. 5 kva *without additional sensor ( samples during turning mode) Cooling air requirement for xenon lamp m3/h Cooling air requirement for test chamber m3/h Physical Specifications Water consumption for spray system.7 l/min Width Depth Height 9 78 8 mm Weight approx. 8 kg Water consumption for humidity max..33 l/min