Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Similar documents
Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGAPULS 64

Safety instructions VEGABAR 81, 82, 83, 86, 87

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

OPTIBAR DP 7060 Supplementary Instructions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Safety instructions VEGAPULS 62

Certificate of Compliance

Technical Data. Dimensions

OPTIBAR P 1010/2010 C Supplementary instructions

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Technical Data. Dimensions

Inductive slot sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Manufacturer declaration. 3-A, Installation and Cleaning Instructions. VEGAPULS 63 Hygienic process fittings. Document ID: 46197

Certificate of Compliance

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

PEPPERL+FUCHS GmbH

OPTIWAVE X500 Supplementary Instructions

UL HAZARDOUS LOCATIONS SERVICES

Technical Data. General specifications. Rated operating distance s n 5 mm

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Tank Gauging System Special Safety Instruction

Supplementary instructions Bypass 72 Bypass tube with VEGAFLEX level sensor

Hazardous Area Classifications and Protections

Technical Data. Dimensions

Certificate of Compliance

Safety instructions Display and adjustment module

Certificate of Compliance

Certificate of Compliance

Annubar Flowmeter Series

Certificate of Compliance

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

Certificate of Compliance

Understanding Hazardous Locations Concepts

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Certificate of Compliance

Fire Alarm System Accessories

Guide for hazardous areas

Manual Power relay SR853

Certificate of Compliance

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Safety instructions VEGAMIP MPR61(*).G*/DK****R/T*** VEGAMIP MPT61(*).G*/DK****T*** VEGAMIP MPR62(*).G******R/T*** IECEx BVS Ex t IIIC T..

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

4) Intrinsic Safety Certification

Certificate of Compliance

User s Manual YTA610 and YTA710 NEPSI Certification

INSTRUCTION & SERVICE MANUAL

EU DECLARATION OF CONFORMITY

Intrinsically Safe Solutions

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Fire Alarm System Accessories

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Certification Supplement Manual

standards: standards:

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

OilSET-1000 (12 VDC)

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

IECEx Certificate of Conformity

CONTROL BE MADE CHANGES MAY NOT. Page 1

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

IECEx Certificate of Conformity

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Guide to Intrinsically Safe Portable Radios

Certificate of Compliance

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Certificate of Compliance

SET Installation and Operating Instructions. Level switch for one sensor

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Safety instructions VEGATOR 121, 122

Instrumentation Products and Applications

Declaration of conformity

Certification Supplement Manual

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Safety instructions VEGASWING 61, 63

Today's world of increasing

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Certificate of Compliance

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

IECEx Certificate of Conformity

Certification Supplement Manual

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Transcription:

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924

Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application conditions... 4 5 Protection against static electricity... 4 6 Installation/mounting... 5 7 Installation Diagram... 5 8 Material resistance... 6 Please note: These safety instructions are part of the documentation: 27720 - VEGADIS 61 43814 - VEGADIS 81 48924 - Certificate CSA 14.2662675 2 VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

1 Area of applicability These safety instructions apply to the indicating and adjustment unit VEGADIS DIS61.CC/O**, DIS81.CC/O****** according to Certificate CSA 14.2662675 (certificate number on the type label) and to all instruments with the number of the safety instruction (48924) on the type label. 2 General information The VEGADIS DIS61.CC/O**, DIS81.CC/O****** is used for separate scaling and visualization of measured values. The VEGADIS DIS61.CC/O**, DIS81.CC/O****** is suitable for applications in hazardous atmospheres of all combustible materials of explosion group IIA, IIB and IIC, for applications requiring EPL-Ga- or EPL-Gb-instruments, as well as Class I, II and III Division 1 and 2 Hazardous Locations. The atmospheres can also be combustible gases, mists, vapours, dusts, fibers or flyings. If the VEGADIS DIS61.CC/O**, DIS81.CC/O****** are installed and operated in hazardous areas, the general Ex installation regulations IEC 60079-14 as well as these safety instructions must be observed. For installations in Class I, II and III Division 1 and 2 Hazardous Locations, the installtion control diagram from Chapter 6 of these Safety Instructions must be followed. The operating instructions as well as the corresponding valid Ex installation regulations or standards for electrical equipment must generally be observed. The installation of explosion-endangered systems must always be carried out by qualified personnel. Safety Markings INTRINSICALLY SAFE/SECURITE INTRINSEQUE Ex ia IIC T6 T1 Ga, Gb CL I Zone 0 AEx ia IIC T6 T1 Ga, Gb CL I Div 1 Group A, B, C, D, CL II Div 1 Group E, F, G, CL III 3 Technical data Electrical data VEGADIS DIS61.CC/O**, DIS81.CC/O****** Power supply and signal circuit: (terminals 5, 6, 7, 8) Ignition protection type intrinsic safety Ex ia IIC For connection to a certified, intrinsically safe circuit. Maximum values: U i = 6.4 V P i = 332 mw L i = negligibly low C i = negligibly low For connection to the indicating and adjustment circuit, terminal 5, 6, 7, 8 of VEGAPULS PS6*.***, VEGAFLEX FX6/8*.***, VEGABAR BR5/6/8*.***, VEGACAL CL6*.*** or VEGASON SN6*.***. For the maximum permissible values for the external inductance L o and capacitance C o of the connecting line between VEGADIS 61/81 and the connected sensor are mentioned in the EC type approval certificate. VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** 3

Circuit of the indicating and adjustment module: (spring contacts in the connection compartment) VEGADIS61.CI** Communication circuit: (I²C-BUS socket in the connection compartment) Ignition protection type intrinsic safety Ex ia IIC Only for connection to the indicating and adjustment module PLICSCOM. Ignition protection type intrinsic safety Ex ia IIC Only for connection to the intrinsically safe signal circuit of an interface converter VEGACONNECT (PTB 01 AT- EX 2007, PTB 07 ATEX 2013 X). The metal elements of the VEGADIS DIS61.CC/O**, DIS81.CC/O****** are electrically connected to the earth terminals. The intrinsically safe circuit is electrically isolated from elements that may be earthed. 4 Application conditions The max. permissible ambient temperatures depending on the temperature classes are specified in the following tables. Division 1/EPL-Ga installations Temperature class T6-20 +37 C T5-20 +50 C T4, T3, T2, T1-20 +60 C Temperature on the electronics housing For applications requiring EPL-Ga-instruments, the pressure of the explosive mixtures must be between 0.8 1.1 bar. The application conditions during operation in areas with no explosive mixtures are stated in the manufacturer information. Division 1/EPL-Gb installations Temperature class T6-40 +53 C T5-40 +68 C T4, T3, T2, T1-40 +85 C Temperature on the electronics housing The prerequisites for operation in the absence of explosive mixtures can be found in the manufacturer specifications. 5 Protection against static electricity The VEGADIS DIS61.CC/O**, DIS81.CC/O****** housing is provided with a caution label referring to the safety measures that must be taken in case electrostatic charges occur during operation. Caution: Plastic parts! Danger of static charge! Avoid friction No dry cleaning 4 VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Do not mount in areas with flowing, non-conductive products 6 Installation/mounting The intrinsically safe power supply and signal circuit between VEGADIS DIS61.CC/O**, DIS81. CC/O****** and the sensor should be mounted ungrounded. The required insulation voltage is > 500 V AC. 7 Installation Diagram VEGADIS81 + - VEGA SENSOR Associated Apparatus (Note 6) (Note 7) (Note 10) + - Control Equipment (Note 4) For XP-IS VERSION VEGA SENSOR VEGADIS81 + - VEGA SENSOR Comm. Port + Input - VEGADIS81 Entlty Parameters: Input: Vmax=6.4V, Imax=207.5mA, Pi=332mW, Li=0mH Associated Apparatus (Note 6) (Note 7) (Note 10) Control Equipment (Note 4) For IS VERSION VEGA SENSOR Comm. Port: Voc=7.5V, Isc=221.2mA, Po=0.415W Groups Capacitance Ca (uf) Inductance La (mh) IC / A, B IB / C, E IA / D, F, G 11.1 174 1000 0.7 3.0 5.7 Notes: The Intrinsic Safety Entity concept allows the interconnection of two CSA certified intrinsically safe devices with entity parameters not specifically examined in combination as a system when: U O or V OC or V t V max I O or I SC or I t I max P O P i C a or C O C cable L a or L O L cable For Division 2 installations, the Associated Appartus is required to be CSA Certified under Entity Concept if the VEGA-Sensor is installed in accordance with the Canadian Electrial Code, CSA C22.1 Part 1 Appendix F, for division 2 wiring methods excluding Nonincendive field wiring. Dust-tight conduit seal shall be used when installed in Class II and Class III enviroments. Control equipment connected to the Associated apparatus shall not use or generate more than 250 Vrms or Vdc. Division 1 installations should be in accordance with ANSI/ISA RP12.06.01 "Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations" and the Canadian Electrical Code under Entity Concept. The configuration of associated apparatus shall be CSA Certified under Entity Concept. VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** 5

Associated Apparatus manufacurer's installation drawing shall be followed when installing this equipment. The configuration of Field Device shall be CSA certified under Entity Concept. The Field Device manufacturer's installation drawing shall be followed when installing this equipment. VEGA Sensor is CSA certified for Class I, Zone 0, application. If connecting AEx ib Associated Apparatus or AEx ib I.S. Field Device to the VEGA Sensor the I.X circuit is only suitable for Class I, Zone 1, and is not suitable for Class I, Zone 0 or Class I, Division 1, Hazardous (Classified) Locations. No revision to dawing without prior Agency Approval. WARNING: Substitution of components may impair suitability for hazardous locations. If the Electrical parameters are unknown, the following values may be used: C cable = 60 pf/ft L cable = 0.20 µh/ft 8 Material resistance The VEGADIS DIS61.CC/O**, DIS81.CC/O****** must only be used in media against which the materials of the wetted parts are sufficiently resistant. 6 VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Notes VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** 7

Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 2015 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com