AudioCodes Routing Manager

Similar documents
Mediant 2600 E-SBC/Mediant 4000 and Mediant 9000 SBC and Software SBC Series

Managed Devices and Endpoints

Managed Devices and Endpoints

Managing Network Alarms and Events

Alarm setup and definitions in Cisco Unified Serviceability

Contact Product Manager, with details of the application.

Cisco CallManager. Management Module Guide. Document 5116

Making the Most of Alarms

Bosch TCU Integration Module Administrator's Guide

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

Managing Network Alarms and Events

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center System Integration Guide

Avigilon Control Center 5 System Integration Guide

Alarm Manager Plug-in

Lighting Xpert Insight User Manual

Monitor Alarms and Events

Common Alarms CHAPTER

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

RAy SNMP. Application notes.

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

Subscriber Data Management

Application Notes for Configuring NovaLink NovaAlert SIP with Avaya IP Office Issue 1.0

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Monitor Alarms and Events

Outdoor Temperature Sensor

Netbiter Tank Sensor

Using ANM Mobile CHAPTER

MultiSite Manager. Setup Guide

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

Experion LX Direct Station Specification

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Fault and Performance Management

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

UPS Battery Status (upsadvbatteryreplaceindicator, )

CAN unit for Analog Sensors

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

ETSI TS V8.2.0 ( ) Technical Specification

AXIS SNMP MIB. User Manual

Thresholding Configuration Guide, StarOS Release 16

HikCentral Web Client. User Manual

Avigilon Control Center System Integration Guide

Typical applications include the vibration detector. Detection of vibrations and shocks

HikCentral Web Client. User Manual

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

TX3 Series. TX3 Nano. Configuration Manual

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

LevelSET S GSM Functionalities Instructions for Commissioning and Use

Universal Monitoring System. TrapServer Description

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Perimeter Product Overview. Effective protection for your business

RFP Addendum 2 March 31, 2016

Before you install ProSeries software for network use

Gallagher Perimeter Product Overview

{jatabs type="content" position="top" width="600" mousetype="click" animtype="none" skipanim="false" duration=200}

Avigilon Control Center 5 System Integration Guide

Avaya Proactive Contact Release 5.x

IndigoVision Alarm Panel. User Guide

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

WHITE PAPER FEBRUARY Oracle Retail: Optimize Performance and Reduce Business Risk

Fike Safety y Technology Ltd

Ness acomms Install & User Manual

Rosenberger Intergrated Operation and Maintenance Center for all repeaters(2g/3g/lte) following CMCC and TMN specification.

UAS 7000 Local Management

General Specifications

Manage Alert Rules & Teams

Operating instructions V-ZUG-Home

OnGuard 7.2 Resolved Issues

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

USER S GUIDE. AXIS Cross Line Detection

Training Guide Series. CYMA User Portal Installation Guide

Alarm Management Implementation on a Plant. Standards Certification Education & Training Publishing Conferences & Exhibits

USER MANUAL CONTEG USER MANUAL. for the next decade! CONTEG SOLUTIONS. ...to complete your network. version: CONTEG, spol. s r.o.

Proliphix. Remote Management. User Guide

Instruction Manual Environmental Monitoring Unit with Output Relay

Ion Gateway Cellular Gateway and Wireless Sensors

RMS I DE 06 Rope Water Sensor

BMS MU Internet Ready Battery Management System Owners Guide

MULTISITE. Multisite Activation. Microsoft Dynamics AX White Paper

P2000 and Metasys System Integration

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Alarm module for leak detection with webserver

Temperature Monitoring System. Specifications

Andover ContinuumTM. SNMP Alarming

Home center Interface Server. Technical sheet

Harrier + Smart Controller & Chemical Management System

Electrolux Reseller FAQs

Before you install ProSeries Express Edition software for network use

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Moxa Proactive Monitoring User s Manual

Advanced Power Monitor (APM)

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

Getting Started with Live Exceptions

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

I can do WHAT? A look into Compass Viewers

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

Transcription:

Alarms Guide AudioCodes One Voice Operations Center AudioCodes Routing Manager Version 8.0

Alarms Guide Contents Contents 1 Introduction... 7 2 Alarms... 9 Version 8.0 3 ARM

Alarms List of Tables Table 1-1: Information Generally Included in Each Alarm... 7 Table 2-1: Operation Status Changed [Node]... 9 Table 2-2: Operation Status Changed [Peer Connection]... 10 Table 2-3: Operation Status Changed [Router]... 10 Table 2-4: Operation Status Changed [LDAP Server]... 11 Table 2-5: Configuration Inconsistency... 11 Table 2-6: Limit Reached... 12 Table 2-7: Disk Space Usage... 12 Table 2-8: ARM License Missing... 13 Table 2-9: ARM License Session Number... 13 Table 2-10: ARM License About to Expire... 14 Table 2-11: ARM License has Expired... 14 Table 2-12: Router Using Other Configurator... 14 Table 2-13: NTP Sync Status... 15 Table 2-14: ARM Quality Change... 15 Table 2-15: ARM Configurator Reload... 16 Alarms Guide 4 Document #: LTRT-42041

Alarms Guide Notice Notice Information contained in this document is believed to be accurate and reliable at the time of printing. However, due to ongoing product improvements and revisions, AudioCodes cannot guarantee accuracy of printed material after the Date Published nor can it accept responsibility for errors or omissions. Updates to this document can be downloaded from https://www.audiocodes.com/library/technical-documents. This document is subject to change without notice. Date Published: May-14-2018 WEEE EU Directive Pursuant to the WEEE EU Directive, electronic and electrical waste must not be disposed of with unsorted waste. Please contact your local recycling authority for disposal of this product. Customer Support Customer technical support and services are provided by AudioCodes or by an authorized AudioCodes Service Partner. For more information on how to buy technical support for AudioCodes products and for contact information, please visit our Web site at https://www.audiocodes.com/services-support/maintenance-and-support. Related Documentation Manual Name Mediant 500 MSBR User's Manual Mediant 500L MSBR User's Manual Mediant 500L Gateway and E-SBC User's Manual Mediant 800B Gateway and E-SBC User s Manual Mediant 800B MSBR User s Manual Mediant 1000B Gateway and E-SBC User s Manual Mediant 1000B MSBR User s Manual Mediant 2600 E-SBC User's Manual Mediant 3000 User s Manual Mediant 4000 SBC User's Manual Mediant 9000 SBC User's Manual Mediant Software SBC User's Manual One Voice Operations Center IOM Manual Version 8.0 5 ARM

Alarms Manual Name AudioCodes One Voice Operations Center Product One Voice Operations Center User s Manual IP Phone Management Server Administrator's Manual IP Phone Manager Express Administrator's Manual One Voice Operations Center Security Guidelines One Voice Operations Center Integration with Northbound Interfaces ARM User s Manual Document Revision Record LTRT 42040 Initial document release for Version 7.8 42041 Version 8.0. ARM Quality Change. ARM Configurator Reload. Documentation Feedback AudioCodes continually strives to produce high quality documentation. If you have any comments (suggestions or errors) regarding this document, please fill out the Documentation Feedback form on our Web site at http://online.audiocodes.com/doc-feedback.. Alarms Guide 6 Document #: LTRT-42041

Alarms Guide 1. Introduction 1 Introduction This Alarms Guide helps customer developers direct SNMP alarms to an application external to AudioCodes' ARM. The guide provides information about each alarm that can be displayed in the ARM GUI. Each alarm displayed generally includes the information shown in Table 1-1. Table 1-1: Information Generally Included in Each Alarm SNMP Trap OID SNMP Trap Name Alarm Type Alarm Source Alarm Textual description of the specific problem. Displayed from the variablebinding acarmtrapglobalstextual. NOTIFICATION-TYPE OID as it appears in the MIB. NOTIFICATION-TYPE Name as it appears in the MIB. Alarm type according to ITU X.733 definition. Displayed from the variable-binding acarmtrapglobalstype. Possible values of sources if applicable to a specific alarm. Displayed from the variable-binding acarmtrapglobalssource. Alarm probable cause according to ITU X.733 definition. Displayed from the variable-binding acarmtrapglobalsprobablecause. The level of the alarm's severity. Displayed from the variable-binding acarmtrapglobals. Additional information fields. Displayed from acarmtrapglobalsadditionalinfo1, acarmtrapglobalsadditionalinfo2 and acarmtrapglobalsadditionalinfo3. Possible corrective action when applicable. Version 8.0 7 ARM

Alarms This page is intentionally left blank. Alarms Guide 8 Document #: LTRT-42041

Alarms Guide 2. Alarms 2 Alarms This section describes the alarms that can be displayed in the ARM GUI. Table 2-1: Operation Status Changed [Node] The operative state of Node #elementname has changed to #status. 1.3.6.1.4.1.5003.9.70.1.2.2.0.1 acarmoperationstatuschanged Operation Status Changed Communications Alarm ElementType#ElementName/SubElementType#SubElementName Communications Subsystem Failure The alarm will be cleared once the status will be changed back to available. When this alarm is received from a Node and it indicates that the operative state of the Node has changed to Unavailable: Check device network connectivity Check the device's network connectivity to the ARM Configurator When the alarm indicates that the operative state of the Node has changed to Logout: Check the configuration of the device's ARM service. When the alarm indicates that the operative state of the Node has changed to Unrouteable: Check the device's network connectivity to the ARM routers Check the routers' status and availability Version 8.0 9 ARM

Alarms Table 2-2: Operation Status Changed [Peer Connection] The operative state of Peer Connection #elementname has changed to #status. 1.3.6.1.4.1.5003.9.70.1.2.2.0.1 acarmoperationstatuschanged Operation Status Changed Communications Alarm ElementType#ElementName/SubElementType#SubElementName Communications Subsystem Failure The alarm will be cleared once the status will be changed back to available. When this alarm is received from a Peer Connection and it indicates that the operative state of the Peer Connection has changed to Unavailable: Check the configuration of the related IPGroup in the specific device. Check the device's network connectivity to the configured Proxy IP associated with that IP Group. When the alarm indicates that the operative state of the Peer Connection has changed to Predeleted: Check that the configuration of the IP Group coincides with those configured in the ARM Configurator. Pay special attention to IPGroup Name and to parameter 'Used By Routing Server'. Table 2-3: Operation Status Changed [Router] The operative state of Router #elementname has changed to #status. 1.3.6.1.4.1.5003.9.70.1.2.2.0.1 acarmoperationstatuschanged Operation Status Changed Communications Alarm ElementType#ElementName/SubElementType#SubElementName Communications Subsystem Failure The alarm will be cleared once the status will be changed back to available. When this alarm is received from a Router and it indicates that the operative state of the Router has changed to Unavailable: Check the routers' status and availability. Alarms Guide 10 Document #: LTRT-42041

Alarms Guide 2. Alarms Table 2-4: Operation Status Changed [LDAP Server] The operative state of LDAP server #elementname has changed to #status. 1.3.6.1.4.1.5003.9.70.1.2.2.0.1 acarmoperationstatuschanged Operation Status Changed Communications Alarm ElementType#ElementName/SubElementType#SubElementName Communications Subsystem Failure The alarm will be cleared once the status will be changed back to available. When this alarm is received from an LDAP server and it indicates that the operative state of the LDAP server has changed to Unavailable: Check the LDAP server's network connectivity. Validate its credentials. Table 2-5: Configuration Inconsistency A configuration inconsistency was found with #SubElementType #SubElementName associated with #elementtype #elementname. 1.3.6.1.4.1.5003.9.70.1.2.1.0.1 - acarmconfigurationinconsistency Configuration Inconsistency Processing Error Alarm ElementType#ElementName/SubElementType#SubElementName Configuration or Customization Error Indeterminate ARM database was synchronized to the nodes configuration #SubElementType can be Peer Connection or Routing Interface. Connect to the device (SBC, gateway, etc.) and correct the configuration. Take into account that this alarm can also be generated if the Peer Connection SIP interface is by accident removed - or the name of the SIP interface or IP Group related to the ARM network element is changed. Version 8.0 11 ARM

Alarms Table 2-6: Limit Reached The number of users has exceeded the maximum allowed number (250000). 1.3.6.1.4.1.5003.9.70.1.2.2.0.2 - acarmlimitreached Limit reached Operational Violation Configurator/Users Threshold Crossed In the LDAP Server Settings page, use the 'Search filter' parameter to filter out unnecessary AD users from the ARM users table. See the User's Manual for more information. If you still face the same problem after optimizing using the search filter, contact your AudioCodes representative. Table 2-7: Disk Space Usage The usage size (in %) on the disk partition of the #application type #application name is Dangerously High or Almost Full. 1.3.6.1.4.1.5003.9.70.1.2.2.0.3 acarmdiskspaceusage Disk space usage Environmental Alarm #ARM or Router #Configurator or Router name Storage Capacity Problem Indeterminate #application type can be ARM or Router. Either: Purchase a larger disk Change the partition configuration Note: 'Dangerously high' is sent before 'Almost full' is sent 'Almost full' is sent when ARM functioning is at risk Immediate corrective action is required Alarms Guide 12 Document #: LTRT-42041

Alarms Guide 2. Alarms Table 2-8: ARM License Missing The ARM license is not found. 1.3.6.1.4.1.5003.9.70.1.2.2.0.10 acarmlicensemissing ARM License missing Operational Violation Configurator Key Expired Contact your AudioCodes representative Install an ARM license Table 2-9: ARM License Session Number The number of active sessions has exceeded #sessions% of the number allowed by the ARM license. 1.3.6.1.4.1.5003.9.70.1.2.2.0.9 acarmlicensesessionnumber ARM License session number Operational Violation Configurator Threshold Crossed Critical Contact your AudioCodes representative to update your ARM license. Version 8.0 13 ARM

Alarms Table 2-10: ARM License About to Expire The ARM license will expire in less than #number day/s. 1.3.6.1.4.1.5003.9.70.1.2.2.0.5 - acarmlicenseabouttoexpire ARM License about to expire Operational Violation Configurator Key Expired Contact your AudioCodes representative to update your ARM license. Table 2-11: ARM License has Expired The ARM license has expired. 1.3.6.1.4.1.5003.9.70.1.2.2.0.6 - acarmlicensehasexpired ARM License has expired Operational Violation Configurator Key Expired Critical Contact your AudioCodes representative to update your ARM license. Table 2-12: Router Using Other Configurator Router #RouterName is connected to the wrong Configurator. 1.3.6.1.4.1.5003.9.70.1.2.2.0.7- acarmrouterusingotherconfigurator Router Using other Configurator Operational Violation #Router #RouterName Denial Of Service Critical Contact your AudioCodes representative. Alarms Guide 14 Document #: LTRT-42041

Alarms Guide 2. Alarms Table 2-13: NTP Sync Status The clock on #applicationtype is #NTPstate with #NTPserverName. 1.3.6.1.4.1.5003.9.70.1.2.2.0.8 - acarmntpsyncstatus NTP sync status Time Domain Violation #ARM/Configurator #Router/RouterName TimingProblem #applicationtype can be ARM/Configurator or Router/Router name. The NTP clock is critical for ARM services. The clock impacts license, routing (time conditions), etc. Check the following: IP connectivity to the NTP server Firewall configuration NTP server configuration Table 2-14: ARM Quality Change The quality threshold of #elementtype #elementname was crossed. 1.3.6.1.4.1.5003.9.70.1.2.2.0.11 - acarmqualitychanged Quality threshold was crossed. Quality of Service Alarm #ARM/Configurator # elementtype / elementname Performance degraded #elementtype can be a Connection or a Peer Connection. Make sure quality thresholds are configured correctly in the ARM settings Contact your network administrator Contact your AudioCodes representative Version 8.0 15 ARM

Alarms Table 2-15: ARM Configurator Reload The quality threshold of #elementtype #elementname was crossed. 1.3.6.1.4.1.5003.9.70.1.2.2.0.12 - acarmtopologyreloaded ARM Configurator Reloaded operationalviolation ARM/Configurator Application subsystem failure Contact your AudioCodes representative Alarms Guide 16 Document #: LTRT-42041

Alarms Guide 2. Alarms This page is intentionally left blank. Version 8.0 17 ARM

International Headquarters 1 Hayarden Street, Airport City Lod 7019900, Israel Tel: +972-3-976-4000 Fax: +972-3-976-4040 AudioCodes Inc. 27 World s Fair Drive, Somerset, NJ 08873 Tel: +1-732-469-0880 Fax: +1-732-469-2298 Contact us: https://www.audiocodes.com/corporate/offices-worldwide Website: www.audiocodes.com 2018 AudioCodes Ltd. All rights reserved. AudioCodes, AC, HD VoIP, HD VoIP Sounds Better, IPmedia, Mediant, MediaPack, What s Inside Matters, OSN, SmartTAP, User Management Pack, VMAS, VoIPerfect, VoIPerfectHD, Your Gateway To VoIP, 3GX, VocaNom, AudioCodes One Voice and CloudBond are trademarks or registered trademarks of AudioCodes Limited. All other products or trademarks are property of their respective owners. Product specifications are subject to change without notice. Document #: LTRT-42041