Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Similar documents
Teledyne s Series IR7000 features excellent linearity and stability.

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

OPERATING INSTRUCTIONS FOR

Series 9000 Total Hydrocarbon Analyzer

INSTRUCTION, OPERATING, AND MAINTENANCE MANUAL FOR MODEL Special Version with Modifications for Automatic Background Gas Switching DANGER

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Oxygen Analyzer Manual

Toxic Gas Detection. Model F12. Toxic Gas Detection

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Series 5000 Hydrazine Analyzer Model 60002

A New Standard of Excellence

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Model D12-IR. Digital Gas Transmitter...

HFID Heated Total Hydrocarbon Analyzer Module

Process Gas Chromatograph

Dew-Point Transmitters and Instruments

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Model OEM-2 INSTRUCTIONS FOR USE

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

OPERATING INSTRUCTIONS FOR

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

PUV, PIR and PFO Series BROCHURE

Autocalibration Systems for In Situ Oxygen Analyzers

vacuum FLOW support excellence experience

OPERATING INSTRUCTIONS. Model 3010MB. Bulkhead Mount Control Unit, PN D Bulkhead Mount Analysis Unit, PN D DANGER

931D Style B Process Gas Chromatograph

Industrial Grade Gas Detection Detecting The Difference

APPLICATION DATA SHEET

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Mercury Vapor Monitor VM-3000

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

GPR-2600 Oxygen Analyzer

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

Trace Moisture Analyzer for Inert, Passive,Toxic, and Corrosive Gases

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Analog Room Pressure Monitor RPC Series

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Airflow Sensors Line Guide

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Low Temperature Zirconia Oxygen Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

MSA Fixed Gas & Flame Detection for the Automotive Industry

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

PureAire Combo O 2 / CO 2 Monitor

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Oxygen Sensing Solutions

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL

Hydrazine Analyzer Series 2171 Specifications

VM-3000 Mercury Vapor Monitor

Using the DewTrak II Dew Point/ Humidity Transmitter

Nov 08 PRODUCT SPECIFICATION SHEET

Teledyne Analytical Instruments. Oxygen Monitor System

Zareba Metro Gas Detector

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

02/11/2015

Airflow Sensors Line Guide

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

IAQ_100 C Package

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

APPLICATION DATA SHEET

Industrial Grade Gas Detection

02/11/2015

OPERATING INSTRUCTIONS. Model 3010PAC. Percent Oxygen Analyzer

Recent Improvements in Process GC Instrumentation

ENVAIR lab CO2 Tri-Gas Incubator

High Pressure Conductivity Monitor

Industrial Grade Gas Detection

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Air Check O 2 Deficiency Monitor 0-25%

HPLC Column Ovens and Temperature Controllers

SAM-MAX Refrigerant Monitors

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Transcription:

TELEDYNE Series 3300 Unaffected by hydrocarbons, H2, or CO2 Easy to handle, inexpensive, and easy to replace Can apply to ppb, ppm, and percent ranges Trace & Percent Oxygen Analyzers Fuel Cell Zirconium Oxide Paramagnetic Sensing Technologies The 3300 series of low cost, microprocessorbased instruments are specifically designed to satisfy industry s need for a simple yet highly reliable process analyzer. These unit offer excellent accuracy, ease of use, high reliability, low maintenance and a variety of standard features usually found on more expensive instruments. One Platform, Multiple Configurations The 3300 series is a cost-effective solution to many process applications. With three different sensing technologies to choose from and multiple design configurations, a customized unit for a given application is easily secured. Sensing ranges are varied based on the oxygen sensor and technology used. All units come with auto ranging capability and a 0-25% calibration range. Fully adjustable high or low concentration alarms provide the versatility to satisfy nearly any requirement. Sensing Technologies The 3300 Series is available with three sensing technologies, each with their own benefits. Micro-fuel Cell - 3300T, 3300P Disposable, no maintenance sensor design Specific to oxygen Linear from 0-100% O2 Absolute Zero (no O2, no output); single point calibration only Zirconium Oxide -- 3300Z Quick response time Long life / service on clean, non-corrosive streams No shelf life concerns Can be applied on a wide variety of applications Paramagnetic -- 3300M Long life / service in clean gas streams High accuracy Can be applied on corrosive, high temperature applications Fast response times (even on CO2 streams) Outputs for Data Transmission A standard 0-10 VDC output provides range identification, while the oxygen concentration is output through 4-20 madc negative ground and 0-10 VDC negative ground signals. An optional unidirectional RS-232 serial interface can be incorporated to relay information to a host computer for remote monitoring, making information and analysis results as close as a personal computer. Configurations (A) - 19 rack mount (B) - Wall mount enclosure Advantages Customer selectable ranges Auto ranging capabilities Fully adjustable high or low alarm setpoints with corresponding relay contacts Digital interface allows monitoring from a remote station Sensor failure alarm Options RS-232 serial interface for remote monitoring Built for reliability and performance

Series 3300 trace / percent Oxygen AnalyzerS series 3300 Trace / percent oxygen analyzers SPECIFICATIONS Ranges: 3300T 3300P 3300M 3300Z Two ranges with auto-ranging capability; field configurable between 0-10 ppm and 0-10,000 ppm 0-1 to 0-25% oxygen (0-3% and 0-10% default) Two ranges with auto-ranging capability; field configurable between 0-3% and 0-10% 0-10 ppm to 0-100% (user defined ranges) Calibration range: 0 to 25% O2 0 to 25% O2 0 to 25% O2 0 to 25% O2 Display: 4 digit LED 4 digit LED 4 digit LED 4 digit LED Accuracy: ±2% FS at constant temp, ±5% FS over operating temperature (once temperature equilibrium is reached). Higher accuracy is available for special configurations. Response time: 90% in less than 45 seconds at 77 F (25 C) 90% in less than 10 seconds at 77 F (25 C) 90% in less than 6 seconds at 77 F (25 C) Operating temp: 32-122 F (0-50 C); special temperature ranges available Signal output: For oxygen concentration: 4-20 madc negative ground and 0-10 VDC signals For range identification: 0-10 VDC signal Range ID: 0-10 VDC 0-10 VDC 0-10 VDC 0-10 VDC Alarm output: Two fully adjustable high or low alarms; one sensor fail relay (all alarms are fail-safe) Power Universal AC 85-265 VAC, 47-63 Hz requirements: Sampling system: Various options available. Contact factory. Connections: 1/4 inch or 6mm -- user specified Oxygen sensor: Micro-fuel Cell Micro-fuel Cell; Class I-22 Paramagnetic Zirconium oxide TELEDYNE A Teledyne Technologies Company 16830 Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: 626-934-1500 or 888-789-8168 FAX: 626-934-1651 EMAIL: ask_tai@teledyne.com www.teledyne-ai.com 2005 Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 09/05LD

Teledyne Analytical Instruments Model 3000ZA-XL The first amperometric based zirconium oxide analyzer for trace applications The sensor has been designed for enhanced performance on ranges from 0-5 ppm to 0-250 ppm. By focusing on this niche area of interest, the 3000ZA-XL provides the user with highly stable, drift-free performance. Zirconium Oxide Trace Oxygen Analyzer Teledyne manufactures a variety of oxygen analyzers utilizing state-of-the-art technologies to monitor oxygen in virtually all industrial bulk gases supplied by the air separation community. To compliment our electrochemical fuel cell and paramagnetic oxygen products, Teledyne has developed a zirconium oxide-based (ZrO2) trace oxygen analyzer, the 3000ZA-XL, which can be readily applied on inert, H2 / HC-free, gas streams. The unique, miniature, amperometric-based ZrO2 sensor provides the operator with unrivaled repeatability, responsiveness and stability. Proven Analyzer Platform By integrating Teledyne s amperometric ZrO2 oxygen sensor with our field-proven Series 3000 platform, the user achieves highly reliable control of their process. The 3000ZA-XL comes standard with (3) user programmable ranges, user selectable fixed or automatic range change capabilities, range ID contacts, two concentration output signals (current and voltage), a RS-232C bi-directional serial interface, two configurable concentration alarms, a system failure alarm, and user programmable auto-calibration capabilities. Designed for flush panel mounting, two units can be mounted sideby-side in a panel space-saving 19 rack arrangement. Sensing Technology The 3000ZA-XL utilizes a non-depleting amperometric zirconium oxide sensor. This miniature ZrO2 sensor generates a current signal linearly proportional to the part-per-million levels of oxygen present in the sample gas. The sensor also operates at a favorably lower operating temperature than conventional ZrO2 sensors providing a longer expected life of 5-plus years due to less thermal stress. In addition, Teledyne s amperometric ZrO2 sensor requires no reference gas supply, reducing installation and running costs as well as eliminating any inaccuracies associated with possible reference gas composition variances. Ideal for Unmanned Plant Operations Because the sensor has no reference gas requirements, operates on a non-depleting basis, and can easily be fitted with Teledyne s uniquely designed, electronically-driven, miniature integral auto-calibration valve manifold, it is an ideal choice for unmanned plant requirements. Key Features Highly flexible, field-proven Series 3000 platform Programmable Auto-Calibration capabilities User selectable ranges Helium leak checked sample handling system High sensitivity of 25 ppb or better Advantages No reference gas requirements = lower operating costs Long life, maintenance-free, non-depleting ZrO2 sensor design Highly stable, drift-free performance Low sensor replacement cost Applications Air liquefaction Inert gas blanketing Glove box monitoring Bulk gas purity certification Semiconductor manufacturing Note: The 3000ZA-XL should only be applied on inert sample gas streams which are ideally free of combustible gas impurities. For streams that may have trace levels of H2, CO, or hydrocarbons present, please consult with Teledyne in advance to address application feasibility considerations. Built for reliability and performance

3000ZA-XL ZIRCONIUM Oxide trace Oxygen Analyzer Standard Features Three user-selectable ranges Signal output: 0-1 VDC & 4-20 madc Programmable Auto Ranging Range ID contacts (Quantity 4). Form A normally open contacts, 3A resistive Two fully-adjustable concentration alarm points with programmable relay function. Form C contacts, 3A resistive Programmable auto cal / zero. Form A normally open contact relay signals Remotely initiated cal / zero via customer supplied 24 VDC signal Self diagnostics with Form C failure alarm contacts Full duplex RS-232 communication link Five digit oxygen concentration LED display Backlit 2 x 20 line alphanumeric liquid crystal display for set up and diagnostics 316 stainless steel sampling system Sample flow indicator Universal power supply: 85-230 VAC 50-60 Hz Specifications Ranges: Accuracy: Sensitivity: Response: Operating temp: Cross sensitivity: 3 ranges customer selectable (from 0-5 ppm to 0-25%)(optional low and optional high ranges available) ± 1% of FS at a constant temperature 0.5% of full scale 90% of FS at 77 F (25 C) < 30 seconds 32 to 122 F (0 to 50 C) Less than 0.5 ppm O2 with 5 ppm H2, 5 ppm CH4, or 5 ppm CO Signal output: Analytical measurement - 0-1 VDC, and 4-20 madc (isolated) Max. load impedance: Analysis display: Data lines: 4-20 ma isolated output 1000 ohms 5 digit red LED, 3/5 high numerals Bi-directional RS-232C serial interface Power requirements: Universal AC input ranges - 85 to 230 VAC, 50 / 60 Hz Max. power consumption: Oxygen sensor: Sample connections: Wetted parts: Area classifications: Mounting: Dimensions: 20 VA Zirconium oxide, amperometric type User specified 1/4 or 6 mm fittings Stainless steel and nylon General purpose Flush panel mount 8.70 W x 6.96 H x 12.2 D (case) 10.79 W x 7.46 H (panel) Options -C Auto cal / zero with integrally mounted control valves -K 19 rack mount with either one or two control units TELEDYNE A Teledyne Technologies Company 16830 Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: 626-934-1500 or 888-789-8168 FAX: 626-934-1651 EMAIL: ask_tai@teledyne.com www.teledyne-ai.com 2006 Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 01/06LD

Teledyne Analytical Instruments Models 3190 and 3290 Two programmable failsafe concentration alarms (one high and one low setpoint) provide the versatility to satisfy nearly any requirement. And because it s a Teledyne product, you can rely on many years of quality service. Trace & Percent Oxygen Analyzers Fuel Cell or Zirconium Oxide Sensors Good things come in small packages, and Teledyne s 3190 Trace or 3290 Percent Oxygen Analyzer proves it. These microprocessor based units offer high accuracy, easy use, and all the standard features demanded by the end-user in a compact, budget priced design. Membrane command switches and a large, four digit LED display make setup and operation clear and quick. For the latest technology, Teledyne quality, and an unbeatable value, the 3190 or 3290 provides a pocket-sized solution. Field-Configurable Range Options Depending on the application, these units can be configured to utilize one of Teledyne s patented, Micro-fuel Cell sensors or zirconium oxide sensors, assuring the highest accuracy. With a long expected sensor life, the 3190 or 3290 is as inexpensive to maintain as it is to purchase. Teledyne has even provided a sensor failure alarm, taking the worry and work out of the end-user s hands. Two ranges are field configurable on Model 3190 at 0-10 ppm and 0-1000 ppm with a 0-25% calibration range. Optional ranges can be set between 10 ppm and 10,000 ppm. The 3290 ranges are field configurable between 1% and 25% oxygen with 0-25% oxygen calibration. An optional full scale range is available up to 100%. Autoranging is standard on both models. Outputs For Data A standard 0-10 VDC output provides range identification, while the oxygen concentration is output through 4-20 madc negative ground and 0-10 VDC negative ground signals. An optional unidirectional RS-232 serial interface is incorporated to relay information to a host computer for remote monitoring of all functions. Configuration information and analysis results are as close as your personal computer. Advantages AutoRanging capabilities One high and one low alarm setpoint with corresponding relay contacts Sensor failure alarm Standard Features Two field configurable ranges plus cal range (0-25%) Signal output: 0-10 VDC for range identification Analytical output: 4-20 madc negative ground and 0-10 VDC signals Universal AC power supply (Optional configuration available) Optional Configurations - Power requirement: 10-36 VDC - Zirconium oxide sensor Applications Wave solder reflow ovens Glove box manufacturers Nitrogen membrane skids PSA skids Helium recovery systems Diving applications Clean air systems for medical applications Built for reliability and performance

3190 / 3290 trace / percent Oxygen AnalyzerS 3190 Trace 3290 Percent Ranges: 0-10 ppm and 0-1000 ppm and 0-25% calibration range (nominal) (user selectable percent ranges) (user selectable ranges can be set between 10 ppm and10,000 ppm) 0-3% and 0-10% oxygen (standard ranges) and 0-25% calibration range (nominal) (user selectable percent ranges) (user selectable ranges can be set between 1% and 25% O2) An optional 0-100% range is available. Display: LED LED Accuracy: ±1% of full scale at constant temperature ±2% of full scale at constant temperature; ±5% of full scale over operating temperature (once temperature equilibrium is reached; at 3% and higher user-defined ranges) Response time: 90% in less than 45 seconds at 25 C for fuel 90% in less than 10 seconds at 25 C cell, faster with a zirconium oxide sensor System operating temp: 0-50 C 0-50 C Signal output: 4-20 ma and 0-10 VDC negative ground, non-isolated Range identification: 0-10 VDC 0-10 VDC Alarm output: One high alarm relay, adjustable; One low alarm relay, adjustable; One sensor calibration fail relay (all alarms are failsafe) System power requirements: 10-36 VDC or 100V-240 VAC; 47-440 Hz, user specified Dimensions Panel mount: 2.81 H x 6 W x 2.87 D (71.4 x 152.4 x 72.9 mm) Oxygen sensor: Class B-2 (for ranges lower than 0-200 ppm) Class E-2 Optional: - Class A-2C for CO2 backgrounds - Zirconium oxide Optional: - Class A-5 for CO2 backgrounds - Zirconium oxide SP76 Compliant Oxygen Sensor Teledyne offers an SP76 compliant oxygen sensor for trace and percent ranges. SP76 is the Instrument Society of America s standard for sampling system components, which brings the following advantages: Substantially reduced size -- as compared to the alternative which requires discrete tubing cut and connected through fittings of various components, i.e. sensors, pressure regulators, valves, etc. A building block, plug-and-play approach that makes even the most inexperienced assembler or designer an immediate expert TELEDYNE A Teledyne Technologies Company 16830 Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: 626-934-1500 or 888-789-8168 FAX: 626-934-1651 EMAIL: ask_tai@teledyne.com www.teledyne-ai.com 2006 Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 1/06LD