Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Similar documents
Model GPT 3 Freeze Protection Thermostat

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Model GIT 4 Gutter Snow and Ice Melting Control

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

SAFETY INFORMATION AND WARNINGS

ADDITIONAL INFORMATION

SC-40 Satellite Contactor

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

SAFETY INFORMATION AND WARNINGS

SECTION AUTOMATIC TRANSFER SWITCHES

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Beacon 800 Gas Monitor Operator s Manual

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

PART GENERAL 1.01 SECTION INCLUDES

Instruction Manual Model L2 RF Switch

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

FPC-02 Series. Installation and Operating manual

SECTION AUTOMATIC TRANSFER SWITCHES

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Model 4001 Series Single Channel Controller

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Installation, Operation & Service Manual

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

SECTION AUTOMATIC TRANSFER SWITCHES

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

Warranty Info: ETI s warranty policy can be viewed at:

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

INSTALLATION AND INSTRUCTION MANUAL

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

TFD-1 Installation & User s Guide

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

KM300 Carbon Monoxide Detection System Installation Manual

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

UNC100 Integra Manual

XC Portable Air Conditioning

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT

Installation and Operations Manual

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

SECTION ISOLATED POWER SYSTEMS

Installation Instruction Manual ILS-S

Inline Heater for Solvent or Gas. Installation and Operation Manual

K00364 Electronic Bin Thermostat

OFFICE PRO 36 and OFFICE PRO 60 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE AND READ ALL SAFEGUARDS

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Public Safety DAS Annunciator Panel

NXM2G Installation and Operating Manual

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18. Unit Serial Number Range: 1111XXXX### to Present (From November 2011 to Present)

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Surna 25-Ton Chiller Operating & Maintenance Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Model 3300 Technical Support and Installation Manual

IF-L/RF Protection Switch

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

OFFICE PRO 63 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE AND READ ALL SAFEGUARDS

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Model 17A00 Expansion Enclosure

Cedarbrook Sauna + Steam Family owned and operated since 1971

4 & 8-POINT ANNUNCIATORS Instruction Manual

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

PROJECT MANAGEMENT Transmittal No 17D

Reflective Optical Beam Smoke Detector User Guide

26 LB CAPACITY ICE MAKER

IMPORTANT INSTRUCTIONS READ & SAVE

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

CHAPTER 20 SERVICE EQUIPMENT

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

Instruction Manual August sitrans CU 02

WATROD & FIREBAR Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:11/25/2013 Rev: 4.00

Transcription:

MANUAL We manage heat Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 http://www.networketi.com/ 20656 Rev. B 02/16 http://www.networketi.com Environmental Technology, Inc.

2 of 12 Environmental Technology, Inc. http://www.networketi.com 20656 Rev. B 02/16

Table of Contents Tracon Model GPT-3 Freeze Protection Thermostat Installation and Operation Manual Safety 4 Contacting Environmental Technology 4 General 5 Introduction 5 Operation 6 Normal 6 Abnormal 6 Installation 6 First 6 Next 6 Location 7 Supply and Heater Connections 7 Sensor and Alarm Relay Connections 8 General 8 Temperature Sensors 8 Alarm Relay Contacts 9 Setup 9 Factory Settings 9 Custom Settings 10 General 10 GFEP 10 Mode 11 Current 11 Constant Wattage Heater Mode 11 Maintenance 11 General 11 Troubleshooting 11 Returns 11 Specifications 12 20656 Rev. B 02/16 http://www.networketi.com Environmental Technology, Inc. 3 of 12

Safety Make all electrical connections in compliance with the National Electrical Code (NFPA 70) and local electrical code. If you have questions concerning the installation or application, contact Customer Service. Abnormal Odor or Smoke In the event of smoke or a burning or abnormal odor, immediately interrupt power to the unit by unplugging the unit or by turning off the circuit breaker protecting the unit. Electrical Shock / Fire Hazard Even when the snow melting elements are disconnected, as long as the circuit breaker is on and power is running to the unit, voltage is still being applied to the system s yellow leads. Therefore, never touch the ends of the yellow leads or let the two leads touch each other. Do not let the two yellow leads contact any component inside the unit. Any installation involving electric heater wiring must be grounded to earth to protect against shock and fire hazard. Suitable ground fault detection and interrupting systems must be in use at all times to reduce shock and fire hazard and to protect equipment. Electric wiring to heating elements must be installed in accordance with National Electrical Code (NEC) requirements and all other local and applicable electrical codes and any third party standards. Follow the installation instructions contained herein and those provided by the heater manufacturer. Use a GFEP (Ground Fault Equipment Protection) circuit breaker on each branch circuit connected to the ice melting system. Clearly label each circuit breaker with its function. This is vitally important when there is more than a single point of disconnect. Size the circuit breaker in accordance with the size of the expected load. The maximum current load for the GPT-3 is 30 Amps maximum. This product is intended for use between electromechanical thermostats and high-end general purpose single and multiple channel temperature controls. Make certain that the heater shield is properly grounded. Failure to do so may result in damage to the equipment or fire. Additional Information More information is made available regularly through our website, www.networketi.com. Please visit us online for Data Sheets, Manuals, White Papers, technical articles, and more. The most current and up to date version of this and every other manual for our products can be found in Acrobat (PDF) format to view online or to print. This is to assist you in installing and using our products to the best effect possible. If you have any comments about this or any other product from Environmental Technology, Inc., please contact us. Contacting Environmental Technology, Inc. For assistance, please contact Customer Service. Office hours are from 8:00 AM until 5:00 PM ET. E-mail: Mail: info@networketi.com Environmental Technology, Inc. 1850 North Sheridan Street South Bend, IN 46628 4 of 12 Environmental Technology, Inc. http://www.networketi.com 20656 Rev. B 02/16

General Introduction The GPT 3 Freeze Protection Thermostat has a calibrated adjustment range of 41 to 77 F (5 to 25 C) with a control band of 2 F (1 C). Heaters operate at ambient temperatures below the set temperature. The GPT 3 combines temperature control using either constant wattage or self-limiting heaters with GFEP (ground fault equipment protection) and advanced monitoring features. For example, although the GFEP is factory set to trip at 30 ma, this threshhold can be set to 60, 90 or 120 ma to cure nuisance tripping problems. Keeping wet fire sprinklers from freezing is considered to be a higher priority than interrupting heater power in the event of a ground fault condition. The GPT 3 accommodates this requirement by allowing the GFEP to be set only to alarm while the ground fault persists. Other features include continuous heater monitoring with separate modes for constant wattage and self-limiting heaters. A trickle current verifies heater continuity of both heater types when there is no call for heat. The current flow through constant wattage heaters verifies continuity during operation. Self-limiting heaters employ an independent temperature monitor sensor (included) to measure the hot-end temperature. Depending upon how long it takes the cable to reach its operating temperature such that the monitor sensor is less than 5 F (3 C) below the control sensor temperature, the GPT 3 may momentarily declare a cold heater. The GPT 3 automatically executes a self-test every 24 hours. First, heaters are de-energized. Then, the GFEP verifies its own operation. Finally, it checks the heaters for ground fault under operating conditions. This entire process takes about two seconds. Other features include verifying the integrity of both the control and monitor temperature sensors and checking the contactor for open or shorted contacts. A control temperature sensor failure also inhibits contactor operation in addition to asserting an alarm condition. The GPT 3 automatically accommodates 120, 208, 240 and 277 supply voltages. Since the heaters and the GPT 3 operate from the same supply voltage, the safety hazard created by multiple points of disconnect is eliminated. The heater control contactor is rated for up to 30 amps. The GPT 3 provides a reverse acting isolated Class 2 alarm relay contact SPDT rated at one amp. Reverse action makes absence of supply voltage an alarmed condition. Although the GPT 3 housing is NEMA 3R rated for indoor or outdoor service, a protected location is recommended. The operating temperature range is 40 to 136 F ( 40 to 58 C). Padlocking the transparent front cover can prevent tampering without interfering with the view of the status indicators. Tracon Model GPT-3 Freeze Protection Thermostat Installation and Operation Manual Figure 1. GPT 3 dimensional drawing 20656 Rev. B 02/16 http://www.networketi.com Environmental Technology, Inc. 5 of 12

Operation Normal The GPT 3 requires little or no attention after installation. Although changing the temperature setting can improve heating system performance, this is seldom necessary. Minimum energy use occurs when the the temperature is set to the minimum value providing the desired heating performance. Normal operation occurs when neither the Fault nor the GFEP indicators operate and the Alarm relay is off. Otherwise, operation is abnormal. How the GPT-3 LEDs Work First two seconds (self test): all LEDs on. After that: Power LED: always on Heater LED: Off: no alarm, no heat On steady: heating Flash once: heater open (no trickle current) [no control] Flash twice: relay stuck on [no control] Flash three times: relay stuck off (constant wattage only) [no control] GFEP fault LED: Off: normal operation Blink very rapidly: in ground fault test Blink even: ground fault condition [ no control if latching mode] Flash twice: gfep circuit failure [no control if latching] Heater Fault LED: Off: normal operation Blink even: low temp (self-limiting only) Flash twice: bad control thermistor [no control] Flash three times: bad monitor thermistor Abnormal With one exception, operation of either the Alarm relay or Fault indicator or both means that a failure has occurred that requires a qualified electrician to correct. The exception is momentary indication of a self-limiting heater failure as is shown by blinking the Heater indicator when the GPT 3 is used with self-limiting cable. The GPT 3 detects a self-limiting heater failure by measuring its temperature at the far end of the cable. Depending upon how long it takes the cable to reach its operating temperature such that the monitor sensor is less than 5 F (3 C) below the control sensor temperature, the GPT 3 may momentarily declare a cold heater. Many indicators display additional information concerning equipment failures through flashing (see How the GPT-3 LEDs Work at left). Check the Troubleshooting section for additional information since service by qualified personnel is required. Installation First Inspect the package and its contents for damage. In the event of damage, immediately contact Environmental Technology, Inc. Customer Service. Next Check the contents of the package against the pro forma Packing List shown below. If discrepancies are found, contact ETI Customer Service before starting the installation. Pro Forma Packing List Order Number Quantity Description 19425 1 GPT 3 Freeze Protection Thermostat 25076 (or 19272) 2 Temperature Sensor 20656 1 GPT 3 Installation and Operation Manual 18703 4 Wire Nuts, Red 6 of 12 Environmental Technology, Inc. http://www.networketi.com 20656 Rev. B 02/16

Location The GPT 3 is suitable for indoor or outdoor mounting on a vertical surface. Although the NEMA 3R rated housing is strong and durable, choose a protected location for an extra safety margin. Always consider the possibilities of tampering and vandalism when choosing a location. Keep the GPT 3 and the heat cable as close together as is practical to minimize installation costs. There is a 2,000 (610m) limit on temperature sensor extension wiring. Figure 1 shows mechanical dimensions of the GPT 3. Note the location of the compartment provided for low voltage Class 2 connections. Supply and Heater Connections The GPT 3 operates from 120, 208, 240 or 277 volts which it automatically selects. The heaters and GPT 3 operate from the same supply voltage. The definite purpose DPST heater control contactor is rated for up to 30 AMP loads at 277 volts or less. Make the supply voltage and heater connections in the compartment provided for this purpose. Use only copper wire for supply, heater and safety ground connections. Select a minimum wire size of 10 AWG with, minimum, 300 volt insulation rated for at least 75ºC. Figure 2 shows a pictorial wiring diagram of the heater and supply voltage connections. Use appropriately rated wire nuts or bomb splices for all heater and supply connections. Connect the equipment safety ground and heater shield ground to the lug provided for this purpose. Tracon Model GPT-3 Freeze Protection Thermostat Installation and Operation Manual Figure 2. GPT 3 wiring diagram 20656 Rev. B 02/16 http://www.networketi.com Environmental Technology, Inc. 7 of 12

Sensor and Alarm Relay Connections General The two temperature sensors are connected to the terminal block in the low voltage compartment along with the connections to the reverse acting isolated SPDT alarm relay. Use #18 AWG copper wire with insulation rated for 300 volt service for all Class 2 connections unless otherwise noted. Using jacketed extension wiring, although convenient, is not necessary. Using metallic conduit for extension wires is recommended. Never route Class 2 circuits in the conduit used for supply and heater voltage circuits. Temperature Sensors Two identical temperature sensors are supplied with the GPT 3. Each is supplied with 20' (6m) of extension wire. For distances of up to 500' (152m), use #18 AWG copper wire and #12AWG for up to 2,000' (610m). Temperature sensor connections are non-polar. Systems using self-limiting heaters require two temperature sensors. Figure 3 showsconnection of the two sensors. The GPT 3 comes factory set for self-limiting cable. Systems using constant-wattage heaters require only one sensor as is shown in Figure 4 on the following page. Upon completion of the installation, dispose of the unused sensor. Figure 3. Control and monitor sensor connections for self-limiting heaters 8 of 12 Environmental Technology, Inc. http://www.networketi.com 20656 Rev. B 02/16

Figure 4. Control sensor connection for constant wattage heaters Alarm Relay Contacts Figure 5 shows the alarm relay connections. The relay contacts are rated for one amp in NEC Class 2 service. Contact Customer Service if higher voltage operation is required. Figure 5. Alarm relay connections Setup Factory Settings The GPT 3 comes set for the most common systems. This includes: Self-limiting cable GFEP set at 30 ma GFEP set for manual reset The factory DIP switch settings follow: FACTORY SETTINGS Pole 1 2 3 4 5 6 Setting Off Off Off Off --- --- 20656 Rev. B 02/16 http://www.networketi.com Environmental Technology, Inc. 9 of 12

Custom Settings General The performance of the GPT 3 can be adjusted to match the needs of the application using the DIP switch as shown in Figure 6. Accessing this switch usually requires removing the electronic assembly from its housing. Figure 7 shows the screws that need to be removed to access the DIP switch. Make any DIP switch changes before making the supply voltage and heater connections. Otherwise, it will probably be necessary to break and re-make these connections. DIP switch poles that do not require change are labeled NC. Spare switch poles are labeled ---. GFEP Mode Fire protection sprinkler and certain other critical applications consider GFEP secondary in importance to freeze protection. The GPT 3 accommodates these applications by warning of a ground fault condition while it exists. Heaters operate independent of the ground fault condition. Automatic GFEP Reset Setting Pole 1 2 3 4 5 6 Setting On NC NC NC --- ---- Figure 6. DIP switch detail Figure 7. Removing electronic assembly from housing 10 of 12 Environmental Technology, Inc. http://www.networketi.com 20656 Rev. B 02/16

Current The GFEP current setting can be increased from its factory set 30 ma value to 120 ma in 30 ma steps. The higher current settings serve the special purpose of eliminating spurious GFEP tripping. Accessing this function was made intentionally difficult to prevent its casual use. The DIP switch settings follow: 60 ma GFEP Setting Pole 1 2 3 4 5 6 Setting NC NC On Off --- --- Tracon Model GPT-3 Freeze Protection Thermostat Installation and Operation Manual 90 ma GFEP Setting Pole 1 2 3 4 5 6 Setting NC NC Off On --- --- 120 ma GFEP Setting Pole 1 2 3 4 5 6 Setting NC NC On On --- --- Constant Wattage Heater Mode The GPT 3 provides a special operating mode for checking the continuity of constant wattage heaters. The DIP switch setting is shown below: Constant Wattage Heater Setting Pole 1 2 3 4 5 6 Setting NC On NC NC --- --- Maintenance General The GPT 3 does not require routine maintenance. It contains no field replaceable components. Troubleshooting The GPT 3 provides extensive fault diagnosis capability for the purpose of quickly identifying and correcting system problems. Front panel indicators perform multiple functions so as to provide the greatest amount of information. With one exception, one or more indicators flashing in repetitive patterns mean that a fault requiring a qualified technician for correction has occurred. See How the GPT-3 LEDs Work at right. The exception is operation of the HEATER FAULT indicator in a 50% on, 50% off pattern when using self-limiting cable. This can occur when heaters first operate due to the time delay between the application of power and attaining thermal equilibrium. Detailed troubleshooting instruction can be obtained from either Customer Service or the Environmental Technology, Inc. web site at http://www.networketi.com. Returns Contact Customer Service to obtain a Return Authorization before shipping anything to Environmental Technology, Inc. Otherwise, the shipment may be refused. 20656 Rev. B 02/16 http://www.networketi.com Environmental Technology, Inc. 11 of 12

SPECIFICATIONS Control Range Dead Band Electrical Supply voltage Load Alarm Relay Indicators Supply (Red) Heater (yellow) GFEP (red) Fault (red) GFEP Settings Reset Auto-test Heater Monitoring Choices Alarm Relay Temperature Limits Operating Storage 41 F to 77 F ( 5 C to 25 C) 2 F (1 C) 120, 208, 240 or 277 volts auto-selected 30 amps maximum Isolated SPDT 1 amp Class 2 contact Power applied Call for heat Ground fault occurring or has occurred Contactor failure Temperature sensor failure Power-on sensor check failure 30 ma default, 60, 90, 120 ma selectable Manaul Default Every 24 hours Self-limiting default, constant wattage selectable No Power Heater failure Contactor failure Ground fault of GFEP circuit failure Temperature sensor failure 40 F to 136 F ( 40 C to 58 C) 67 F to 167 F ( 55 C to 75 C) ORDERING INFORMATION Order Number Description 19425 GPT-3 Freeze Protection Thermostat (QTY 1) LIMITED WARRANTY ETI s two year limited warranty covering defects in workmanship and materials applies. Contact Customer Service for complete warranty information. DISCLAIMER Environmental Technology, Inc., makes no representations or warranties, either expressed or implied, with respect to the contents of this publication or the products that it describes, and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Environmental Technology, Inc., reserves the right to revise this publication, and to make changes and improvements to the products described in this publication, without the obligation of Environmental Technology, Inc. to notify any person or organization of such revisions, changes or improvements. The ETI logo, We Manage Heat, Tracon and GPT are registered trademarks of Environmental Technology, Inc. Copyright 2013 Environmental Technology, Inc. All rights reserved. No part of this manual may be reproduced or translated in any form or by any means, electronic or mechanical including photocopying and recording, for any purpose without the express written consent of Environmental Technology, Inc. Printed in USA. 12 of 12 Environmental Technology, Inc. http://www.networketi.com 20656 Rev. B 02/16