Valve Position Indicator VPX Series Issue E. Datasheet

Similar documents
MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH BX/BX2 Series

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

MICRO SWITCH Safety Limit Switches for Hazardous Locations GSX Series Issue 3. Datasheet

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Guide to Hazardous Location Approvals:

MICRO SWITCH GSX Series

MICRO SWITCH BAF/DTF Series

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

V-Basic Standard V15 Series

MICRO SWITCH E6/V6 Series

MICRO SWITCH NT Series

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

MICRO SWITCH NT Series

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

MICRO SWITCH GLL Series

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Sensors and Switches in Commercial Traction Elevators

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

MICRO SWITCH Cable-Pull Safety Switches CPS Series Issue 3. Datasheet FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS

Quadrature Speed and Direction Sensors

Wireless Panel-Mount Monitor

How Limit Switches Can Stop Machines from Going Boom

Installation Instructions for the 600 Series Optical Encoders

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

MICRO SWITCH V15W Series Watertight Miniature Switches

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Installation Instructions for the

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

HOA6480 Series Barcode Sensor Infrared Products

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Intrinsically Safe Transmitters, Option Code 2n

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

HIH-4000 Series Humidity Sensors

Wireless Heavy-Duty Limit Switch with Eyelet-Pull (WLS Series)

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

General Purpose Industrial VRS Magnetic Speed Sensors

Sensor Evaluation Kit, SEK001

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

High Temperature Industrial VRS Magnetic Speed Sensors

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

HIH-4602-L Series Humidity Sensors

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

FSS-SMT Series. Low Profile Force Sensor

FEATURES AND BENEFITS

Installation Instructions for the

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

MICRO SWITCH Limit Switches Line Guide

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

HIH-5030/5031 Series Low Voltage Humidity Sensors

Micropower Omnipolar Digital Hall-Effect Sensor ICs

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION


Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

MICRO SWITCH Sealed and High Accuracy Switch Line Guide

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

MICRO SWITCH Basic Switches Line Guide

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

Potential Applications

Linear Current Sensors

Limitless Wireless Din-Rail Receiver. WDRR Series. Datasheet

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

HFX Fiber Optic Component 50 Mbps, 650 nm LED

AMR 4-Pin Quadrature Sensor Integrated Circuit

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HIH-4030/31 Series Humidity Sensors

Transportation Attitude Reference System (TARS Series) Ruggedized Inertial Measurement Unit (IMU) Issue 2. Datasheet

Transportation Attitude Reference Sensor (TARS Series) Ruggedized Inertial Measurement Unit (IMU)

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

Inductive slot sensor

HIH-4010/4020/4021 Series Humidity Sensors

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

MICRO SWITCH Basic Switches Line Guide

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-T3 SS460S-LP

Technical Data. General specifications. Rated operating distance s n 5 mm

WARNING MISUSE OF DOCUMENTATION

Worcester Controls PS/PM Series UltraSwitch. Switchbox

Heavy Duty Pressure Transducers

Transcription:

Valve Position VPX Series DESCRIPTION Valve Position, VPX Series switches are built especially for outdoor use in potentially hazardous atmospheres. The switch enclosures are constructed to withstand the pressure of an internal explosion. Flame paths cool the exploded gases to a point less than the lowest safe operating temperature of the surrounding gas. The VPX Series versions equipped with the inductive proximity switches has the Intrinsically Safe (IS) rating. Regardless of where the equipment or machinery is designed, built or installed, the VPX Series products carry global agency coverage. The VPX Series switches have standard rugged die-cast aluminum housing. The products housing is weather sealed for outdoor use and comply with NEMA 4X requirement for protection against corrosion, in addition to various NEMA enclosure standards. The product s o-ring seals make the enclosure rain tight, but are outside of required flame paths so explosion proof requirements are maintained. The VPX Series switches are available in multiple colors and angles, visible from all directions. Unless special ordered, all basic switches operate on clockwise and counterclockwise rotation. DIFFERENTIATION With numerous environmental ratings (Ingress Protection and NEMA), the VPX Series is protected for all kinds of outdoor conditions VPX Series is certified flame-proof, explosion-proof and Intrinsically Safe (optional), thereby making the product safe for a wide variety of potentially hazardous area applications The Safety Integrity Level, SIL 3 certification, puts the VPX Series in the higher safety category as compared to its competitors Datasheet FEATURES VPX Series switches are certified for ATEX, IEC Ex, CE, culus, NEPSI, and KOSHA specifications for global applications that requires protection from explosive gases, vapors & combustible dust Die-cast aluminum housing and various sealing (NEMA 4, 4X, 6, and 13), certifies the VPX Series is rated for rain, wind, snow, ice and blowing dust environments Wide operating temperature range from -40 C to 80 C (see Table 1 for detailed specifications) Versions of the VPX with proximity switches carry an Intrinsically Safe (IS) rating Well suited for up to 500,000 actuation cycles Available in multiple indicator colors that is visible from all directions VALUE TO CUSTOMERS culus, ATEX, IEC EX, NEPSI, and KOSHA certified for hazardous (explosive) environments Designed with the end user in mind, these switches help to create user-friendly interfaces with broad applications possibilities to help meet the challenges of many different environments Weather sealed to NEMA and IP ratings Reliable, dependable and accurate Versions available in both snap-action switches and intrinsically safe inductive proximity switches POTENTIAL APPLICATIONS Seaside grain and duel loading docks Oil and gas wells Refineries Fuel storage facilities Mining Petrochemical and chemical plants Waste water treatment facilities Oil and gas production pipeline networks Paint batching/blending plants Pharmaceuticals and drug processing plants Food and beverage industries Pesticides manufacturing plants Textile dyeing and finishing plants Lead acid battery manufacturing facilities 32321149 Issue E PORTFOLIO The VPX Series joins the CX Series of valve position indicator switches for hazardous areas applications. The standard offerings of the VPX Series is certified for flammable gases, vapors and combustible dust. The VPX Series also offers the Intrinsically Safe versions (optional). To view the entire product portfolio, click here. Sensing and Internet of Things

Table 1. Specifications Characteristic Parameter Series name VPX Series Product type Housing material Housing size Operating temperature Sealing Agency approvals Valve Position Aluminum with protective paint finish 152,3 mm H x 140 mm W x 140 mm D [6.0 in H x 5.5 in W x 5.5 in D] ref. Versions with four electromechanical switches: -40 C to 50 C [-40 F to 122 F] Versions with two electromechanical switches: -40 C to 60 C [-40 F to 140 F] Versions with proximity switches: -40 C to 80 C [-40 F to 176 F] NEMA 4, 4X, 6, and 13 per UL 50E; IP66 per IEC 60079-0; IP67 per IEC 60529 (self-certified by Honeywell) culus, ATEX, IEC EX, CE, NEPSI, KOSHA Explosion proof hazardous area designations Intrinsically safe hazardous area designations Visual indicator Electrical ratings Mechanical endurance Safety Integration Level (SIL) Shock Vibration Product weight North America: Division 1, Class I, Groups B, C, and D (Gas Rating) Division 1, Class II, Groups E, F, and G (Dust Rating) ATEX/IEC Ex: II 2 G, II 2 D (ATEX Rating) Ex db IIC T6 Gb (Gas Rating) Ex tb IIIC T85 C Db (Dust Rating) Ta -40 C to +50 C (Switch Code 4A or 4B) Ta -40 C to +60 C (Switch Code 2A or 2B) Versions of the VPX with proximity switches carry an intrinsically safe rating: North America: Not Available ATEX/IEC Ex: II 1 G, II 1 D (ATEX Rating) Ex ia IIC T4 Ga (Gas Rating) Ex ia IIIC T135 C Da (Dust Rating) Ta -40 C to 80 C Available in multiple colors and angles. Visible from all directions. Versions with snap-action switches: UL Rating: 15 A 150 Vac CE Rating: 16 A 250 Vac 10 A 250 Vac 0.5 A 250 Vdc 0.5 A 250 Vdc Versions with Intrinsically Safe Proximity Switches: Switch element function: NAMUR, NC Nominal voltage: 8.2 V Current consumption (On) 1 ma Current consumption (Off) 3 ma 500,000 cycles min. SIL 3 per IEC 61508-2. The Mean Cycle to Failure (MCTF) requirements are: Mechanical endurance MCTF: 500,000 cycles Electrical endurance MCTF proximity switches: 50,000 cycles Electrical endurance MCTF electromechanical switches loaded at 16 A 250 Vac: 25,000 cycles Electrical endurance MCTF electromechanical switches loaded at 0.5 A 250 Vdc: 10,000 cycles IEC 60068-2-27; half sine, 50 g, 11 ms, 3 axis IEC 60068-2-6; 10 Hz to 59 Hz with 1,5 mm peak-to-peak, 60 Hz to 500 Hz @ 5 g, 7.5 min sweeps, 20 sweeps per axis 2,4 kg [5.2 lb] (approx.) 2 sensing.honeywell.com

Figure 1. Product Nomenclature VPX 1 C 2A A GR 1 A 2A 1 Series VPX Series Valve Position Enclosure Material 1 Aluminum A Origin and Certifications China (standard) IEC Ex, ATEX, CE, NEPSI China (premium) C IEC Ex, ATEX, culus, CE, SIL3, NEPSI, KOSHA E USA (premium) IEC Ex, ATEX, culus, CE, SIL3, NEPSI, KOSHA 2A 4A Switch Options 2X snap action SPDT 4X snap action SPDT 2X snap action 2B SPDT, gold contacts 4X snap action 4B SPDT, gold contacts 2X I.S. inductive 2C proximity switch (Namur) Angle A 45 B 90 GR BY YB RY GY RG YR YG Color Green (open) Red (closed) Black (open) Yellow (closed) Yellow (open) Black (closed) Red (open) Yellow (closed) Green (open) Yellow (closed) Red (open) Green (closed) Yellow (open) Red (closed) Yellow (open) Green (closed) 1 Namur 2 End 1/4 in flats 3 Ø7.25 knurl for ex. lever Rotation A 360 continuous B ±90 2A 2B 2C 2D 3B 4C 4D 4F Entry (2) 1/2-14 NPT (A & D) (2) 3/4-14 NPT (A & D) (2) M20 x 1.5 (A & D) (2) M25 x 1.5 (A & D) (3) 3/4-14 NPT (A, B, & D) (4) M20 x 1.5 (4) M25 x 1.5 (2) 1/2-14 NPT (B & D) & (2) 3/4-14 NPT (A & D) Number of Plugs 1 Leave blank for no plugs 1 plug 2 2 plugs 3 3 plugs Indicate how many plugs should be included. Any unused conduit entries must be sealed with a blanking element certified to the hazardous location environment (or better). Plugs can also be purchased separately. (see page 7). Specials Up to two letters or numbers to indicate a special feature. Table 2. Operating Characteristics Characteristic Operating torque Operating point Factory set points for 4-switch option Factory set points for 2-switch option Parameter 1,0 Nm [8.9 in-lb] max. Adjustable to any angle in 4 increments Switches 1 & 2: 25 ±25 when the shaft is rotated clockwise Switches 3 & 4 (45 indicator): 45 ±25 when the shaft is rotated counterclockwise Switches 3 & 4 (90 indicator): 90 ±25 when the shaft is rotated counterclockwise Switch 1: 25 ±25 when the shaft is rotated clockwise Switch 2 (45 indicator): 45 ±25 when the shaft is rotated counterclockwise Switch 2 (90 indicator): 90 ±25 when the shaft is rotated counterclockwise Sensing and Internet of Things 3

Table 4. Order Guide Assembly Location Temperature Rating Temperature Class Hazardous Location Approvals Switch Options Angle Color Rotation Catalog Listing China USA -40 C to 50 C -40 C to 60 C -40 C to 80 C T6 T4 IEC Ex ATEX culus KOSHA NEPSI VPX1C2ABGR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü 2X snap action VPX1C2ABGR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü 4X snap action VPX1C4ABYR1A3B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2CBGR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2CBGR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2ABYR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2ABYR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C4ABGR1A3B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2CBYR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2CBYR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü 2X I.S. Prox Gold-plated contacts VPX1C2ABGR1A4F ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2ABYR1A4F ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2CBGR1A4F ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C2ABYB1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1C4ABGR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABYB1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABYB1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABBY1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABYB1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABGR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABRG1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABBY2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABYB2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABGR2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABRG2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü 45 90 Green/Red Black/Yellow Red/Yellow Green/Yellow NAMUR 1/4 in flats Knurl 360 ±90 (2) 1/2-14 NPT (A&D) (2) 3/4-14 NPT (A&D) (2) M20 x 1.5 (A&D) (2) M25 x 1.5 (A&D) (3) 3/4-14 NPT (A,B&D) (4) M20 x 1.5 (4) M25 x 1.5 (2) 1/2-14 & (2) 3/4-14 4 sensing.honeywell.com

Assembly Location Temperature Rating Temperature Class Hazardous Location Approvals Switch Options Angle Color Rotation Catalog Listing China USA -40 C to 50 C -40 C to 60 C -40 C to 80 C T6 T4 IEC Ex ATEX culus KOSHA NEPSI 2X snap action VPX1E2ABBY3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABYB3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABGR3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2ABRG3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABBY1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABGR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABRG1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABBY2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABYB2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABGR2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABRG2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABBY3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABYB3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABGR3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E4ABRG3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2BBYB3B2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü VPX1E2CBYB1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü 4X snap action 2X I.S. Prox Gold-plated contacts 45 90 Green/Red Black/Yellow Red/Yellow Green/Yellow NAMUR 1/4 in flats Knurl 360 ±90 (2) 1/2-14 NPT (A&D) (2) 3/4-14 NPT (A&D) (2) M20 x 1.5 (A&D) (2) M25 x 1.5 (A&D) (3) 3/4-14 NPT (A,B&D) (4) M20 x 1.5 (4) M25 x 1.5 (2) 1/2-14 & (2) 3/4-14 Sensing and Internet of Things 5

Figure 2. Mounting Dimensions Ø 105,8 [Ø 4.16] 75 [3.0] min. to remove cover CLOSED 95,8 [3.77] 29,0 [1.14] 52,0 [2.05] 65,0 [2.56] 4,5 [0.18] 2 X 32,5 [1.28] Position B Position C Position A Position D 57,15 [2.25] 35,36 [1.392] 140,0 [5.51] 4 X M6 x 1 8 4 X M8 x 1.25 8 57,15 [2.25] 140,0 [5.51] 35,36 [1.392] 6 sensing.honeywell.com

ACCESSORIES A mounting bracket kit is available as an accessory, Honeywell part number VPZB1. Figure 3. Accessory Bracket 80,0 [3.15] 30,0 [1.18] 130,0 [5.12] 30,0 [1.18] 47 ±10 [1.8 ±0.3] 47 ±10 [1.8 ±0.3] Table 5. Plug Accessories Size Honeywell Part Number Tightening Specification 1/2-14 NPT VPZPA Hand tight and then 1 to 2 full turns using a wrench 3/4-14 NPT VPZPB Hand tight and then 1 to 2 full turns using a wrench M20 x 1.5 VPZPC Hand tight and then 1/4 to 1 full turn using a wrench M25 x 1.5 VPZPD Hand tight and then 1/4 to 1 full turn using a wrench Sensing and Internet of Things 7

Table 6. Lever Actuator Accessories Lever Listing Description LSZ51 Fixed, rollerless (1.5 R) LSZ51A Fixed, 0.75 in x 0.25 in nylon roller, open (1.5 R) LSZ51C Fixed, 0.75 in x 0.25 in nylon roller, closed (1.5 R) LSZ52C Adjustable, 0.75 in x 0.25 in nylon roller, closed LSZ52J Adjustable, 1.0 in x 0.5 in nylon roller, closed LSZ52K Adjustable, 1.25 in x 0.25 in nylon roller, closed LSZ53E Yoke, 0.75 in x 0.25 in nylon rollers, closed & open LSZ53S Yoke, 0.75 in x 0.25 in nylon rollers, same side closed LSZ54 Hub only LSZ54M Hub, aluminum rod actuator LSZ55 Offset lever, rollerless LSZ55A Offset, 0.75 in x 0.25 in nylon roller, open LSZ55C Offset, 0.75 in x 0.25 in nylon roller, closed LSZ59A Fixed, 0.75 in x 0.25 in nylon roller, open (1.33 R) LSZ59C Fixed, 0.75 in x 0.25 in nylon roller, closed (1.33 R) 8 sensing.honeywell.com

ADDITIONAL MATERIALS The following associated literature is available at sensing.honeywell.com: Product range guide Installation instructions Application note m WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. m WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell s sensing and switching products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 honeywell.com 32321149-E-EN IL50 GLO November 2018 2018 Honeywell International Inc. All rights reserved.