PRODUCT GUIDE. Spike+ System Product Guide CONTENTS:

Similar documents
The Ruby Street Brewery. Owners Manual. Ruby Street Brewing, LLC. Fort Collins, Colorado USA

HERMS (Heat Exchanger Recirculating Mash System) Controller

Robobrew 35L All In One Brewery with Pump Model: 8695

Electric-TOWER of POWER

FIVE EASY HOMEBREW PROJECTS

Therminator TM. Operation, Assembly & Maintenance Manual

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

Instruction Sheet WELCOME TO THE CLUB

2 BBL Hybrid Brewhouse

3.5 BBL Hybrid Brewhouse

3.5 BBL Hybrid Brewhouse

Engineering for the Craft Brewer. Lecture 6 Summer 2014

MARKS DESIGN & METALWORKS, LLC BREWERY TANKS AND SYSTEMS

Automated Electric Brewing System

Brewmaster Edition Chronical Fermenter 1 Barrel Supplemental Report

Quick Tips Electronic Temperature Controllers (ETC)

Automated Electric Brewing System

Crysalli/Western Pacific 1739 Sabre Street Hayward, CA

The Hop Stopper 2.0 User s Guide

2015 Catalog. Tim Wills - Equipment Representative - Australia & New Zealand

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

PROFESSIONAL BREW DEVIL MICRO BREWERY INSTRUCTION MANUAL. Thank you for purchasing this Brew Devil Microbrewery system.

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5

PWC-500/1000/1010/1500

Fast and Easy Cooler Mash Tun Build

HWD-2110 Hot Water Dispenser

CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION

Horizon Elite Ice Machine Models with RIDE Technology Installation Instructions for Drop-In

Refrigerator. Installation Guide. Free Standing Appliance

SpeedClave Steam Sterilizers

Rev INTRODUCING: NANO-MAGIC RIMS 2BBL, Brewing System by SABCO. .. with design collaboration by Dogfish Head Brewery.

Conical Fermenter. Instructions

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

ONLY stainless steel valve station

Clean Water Made Easy

Installation guide. Before installing read this guide first

Robobrew 35L All In One Brewery with Pump Generation 3 Model: KL04749

MULTI FLOW HYDROPONIC SYSTEM

Owner's Manual. WS Series. Water Softener

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:

OPERATION MANUAL OPERATION MANUAL FREE WATER-COOLED HEAT EXCHANGER

FLECK 5600 WATER SOFTENER INSTALLATION

HydroTap Taps Installation

Cleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features

HWD-2105 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine.

KEG RIVER MICROBREWERY INSTRUCTION MANUAL

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

Horizon Elite Ice Machine Models with RIDE Technology Installation Instructions for Vision

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Click here for a labelled version of above

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

propanel Series Installation Manual

OPERATION MANUAL OPERATION MANUAL FREE. instructional videos are available online at: youtube.com IMPORTANT SAFETY INFORMATION DO NOT DISCARD

5000 Series Bottled Water System by.

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

1-866-PENNERS

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

Zen Boiling Tap Range

Installation Instructions PRO SERIES

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

Installation and Operation Manual MG-304. Please read this manual carefully before use.

CONTEMPORARY KITCHEN AND PREP FAUCET INSTALLATION INSTRUCTIONS

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

ICED CAPPUCCINO MACHINE Taylor MODEL: 390

NELSON HEAT TRACING SYSTEMS

Please FAX or completed form to FWE. KFC Pre-Installation Check Sheet Pre-Installation Information. I t w i l l h e l p u s h e l p y o u!

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units

5700-E Sediment Filter Installation & Start-Up Guide

(12) Patent Application Publication (10) Pub. No.: US 2015/ A1

Installation guide Sahara & Sahara Plus

ELITE (110V) (220V)

INSTALLATION INSTRUCTIONS For The "North" Wood Burning Cook Stove energy saving Hot Water Kit

DURANGO 12V Heater HF

5900S Softener Installation & Start-Up Guide

Horizon Ice Machine Models with RIDE Technology Installation Instructions for Vision

5900-BT Softener Installation & Start-Up Guide

Operator Manual Powdered Beverage Dispensers PIC3, PIC33A, PIC5, PIC6

INTRODUCING: NANO-MAGIC RIMS 2BBL,

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Triple Gel Coat Walk in Tubs A1A Ultimate Edition

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

P200E Shuttle Brewer

Room Air Conditioner Service and Parts Manual

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

Water Distiller Service Manual

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

7800 Neutralizer Installation & Start-Up Guide

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

Transcription:

Spike+ System Product uide ONTNTS: Page : rewing control panel Page : Hot Liquor Tank Page 3: Mash Tun Page : oil Kettle Page 5: Wort hiller Page 6: Pumps Page 7: Hoses

RWN ONTROL PANL Autotune your HLT P efore you get started, make sure that you autotune your HLT P controller. This insures proper calculations resulting in efficient use of the heating element. You only need to do this for your HLT P before your first brew. To auto-tune, bring your kettle to approximately 50 degrees, once close to this temperature follow the bellow steps: Hit set and < (scroll left) and the same time Hit ^ x3, then < x, then ^ x3 to get 0033. Hit set This will bring up ØØ Hit ^ x to get Ø and hit set This will bring up at on top with no in green at the bottom Hit ^ x to change no to yes Hit set and < at the same time ATU will blink on the bottom left of the screen PRO TP: f mounting your panel on the wall we recommend attaching to a piece of plywood and then affixing that to the wall or using a TV mount designed for the weight of the panel.

HOT LQUOR TANK TM SRPTON A.5 T X Q H J.5 T lamp.5 asket.5 T utterfly Valve Spike+ Pickup Tube - Side.5 T HRMS Q Spike+ Pickup Tube - Shorty HRMS oil.5 T lement.5 T Temp Probe J PRO TPS: The clamps only need to be hand tightened to be leak free Make sure the elements are plugged in and the power cords are fully twisted into position, otherwise the resistance is increased which will cause the plug to melt. efore installing the HRMS coil into the quick connect fittings, be sure to lubricate them with water. This will allow them to slide into the Q fitting easily and prevent tearing the o-ring. nstall the bottom of the HRMs coil first and then the top. irmly seat into the lubricated fitting to avoid any leaking

MASH TUN TM SRPTON A.5 T X Q H.5 T lamp.5 asket.5 T utterfly Valve Spike+ Pickup Tube - Side Spike+ Pickup Tube - enter alse ottom.5 T Temp Probe T Tee PRO TPS: The clamps only need to be hand tightened to be leak free We recommend using feet of the silicone tubing to the side pickup tube on the mash tun. The tubing will float on top of the grain bed allowing for a nice, even recirculation over the grain bed.

OL KTTL TM SRPTON A.5 T X Q.5 T lamp.5 asket.5 T utterfly Valve Spike+ Pickup Tube - Side.5 T lement.5 T Temp Probe PRO TPS: The clamps only need to be hand tightened to be leak free Make sure the elements are plugged in and the power cords are fully twisted into position, otherwise the resistance is increased which will cause the plug to melt. The K P is set as a % output control as opposed to temperature control. This allows you to dial in the perfect rolling boil. When installing, the drain pickup should be facing down and whirlpool should be facing counter-clockwise parallel to the bottom of the kettle.

WORT HLLR TM SRPTON A.5 T X Q.5 T lamp.5 asket.5 T Temp Probe T Tee / Hose arb ounterflow hiller PRO TPS: Our chiller is a counterflow chiller design made from super conductive copper. All this adds up to fast chilling speeds. Our chiller comes with Q fittings so you can quickly connect to the rest of your system. t also includes a tee fitting and additional temp probe so you can monitor inline chilling temps going into your fermenter. Simply attach the temp probe cable from your mash tun to the tee on the chiller. You ll be able to see the chiller exit temp via the control panel and adjust the flow rate to achieve your perfect yeast pitch temp. f you have high ground water temps we recommend submerging your chiller in an ice water bath for the last leg of chilling.

PUMPS TM SRPTON A.5 T X Q H J.5 T lamp.5 asket.5 T utterfly Valve.5 T 3pc Valve T Tee Pump Head Screws Pump Head Mounting Nut.5 T arb 0 in out PRO TPS: One pump will need to be rotated 0 if using our Spike System table leg mount. To rotate the pump head, remove the screws, rotate the head 0 and then tighten the screws. This will have both pump heads with the Out at the bottom. When setting up your pumps for the 30 gallon and 50 gallon kettle systems, ensure that you mount the pumps to the center leg so that your hoses will reach from the kettles to the pumps. H J

HOSS () 6 (3) A A () TM SRPTON A Q x arb 0 Long Hose 6 Short Hose Mash Tun Recirculate Hose 3 PRO TP: We use oversized barbs so the silicone tubing will be securely attached without a need for hose clamps. Also, this oversized barb creates a full port which doesn t restrict flow. A A