Workshop on Energy Storage Systems and the Built Environment

Similar documents
FDNY Filing Procedures

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Research Needs for the Fire Safety Engineering Profession

TRANSMISSION AND DISTRIBUTION SUBSTATIONS

Smoke Management in High-Rise Structures

Report on First Revision June 2014 NFPA 5000

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

Chapter 3 FF II Fire Department Communications

IRC - BUILDING - ELECTRICAL - ELECTRICAL TAC

Structural Firefighting Policy

Energy Storage Systems Fire Safety Considerations. Howard Hopper, FPE Regulatory Services Program Manager

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Fire Protection Coffee Break Training May 2016

Firefighter Safety in Battery Energy Storage System Fires

DEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS

Executive Summary of Qualifications

University of Maryland FIRE EVACUATION PLAN

The Cannabis Industry: Fire Department Requirements

Battery Design Considerations

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

NATIONAL FIRE PROTECTION ASSOCIATION Fourth Survey of the Needs of the U. S. Fire Service

Performance Metrics for First Responder Locating/Tracking Technologies

Statue of Liberty: A Risk Analysis

LABC Gas Well Incident City Council Report

What are the Contents of an Effective Fire Safety Plan? Name: Date: Address of Project: Building Permit Number:

Prereq: FOD 131 or Instructor Permission

Fire Safety and Utility Controls. CERT Basic Training Unit 2

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Fire Service Considerations A Primer for Building and System Designers. Society of Fire Protection Engineers Fire Service Committee

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Public Safety Institute Fire & Rescue Course Fee Catalog

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

FIRE TECHNOLOGY (FIRE)

NEW ENERGY IN THE BATTERY INFRASTRUCTURE

Program of Instruction Course Syllabus

The 2012 Fire Suppression Rating Schedule (FSRS)

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

Health Care Engineers Fire & Life Safety Boot Camp

MNEC NFPA 72 WHITE PAPER

Battery Design Considerations

Fire Safety and Utility Controls. CERT Basic Training Unit 2

Protecting Backup Generators and UPS Systems Against Risk of Fire

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

CHAPTER 7 ALTERATIONS LEVEL

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Austin Independent School District Police Department Policy and Procedure Manual

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

This plan, its contents, and emergency notification procedures shall be made available to all appropriate university employees.

2018 International Fire Code. Add new text as follows:

OUTLINE FOR FIRE PREVENTION ACTIVITY

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

The Social Accountability International (SAI) Fire Safety Checklist

Li-ion Tamer Improved monitoring for lithium-ion battery health & safety. SUPDET ESS Design Challenge November 30 th, 2018

Extreme Fires!

OPWDD Fire Safety Level One Post Test

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

IMPLEMENTING RECOMMENDATIONS FROM THE ANGELLALA CREEK AMMONIUM NITRATE VEHICLE EXPLOSION

NFPA 45 NFPA 211 NFPA 1600

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

SEPTEMBER-NEWSLETTER-ELEVATOR DANGERS

Firefighting operations on fire control centres F5-09 GD

ANGELO STATE UNIVERSITY HAZARDOUS CHEMICAL STORAGE & SPILL CONTINGENCY PLAN

Laboratories and Hazardous Materials. Company Overview

Information Bulletin

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

SAGINAW FIRE DEPARTMENT SAFER

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

MODULE 8. Tying the Systems Together: Emergency Control Functions and Interfaces

SEMICONDUCTOR FABRICATION FACILITIES

FIRE/SMOKE BARRIER FUNDAMENTALS

Additional Materials: Instructor s PowerPoint, Question Files

Residential Fire Sprinkler Systems

Meeting Minutes. High Rise Building Safety Advisory Committee

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

Correctly Classifying and Determining Fire Protection Requirements for High- Hazard Group H Occupancies in New York State (2010 codes)

FIRE PROTECTION PROGRAM

SEMICONDUCTOR FABRICATION FACILITIES

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

<< COMPANY LETTERHEAD >>

NFPA Self Assessment Manual

Economic Impact of Building Regulations

PATTERNS OF FIREFIGHTER FIREGROUND INJURIES

Essentials of Fire Fighting 6 th Edition Firefighter I

IBC Committee Responsibility Matrix January 2017

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Chapter 18 Test. Directions: Write the correct letter on the blank before each question.

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Take your keys, coat, and any important information with you.

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

January 1, 2014 Mandatory Effective Date

Fire and Life Safety Review Form

Transcription:

Workshop on Energy Storage Systems and the Built Environment Presented by: Jack J. Murphy Fire Safety Directors Association of Greater New York 11/19/2015

Some highlighted Energy Storage System (ESS) concerns, considerations and national ICC/ESS Work Group Code Proposals that affect both Existing and New Construction Buildings.

A. Facility/Building Design Features: Unlike new construction where an ESS can be isolated at the roof level, on a separate floor remotely distance from any floor occupancy. Placing ESS in existing buildings create unique challenges such as: An ESS room could be placed throughout the building on many floors, sharing a separate enclosed Energy Storage System space within a MER/equipment room along with occupancy floors. An ICC ESS Work Group is currently developing code proposals: One is a Hazard Mitigation Analysis. With at least 6 to 7 various battery types from a Flow Battery to Valve Regulated Lead Acid (VRLA) Battery types and a mixture of a different battery type rack systems would create an adverse interaction of unknown toxic gas conditions with a greater risk to the life safety of occupants and firefighters.

A. Facility/Building Design Features: What is the limited ESS capacity per floor for an occupancy other than Group-H/High-Hazard, is it a 100, 500 or 1250 battery storage equivalency? With a potential ESS toxic off-gas release, will a building owner be required to have an Emergency Action Plan for decontamination? ICC Work Group Code Proposal: If placed within parking garage area, consideration against vehicle impact protection.

A. Facility/Building Design Features: Filing an ESS installation as a self-certification approval should not be applicable to this system, unless a Building Department checks and balance program is in place to identify when a selfcertification is at, or about to exceed the capacity limitations on a floor: Here is the rational: In one city there was a high-rise Group-B building that had a confirmed 60,000 to 80,000 gallons with estimation up to 120,000 gallons above the street level. By today s standard this building would be classified as a Group-H /High- Hazard Occupancy. All this came about by numerous un- restricted self-certifications. ESS wall separation no less than 2-hour masonry fire-rated barrier

A. Facility/Building Design Features: Any recycle ESS battery types should be prohibited, e.g., used hybrid vehicle batteries, etc. A dedicated ESS smoke control/purge system should be automatic to prevent toxic off-gases being released onto an occupied floor. This system must be separate from the building air handling system. Protect ESS room doors with an air-tight seal and a stepup containment barrier

B. Built-In Fire Protection Systems As of this date, the various types of ESS lack a proven fire extinguishment system. Review the current Fire Dept. B-29 Certificate of Fitness to be inclusive of any new ESS installations, processes and terminologies.

C. Emergency Response and Strategies & Tactics An ESS room, should have a camera surveillance capability with a connection to the building Fire Command Center. Besides posting building ESS warning signage to indicate the various specific hazards, provide the ESS hazardous data to fire dept. in a real time building intelligence solution so as to support initial operations through the mitigation efforts with a capability for citywide tracking. Providing a more robust decision based knowledge tool at the fingers tips of fire companies prior to arrival at an ESS incident, it can also further support a HazMat Unit advisory to the incoming fire units.

C. Emergency Response and Strategies & Tactics Explore new technologies that will provide the building fire safety director and first responders besides the location of an ESS incident, a method to quickly determine the severity of fire, predict excessive levels of hazardous off-gases as well as track and report floor occupant levels. The building environment, occupant locations, and building intelligence data can be streamed real-time to the building Fire Command Center. ICC Work Group Code Proposal: Risk Analysis Approval: If the ESS battery types are not specifically addressed in NFPA-13 Sprinkler System, the fire dept. must be permitted to approve the fire suppression system based on full scale fire and fault condition testing conducted by an approved laboratory.

In closing, while ESS is an evolving technology, the major challenge is a proven fire extinguishment system. We encourage the industry to conduct a fire and fault condition test, along with the thermal runaway condition associated with large battery installations as to provide a fire protection system for the specific Energy Storage System. Thank you, Be safe out there.