in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

Similar documents
DECLARATION OF PERFORMANCE

Declaration of Performance

See product BS EN :2010

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

Declaration of Performance

Declaration of Conformity Declaration of Performance Notes

COMMISSION DELEGATED REGULATION (EU)

F O C U S D O O R C L O S E R S

For structural use in all types of construction works according to EN

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

CE marking of noise barriers and foundations

DECLARATION OF PERFORMANCE 1 N. For structural use in all types of construction works according to EN

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

DECLARATION OF PERFORMANCE. No EN

YOUR GUIDE TO UNDERSTANDING CPR

DECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN

DECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN

1. Terms defined in the Construction Products Regulation (CPR)

Introduction. Declaration of performance (DoP) CE marking

DECLARATION OF PERFORMANCE. No EN

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 9

Declaration of performance ( DoP ) :

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Guideline Construction Products Regulation (EU) 305/20122

Firetect C. Fire protective products: Fire protective board

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Domestic Garage Doors

DECLARATION OF PERFORMANCE ref. no

DECLARATION OF PERFORMANCE. BS EN 1338:2003 Precast Concrete Paving Blocks DoP M-03

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

DECLARATION OF PERFORMANCE

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

DECLARATION OF PERFORMANCE. EN 1339:2003 Precast Concrete Flag No. M-001

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

European Technical Assessment ETA-14/0176

DECLARATION OF COMPLIANCE PERFORMANCE AND CE MARK

Your Key to achieving C.E Marking Compliance

CPR Guide: EU Rules Practical Impact

CPR Guide: EU Rules Practical Impact

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

GNB-CPR Position Paper: Issuance of certificates under CPR

System Solutions. Quick and simple to construct. Range of partitions. Fully warranted systems. CE Marked. Knauf CE Marking. A guide to CE marking

COMMISSION DELEGATED REGULATION (EU) /... of

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

Technical Bulletin CE marking: from 1st July 2013

Guidance Note No 19/1. CE Marking windows and doorsets

The New EU-Regulation on Construction Products

Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

CE MARKING OF WOOD-BASED PANELS

EUROPEAN TECHNICAL ASSESSMENT

COMMISSION DELEGATED DECISION (EU) / of XXX

Construction Products Regulation (CPR)

EUROPEAN TECHNICAL ASSESSMENT

Implementing the Construction Products Regulation (EU) 305/2011

European Technical Assessment

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

EUROPEAN TECHNICAL ASSESSMENT

Guidance on Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

EUROPEAN TECHNICAL ASSESSMENT

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Record of Amendments. Version Date Amendment Section/page affected

Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND. Manufacturing plant Manufacturing Plant 4 and Plant 9

Mandate M/118 WASTE WATER ENGINEERING PRODUCTS

Guidance Note on the Construction Products Regulation

Council of the European Union Brussels, 21 March 2017 (OR. en) Mr Jeppe TRANHOLM-MIKKELSEN, Secretary-General of the Council of the European Union

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013

EUROPEAN UNION. Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 ENT 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481

(recast) (Text with EEA relevance) out the conformity assessment procedure. Conformity 20 February 2014.

EUROPEAN TECHNICAL ASSESSMENT

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

The effects on the UK Fire Industry. Paul Pope Eng.Tech AIFireE

The results of the impact assessment and of the workshop will be considered in the final proposal of the new directive.

European Technical Assessment

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

Sýnishorn Glass in building - Insulating glass units - Part 5: Evaluation of conformity

Construction Products Directive

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

rebar connection Fosroc International Limited Drayton Manor Business Park Coles Road TAMWORTH STAFFORDSHIRE; B78 3XN GROSSBRITANNIEN

EUROPEAN COMMISSION INDUSTRY AND ENTERPRISES DIRECTORATE-GENERAL AMENDMENT TO :

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Transcription:

DECLARATION OF PERFORMANCE in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) 1. Unique identification code of the product type: ULTRA PROFLEX SP+ES GREY 2. Type, batch or serial number or other identifying mark to identify the construction product as set out in Article 11 (4): Product formulation reference X2008 3. Intended use as foreseen by the manufacturer of the construction product in accordance with harmonised technical specification: Improved deformable cementitious adhesive with reduced slip and extended open time 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as set out in Article 11 (5): Instarmac Group plc Birch Coppice Industrial Estate Danny Morson Way, Dordon Tamworth B78 1SE United Kingdom 5. When applicable, the name and contact address of the authorised representative who has received a mandate for the tasks set out in Article 12 ( 2 ): 6. System or systems for assessment and verification of constancy of performance of the construction product in accordance with Annex V: System 3 +4 7. In the case of a declaration of performance concerning a construction product that is covered by a harmonised standard: The notified body Ceram No. 1289 has carried out initial type testing to System 3 and issued Test report No. (124246) - 17183

8. In the case of the declaration of performance concerning a construction product for which a European Technical Assessment has been issued. 9. Declared performance Essential characteristics Performance Harmonised technical specification Bond Strength as: Initial tensile adhesion 2.1 N/mm 2 Durability for tensile Adhesion: After heat ageing 1.4 N/mm 2 After water immersion 1.1 N/mm 2 BSEN 12004:2007+A1:2012 After freeze/thaw cycles 1.3 N/mm 2 Reaction to Fire Release of dangerous Substances Class E WFT See MSDS CLASSIFICATION - C2 TE S1 10. The performance of the product identified in items 1 and 2 in conformity with the declared performance set out in item 9. The manufacturer as defined in number 4 is solely responsible for drawing up this declaration of performance. Signed for on behalf of the manufacturer by: Tamworth 13.06.13... (Signature)... (Place & Date Issued) Chris Murphy - Technical Director

Ref: DOP 1006 DECLARATION OF PERFORMANCE in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) 1. Unique identification code of the product type: ULTRA PROFLEX SP+ES WHITE 2. Type, batch or serial number or other identifying mark to identify the construction product as set out in Article 11 (4): Product formulation reference X2009 3. Intended use as foreseen by the manufacturer of the construction product in accordance with harmonised technical specification: Improved deformable cementitious adhesive with reduced slip and extended open time 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as set out in Article 11 (5): Instarmac Group plc Birch Coppice Industrial Estate Danny Morson Way, Dordon Tamworth B78 1SE United Kingdom 5. When applicable, the name and contact address of the authorised representative who has received a mandate for the tasks set out in Article 12 ( 2 ): 6. System or systems for assessment and verification of constancy of performance of the construction product in accordance with Annex V: System 3 + 4 7. In the case of a declaration of performance concerning a construction product that is covered by a harmonised standard: The notified body Ceram, No. 1289 has carried out initial type testing to System 3 and issued Test report No. (124246) - 17184

Ref: DOP 1006 8. In the case of the declaration of performance concerning a construction product for which a European Technical Assessment has been issued. 9. Declared performance Essential characteristics Performance Harmonised technical specification Bond Strength as: Initial tensile adhesion 2.1 N/mm 2 Durability for tensile Adhesion: After heat ageing 1.7 N/mm 2 After water immersion 1.4 N/mm 2 BSEN 12004:2007+A1:2012 After freeze/thaw cycles 1.4 N/mm 2 Reaction to Fire Release of dangerous Substances Class E WFT See MSDS CLASSIFICATION - C2 TE S1 10. The performance of the product identified in items 1 and 2 in conformity with the declared performance set out in item 9. The manufacturer as defined in number 4 is solely responsible for drawing up this declaration of performance. Signed for on behalf of the manufacturer by: Tamworth 13.06.13... (Signature)... (Place & Date Issued) Chris Murphy - Technical Director