TELEDYNE Series 3300 Unaffected by hydrocarbons, H2, or CO2 Easy to handle, inexpensive, and easy to replace Can apply to ppb, ppm, and percent ranges Trace & Percent Oxygen Analyzers Fuel Cell Zirconium Oxide Paramagnetic Sensing Technologies The 3300 series of low cost, microprocessorbased instruments are specifically designed to satisfy industry s need for a simple yet highly reliable process analyzer. These unit offer excellent accuracy, ease of use, high reliability, low maintenance and a variety of standard features usually found on more expensive instruments. One Platform, Multiple Configurations The 3300 series is a cost-effective solution to many process applications. With three different sensing technologies to choose from and multiple design configurations, a customized unit for a given application is easily secured. Sensing ranges are varied based on the oxygen sensor and technology used. All units come with auto ranging capability and a 0-25% calibration range. Fully adjustable high or low concentration alarms provide the versatility to satisfy nearly any requirement. Sensing Technologies The 3300 Series is available with three sensing technologies, each with their own benefits. Micro-fuel Cell - 3300T, 3300P Disposable, no maintenance sensor design Specific to oxygen Linear from 0-100% O2 Absolute Zero (no O2, no output); single point calibration only Zirconium Oxide -- 3300Z Quick response time Long life / service on clean, non-corrosive streams No shelf life concerns Can be applied on a wide variety of applications Paramagnetic -- 3300M Long life / service in clean gas streams High accuracy Can be applied on corrosive, high temperature applications Fast response times (even on CO2 streams) Outputs for Data Transmission A standard 0-10 VDC output provides range identification, while the oxygen concentration is output through 4-20 madc negative ground and 0-10 VDC negative ground signals. An optional unidirectional RS-232 serial interface can be incorporated to relay information to a host computer for remote monitoring, making information and analysis results as close as a personal computer. Configurations (A) - 19 rack mount (B) - Wall mount enclosure Advantages Customer selectable ranges Auto ranging capabilities Fully adjustable high or low alarm setpoints with corresponding relay contacts Digital interface allows monitoring from a remote station Sensor failure alarm Options RS-232 serial interface for remote monitoring Built for reliability and performance
Series 3300 trace / percent Oxygen AnalyzerS series 3300 Trace / percent oxygen analyzers SPECIFICATIONS Ranges: 3300T 3300P 3300M 3300Z Two ranges with auto-ranging capability; field configurable between 0-10 ppm and 0-10,000 ppm 0-1 to 0-25% oxygen (0-3% and 0-10% default) Two ranges with auto-ranging capability; field configurable between 0-3% and 0-10% 0-10 ppm to 0-100% (user defined ranges) Calibration range: 0 to 25% O2 0 to 25% O2 0 to 25% O2 0 to 25% O2 Display: 4 digit LED 4 digit LED 4 digit LED 4 digit LED Accuracy: ±2% FS at constant temp, ±5% FS over operating temperature (once temperature equilibrium is reached). Higher accuracy is available for special configurations. Response time: 90% in less than 45 seconds at 77 F (25 C) 90% in less than 10 seconds at 77 F (25 C) 90% in less than 6 seconds at 77 F (25 C) Operating temp: 32-122 F (0-50 C); special temperature ranges available Signal output: For oxygen concentration: 4-20 madc negative ground and 0-10 VDC signals For range identification: 0-10 VDC signal Range ID: 0-10 VDC 0-10 VDC 0-10 VDC 0-10 VDC Alarm output: Two fully adjustable high or low alarms; one sensor fail relay (all alarms are fail-safe) Power Universal AC 85-265 VAC, 47-63 Hz requirements: Sampling system: Various options available. Contact factory. Connections: 1/4 inch or 6mm -- user specified Oxygen sensor: Micro-fuel Cell Micro-fuel Cell; Class I-22 Paramagnetic Zirconium oxide TELEDYNE A Teledyne Technologies Company 16830 Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: 626-934-1500 or 888-789-8168 FAX: 626-934-1651 EMAIL: ask_tai@teledyne.com www.teledyne-ai.com 2005 Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 09/05LD
Teledyne Analytical Instruments Model 3000ZA-XL The first amperometric based zirconium oxide analyzer for trace applications The sensor has been designed for enhanced performance on ranges from 0-5 ppm to 0-250 ppm. By focusing on this niche area of interest, the 3000ZA-XL provides the user with highly stable, drift-free performance. Zirconium Oxide Trace Oxygen Analyzer Teledyne manufactures a variety of oxygen analyzers utilizing state-of-the-art technologies to monitor oxygen in virtually all industrial bulk gases supplied by the air separation community. To compliment our electrochemical fuel cell and paramagnetic oxygen products, Teledyne has developed a zirconium oxide-based (ZrO2) trace oxygen analyzer, the 3000ZA-XL, which can be readily applied on inert, H2 / HC-free, gas streams. The unique, miniature, amperometric-based ZrO2 sensor provides the operator with unrivaled repeatability, responsiveness and stability. Proven Analyzer Platform By integrating Teledyne s amperometric ZrO2 oxygen sensor with our field-proven Series 3000 platform, the user achieves highly reliable control of their process. The 3000ZA-XL comes standard with (3) user programmable ranges, user selectable fixed or automatic range change capabilities, range ID contacts, two concentration output signals (current and voltage), a RS-232C bi-directional serial interface, two configurable concentration alarms, a system failure alarm, and user programmable auto-calibration capabilities. Designed for flush panel mounting, two units can be mounted sideby-side in a panel space-saving 19 rack arrangement. Sensing Technology The 3000ZA-XL utilizes a non-depleting amperometric zirconium oxide sensor. This miniature ZrO2 sensor generates a current signal linearly proportional to the part-per-million levels of oxygen present in the sample gas. The sensor also operates at a favorably lower operating temperature than conventional ZrO2 sensors providing a longer expected life of 5-plus years due to less thermal stress. In addition, Teledyne s amperometric ZrO2 sensor requires no reference gas supply, reducing installation and running costs as well as eliminating any inaccuracies associated with possible reference gas composition variances. Ideal for Unmanned Plant Operations Because the sensor has no reference gas requirements, operates on a non-depleting basis, and can easily be fitted with Teledyne s uniquely designed, electronically-driven, miniature integral auto-calibration valve manifold, it is an ideal choice for unmanned plant requirements. Key Features Highly flexible, field-proven Series 3000 platform Programmable Auto-Calibration capabilities User selectable ranges Helium leak checked sample handling system High sensitivity of 25 ppb or better Advantages No reference gas requirements = lower operating costs Long life, maintenance-free, non-depleting ZrO2 sensor design Highly stable, drift-free performance Low sensor replacement cost Applications Air liquefaction Inert gas blanketing Glove box monitoring Bulk gas purity certification Semiconductor manufacturing Note: The 3000ZA-XL should only be applied on inert sample gas streams which are ideally free of combustible gas impurities. For streams that may have trace levels of H2, CO, or hydrocarbons present, please consult with Teledyne in advance to address application feasibility considerations. Built for reliability and performance
3000ZA-XL ZIRCONIUM Oxide trace Oxygen Analyzer Standard Features Three user-selectable ranges Signal output: 0-1 VDC & 4-20 madc Programmable Auto Ranging Range ID contacts (Quantity 4). Form A normally open contacts, 3A resistive Two fully-adjustable concentration alarm points with programmable relay function. Form C contacts, 3A resistive Programmable auto cal / zero. Form A normally open contact relay signals Remotely initiated cal / zero via customer supplied 24 VDC signal Self diagnostics with Form C failure alarm contacts Full duplex RS-232 communication link Five digit oxygen concentration LED display Backlit 2 x 20 line alphanumeric liquid crystal display for set up and diagnostics 316 stainless steel sampling system Sample flow indicator Universal power supply: 85-230 VAC 50-60 Hz Specifications Ranges: Accuracy: Sensitivity: Response: Operating temp: Cross sensitivity: 3 ranges customer selectable (from 0-5 ppm to 0-25%)(optional low and optional high ranges available) ± 1% of FS at a constant temperature 0.5% of full scale 90% of FS at 77 F (25 C) < 30 seconds 32 to 122 F (0 to 50 C) Less than 0.5 ppm O2 with 5 ppm H2, 5 ppm CH4, or 5 ppm CO Signal output: Analytical measurement - 0-1 VDC, and 4-20 madc (isolated) Max. load impedance: Analysis display: Data lines: 4-20 ma isolated output 1000 ohms 5 digit red LED, 3/5 high numerals Bi-directional RS-232C serial interface Power requirements: Universal AC input ranges - 85 to 230 VAC, 50 / 60 Hz Max. power consumption: Oxygen sensor: Sample connections: Wetted parts: Area classifications: Mounting: Dimensions: 20 VA Zirconium oxide, amperometric type User specified 1/4 or 6 mm fittings Stainless steel and nylon General purpose Flush panel mount 8.70 W x 6.96 H x 12.2 D (case) 10.79 W x 7.46 H (panel) Options -C Auto cal / zero with integrally mounted control valves -K 19 rack mount with either one or two control units TELEDYNE A Teledyne Technologies Company 16830 Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: 626-934-1500 or 888-789-8168 FAX: 626-934-1651 EMAIL: ask_tai@teledyne.com www.teledyne-ai.com 2006 Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 01/06LD
Teledyne Analytical Instruments Models 3190 and 3290 Two programmable failsafe concentration alarms (one high and one low setpoint) provide the versatility to satisfy nearly any requirement. And because it s a Teledyne product, you can rely on many years of quality service. Trace & Percent Oxygen Analyzers Fuel Cell or Zirconium Oxide Sensors Good things come in small packages, and Teledyne s 3190 Trace or 3290 Percent Oxygen Analyzer proves it. These microprocessor based units offer high accuracy, easy use, and all the standard features demanded by the end-user in a compact, budget priced design. Membrane command switches and a large, four digit LED display make setup and operation clear and quick. For the latest technology, Teledyne quality, and an unbeatable value, the 3190 or 3290 provides a pocket-sized solution. Field-Configurable Range Options Depending on the application, these units can be configured to utilize one of Teledyne s patented, Micro-fuel Cell sensors or zirconium oxide sensors, assuring the highest accuracy. With a long expected sensor life, the 3190 or 3290 is as inexpensive to maintain as it is to purchase. Teledyne has even provided a sensor failure alarm, taking the worry and work out of the end-user s hands. Two ranges are field configurable on Model 3190 at 0-10 ppm and 0-1000 ppm with a 0-25% calibration range. Optional ranges can be set between 10 ppm and 10,000 ppm. The 3290 ranges are field configurable between 1% and 25% oxygen with 0-25% oxygen calibration. An optional full scale range is available up to 100%. Autoranging is standard on both models. Outputs For Data A standard 0-10 VDC output provides range identification, while the oxygen concentration is output through 4-20 madc negative ground and 0-10 VDC negative ground signals. An optional unidirectional RS-232 serial interface is incorporated to relay information to a host computer for remote monitoring of all functions. Configuration information and analysis results are as close as your personal computer. Advantages AutoRanging capabilities One high and one low alarm setpoint with corresponding relay contacts Sensor failure alarm Standard Features Two field configurable ranges plus cal range (0-25%) Signal output: 0-10 VDC for range identification Analytical output: 4-20 madc negative ground and 0-10 VDC signals Universal AC power supply (Optional configuration available) Optional Configurations - Power requirement: 10-36 VDC - Zirconium oxide sensor Applications Wave solder reflow ovens Glove box manufacturers Nitrogen membrane skids PSA skids Helium recovery systems Diving applications Clean air systems for medical applications Built for reliability and performance
3190 / 3290 trace / percent Oxygen AnalyzerS 3190 Trace 3290 Percent Ranges: 0-10 ppm and 0-1000 ppm and 0-25% calibration range (nominal) (user selectable percent ranges) (user selectable ranges can be set between 10 ppm and10,000 ppm) 0-3% and 0-10% oxygen (standard ranges) and 0-25% calibration range (nominal) (user selectable percent ranges) (user selectable ranges can be set between 1% and 25% O2) An optional 0-100% range is available. Display: LED LED Accuracy: ±1% of full scale at constant temperature ±2% of full scale at constant temperature; ±5% of full scale over operating temperature (once temperature equilibrium is reached; at 3% and higher user-defined ranges) Response time: 90% in less than 45 seconds at 25 C for fuel 90% in less than 10 seconds at 25 C cell, faster with a zirconium oxide sensor System operating temp: 0-50 C 0-50 C Signal output: 4-20 ma and 0-10 VDC negative ground, non-isolated Range identification: 0-10 VDC 0-10 VDC Alarm output: One high alarm relay, adjustable; One low alarm relay, adjustable; One sensor calibration fail relay (all alarms are failsafe) System power requirements: 10-36 VDC or 100V-240 VAC; 47-440 Hz, user specified Dimensions Panel mount: 2.81 H x 6 W x 2.87 D (71.4 x 152.4 x 72.9 mm) Oxygen sensor: Class B-2 (for ranges lower than 0-200 ppm) Class E-2 Optional: - Class A-2C for CO2 backgrounds - Zirconium oxide Optional: - Class A-5 for CO2 backgrounds - Zirconium oxide SP76 Compliant Oxygen Sensor Teledyne offers an SP76 compliant oxygen sensor for trace and percent ranges. SP76 is the Instrument Society of America s standard for sampling system components, which brings the following advantages: Substantially reduced size -- as compared to the alternative which requires discrete tubing cut and connected through fittings of various components, i.e. sensors, pressure regulators, valves, etc. A building block, plug-and-play approach that makes even the most inexperienced assembler or designer an immediate expert TELEDYNE A Teledyne Technologies Company 16830 Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: 626-934-1500 or 888-789-8168 FAX: 626-934-1651 EMAIL: ask_tai@teledyne.com www.teledyne-ai.com 2006 Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 1/06LD