Gasfitter A Level 3 Rev. June 2011

Similar documents
Plumber Level 3 Rev. May 2011

Plumber A Guide to Course Content

Steamfitter-Pipefitter A Guide to Course Content

Refrigeration and Air Conditioning Mechanic (Residential) Level 2

Jr. Tech (JT-1, 2, 3) Knowledge Areas

Apprenticeship and Industry Training

Sprinkler System Installer Level 2

Page 1 of Relevant Provincial Jurisdictional legislation.

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

Revised April High School Graduation Years 2016, 2017, and Unit/Standard Number

DIRECTIVE NO: D-B

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

PLUMBING CURRICULA OUTLINE

ANNEXURE-A SPECIFICATIONS FOR HOT MIX PLANT

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

Apprenticeship and Industry Training

INDUSTRIAL MAINTENANCE E&I TECHNICIAN

ELECTRICAL CURRICULA OUTLINE CORE CURRICULUM 2015

Heating, Air Conditioning, Ventilation and Refrigeration Maintenance Technology/Technician CIP Task Grid

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

PHCC Educational Foundation Plumbing Year 4

WHEN TROUBLESHOOTING, PERFORM THE STEPS IN ORDER.

IE059: Boiler Control and Instrumentation for Engineers & Technicians

Recommended Work Keys Scores for Heating, Ventilating, and Air Conditioning

Improving the Performance and Reliability of Fired Heaters and Boilers

Apprenticeship and Industry Training

Apprenticeship and Industry Training

DIABLO VALLEY COLLEGE CATALOG

CLASS POWER ENGINEER S CERTIFICATE

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Sprinkler System Installer Level 1

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Fundamentals of HVAC/R 2010

The key element for your process

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

REGISTRATION EXAMINATION, NOVEMBER 2016 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

Entry Level Assessment Blueprint Electrical Construction Technology

FIFTH CLASS POWER ENGINEER S

Honeywell SLATE ICM Platform

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC)

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

HVACR Commercial Refrigeration

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Release: 1. UEE30811 Certificate III in Electrotechnology Electrician

7800 SERIES RM7888A Relay Module

Florida Department of Education Curriculum Framework

Air Conditioning and Refrigeration

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

HVA 140 RESIDENTIAL HEATING

7800 SERIES RM7888A Relay Module

Heating, Ventilation & Air Conditioning (HVAC)

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

MAGNUM MAX ASPHALT PLANTS

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT ELECTRICAL POWER AND TRANSMISSION INSTALLERS. Test Code: 5922 Version: 01

Sprinkler System Installer Level 3

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

Photo courtesy of U.S. Navy. ARID-Dry. Restoration and Construction Drying Equipment Mobile Desiccant Dehumidifiers Temporary Humidity Control

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

HG Million Btu/Hr Gas-Fired Heater

Geothermal Training System

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

Geothermal Training System (46126-A0)

Completed Projects / Projets terminés

HVACR Hydronic & Steam Systems

IE Code IE Competency Title Credit OAC Ref.

GAS TECHNICIAN. Program Outline

Operator: Save these instructions for future use!

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Options for Developing a Compliant PLC-based BMS

Apprenticeship Curriculum Standard. Electrician: Domestic & Rural. Levels 1 and 2. Trade Codes: 309C

OPERATING AND MAINTENANCE MANUAL

SETTING-UP SPEAKERS IN A RECTANGULAR ROOM

SECTION GAS-FIRED RADIANT HEATERS

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

7800 SERIES RM7840E,G,L,M Relay Module

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Direct Fired Heater Model AD Specification

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

SLATE. Integrated Combustion Equipment Management Success Stories

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Heating Maintenance and Repair

7800 SERIES EC7885A/RM7885A Relay Module

User s Information Manual

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

User s Information Manual

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

HVACR Refrigeration

Transcription:

Level 3

C1 B Level Requirements Update Duration: 35 hours 35 hours 0 hours As adult trade-learners, Gasfitter apprentices at all levels of skill-development are encouraged to use their eyes, ears, prior knowledge, and interpersonal skills to encourage journeypersons to teach as well as to supervise them. This requires understanding the trade s dynamics, including the roles and responsibilities that order jobsite activity taught to you previously. This unit content reviews the trade s skill-requirements and long-term career possibilities outlined in the previous levels. The unit s purpose is to review essential information about learning to learn as a Manitoba Gasfitter apprentice and prepare you for further learning. 1. Describe Gas Code. a. Review B licence requirements re B149.1 and B149.2 code changes and Manitoba 15% Gas Notices b. Review gas vent sizing (residential, commercial, industrial) 17% c. Review air supply (commercial, residential) 17% d. Review over piping and pipe sizing 17% e. Review fundamentals theory review 17% f. Review final layouts 17% 1

C2 Mathematics (includes gas trade formulas) Duration: 30 hours 30 hours 0 hours This unit of instruction is designed to provide the Gasfitter apprentice with the knowledge of imperial and metric systems, formulas and formula transposition, areas and volumes, elevations and grades, densities and pressures and offsets and percentages. 1. Describe math fundamentals (basic mathematics). 25% a. Identify and describe metric (s.i.) and imperial weights and measures, decimals and fractions, terms prefixes and relationships and Identify and describe formulas and formula transposition. b. Identify and describe the square root, perimeter and circumference. c. Identify and describe areas of rectangles, circles, triangles, trapezoids and surface areas. d. Identify and describe volumes of rectangular, cylindrical and irregular objects. e. Identify and describe Pythagora's theorem. f. Identify and describe special right angle triangles. g. Identify and describe grade: (simple, percentage, and cm/m). h. Identify and describe density, relative density and pressure in liquids and gases (kpa). i. Identify and describe parallel offsets. j. Identify and describe simple percentage, mark-up, net profit, gross profit. 2. Describe combustion mathematics (introduction). 25% 3. Describe speed, laws and sheave sizing. 25% 4. Describe gas pressure laws, Charle s, Boyle s and Universal. 25% 2

C3 Science Duration: 30 hours 30 hours 0 hours Upon completion of this unit of instruction apprentices will be able to show understanding of stoichiometrics, hermodynamics, and fan laws, and be able to relate same to gasfitting problems. 1. Describe stoichiometrics e.g., combustion mixture of air and fuel. 33% 2. Describe thermodynamics. 33% 3. Describe fan laws. 34% 3

C4 Electrical (Controls, Phasing, CE, Flame Safeguard Systems) Fundamentals and CE Code Duration: 80 hours 60 hours 20 hours Electrical theory is presented in a manner that is relevant and useful to the Class A Gasfitter. The apprentice will learn about electrical safety, symbols, wiring diagrams, transformers, protective devices, malfunctions, 1 phase and 3 phase motors, VFD drives, interactions of control devices, flame detection systems, non-programmable and programmable controls, limit controls, switches, interlocks, thermocouples, RTD s, thermistors, transducers, microprocessors, relay packages. This course will give the apprentice a basic knowledge of electrical sequence of operation of Industrial Gas Burner systems. 1. Describe electrical safety hazards and safe work practices. 4% 2. Describe common electrical symbols. 2% 3. Describe pictorial/wiring, ladder/schematic, and connection wiring diagrams. 2% 4. Describe power supplies from 1 phase and 3 phase transformers, line and load reactors. 5% 5. Describe protective devices fuses, circuit breakers, and overloads. 4% 6. Describe electrical malfunctions and describe troubleshooting, diagnose, and repair procedures. 7. Describe AC 1 Phase review and 3 phase motors, motor controls, and starting methods. 5% 8% 8. Describe variable frequency drives and volts/hertz relationship. 5% 9. Describe principles of electrical sequence of operation of Industrial Gas burner systems. 2% 10. Describe the interaction of mechanical and electrical control devices. 2% 11. Describe the function of flame detection systems flame rods, photo cells, infrared, and ultraviolet. 4% 4

12. Describe flame safeguard control systems sequences, terminology, and types of gas pilots. 3% 13. Describe non-programmable flame safeguard controls specific control functions. 5% 14. Describe programmable flame safeguard controls. 4% 15. Describe limit controls, switches, and interlocks. 3% 16. Describe thermocouples, RTD s, thermistors, and transducers. 3% 17. Describe microprocessor programmers. 5% 18. Describe hands on relay packages. 4% 19. Describe Canadian Electrical Code requirements. 6 % 20. Demonstrate programming and wiring of a variable frequency drive motor. 6% 21. Demonstrate wiring and testing of a programmed programmable logics controller. 6% 22. Demonstrate programming and wiring of boiler control. 6% 23. Demonstrate testing methods of flame detection systems flame rods, photo cells, infrared, and ultraviolet. 6% 5

C5 B149.3 Gas Codes and Manitoba Gas Notices Duration: 35 hours 35 hours 0 hours Gasfitters require a good, practical grasp of B149.3 Gas Codes and Manitoba Notices. 1. Describe the B149.3 Field Guide and the Manitoba Gas Notices. 50% 2. Describe layouts from section 149.3. 50% 6

C6 A Gas Fired Equipment Layout Duration: 9 hours 2 hours 7 hours Gasfitters require a good, practical grasp of the A gas fired equipment layout. Objectives and Content: Unit Mark (%) 1. Describe job layouts, permits, and equipment lists, etc. 22% 2. Demonstrate how to compile job profile including layouts. 39% 3. Demonstrate how to complete layouts, permits, specs, materials lists, for case study presented to student-apprentice up to pricing. 39% 7

C7 Boilers Duration: 20 hours 20 hours 0 hours This unit of instruction is designed to provide the Gasfitter apprentice with the knowledge and understanding of boilers. 1. Describe Boilers: a. Boiler design 15% b. Firing designs 15% c. Recognition of above 14% d. Burner systems as per above 14% e. Tests as per b52 14% f. Controls and safety 14% g. Boilers (water level equipment) 14% 8

C8 Air Make Ups Duration: 20 hours 15 hours 5 hours Upon completion of this unit of instruction apprentices will be able to show knowledge and understanding of air make ups. 1. Describe air make ups. 25% a. Basic Designs b. Sizing 2. Describe use of different designs. 25% 3. Describe how to test and commission designs. 25% 4. Demonstrate how to test and commission designs 25% 9

C9 Liquid Petroleum Products (LPGs) and Codes Duration: 35 hours 20 hours 15 hours This unit of instruction is designed to provide the Gasfitter apprentice with the knowledge and understanding of liquid petroleum products and Codes. 1. Describe LPGs. 57% a. Sizing of piping b. LP equipment required c. Best fitting practices d. Types of pumps, compressors e. Liquid meters f. Proper applications of above g. Vaporizers h. Mixers i. B149.5 gas code 2. Demonstrate LPG applications as per above. 43% 10

C10 Combustion Analysis Duration: 24 hours 14 hours 10 hours This unit of instruction is designed to provide the Gasfitter apprentice with the detailed knowledge and understanding of combustion analysis. 1. Describe combustion analysis. 46% a. Fundamentals b. Types of equipment c. Introduction to commercial and industrial realities d. Data logging systems e. Application to larger appliances 2. Demonstrate how to apply fundamentals to larger appliances. 42% 3. Describe expected results from different designs. 12% 11

C11 Other Gas Fired Equipment Duration: 14 hours 6 hours 8 hours This unit of instruction is designed to provide the Gasfitter apprentice with the knowledge and understanding of other gas fired equipment such as mine shaft heaters and grain dryers. 1. Describe the operation and mechanics of other gas fired equipment. 43% a. mine shaft heaters b. grain dryers c. Incinerators d. line burners 2. Demonstrate other gas fired equipment via field trip. 57% 12

C12 Troubleshooting Duration: 18 hours 11 hours 7 hours This unit of instruction is designed to provide the Gasfitter apprentice with the detailed knowledge and understanding of troubleshooting techniques and strategies. 1. Describe troubleshooting. 61% a. Describe analysis of systems b. Describe analysis of sequence of operation c. Interpret instrument readings 2. Demonstrate troubleshooting. 39% 13