Heat Recovery Units. Heat Recovery Units

Similar documents
Air Handling Unit. Air Handling Unit

TEVHR. Heat Recovery Ventilators

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

TSEK VHR EC HEAT RECOVERY UNITS

TEVHR. Heat Recovery Ventilators

FOUR-FHR Counter Flow Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

TEVHR. Heat Recovery Ventilator

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

Teknogen. Contents. Air Handling Unit Casing of the Unit Fan / Motor Damper Filter Cells Heating / Cooling Coil...

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

Industrial Evaporative Cooling Units

Package Hygienic Air Handling Units. PHK Series

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

havanızın konforu için... TÜRKÇE ENGLISH DEUTSCH РУССКИЙ ELEKTROSTATİK FİLTRE ÜRÜN KATALOĞU alperen.com.tr

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

KOMFORT EC DB Suspended heat recovery air handling units

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

TEKNOPOOL. Swimming Pool Air Handling Units

GHE Dehumidifiers for radiant cooling systems with heat recovery

TopMaster Air Handling unit. Technical data

PRODUCT CATALOG.

AZURE COUNTER FLOW HEAT RECOVERY VENTILATION. aera.com.tr

AHU Plus. DX Air Handling Units

TEVHR HEAT RECOVERY UNITS

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

INSTALLATION OPERATION MAINTENANCE INSTRUCTION HEAT PUMP HEAT RECOVERY UNITS VHR MODELS

Just feel well. 2017/2018 Air conditioning

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

3 rd Generation of VRV. The professional solution for your professional project

Safety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)

Series VENTS VUT R WH ЕС

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

Heat and energy recovery ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION

We simplify construction

Product Line Introduction. Karl Zhang Technical support engineer

AIR HANDLING UNIT TKS MODULAR AIR HANDLING UNIT

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

laboratory & sterilization technology

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Energy. The Energy ducted units have been designed. Heat Recovery Unit

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

COMMERCIAL ELECTRICAL AND SAND COFFEE COOKER USER MANUAL

TopMaster Air Handling Unit

E.C.A Air conditioners create a perfect silence environment with its outstanding performance

OT 300/430/570/710/850 STEAM STERILIZERS

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

laboratory & sterilization technology

SIMPLICITY OR FULL MODULARITY?

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

COMMERCIAL TYPE ELECTRICAL CORNET MACHINE USER MANUAL

Rapid. Suspended Warm Air Heater. Caring for the environment!

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

NC 100. Vertical Steam Sterilizer

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

NC SERIES. Bench Top Steam Sterilizers

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

LANDE SmartQube 19 Air-Conditioned Cabinet

Product Launch SHRMi

Circulation Pump Optima

Door Air Curtains. Tandem 300

HRV Brochure. Heat Recovery Ventilation

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Ducted inverter reverse cycle air conditioning

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Lo-Carbon Sentinel Kinetic Horizontal

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

laboratory & sterilization technology

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

SIMPLICITY FULL MODULARITY?

Transcription:

Heat Recovery Units Heat Recovery Units

VENTAS Isıtma, Soğutma, Enerji Sistemleri, İnşaat Sanayi ve Ticaret Anonim Şirketi; has been established in 2011 for production, consulting, project preparation and equipment supply in heating, cooling, air-conditioning and energy efficiency areas. VENTAS, which is established on top of twenty years of know-how and experience of its founders in the aforementioned sectors, is serving at its Istanbul Hadimkoy and Catalca production centres. The product portfolio of HVAC market s new brand VENTAS includes hygienic air handling units, comfort air handling units, high-efficiency heat-recovery ventilation units, fan coil units, exhaust fans with cabinet, supply fans with cabinet, duct type fans, roof type fans, fire smoke removal fans, trench heaters, roof top package air conditioning systems (water cooled, air cooled, gas-fired, heat recovery etc.) units. ISO 001, CE, TSEK, GOST-R and EN 1886 certificates and benefiting all advantages of modern high technology, in VENTAS production centres, high quality and durable products are manufactured by a dynamic and experienced expert team with a meticulous and neat workmanship, and a solution oriented approach. VENTAS brand s main principles are to serve its customers as a high quality solution partner and to provide excellent service with a dynamic structure both in pre-sales and after-sales. Having reached a fast and continuous growth track since it has been established, VENTAS has managed to become a well-known company in heating, cooling, air-conditioning and energy efficiency sectors throughout the country. Moreover, the Turkish brand VENTAS has penetrated its excellent and high quality products into international markets in a very short time frame, and offered a complete product supply chain to these markets through its wide dealer and service structure. Paying the utmost attention in its products to energy efficiency, endurance, reliability, sustainable technology and competitive price policy, VENTAS offers to be the corporate solution partner of all investors and mechanical construction companies in Turkey and all over the world, and shares its dynamic vision, renewed and developed continuously, with all its customers. EN 1886 2

www.ventas.com.tr Technical Specifications What is a heat recovery unit? In today's technology, heat recovery air-conditioning units are mechanical air conditioning units designed to produce high quality internal air in closed volumes while providing energy saving. Advantages These units work with the principle of adding energy within the air exhausted from the environment to the fresh air given to the environment by using internal air-to-air heat recovery plate exchangers. Thus, they allow for having high amount of energy savings. Today, heat recovery air-conditioning units are used in summer, winter and mid-seasons, through 12 months of the year, to meet the fresh air demand required to enhance the internal air quality within closed volumes while saving from energy costs. Especially in industrial and commercial air-conditioning applications, they provide important conveniences and wide range of deployment options. They contribute a lot to the business economics via highly efficient heat exchangers having high heat transfer capacities. In terms of deployment areas, they address multi functional buildings. For instance; they can address residence applications, office buildings, financial centres, chain stores, supermarkets, hospitals, shopping malls, schools, sport halls and restaurants. Features and usage advantages of VENTASTAR heat recovery air conditioning unit: Provides ease of operation and maintenance due to compact and slim design. Provides high quality indoor air with G4-class synthetic fiber. Enables excellent heat and sound insulation with specially insulated internal surface. In radial-fan types, it offers 3-stage operating capacity with direct coupled fans or proportional operating capacity. In plug-fan types, it offers proportional (no stage) operating capacity with direct coupled fans. With its specially designed electronic card control, fresh air supply and exhaust fans can be driven independently, hence, VENTASTAR heat recovery air-conditioning unit can provide positive or negative pressure operation in concerned volume. It has quality-safety certificates: CE, TSEK, ISO 001 and GOST-R. It provides heat recovery with high efficiency and capacity by using cross-flow aluminium plate heat exchangers with high thermal conductivity and performance. With its specially designed electronic card, it allows to be connected to building automation system (BMS). Possibility of adding internal air quality sensor and external air sensor. In all standard models, it is possible to be delivered from readily available stocks. In case of need, optionally out-of-standard production can be made for different capacities and working principles. Fresh Air Supply INDOORS Exhaust Return Duct Type Electric Heater Exhaust throw OUTDOORS Fresh air Filter Junction Box Fan Fan Filter Fresh Air Supply SURROUNDING Exhaust Return Exhaust throw OUTDOORS 3 Fresh Air Intake Power Supply Control Panel

Heat Recovery Units VENTASTAR VHRV-PL Plug-Fan Models Unit Components 5 4 1 Fresh air fan 2 Heat recovery exchanger 7 2 3 Exhaust fan 4 Service gate for fresh air filter 5 Fresh air filter 6 Exhaust air filter 7 Electronic card 1 3 8 6 8 Service gate for exhaust fan/filter Duct connection groove 101 Service gate for fresh air fan and filter 10 High efficiency plug-fan technology Supplies fresh air to provide the indoor air quality Provides energy savings with a high efficiency aluminium exchanger Provides G4 class filtering in both fresh air and exhaust sides. Low noise level Continuous speed control Wide Capacity Range Ergonomic size Easy installation and maintenance Duct type cooler hydrous coil 7/12 C Duct type cooler DX coil R410A electronic control panel (BASIC/PRO Model) VENTASTAR Plug Fan VHRV Models VHRV PL500 VHRV PL750 VHRV PL1000 VHRV PL1500 VHRV PL2000 VHRV PL3000 VHRV PL4000 Air Flow (m 3 /h) 500 750 1000 1500 2000 3000 4000 External Static Pressure (Pa) 130 120 120 140 200 110 110 Heat Recovery Efficiency Value (%) Power Supply Depending on operational temperature and conditions, up to 70% efficiency with Klingenburg Aluminium Recuperator 230 Volt / 50 Hz / 1 Input Power (Watt) 2 x 102 2 x 155 2 x 210 2 x 225 2 x 515 2 x 0 2 x 680 Input Current (Ampere) 2 x 0,45 2 x 0,68 2 x 0,3 2 x 1,0 2 x 2,25 2 x 2,4 2 x 3,0 Air Filter G4-Class Synthetic Fibre Cassette Filters at the entrance of Fresh air and Exhaust air Optional Accessory Duct Type Electrical Heater (kw) 1,5 Q200 2 Q200 3 Q250 4,5 Q300 6 Q300,0 Q355 12 Optional Accessory Duct Type Heater Hydrous Coil 0 / 70 (kw) 3,1 3,8 4,5 6,7,0 13,5 18,0 Optional Duct Type Cooler DX Coil Capacities-R410A (kw) 3,5-7 3,5-7 7-14 7-14 28-44,8 Length (mm) 850 850 80 1350 1350 1700 1800 Width (mm) 665 665 700 80 80 1180 1180 Height (mm) 310 310 340 640 Duct Connection Diameter (mm) Ø200 Ø200 Ø250 Ø300 Ø300 Ø355 Ø400 Weight (kg) 73 7 87 115 120 13 225 Service Space (mm) 330 330 350 40 40 50 00 Noise Level db(a) 42 43 43 45 52 55 * In our VENTASTAR PLUG-FAN PRO series, fans are continuously controlled proportionally. 4

www.ventas.com.tr VENTASTAR VHRV-RD Radial-Fan Models Unit Components 4 5 1 Fresh air fan 2 Heat recovery exchanger 2 7 3 Exhaust fan 4 Service gate for fresh air filter 3 1 5 Fresh air filter 6 Exhaust air filter 7 Electronic card 8 Service gate for exhaust fan/filter 6 Duct connection groove 10 Service gate for fresh air fan 8 10 High efficiency radial-fan technology Supplies fresh air to provide the indoor air quality Provides energy savings with a high efficiency aluminium exchanger Provides G4 class filtering in both fresh air and exhaust sides. Low noise level Wide Capacity Range 3 stage speed control Ergonomic size Easy installation and maintenance electronic control panel (BASIC/PRO Model) VENTASTAR Radial Fan VHRV Models VHRV RD2000 VHRV RD2500 VHRV RD3000 VHRV RD4000 VHRV RD5000 VHRV RD6000 VHRV RD8000 Air Flow (m 3 /h) 2000 2500 3000 4000 5000 6000 8000 External Static Pressure (Pa) 200 150 220 220 220 180 120 Heat Recovery Efficiency Value (%) Power Supply Depending on operational temperature and conditions, up to 70% efficiency with Klingenburg Aluminium Recuperator 230 Volt / 50 Hz / 1- Input Power (Watt) 2 x 450 2 x 450 2 x 550 2 x 750 4 x 750 4 x 750 4 x 750 Input Current (Ampere) 2 x 5,0 2 x 5,0 2 x 5,0 2 x 7,5 4 x 7,5 4 x 7,5 4 x 7,5 Air Filter G4-Class Synthetic Fibre Cassette Filters at the entrance of Fresh air and Exhaust air Optional Accessory Duct Type Electrical Heater (kw) 6,0 Q300,0 Q355,0 Q355 12,0 18 24 24 Optional Accessory Duct Type Heater Hydrous Coil 0 / 70 (kw),0 13,5 13,5 18,0 24 36 Optional Duct Type Cooler DX Coil Capacities-R410A (kw) 28-44,8 28-56 28-56 28-56 Length (mm) 1500 1700 1700 1800 100 2750 2750 Width (mm) 80 1180 1180 1180 2020 2055 2055 Height (mm) Duct Connection Diameter (mm) Ø300 Ø355 Ø355 Ø400 35x740 35x755 35x755 Weight (kg) 125 140 10 225 240 280 280 Service Space (mm) 700 800 800 00 1010 1030 1030 Noise Level db(a) 4 52 55 56 58 58 * In VENTASTAR Radial-Fan series, fans are controlled in 3-stage speed. 5

Heat Recovery Units VENTASTAR VHRV PLUS Models With Heater Coil and Cooler Coil (Plug-Fan) Unit Components 1 Recuperator Fresh air intake 2 8 7 3 Exhaust return 2 Fresh Air Filter 3 Exhaust Filter 4 Heater Coil 1 4 5 6 5 Cooler Coil 6 Drift Eliminator Exhaust throw Fresh air supply 7 Exhaust Fan 8 Fresh Air Fan Power Panel 10 10 Stainless Steel Drain Pan Radial and Plug-Fan Models VENTASTAR VHRV PLUS Models With Heater Coil and Cooler Coil (Plug-Fan) VHRV PL500 VHRV PL750 VHRV PL1000 VHRV PL1500 VHRV PL2000 VHRV PL3000 VHRV PL4000 Air Flow (m 3 /h) External Static Pressure (Pa) Heat Recovery Efficiency Value (%) Power Supply 500 750 1000 1500 2000 3000 4000 0 80 80 80 125 60 60 Depending on operational temperature and conditions, up to 70% efficiency with Klingenburg Aluminium Recuperator 230 Volt / 50 Hz / 1 Input Power (Watt) 2 x 102 2 x 155 2 x 210 2 x 225 2 x 515 2 x 0 2 x 680 Input Current (Ampere) 2 x 0,45 2 x 0,68 2 x 0,3 2 x 1,0 2 x 2,25 2 x 2,4 2 x 3,0 Air Filter G4-Class Synthetic Fibre Cassette Filters at the entrance of Fresh air and Exhaust air Optional Accessory Duct Type Electrical Heater (kw) 1,5 Q200 2 Q200 3 Q250 4,5 Q300 6 Q300 Q355 12 Duct Type Heater Hydrous Coil Capacities (kw) 3,1 3,8 4,5 6,7 13.5 18 Duct Type Cooler Hydrous Coil Capacities (kw) 3,5 5,5 7,5 11 15 22 30 Duct Type Cooler DX Coil Capacities-R410A (kw) 3,5-7 3,5-7 7-14 7-14 28-44,8 Length (mm) 1630 1630 1760 2180 2180 2580 2680 Width (mm) 820 20 0 1230 1330 1530 1630 Height (mm) 310 310 340 640 Duct Connection Diameter (mm) Ø200 Ø200 Ø250 Ø300 Ø300 Ø355 Ø400 Weight (kg) 73 7 87 115 120 13 225 Service Space (mm) 410 460 40 620 660 760 810 Noise Level db(a) 42 43 43 45 52 55 6

www.ventas.com.tr VENTASTAR VHRV PLUS Models With Heater Coil and Cooler Coil (Radial Fan) High efficiency radial fan and plug-fan technology Supplies fresh air to provide the indoor air quality Provides energy savings with a high efficiency aluminium exchanger Provides G4 class filtering in both fresh air and exhaust sides. Low noise level Proportional or 3 stage speed control Possibility to work like a fresh air unit with its heater and cooler coils Provides heating and cooling capacity support Electronic card that can perform proportional capacity control and operating mod selection, which works fully compatible with DX external unit Easy installation and maintenance VENTASTAR VHRV PLUS Models With Heater Coil and Cooler Coil (Radial Fan) Air Flow (m 3 /h) External Static Pressure (Pa) Heat Recovery Efficiency Value (%) Power Supply Input Power (Watt) Input Current (Ampere) Air Filter Optional Accessory Duct Type Electrical Heater (kw) Duct Type Heater Hydrous Coil Capacities (kw) Duct Type Cooler Hydrous Coil Capacities (kw) Duct Type Cooler DX Coil Capacities-R410A (kw) Length (mm) Width (mm) Height (mm) Duct Connection Diameter (mm) Weight (kg) Service Space (mm) Noise Level db(a) VHRV RD2000 2000 120 Depending on operational temperature and conditions, up to 70% efficiency with Klingenburg Aluminium Recuperator 2 x 450 2 x 5,0 6 Q300 15 2330 1330 Ø300 125 700 VHRV RD2500 2500 100 2 x 450 2 x 5,0 G4-Class Synthetic Fibre Cassette Filters at the entrance of Fresh air and Exhaust air Q355 13.5 18 2580 1530 Ø355 140 800 4 VHRV RD3000 3000 220 2 x 550 2 x 5,0 Q355 13.5 22 2580 1530 Ø355 10 800 52 VHRV RD4000 4000 160 230 Volt / 50 Hz / 1 2 x 750 2 x 7,5 12 18 30 28-44,8 2680 1650 Ø400 225 00 55 VHRV RD5000 5000 140 4 x 750 4 x 7,5 18 24 35 28-56 2780 2 35x740 240 1010 56 VHRV RD6000 6000 0 4 x 750 4 x 7,5 24 36 40 28-56 3630 2755 35x75 280 1030 58 VHRV RD8000 8000 100 4 x 750 4 x 7,5 24 28-56 3680 3055 35x75 280 1030 58 7

Heat Recovery Units VENTASTAR VHRV VT Vertical Type Application Model Diameters A C D B E E VENTASTAR VHRV Vertical Type VT Model Width (mm) A Height (mm) B Depth (mm) C Height with legs (mm) D Duct Connection Diameter (mm) E VHRV VT PL500 665 50 310 1030 200 VHRV VT PL750 665 50 310 1030 200 VHRV VT PL1000 700 1080 340 1160 250 VHRV VT PL1500 80 1450 1530 300 VHRV VT PL2000 80 1450 1530 300 VHRV VT RD2000 80 1600 1680 300 VHRV VT RD3000 1205 2105 550 2185 400 VHRV VT RD4000 1205 2105 550 2185 400 VHRV VT RD5000 2020 2000 550 2080 35x740 VHRV VT RD6000 2055 2850 550 230 35x755 VHRV VT RD8000 2055 2850 550 230 35x755 *Vertical type designed version of our standard heat recovery unit models. It has all technical specifications that standard heat recovery unit models have. Duct connections are designed as rectangular for VHRV VT 5000, 6000 and 8000 models. 8

www.ventas.com.tr VENTASTAR Heat Recovery Air Conditioning Units Electronic Board Features VENTASTAR heat recovery air conditioning units are controlled with a standard electronic board and a wired room control device. Ventastar heat recovery air conditioning units have 2 different control options according to their functional features. These options are presented as VENTASTAR BASIC and VENTASTAR PRO models. Wired room control device has the functions to turn the unit on and off, to control fresh air and exhaust fans separately as proportional or 3 stage speeds according to fan type (plug or radial), to optionally connect to duct type electrical heater or duct type hydrous coil staged control functions, and to connect to central automation system (BMS) or VRV/VRF system. It can also display status and error information just like an air handling unit automation. VENTASTAR BASIC Control Card VENTASTAR PRO Control Card Indoor Thermostat FUNCTIONAL FEATURES ROOM CONTROL PANEL Room control panel (wired) Room temperature sensor Touch keypad Ability to communicate with electronic power board Visual warning and error notification Advanced user and service menu Remote control panel (wireless) Central control panel ELECTRONIC CARD (POWER UNIT) Fresh air fan control continuous (proportional) Exhaust air fan control continuous (proportional) Ability to drive fans independently 220 V AC supply High voltage protection Air quality sensor connectivity Blow air temperature sensor connectivity External air sensor connectivity Humidity sensor connectivity Filter contamination sensor connectivity Fan rotation detection possibility Cooler coil control (proportional) Heater coil control (proportional) Damper motor control Alarm and warning outputs BMS MODBUS connectivity EMI-RFI filter possibility Hour-Date weekly program possibility Summer-Winter program possibility Humidification and dehumidification control possibility (0-10 Volts) Inverter control device EC motor control possibility (0-10 Volts) VENTASTAR BASIC Optional Optional - - - - VENTASTAR PRO Optional Optional

Heat Recovery Units Optional Accessories Duct Type Silencers VENTAS duct type silencers are produced in two different models: VDS model for circular duct system and VDKS model for rectangular duct system. Production of all silencers are performed according to international standards, sizes, coulisse numbers. Circular silencers are produced in standard circular duct sections, whereas rectangular duct type silencers can be produced according to the required sizes of the project. All models are appropriate for fast and easy assembly to the existing duct system with minimum air leakage. For sound isolation, glass wool is used as our standard production and optionally rock wool can be used. Duct Type Electric Heater VENTASTAR KTE duct type electric heaters are produced according to EMC 8/336/EEC directives, as per EN 55014-1, EN 61000-3-2/3-3 standards with EMC tests done. They are produced in standard circular duct section sizes as monophase and triphase. Duct type electric heaters have two emergency thermostats for excessive-temperature cut out. VENTASTAR heat recovery air conditioning units can be controlled automatically with an electronic card or manually on the device. Duct Type Heater Or Cooler Hydrous Coil VENTASTAR KSB duct type hydrous coil are produced both in rectangular and circularduct sections in standard capacities, whereas different project based capacities can be produced upon request. Duct type hydrous coil units are designed in order to be deployed easily in suspended ceiling, to be directly applied into the blowing entrances of heat-recovery units and to provide easy installation and maintenance. External Air Bypass Connection Kit Heat-recovery air conditioning units provides energy saving by means of the heat transfer between the warm and cold phases of plate exchanger. Especially in mid-seasons (spring and autumn) or in morning and evening hours, the external air temperature gets closer to the internal ambient temperature. In order to use the fresh air more efficiently (in order to remove the exchanger pressure fail), the plate exchanger can be bypassed. Besides, in warm mid seasons, if the external air temperature reduces below the internal air temperature, the plate exchanger is bypassed in order to benefit from this air to cool indoor air. With the by-pass kit, external air temperature is controlled by the electronic card automatically, and the external air is blown inside bypassing the plate exchanger when needed. By-pass By-pass Damper Filter Exhaust Return Fresh air supply External Air Sensor Fresh air intake Exhaust Return Damper 10

11 www.ventas.com.tr

Ventas Isıtma, Soğutma, Enerji Sistemleri, İnşaat San. ve Tic. A.Ş. Ventas Headquarters Ortaklar Cd. Denizhan Sk. Lale Han No:7 Kat:2 Mecidiyeköy Şişli, İstanbul, Turkey T: +0 212 216 05 16 F: +0 212 216 05 14 Ventas Hadımköy Facility Alkop Alüminyumcular Sanayi Sitesi C1 Blok No:1-2-3-4-5, 34500 Esenyurt, İstanbul, Turkey T: +0 212 858 12 82 F: +0 212 858 12 7 Ventas Catalca Facility Çakıl Mh. Elbasan Cd. No: 126/A 34 Çatalca, İstanbul, Turkey T: +0 212 858 12 82 F: +0 212 858 12 7 Ankara Regional Office: Aziziye Mahallesi Kırkpınar Sokak No: 10/5 Çankaya, Ankara, Turkey T: 0312 43 5 50 F: 0312 43 5 50 Bursa Regional Office: Alaaddinbey Mh. Pazar Cd. No:27 A/C Nilüfer, Bursa, Turkey T: +0 224 441 03 66 F: +0 224 441 03 67 Diyarbakır Regional Office: Kayapınar Mah. Gap Bulvarı Peyas 1 Sok. No:1 A Blok Kayapınar, Diyarbakır, Turkey T: +0 412 251 51 45 F: +0 412 251 51 45 Konya Regional Office: Fevzi Çakmak Mahallesi 10670 Sokak 27/B Karatay, Konya, Turkey T: +0 332 236 22 64 F: +0 332 236 73 56 www.ventas.com.tr 2016/VEB/1