RIS V. AHU with heat recovery. exchanger. AHU is used for ventilation of houses and other heated areas. Stouch and TPC remote control devices.

Similar documents
RIS V EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. AHU med varmegenvinding AIR HANDLING UNITS

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

RIS H NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit Wärmerückgewinnung

RIRS V. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

EC L2. and humidity sensors. All units are supplied tested and ready to install.

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

CHIME-FLEX SA. Centrales compactes RECUPERATEUR A PLAQUES VERSION VERTICALE

RIRS V EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

RIRS H. AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła. Вентиляционные агрегаты с рекуперацией тепла

RIS H EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

RIS H EC NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit Wärmerückgewinnung

AIR HANDLING UNITS ver B

RIS P RIS P EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

Ventilationsaggregater med krydsvarmeveksler

RIRS H. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

KOMFORT EC DB Suspended heat recovery air handling units

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Series VENTS VUT R WH ЕС

RIRS H EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Swegon CASA. duct coils for heating. the supply air

RIS H EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

RIS. Rekuperatoriniai įrenginiai. AHU with heat recovery. Lüftungsgeräte mit wärmerückgewinnung. Вентиляционные агрегаты с рекуперацией тепла

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

TopMaster Air Handling unit. Technical data

RIS P RIS P EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Heat Recovery Unit HERU. web-version

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

TECHNICAL SPECIFICATION

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

Shunt groups and protection against freeze damage

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

VORT NRG RANGE COMMERCIAL VENTILATION NEW

TSEK VHR EC HEAT RECOVERY UNITS

Ceiling diffusers. Type DLQL

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

RECOVERY COILS AND ECODIRECTIVE 2018: CONTROL AND DEFROST

TopMaster Air Handling Unit

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

ECONET PREMIUM FAQ TROUBLE-SHOOTING: GT 21 GT 20 GT 00 GF 10 GT 10. Start by checking all indata for the air handling unit.

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

air handling units Issue 2016 ver. A

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Units for suspended ceilings

48 50 UH UA PACKAGED ROOFTOP

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Ceiling swirl diffusers

Ceiling swirl diffusers

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Heat Recovery Air Handling Units

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

We simplify construction

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

RoofVent Design Handbook

Thermozone RD. Air curtains for revolving doors

TopMaster Air Handling unit. Installation instructions

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

Heat pump & cooling unit in one

CAW Ceiling-mounted fan heaters for hot water

SILVERTOP RANGE ENERGY RECOVERY

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

MRXBOXAB-ECO3 MRXBOX-ECO3

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

MRXBOXAB-ECO2 MRXBOX-ECO2

Systemair product news - Fans NEWS

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

VENTILATION. Effective heat exchange and fresh air ventilation

50TM TFF COMBINATION HEATING/COOLING UNITS

Transcription:

AHU with heat recovery exchanger. AHU is used for ventilation of houses and other heated areas. Stouch and TPC remote control devices. 7040..0 housing: powder coated painting RAL - PASS. sami - montowane na kanale). - Flex, Stouch, TPC. Accessories Control panel Sensor controller Programmable controller Circular duct silencer Shuft-off damper Mounting clamp Heating coil Flex p. 178 Stouch p. 179 TPC p. 180 AKS p. 20 SKG p. 226 AP p. 229 AVS p. 192 80

RIS 260 Air intake side (L - left; R - right) Heater type (E - integrated electrical heater; W - optional water heater) AHU with plate heat-exchanger /h Type Type Flex Stouch TPC *** - anti-frost thermostat int - already integrated into the unit Dimensions [mm] L W H ød H 1 F 295 598 680 125-0 52 900 800 160-0 462 950 845 200-0 645 1400 1000 15 70 40 645 1400 1000 15 70 40 790 1650 1100 400 70 65 AKS SKG AP Accessories AVS SP TJP 10K CO4C*** SSB Heating RMG 80/60 0 C RMG 60/40 0 C VVP/VXP 80/60 0 C + 125 - LM20A-TP - - - - - - VVP/VXP 60/40 0 C + 125 125 TF20 + 81-0,6-4 -0,6-4 45.10-0,6 45.10-0,6 + 160 - LM20A-TP - - - - - - + 160 160 TF20 + 81-0,6-4 -0,6-4 45.10-0,6 45.10-0,6 + 200 - LM20A-TP - - - - - - + 200 200 TF20 + 81-0,6-4 -0,6-4 45.10-0,6 45.10-0,6 + 15 - LM20A-TP - - - - - - + 15 int LF20 int 81-1,0-4 -0,6-4 45.10-1,0 45.10-0,6 + 15 - LM20A-TP - - - - - - + 15 int LF20 int 81-1,0-4 -0,6-4 45.10-1,0 45,10-0,6 + 400 - SM20A-TP - - - - - - + 400 int SF20A int 81-1,6-4 -1,0-4 45.10-1,6 45.10-1,0 Accessories Actuator for dampers Duct sensor Thermic water valve actuator Mixing point 2 and - way valves SP p. 188 TJP 10K p. 187 SSB p. 184 RMG p. 185 VVP/VXP p. 186 81

Static pressure [Pa] îè ëê èí ïïï ïíç ïêé ïçì îîî RIS 260VE.0 RIS 400VE.0 RIS 700VE.0 RIS 260VE.0 RIS 400VE.0 RIS 700VE.0 Extract air = 20 C/60%RH Outdoor air = -20 C 260VE.0 400VE.0 700VE.0 Heater -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power consumption [kw] 1,0 2,0,0 Pre-heater for heat exchanger [kw] 0, 1,0 1,2 Fans -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power/current [kw/a] 0,075/0, 0,207/0,91 0,205/0,89 -fan speed [min -1 ] 1880 2100 2000 -power/current [kw/a] 0,080/0,5 0,198/0,87 0,20/0,88 -fan speed [min -1 ] 1880 1850 2000 Motor protection class IP-44 IP-44 IP-54 55% 60% 60% Max power consumption [kw/a] 1,455/6,,40/14,9 4,71/20,5 Automatic control integrated integrated integrated Filter class - G4 G4 G4 M5 M5 M5 Thermal insulation [mm] 20 0 0 Weight [kg] 40,0 68,0 82,0 Comply with ERP 201 + + + Designed for operation indoors only RIS 260VEL.0 Air intake side (L - left) RIS 400VEL.0 Air intake side (L - left) RIS 700VEL.0 Air intake side (L - left) RIS 260VER.0 RIS 400VER.0 RIS 700VER.0 260VE.0 400VE.0 700VE.0 LWA, Supply 68 59 61 6 62 60 5 4 Extract 58 46 50 56 51 44 40 26 Surrounding 49 9 40 44 42 40 4 24 Measured at 220 m /h, 100 Pa LWA, Supply 70 62 61 6 64 61 55 50 Extract 60 57 5 54 50 46 2 27 Surrounding 52 47 49 40 8 4 27 26 Measured at 400 m /h, 110 Pa LWA, Supply 74 68 65 67 66 65 58 57 Extract 65 58 60 61 57 50 47 7 Surrounding 55 51 52 44 7 4 1 22 Measured at 627 m /h, 110 Pa Exhaust air Extract air Fresh air Supply air 82

Static pressure [Pa] îè ëê èí ïïï ïíç ïêé ïçì îîî RIS 260VW.0 RIS 400VW.0 RIS 700VW.0 RIS 260VW.0 RIS 400VW.0 RIS 700VW.0 Extract air = 20 C/60%RH Outdoor air = -20 C 260VW.0 400VW.0 700VW.0 Water heater -power [kw] -water. T in /T ou [ o C] -water pressure drop [kpa] Pre-heater for heat exchanger [kw] 0, 1,0 1,2 Fans -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power/current [kw/a] 0,075/0, 0,207/0,91 0,205/0,89 -fan speed [min -1 ] 1880 2100 2000 -power/current [kw/a] 0,080/0,5 0,198/0,87 0,20/0,88 -fan speed [min -1 ] 1880 1850 2000 Motor protection class IP-44 IP-44 IP-54 55% 60% 60% Max power consumption [kw/a] 0,455/1,98 1,40/6,09 1,6/6,96 Automatic control integrated integrated integrated Filter class - G4 G4 G4 M5 M5 M5 Thermal insulation [mm] 20 0 0 Weight [kg] 40,0 68,0 82,0 Comply with ERP 201 + + + Designed for operation indoors only RIS 260VWL.0 RIS 400VWL.0 RIS 700VWL.0 RIS 260VWR.0 RIS 400VWR.0 RIS 700VWR.0 260VW.0 400VW.0 700VW.0 LWA, Supply 68 59 61 6 62 60 5 4 Extract 58 46 50 56 51 44 40 26 Surrounding 49 9 40 44 42 40 4 24 Measured at 220 m /h, 100 Pa LWA, Supply 70 62 61 6 64 61 55 50 Extract 60 57 5 54 50 46 2 27 Surrounding 52 47 49 40 8 4 27 26 Measured at 400 m /h, 110 Pa LWA, Supply 74 68 65 67 66 65 58 57 Extract 65 58 60 61 57 50 47 7 Surrounding 55 51 52 44 7 4 1 22 Measured at 627 m /h, 110 Pa Exhaust air Extract air Fresh air Supply air 8

Static pressure [Pa] èí ïêé îëð ííí íèç ëðð ëèí êêê RIS 1000VE.0 RIS 1500VE.0 RIS 1900VE.0 èí ïêé îëð ííí íèç ëðð ëèí êêê RIS 1000VE.0 RIS 1500VE.0 RIS 1900VE.0 Extract air = 20 C/60%RH Outdoor air = -20 C 1000VE.0 1500VE.0 1900VE.0 Heater -phase/voltage ~, 400 ~, 400 ~, 400 -power consumption [kw] 6,0 9,0 15,0 Fans -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power/current [kw/a] 0,29/1,04 0,72/1,62 0,650/2,87 -fan speed [min -1 ] 2650 2750 280 -power/current [kw/a] 0,29/1,04 0,80/1,66 0,650/2,87 -fan speed [min -1 ] 2650 2750 280 Motor protection class IP-44 IP-44 IP-54 54% 54% 60% Max power consumption [kw/a] 6,48/9,5 9,75/14,1 16,/2,5 Automatic control integrated integrated integrated Filter class - M5 M5 M5 M5 M5 M5 Thermal insulation [mm] 50 50 50 Weight [kg] 150,0 150,0 260,0 Comply with ERP 201 - - - Designed for operation indoors only RIS 1000VEL.0 RIS 1500VEL.0 RIS 1900VEL.0 RIS 1000VER.0 RIS 1500VER.0 RIRS 1900VER.0 1000VE.0 1500VE.0 LWA, Supply 80 67 7 74 75 69 66 54 Extract 68 65 62 61 58 5 45 4 Surrounding 60 52 5 54 5 49 44 9 Measured at 166 m /h, 120 Pa 1900VE.0 LWA, Supply 78 72 74 68 70 64 56 52 Extract 64 60 61 55 50 49 42 1 Surrounding 57 51 52 49 48 45 7 2 Measured at 109 m /h, 120 Pa LWA, Supply 86 59 76 77 80 81 76 66 Extract 70 60 6 66 64 56 50 41 Surrounding 6 47 55 57 58 57 51 44 Measured at 1819 m /h, 120 Pa Exhaust air Extract air Fresh air Supply air 84

Static pressure [Pa] èí ïêé îëð ííí íèç ëðð ëèí êêê RIS 1000VW.0 RIS 1500VW.0 RIS 1900VW.0 èí ïêé îëð ííí íèç ëðð ëèí êêê RIS 1000VW.0 RIS 1500VW.0 RIS 1900VW.0 Extract air = 20 C/60%RH Outdoor air = -20 C Water heater -power [kw] 6,7 9,4 12,8 -water temp. T in /T out [ o C] 80/60 80/60 80/60 [l/s] 0,08 0,11 0,16 -water pressure drop [kpa] 0,9 1,6, -kvs value [m³,1,2,2 Fans -phase/voltage ~1, 20 ~1, 20 ~1, 20 -power/current [kw/a] 0,29/1,04 0,72/1,62 0,650/2,87 -fan speed [min -1 ] 2650 2750 280 -power/current [kw/a] 0,29/1,04 0,80/1,66 0,650/2,87 -fan speed [min -1 ] 2650 2750 280 Motor protection class IP-44 IP-44 IP-54 54% 54% 60% Max power consumption [kw/a] 0,478/2,08 0,752/,27 1,/5,65 Automatic control integrated integrated integrated Filter class - M5 M5 M5 M5 M5 M5 Thermal insulation [mm] 50 50 50 Weight [kg] 150,0 150,0 260,0 Comply with ERP 201 - - - Designed for operation indoors only 1000VW.0 1500VW.0 1900VW.0 RIS 1000VWL.0 RIS 1500VWL.0 RIS 1900VWL.0 RIS 1000VWR.0 RIS 1500VWR.0 RIRS 1900VWR.0 1000VW.0 1500VW.0 1900VW.0 LWA, Supply 78 72 74 68 70 64 56 52 Extract 64 60 61 55 50 49 42 1 Surrounding 57 51 52 49 48 45 7 2 Measured at 109 m /h, 120 Pa LWA, Supply 80 67 7 74 75 69 66 54 Extract 68 65 62 61 58 5 45 4 Surrounding 60 52 5 54 5 49 44 9 Measured at 166 m /h, 120 Pa LWA, Supply 8 60 77 78 77 75 72 6 Extract 68 58 6 6 62 55 48 4 Surrounding 61 46 54 56 55 54 48 4 Measured at 1819 m /h, 120 Pa Exhaust air Extract air Fresh air Supply air 85

RIS 260VE.0; 400VE.0; 700VE.0 (vertical) RIS 260VW.0; 400VW.0; 700VW.0 (vertical) IV PV PR KE PE PF IF TJ TL TE DTJ - air fan - air fan - plate heat exchanger - electrical heater - anti-freeze heater for heat exchanger - temperature sensor for air - temperature sensor for fresh air - temperature sensor for extract air - humidity + temperature sensor Supply air Extract air Fresh air Exhaust air Supply air Extract air Fresh air Exhaust air AVS IV PV PR PE PF IF TJ TL TV T1 TE DTJ M1 M - optionally supplied water heater - air fan - air fan - plate heat exchanger - anti-freeze heater for heat exchanger - temperature sensor for air - temperature sensor for fresh air - optionally supplied antifrost sensor - optionally supplied antifrost thermostat - temperature sensor for extract air - humidity + temperature sensor - optionally supplied mixing valve and motor - water heater circulatory pump 86

RIS 1000VE.0; 1500VE.0; 1900VE.0 (vertical) Supply air Extract air Fresh air Exhaust air RIS 1000VW.0; 1500VW.0; 1900VW.0 (vertical) IV PV PR KE PF IF TJ TL TE DTJ P M PS - air fan - air fan - plate heat exchanger - electrical heater - temperature sensor for air - temperature sensor for fresh air - temperature sensor for extract air - humidity + temperature sensor - heat exchanger pressure switch - by-pass damper - heat exchanger antifrost pressure switch Supply air Extract air Fresh air Exhaust air IV - air fan PV - air fan PR - plate heat exchanger KV - water heater PF IF TJ - temperature sensor for air TL - temperature sensor for fresh air TE - temperature sensor for extract air DTJ - humidity + temperature sensor P - heat exchanger pressure switch T1 - antifrost thermostat TV - antifrost sensor M - by-pass damper M1 - optionally supplied mixing valve and motor M - water heater circulatory pump PS - heat exchanger antifrost pressure switch 87