MICROPROCESSOR RAPPER CONTROL MODEL MRC-NT

Similar documents
FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

Part 3 Troubleshooting

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Container Refrigeration

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Hot Surface Ignition (HSI) System Booklet

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

3.4 SPINDLE AMPLIFIER MODULE

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

PERMACONN PM1030 Includes DI300. Installation Manual

Programmable Load Management Thermostat

/ Marley Collection Basin Heater / User Manual

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SAFEPATH Operation and Installation Manual

Galaxy Pulsar Plus Controller Family Troubleshooting Table with SMNP Traps

Marley Collection Basin Heater Circuit

Q - Series Boiler. Troubleshooting Manual

Model 3300 Technical Support and Installation Manual

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

BGH Series Hot Surface Ignition Control

INSTALLATION MANUAL & PROGRAM RECORD SHEET

I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

ECO N DATE DESCRIPTION OF CHANGE CHG

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

HOME SECURITY MICROPROCESSOR CENTRAL UNIT HOME 5 USER S MANUAL

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Pioneer-R16 Gas Monitor Operator s Manual

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

MARINE FAN COILS INSTALLATION MANUAL

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

Owner s Manual PS-200

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Service Manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Wascator FOM71 CLS Clarus Control

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

Application Manual Loop Water Controller

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

Installation, Operating and Maintenance Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

X64 Wireless Training

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Technical Manual. Level Alarm Unit CARLA & WIDS

SOME OF THE MOST COMMON TESTING MISTAKES MADE BY TECHNICIANS PERFORMING VERIFICATIONS TO CAN/ULC S537-04

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

TS700. Intruder Alarm Control Panel OPEN ENT 0 ESC

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

DIESEL Engine Fire Pump Controllers Features

Part. Test System Weekly See Watch ~Test. Points

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

The CAB & DAB Air Curtains

Installation and Operating Manual

Service Manual Models: 1.0, 1.3, and 1.5

Introduction... 1 System Overview... 1 System Diagram... 2

Product Manual SZ1009

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

WARNING Important Safety Information

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

Trouble Shooting Guide PWA, 3-phase (D10571)

LZP-2 ZONE CONTROL PANEL

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Fire Control Panel FS5100

Fast Track Troubleshooting

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Setup & Operation Index

Halton SAFE / 7.14 user guide and installation instructions

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

WCVD-Series OPL Washers Troubleshooting And Fault Codes. Starting serial number ****** (09/13)

ECE/TRANS/180/Add.5/Amend.1

WCAD-Series Vended Washers Troubleshooting And Fault Codes

Water Source Heat Pump Module Technical Guide

TECH SHEET - DO NOT DISCARD PAGE

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

CG Series Digital Temperature Controller OPERATIONS MANUAL

Public Safety DAS Annunciator Panel

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

Transcription:

MICROPROCESSOR RAPPER CONTROL MODEL MRC-NT TROUBLESHOOTING GUIDE The following troubleshooting instructions are based on controls that have been installed correctly and have operated properly for some period of time. If you are having problems while installing the control, upon initial operation, or if you have followed all the troubleshooting procedures and are still having a problem, please us at 908-874-5588.

ALARM DEFINITIONS AND DESCRIPTIONS If an alarm message appears in the display, either a malfunction has occurred, or the control is being operated in other than a normal manner. A rapper is automatically disabled when the control senses improper levels of current. A rapper is disabled the second consecutive time the fault occurs. This prevents a rapper from being disabled due to electrical noise. Whenever a failure is associated with an individual rapper, the device is automatically disabled from the control. Repetitive alarms will not occur because the logic circuit will not call for the disabled device to be energized. The control will continue to operate as programmed for all the remaining devices. A device may be placed back in operation by using the ENABLE key (follow instructions in operating manual). If the problem associated with the device is still present, the control will re-alarm after the device has been energized twice. By pressing the Alarm Check Key the number of the disabled device(s) is displayed. Repetitive keying of the Alarm Check key will cause alarmed devices to be displayed, one at a time, in sequential order. The alarm messages are as follows: Low Level Alarm - Open Rapper Coil or Line Medium Level Alarm - 2 Rappers Firing due to Shorted Output High Level Alarm - Shorted Rapper Coil or field wiring Sequence Mode -The control has been programmed to operate in the Sequence mode. Repeat Mode - The control has been programmed to operate in the Repeat mode. Communications Error - Communications error has occurred between the Keypad & Display Unit and the Power Board. Page 2 of 2

RAPPER ALARM TROUBLE SHOOTING PROCEDURES Rapper alarms are determined by monitoring the voltage across the current sensing resistors located on the rapper power module. When a rapper fires, the rapper power board measures the voltage across this resistor. Depending on this voltage the rapper control will perform one of the following operations. Normal operation If the voltage across the current monitoring resistor is acceptable, the control will allow the rapper to fire. Low Level Alarm When a rapper fires and there is less than the normal voltage (note: This voltage signal is only 167 ms long. It is necessary to use an oscilloscope to measure the peak-to-peak value across the current sensing resistor.) the control will store this specific device ID in memory. When this device ID comes due to energize again the control will again monitor the voltage across the current sensing resistor. If this voltage has remained below the normal voltage, the control will display a Low Level Alarm. If the voltage is acceptable during the second energization, then the control will erase this ID from memory and continue on. Items that can cause Low Level Alarms are: 1. All or almost all rappers have Low Level alarmed. Blown control fuses or a failed Power Module or Power Board. To determine which has failed, you will need to monitor the fire LED on the Power Board. If this fire LED blinks when the control tries to fire a device then the Power Board is functioning properly. You should next check the fuses and supply transformer associated with the power system in question. If all these item check out OK, then replace the associated Power Module. 2. One or few devices have Low Level alarmed. At the control field wiring terminal points, and with the control power off, check for resistance between the common return and the devices in question. Depending on the manufacturer of the rapper and the field wiring resistance, this resistance should be approximately 4.0 ohms. If the circuit is open, then check for this resistance at the rapper assembly. This will verify if the device is open, or the field wiring is open. If device and field wiring checks verify that everything is OK, replace the Output Board(s) associated with the failed device(s). Page 3 of 3

Medium Level Alarm When a device energizes and the voltage across the current sensing resistor is more than the normal voltage but less than High Level Alarm voltage, for two consecutive energization attempts, the rapper control will display a Medium Level Alarm and will take this device out of service. During the first two attempts to fire a device under this condition, the control will only fire for 4 half cycles. This is to protect the components of the control from high current. After correcting the alarm condition an operator must clear the alarm (see operation manual). Items that can cause Medium Level Alarms are: 1. Two devices firing at one time. This is the result of a shorted steering SCR/triac on one or more Output Boards. This sometimes can be difficult to trouble shoot. First clear all alarms. Then enable the Sequence All function of the rapper control. Allow the rapper control to sequence through the entire program twice. After the control has sequenced through twice you should find that all the devices except one has a Medium Level Alarm (use the Alarm Check key to show alarmed devices). The device that has not shown a Medium Level Alarm is located on the defective output board. This is because the shorted steering SCR/triac is firing this device whenever any other device fires. Thus causing the control to think the other devices are shorted. But when the device with the shorted steering SCR/triac is due to fire, it fires by itself thus not drawing excessive current. 2. Excessive electrical noise. This is generally associated with random Medium Level Alarms. Poor or no grounding of rapper rods and rapper housings can cause electrical noise to travel from the precipitator thru the rapper coil and into the control. This noise fools the control by raising the voltage across the current sensing resistor to alarm levels. Just one poor ground can cause this condition, so it s very important to check all grounds and replace or repair any that are defective. High Level Alarm This condition is similar to a Medium Level Alarm but is the result of the voltage across the current sensing resistor exceeding the Medium Level Alarm voltage. When this condition is present the control will only fire for 1 half cycle. This is to protect the components from excessive current. Items that can cause High Level Alarms are: 1. Shorted Rapper Coil. Check the resistance of the rapper coil in question and compare it to the manufacturer's specification. Remember to allow for filed wiring resistance when measuring at the control cabinet. Page 4 of 4

Communications Error Problem: Loss of communication between Keypad And Display Unit and Power Board. Items that can cause Communication alarm are: 1. Improper connection of communication cable at either end. 2. Damaged communication cable. 3. ID switch on the Power Board is set incorrectly. 3. Defective Power Board. 4. Defective Keypad And Display Unit. Waveforms The oscilloscope waveforms shown on the next four pages show the voltage waveform across the current sensing resistor for normal and abnormal control operating conditions. Use them as a guide in troubleshooting the control. Page 5 of 5

Normal Operation Waveform Vertical = 1 volt/division Horizontal = 5 ms/division Oscilloscope waveform obtained across the current sensing resistor on the Power Module showing normal and proper rapper energization. Page 6 of 6

Half Wave Operation Vertical = 1 volt/division Horizontal = 5 ms/division Oscilloscope waveform obtained across the current sensing resistor on the Power Module showing one SCR not firing or a blown fuse. Page 7 of 7

Medium Level Alarm Vertical = 1 volt/division Horizontal = 5 ms/division Oscilloscope waveform obtained across the current sensing resistor on the Power Module showing two rappers firing at the same time. Page 8 of 8

High Level Alarm Vertical = 1 volt/division Horizontal = 5 ms/division Oscilloscope waveform obtained across the current sensing resistor on the Power Module showing an High Level Alarm (electrical short) condition. Page 9 of 9