AHU with heat recovery exchanger. AHU is used for ventilation of houses and other heated areas. Stouch and TPC remote control devices. 7040..0 housing: powder coated painting RAL - PASS. sami - montowane na kanale). - Flex, Stouch, TPC. Accessories Control panel Sensor controller Programmable controller Circular duct silencer Shuft-off damper Mounting clamp Heating coil Flex p. 178 Stouch p. 179 TPC p. 180 AKS p. 20 SKG p. 226 AP p. 229 AVS p. 192 80
RIS 260 Air intake side (L - left; R - right) Heater type (E - integrated electrical heater; W - optional water heater) AHU with plate heat-exchanger /h Type Type Flex Stouch TPC *** - anti-frost thermostat int - already integrated into the unit Dimensions [mm] L W H ød H 1 F 295 598 680 125-0 52 900 800 160-0 462 950 845 200-0 645 1400 1000 15 70 40 645 1400 1000 15 70 40 790 1650 1100 400 70 65 AKS SKG AP Accessories AVS SP TJP 10K CO4C*** SSB Heating RMG 80/60 0 C RMG 60/40 0 C VVP/VXP 80/60 0 C + 125 - LM20A-TP - - - - - - VVP/VXP 60/40 0 C + 125 125 TF20 + 81-0,6-4 -0,6-4 45.10-0,6 45.10-0,6 + 160 - LM20A-TP - - - - - - + 160 160 TF20 + 81-0,6-4 -0,6-4 45.10-0,6 45.10-0,6 + 200 - LM20A-TP - - - - - - + 200 200 TF20 + 81-0,6-4 -0,6-4 45.10-0,6 45.10-0,6 + 15 - LM20A-TP - - - - - - + 15 int LF20 int 81-1,0-4 -0,6-4 45.10-1,0 45.10-0,6 + 15 - LM20A-TP - - - - - - + 15 int LF20 int 81-1,0-4 -0,6-4 45.10-1,0 45,10-0,6 + 400 - SM20A-TP - - - - - - + 400 int SF20A int 81-1,6-4 -1,0-4 45.10-1,6 45.10-1,0 Accessories Actuator for dampers Duct sensor Thermic water valve actuator Mixing point 2 and - way valves SP p. 188 TJP 10K p. 187 SSB p. 184 RMG p. 185 VVP/VXP p. 186 81
Static pressure [Pa] îè ëê èí ïïï ïíç ïêé ïçì îîî RIS 260VE.0 RIS 400VE.0 RIS 700VE.0 RIS 260VE.0 RIS 400VE.0 RIS 700VE.0 Extract air = 20 C/60%RH Outdoor air = -20 C 260VE.0 400VE.0 700VE.0 Heater -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power consumption [kw] 1,0 2,0,0 Pre-heater for heat exchanger [kw] 0, 1,0 1,2 Fans -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power/current [kw/a] 0,075/0, 0,207/0,91 0,205/0,89 -fan speed [min -1 ] 1880 2100 2000 -power/current [kw/a] 0,080/0,5 0,198/0,87 0,20/0,88 -fan speed [min -1 ] 1880 1850 2000 Motor protection class IP-44 IP-44 IP-54 55% 60% 60% Max power consumption [kw/a] 1,455/6,,40/14,9 4,71/20,5 Automatic control integrated integrated integrated Filter class - G4 G4 G4 M5 M5 M5 Thermal insulation [mm] 20 0 0 Weight [kg] 40,0 68,0 82,0 Comply with ERP 201 + + + Designed for operation indoors only RIS 260VEL.0 Air intake side (L - left) RIS 400VEL.0 Air intake side (L - left) RIS 700VEL.0 Air intake side (L - left) RIS 260VER.0 RIS 400VER.0 RIS 700VER.0 260VE.0 400VE.0 700VE.0 LWA, Supply 68 59 61 6 62 60 5 4 Extract 58 46 50 56 51 44 40 26 Surrounding 49 9 40 44 42 40 4 24 Measured at 220 m /h, 100 Pa LWA, Supply 70 62 61 6 64 61 55 50 Extract 60 57 5 54 50 46 2 27 Surrounding 52 47 49 40 8 4 27 26 Measured at 400 m /h, 110 Pa LWA, Supply 74 68 65 67 66 65 58 57 Extract 65 58 60 61 57 50 47 7 Surrounding 55 51 52 44 7 4 1 22 Measured at 627 m /h, 110 Pa Exhaust air Extract air Fresh air Supply air 82
Static pressure [Pa] îè ëê èí ïïï ïíç ïêé ïçì îîî RIS 260VW.0 RIS 400VW.0 RIS 700VW.0 RIS 260VW.0 RIS 400VW.0 RIS 700VW.0 Extract air = 20 C/60%RH Outdoor air = -20 C 260VW.0 400VW.0 700VW.0 Water heater -power [kw] -water. T in /T ou [ o C] -water pressure drop [kpa] Pre-heater for heat exchanger [kw] 0, 1,0 1,2 Fans -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power/current [kw/a] 0,075/0, 0,207/0,91 0,205/0,89 -fan speed [min -1 ] 1880 2100 2000 -power/current [kw/a] 0,080/0,5 0,198/0,87 0,20/0,88 -fan speed [min -1 ] 1880 1850 2000 Motor protection class IP-44 IP-44 IP-54 55% 60% 60% Max power consumption [kw/a] 0,455/1,98 1,40/6,09 1,6/6,96 Automatic control integrated integrated integrated Filter class - G4 G4 G4 M5 M5 M5 Thermal insulation [mm] 20 0 0 Weight [kg] 40,0 68,0 82,0 Comply with ERP 201 + + + Designed for operation indoors only RIS 260VWL.0 RIS 400VWL.0 RIS 700VWL.0 RIS 260VWR.0 RIS 400VWR.0 RIS 700VWR.0 260VW.0 400VW.0 700VW.0 LWA, Supply 68 59 61 6 62 60 5 4 Extract 58 46 50 56 51 44 40 26 Surrounding 49 9 40 44 42 40 4 24 Measured at 220 m /h, 100 Pa LWA, Supply 70 62 61 6 64 61 55 50 Extract 60 57 5 54 50 46 2 27 Surrounding 52 47 49 40 8 4 27 26 Measured at 400 m /h, 110 Pa LWA, Supply 74 68 65 67 66 65 58 57 Extract 65 58 60 61 57 50 47 7 Surrounding 55 51 52 44 7 4 1 22 Measured at 627 m /h, 110 Pa Exhaust air Extract air Fresh air Supply air 8
Static pressure [Pa] èí ïêé îëð ííí íèç ëðð ëèí êêê RIS 1000VE.0 RIS 1500VE.0 RIS 1900VE.0 èí ïêé îëð ííí íèç ëðð ëèí êêê RIS 1000VE.0 RIS 1500VE.0 RIS 1900VE.0 Extract air = 20 C/60%RH Outdoor air = -20 C 1000VE.0 1500VE.0 1900VE.0 Heater -phase/voltage ~, 400 ~, 400 ~, 400 -power consumption [kw] 6,0 9,0 15,0 Fans -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power/current [kw/a] 0,29/1,04 0,72/1,62 0,650/2,87 -fan speed [min -1 ] 2650 2750 280 -power/current [kw/a] 0,29/1,04 0,80/1,66 0,650/2,87 -fan speed [min -1 ] 2650 2750 280 Motor protection class IP-44 IP-44 IP-54 54% 54% 60% Max power consumption [kw/a] 6,48/9,5 9,75/14,1 16,/2,5 Automatic control integrated integrated integrated Filter class - M5 M5 M5 M5 M5 M5 Thermal insulation [mm] 50 50 50 Weight [kg] 150,0 150,0 260,0 Comply with ERP 201 - - - Designed for operation indoors only RIS 1000VEL.0 RIS 1500VEL.0 RIS 1900VEL.0 RIS 1000VER.0 RIS 1500VER.0 RIRS 1900VER.0 1000VE.0 1500VE.0 LWA, Supply 80 67 7 74 75 69 66 54 Extract 68 65 62 61 58 5 45 4 Surrounding 60 52 5 54 5 49 44 9 Measured at 166 m /h, 120 Pa 1900VE.0 LWA, Supply 78 72 74 68 70 64 56 52 Extract 64 60 61 55 50 49 42 1 Surrounding 57 51 52 49 48 45 7 2 Measured at 109 m /h, 120 Pa LWA, Supply 86 59 76 77 80 81 76 66 Extract 70 60 6 66 64 56 50 41 Surrounding 6 47 55 57 58 57 51 44 Measured at 1819 m /h, 120 Pa Exhaust air Extract air Fresh air Supply air 84
Static pressure [Pa] èí ïêé îëð ííí íèç ëðð ëèí êêê RIS 1000VW.0 RIS 1500VW.0 RIS 1900VW.0 èí ïêé îëð ííí íèç ëðð ëèí êêê RIS 1000VW.0 RIS 1500VW.0 RIS 1900VW.0 Extract air = 20 C/60%RH Outdoor air = -20 C Water heater -power [kw] 6,7 9,4 12,8 -water temp. T in /T out [ o C] 80/60 80/60 80/60 [l/s] 0,08 0,11 0,16 -water pressure drop [kpa] 0,9 1,6, -kvs value [m³,1,2,2 Fans -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power/current [kw/a] 0,29/1,04 0,72/1,62 0,650/2,87 -fan speed [min -1 ] 2650 2750 280 -power/current [kw/a] 0,29/1,04 0,80/1,66 0,650/2,87 -fan speed [min -1 ] 2650 2750 280 Motor protection class IP-44 IP-44 IP-54 54% 54% 60% Max power consumption [kw/a] 0,478/2,08 0,752/,27 1,/5,65 Automatic control integrated integrated integrated Filter class - M5 M5 M5 M5 M5 M5 Thermal insulation [mm] 50 50 50 Weight [kg] 150,0 150,0 260,0 Comply with ERP 201 - - - Designed for operation indoors only 1000VW.0 1500VW.0 1900VW.0 RIS 1000VWL.0 RIS 1500VWL.0 RIS 1900VWL.0 RIS 1000VWR.0 RIS 1500VWR.0 RIRS 1900VWR.0 1000VW.0 1500VW.0 1900VW.0 LWA, Supply 78 72 74 68 70 64 56 52 Extract 64 60 61 55 50 49 42 1 Surrounding 57 51 52 49 48 45 7 2 Measured at 109 m /h, 120 Pa LWA, Supply 80 67 7 74 75 69 66 54 Extract 68 65 62 61 58 5 45 4 Surrounding 60 52 5 54 5 49 44 9 Measured at 166 m /h, 120 Pa LWA, Supply 8 60 77 78 77 75 72 6 Extract 68 58 6 6 62 55 48 4 Surrounding 61 46 54 56 55 54 48 4 Measured at 1819 m /h, 120 Pa Exhaust air Extract air Fresh air Supply air 85
RIS 260VE.0; 400VE.0; 700VE.0 (vertical) RIS 260VW.0; 400VW.0; 700VW.0 (vertical) IV PV PR KE PE PF IF TJ TL TE DTJ - air fan - air fan - plate heat exchanger - electrical heater - anti-freeze heater for heat exchanger - temperature sensor for air - temperature sensor for fresh air - temperature sensor for extract air - humidity + temperature sensor Supply air Extract air Fresh air Exhaust air Supply air Extract air Fresh air Exhaust air AVS IV PV PR PE PF IF TJ TL TV T1 TE DTJ M1 M - optionally supplied water heater - air fan - air fan - plate heat exchanger - anti-freeze heater for heat exchanger - temperature sensor for air - temperature sensor for fresh air - optionally supplied antifrost sensor - optionally supplied antifrost thermostat - temperature sensor for extract air - humidity + temperature sensor - optionally supplied mixing valve and motor - water heater circulatory pump 86
RIS 1000VE.0; 1500VE.0; 1900VE.0 (vertical) Supply air Extract air Fresh air Exhaust air RIS 1000VW.0; 1500VW.0; 1900VW.0 (vertical) IV PV PR KE PF IF TJ TL TE DTJ P M PS - air fan - air fan - plate heat exchanger - electrical heater - temperature sensor for air - temperature sensor for fresh air - temperature sensor for extract air - humidity + temperature sensor - heat exchanger pressure switch - by-pass damper - heat exchanger antifrost pressure switch Supply air Extract air Fresh air Exhaust air IV - air fan PV - air fan PR - plate heat exchanger KV - water heater PF IF TJ - temperature sensor for air TL - temperature sensor for fresh air TE - temperature sensor for extract air DTJ - humidity + temperature sensor P - heat exchanger pressure switch T1 - antifrost thermostat TV - antifrost sensor M - by-pass damper M1 - optionally supplied mixing valve and motor M - water heater circulatory pump PS - heat exchanger antifrost pressure switch 87