Description RECESSED SURFACE SUSPENSION UP & DOWN Fun with magnets and light. Simultaneously graphic and subtle, the Running Magnet is flexible, precise, and as creative as you. It is track lighting redesigned and elegantly refined. Light elements snap in place and connect automatically though the magic of magnets. Extruded aluminum housings create a clean 1-3/8-inch slot and preconfigured corners complete the system that can run up, around and across walls and ceilings. es align perfectly. Linear LED and accent fixtures, available in a variety of sizes, can be exchanged and repositioned quickly, without tools, with artistic results. The Running Magnet is perfect for retail displays where frequent changes are typical and absolute performance is mandatory. Lamps Up Light: 2.5W/ft, 288lm/ft, K, 80 Multi Spot: 10W, 4x210lm, K, 80 10W, 4x210m, K, 80 Mini Glo-ball: 7W, 800lm, K, 80 7W, 880lm, K, 80 Mini Glo-Ball S: 3.5W, 400lm, K, 80 3.5W, 440lm, K, 80 Find Me Suspension: 8W, 560lm, K, 8W, 600lm, K, Spot Module: 8W, 600lm, K, 8W, 550lm, K, Light Strip, 11.8 : 7.5W, 460lm, K, 7.5W, 435lm, K, Light Strip 23.6 : 15W, 920lm, K, 15W, 870lm, K, Light Strip 35.4 : 22.5W, 1380lm, K, 22.5W, 1305lm, K, Light Strip 47.2 : 30W, 1840lm, K, 30W, 1740lm, K, Spot 120: 12.5W, 1060lm, K, 12.5W, 985lm, K, Anthony Spot: 16W, 1404lm, K, 16W, 1310lm, K, Photometrics For current IES files please visit architectural.flosusa.com Construction Extruded aluminum housing with integral DALI controllable track system. 13 of suspension aircraft cable is standard. Electrical 24V electrical systemlimited to a maximum load of 4A and 100W per driver. Spot and linear luminaires available with individually addressable DALI circuitry, 0-10V Dimming (from 10% up to 100%) or builtin dimmer on each fixture head. 0-10V Fixtures come from the factory set up at the lowest level 10% they always required a 0-10V signal to achieve the maximum output. EC to supply site cabling from driver to track location and site UL listed enclosure. Suspension Up&Down Profile Up&Down profiles are not cutable. Linear profiles available as feed profiles to connect to a driver and intermediate profiles to fill in remaining lengths. Trimless extruded aluminum profile to be surface mounted on ceilings. Linear profiles available as feed profiles to connect to a driver and intermediate profiles to fill in remaining lengths. Each feed profile comes with two end caps. Available lengths: 39.4, 59, 78.7 and 98.4 Corners available for continuous runs. Track can not be powered through corners. The corners are not fitted with indirect ilumination. Notes Consult factory for other ceiling types including accoustic tile ceilings and wood. Listings: UL Listed, IP20 dry location only, Class 2, Meets California standards for commercial interiors. Warranty 2 years from date of sale. Page 1 of 10
Luminaries Light Strip Module HE Spot Module Multi Spot Spot 120 Find Me Suspension Anthony Spot Track Mini Glo-Ball Mini Glo-Ball Suspension 0 3 7 0 0 0 1 4 9 0 Dimming Protocol or Variant Page 2 of 10
Profiles The extruded aluminum housing creates a clean 1-3/8 slot that can be run up, around and across walls and ceilings. Vertical and horizontal corners complete the system. The magnetic luminaries are simply installed by insertion. Linear tracks are available in two versions: power feed profiles for connecting to a driver, and intermediate profiles. End caps and connection cables are included with each power feed profile. Internal foam for opening support should not be removed until after installation. DETAIL A L DETAIL A 1.6 [40mm] SECTION : Remote SECTION : Surface mounted Canopy 5 [127mm] 0.6 [15mm] 2.5 [63.5mm] 4.5 [114mm] STAINLESS STEEL CABLE ENDCAP 0.14 [4mm] 3.9 [100mm] 1.4 [35mm] MAX 157.4 [4000mm] STAINLESS STEEL CABLE MAX 157.4 [4000mm] FIELD ADJUSTABE LENGHT 3.9 [100mm] CEILING MOUNT TO DRIVER CANOPY 1.4 [35mm] 1.6 [40mm] 1.6 [40mm] ex. 06.1614.40. Length Feed Unit Profile Intermediate Profile Delivered lumens Up Light Variant 39.4 (1 m) 06.1614 06.1619 631 lm 59 (1.5 m) 78.7 (2 m) 06.1615 06.1616 06.1620 947 lm 06.1621 1262 lm. = UL version 98.4 (2.5 m) 06.1617 06.1622 1578 lm Page 3 of 10
Corners Horizontal Corner 5.9 5.9 ex. 06.1624.40. Dimension º corner Variant 5.9 x 5.9 06.1624. = UL version 4.6 Optional Accesories Description Image QTY Endcaps The Endcap come as standard with the feed profile. Part number to be order in case of loss or if the installation is exclusively composed of intermediate elements.. End connector included 08.8887 08.8887 Cover Plate For remote installations 4.5 RM -C -B (Black) RM -C -W (White) 0.3 Dimming controllers Image QTY Description Drawing 08.0613.14A Dimming Control Unit Box 24V 0-10V Required for a 0-10V Dimming installation. 1 DCU can control up to 25 fixtures 2.14 3,3 0.66 Page 4 of 10
Required Drivers Image QTY Item Number Description Drawing LEDSB96W24V-NDM-D01 24V/96W, 120-277V, Magnitude, UL Listed 12.1 7.4 1.4 LEDSB60W24V-NDM-D01 24V/60W, 120-277V, Magnitude, UL Listed 6.8 11.7 1.45 2.36 LEDSB30W24V-NDM-D01 24V/30W, 120-277V, Magnitude, UL Listed 1.37 7.12 11.4 59.82 LEDSB96W24V-NDM-U01 24V/96W, 120-277V, ERP, UL Listed 102.6 205.2 LEDSB60W24V-NDM-U01 24V/60W, 120-277V, ERP, UL Listed 75.18 24.9 LEDSB40W24V-NDM-U01 24V/40W, 120-277V, ERP, UL Listed 3,3 4.5 08U0004.14 08U0004.30 Surface mount canopy Non Dimmable for Running Magnet Suspension Up&Down includes: 2 drivers: 96W, 24V, 120-277VAC input, UL listed 12.5 2.2 4.5 08U0004.14A1V 08U0004.30A1V Surface mount canopy Dimmable for Running Magnet Suspension Up&Down includes: 2 drivers: 96W, 24V, 120-277VAC input, UL listed 1 Dimming Control Unit Box: 08.0613.14A 12.5 2.2 Page 5 of 10
Light Strip Module HE Linear High Efficency LED can be rapidly exchanged and repositioned without tools. Light elements are quick to position and connect automatically with magnets. Built-in dimming knob dims fixture from 20-100%, DALI and 0-10V from 10-100%. Clear end caps included for continuous look when installing end-to-end. 2.8 SEE TABLE 1.3 ex. 03.7001.14. Light Strip Length Initial Delivered Beam Dimming Protocol 11.8 (300mm) 460 435 440 435 7.5W 105º 03.7001 03.7000 23.6 (600mm) 35.4 (0mm) 920 870 1380 1305 880 833 1320 1249 15W 105º 22.5W 105º 03.7003 03.7002 03.7005 03.7004. = Dimmable on board.dd = DALI.9V = 0-10V 47.2 (1200mm) 1840 1740 1760 1665 30W 105º 03.7007 03.7006 Spot Module Accent LED Spot modules can be rapidly exchanged and repositioned without tools. Light elements are quick to position and connect automatically with magnets. Built-in dimming knob dims fixture from 20-100%, DALI and 0-10V (from 10-100%). Standard beam spread is 14. Additional interchangeable lenses available in 23 and 33, and 10 x 40 elliptical beam spread. ex. 03.6302.14A Initial Delivered Beam Dimming Protocol 600 418 8W 14º 03.6302 A = Dimmable on board ADD = DALI 550 404 8W 14º 03.6303 A9V = 0-10V 5.16 Optional Accessories Image Description º 1.97 08.8760.00 Flood Lens Accessory 23 ø 1.34 08.8761.00 Wide Flood Lens Accessory 33 360º 08.8759.00 Elliptical Lens Accessory 6.7 08.8427.14 Extra long snoot for added shielding in aluminum with black finish (does not protude from channel when tucked up into housing) Page 6 of 10
Multi Spot 4 4 accent Spot LED module can be rapidly exchanged and repositioned without tools. Light elements are quick to position and connect automatically with magnets. Built-in dimming knob dims fixture (from 20-100%), DALI and 0-10V (from 10-100%). Standard beam spread is 14 additional interchangeable lenses available in 20 and 30, and elliptical beam spread ex. 03.6306.14. Initial Delivered Beam Dimming Protocol 4 X 210 674 10W 11º 03.6306. = Dimmable on board.dd = DALI 4 X 210 630 10W 11º 03.6305.9V = 0-10V Optional Accessories Image Description 2.7 1.3 08.8760.00 Flood Lens Accessory 20 4.8 08.8761.00 Wide Flood Lens Accessory 30 4.7 08.8759.00 Elliptical Lens Accessory Spot 120 Accent lighting LED module to be installed in The Running Magnet 2.0 System. Built-in DC/DC electronic voltage converter. Built-in dimming knob on board fixture (from 39-100%), DALI and 0-10V (from 10-100%) Standard beam spread are 25º and 33º. Honeycomb and cross baffle included. ex. 03.6285.14. Initial Delivered * Beam 0-10V Dimming 985 706 03.6285 12.5W 14W 25º 1060 985 731 430 03.6284 03.6286. = Dimmable on board (12.5W).DD = DALI (14W).9V = 0-10V (14W) 1.57 5.1 0.87 1060 444 12.5W 14W 33º 03.6287 * Dimmable on board 12.5W, DALI and 0-10V Dimming fixtures are 14W 7.87 ø 1.8 Page 7 of 10
Anthony Spot Accent lighting LED module to be installed in The Running Magnet 2.0 System. Built-in DC/DC electronic voltage converter. Built-in dimming knob on board fixture (from 39-100%), DALI and 0-10V (from 10-100%) Standard beam spread are 15º and 22º. ex. 03.6277.14. Initial 1310 Delivered 1010 16W Beam 15º 03.6277 Dimming Protocol 130 22 1404 1310 1085 1052 16W 16W 15º 22º 03.6274 03.6278 A = Dimmable on board ADD = DALI A9V = 0-10V 40 1404 1129 16W 22º 03.6275 165 ø 110 Optional Accessories Image Description 08.8418.68A Elliptical lens 08.8419.14A Honeycomb 08.0050.00 Flood lens. To obtain flood optics (35º) order Anthony Spot Medium + flood lens. Page 8 of 10
Other Light Module Decorative modules can be rapidly exchanged and repositioned without tools. Light elements are quick to position and connect automatically through the magic of magnets. Built-in dimming knob allows fixture to dim from 20-100%, DALI and 0-10V from 10-100%. Mini Glo -Ball Mini Glo - Ball Suspension Find Me Suspension 5.11 5.07 5.11 2.8 2.8 2.8 118 [ mm] MAX. 118 [ mm] MAX. 3.3 ø 4.3 8.7 3.6 ø 4.3 ø 1.3 ex. 03.6260.30B Initial s Delivered s Dimming Protocol Mini Glo - Ball 80 80 880 800 528 488 7W 7W 03.6261 03.6260 B = Dimmable on board.dd = DALI.9V = 0-10V ex. 03.6263.30B Initial s Delivered s Dimming Protocol Mini Glo - Ball Suspension 80 80 440 400 271 259 3.5W 3.5W 03.6263 03.6262 B = Dimmable on board.dd = DALI.9V = 0-10V ex. 03.6273.30C Initial Delivered Beam Dimming Protocol 600 365 8W 14º 03.6273 30 = White C = Dimmable on board Find Me Suspension.DD = DALI 560 344 8W 14º 03.6272 06 = Chrome.9V = 0-10V Page 9 of 10
A. Select and position corners Horizontal - Connect sections on flat surfaces ( corner) C. Driver/ Canopy Quantity of drivers determined by total wattage or light elements in section (approximately one every 10 feet). Maximum driver distance is 15. Locate drivers nearby. Dimming hardwires into profile, bypasses driver. B. Fill lengths between corners with Linear Housings 3.3, 4.9, 6.6 or 8.2 sections can be specif ied as feed or intermediate profiles. Up&Down profile can not be cut. D. Select Light Modules Linear strips are available in five nominal lengths: 1, 2, 3, 4 and 5. Individual units can be adjusted from 20-100% with a built-in dimming knob and DALI and 0-10V from 10-100% Visit FLOS Worldwide YouTube channel for installation videos Page 10 of 10