AIR CONDITIONER POWER PLANT

Similar documents
Teknogen. Contents. Air Handling Unit Casing of the Unit Fan / Motor Damper Filter Cells Heating / Cooling Coil...

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Centeral Station Air Handling Unit

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

VERSO Air Handling Units

AIR HANDLING UNITS. Revision AG 16-07

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

Double Skin Casing Air Handling Units

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

The ultimate in air handling units: directly and indirectly fired

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

VERSO Air Handling Units

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

39G Air Handling Unit


AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Enjoy the Delighting Comfort Brought by High Air Quality

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Ultimate energy saving technology

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

13 HYGENIC AIR HANDLING UNITS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

The ultimate in air handling units: directly and indirectly fired

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Double Skin Air Handling Units

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Air Handling Units. Real HVACR people who understand your needs.

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

The ultimate in air handling units: directly and indirectly fired

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

next p dw next p dw rcgroupairconditioning

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

The ultimate in air handling units: directly and indirectly fired

Air Handling Unit. Air Handling Unit

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

EUROVENT certified Air Handling Units:

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Ultimate energy saving technology

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

NEXT DL NEXT DL. rcgroupairconditioning

CHAPTER 4. HVAC DELIVERY SYSTEMS

Easdale International INFINITY

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Package Hygienic Air Handling Units. PHK Series

ULTIMATE ENERGY SAVING TECHNOLOGY

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

KELVIN Clim F497. Kelvin air conditioning

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

AIR HANDLING UNITS MANDÍK

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

TYPICAL CPA SPECIFICATIONS

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Double Skin Air Handling Units

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

1.1 This section applies to air handling units for HVAC Systems.

USE sizes Horizontal and vertical versions Single or double flow arrangement (side by side or superimposed)

ALL PRODUCTS BROCHURE

39 HQ Air Handling Units AiroVision

CHAPTER 6 CONDENSING UNITS

Chapter-8 Capacity Control of Refrigeration Systems

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

AHU Plus. DX Air Handling Units

CONTACT US. For more information,

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

DIVISION 15 MECHANICAL

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

CENTRAL SPLIT UNIT UNIC

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Cert. n Air Conditioning Vulcan Pro Air Handling Units

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

Heat pump and energy recovery systems

lindab we simplify construction Lindab Modular air handling units Connection, start-up and commissioning manual

Main technical datas:

Transcription:

AIR CONDITIONER POWER PLANT

GENERAL FEATURES GENERAL FEATURES Fantürk air conditioner power plants are produced 28 different sections. Flow range is between 900 m3/h -145.000 m3/h for refrigeration and ventilation. Aim of heating, flow range is between 900m3/h-194.000 m3/h. Fantürk air conditioner power plants are modular structure and have double paries board. According to request and implementation, Rockwool,glass woolor or polyurethane isolation panels can be produced like 50 mm or 60 mm gauge. Outer surface is coloured metal sheet which is RAL 9002. Metal sheet can be used galvanization or stainless related to requested or implementation Outer surface is smooth and ıt can be clean very easily and prevented dust deposit Fantürk air conditioner power plants framewok are consisted of strong structure with electrostatics klin coloured aliminium side view and plastic link components. Filter option should be chosen regarding to using environment and requirement of process. High efficieny can be get in filter and streamer owing to avoid leakage with special design Nowadays, Depending to requesting, Plate, impeller or battery type of heat recycling units are used Ventilator motot group can be chosen in such a manner efficiency aim to pay attention to air flow and total static pressure. According to aim of usage and design criterias, ıt can be selected stoop compact wing,airfoil or plug type. approved fan is used in performance test. Motors are in IP55 class. And these are suitable CE norms Tipping bodies ( using for air condition power plant ) are produced with using aliminium profil, aliminium wing and plastic gear. Gear is out of air flow.special shaped plastic gasket and tipping are impermeable

Program of chosing air conditioner power plants Fantürk air conditioner power plant program is about chosing of power plants, sizing of power plant, performance and technic datas With this program, you can unify your specifing materails,items and It gives us change to create your device. For each items, you can determine accessories. In selecting each items, You can see brand and model alternatives with price option. *Inside of option,you can select the best things as efficiency,price etc and You can also designate how many pieces are consist of your device as well as cell shape. *you can find technic report which is related to price, sized picture, device information. Fantürk power plant section and flow

FANTURK AIR CONDITIONER POWER PLANT MEASUREMENT

Quick Selection Table

Each detail has functionality and quality... TAPE Structure Special aliminium profile, interim profiler, panel are used in Fantürk air conditioner power plant. Aliminiun profiles are resistant to corrosion.profiles are consolidated with speacial designed plastic corners. Panels are standart size.and double size-partition and Rockwool,glass woolor or polyurethane are used for isolation Panels thickness are 50 mm or 60 mm. Panels outer tin plate is standardized RAL 9002 colour, and ıts inner side is produced stainless, galvanization colured tin plate tin plate s thickness is between 0,8-1,2 mm. Panels are detachable from outside of station. Plants are totaly plane. Panels are directly contacted with special screws to profile EPDM Sealant gaskets are glued between panels and profiles Between panels, interval profiles are used Isolation materials are filled with interval profiles On station, impermeadable sealed service door are built for essential areas. Upon your request, It can be also produced as observation glass The power plants base, according to power plants size, ıt can be one piece or partial with on the basis of cell. Air conditioner power plant is 100mm in low pressure, 150 mm in high pressure.for moving easily, there are pedestal removal holes Vehicles for using outside which can be proctected with special designed roof Power plant can carry out building site or partial or one- piece to provice convenience. Cells can be combined with special connection materials ACCESSORIES Lighting, observation glass, manometer, flexible joint, siphon, maitenance switch, damper motor, water protecting are used in air conditioner power plants.

FILTERS Fantürk air conditioner power plants s section complies with quality standards which are used in the sytyle of transition area. Filters can be removed easily thanks to casette type. Air leakage is prevented by approciate design.service door in the fitler cells are used for maintenance and replacement. Lighting, observation glass, manometer are used optionally. The importance of indoor air quality in air conditioninig plants are taken Different type or different efficiency filters are used.generally, type of filters are panel filter, bag fitler,metal filter, activated carbon filter, compact filter, hepa filter.panel filters are used as pre-filter. Filter materials are synthetict or metal. Panel Filters are used as pre-filter. Filter material is metallic or synthetic. Metal filters have an oil retention properties. We use filter classes; For synthetic materials : G2, G3, G4, metallic material To: G2, G3 For high-efficiency air filtration bag filters are used. Dust capacity is high. They should be used together with a filter for the Increase of the interior life. Boy bags by the air flow are 305 mm, 508 mm, 635 mm, as it varies.we use filter classes; G4, F5, F6, F7, F8 Compact filters are highly efficient filter. It should be used in conjunction with a prefilter. It has less space in exchange for that depth is 292 mm. Distribute air evenly to the filter construction is possible because the entire filter surface. filter class is used; F6, F7, F8, and F9. HEPA filters are used for hygienic environments. Efficiencies are very high. These filters are mounted after the fans must be used and necessarily with a prefilter. filter class used; H10, H12, H13, H14, respectively Activated carbon filters are used to soak in the air malodorous gas or vapor molecules ( exhaust fumes, the smell of rubber, alcohol, hydrocarbon, chlorine, and other chemicals, such as the odor from the manufacturing process). Hydrogen sulfide, sulfur dioxide, etc. As an alternative model is available for the absorption of the odor of other industrial processes, it should be used with a pre-filter to increase the service life. Suction -Mix- blowing Cells Damper sections are dimensioned in accordance with the air velocity. As standard ; aerofoil structure, the dampers are used opposite wing. Dump tape and wings of the material is aluminum. sealing air leaks using the blade edges are minimized. Dampers are manufactured according to the manual, or servo - motor control. Optional servomotor, rain protection and flexible connections can be installed. Damper sizes are standardized according to the type of plant has been designed to spend 100% air flow.

Heat Recovery System Today, energy efficiency is of paramount importance. Therefore, central air conditioning heat began to be preferred to use the recycling unit. Fantürk central air conditioning coil, plate and rotary heat recovery units are used. Overall yield; the coil type heat recovery units, 30-50 %, 40-60% in the plate type, rotor type is 60-80 % Streamer Heat Recovery Double coil heat transfer and heat recovery coil in the exhaust and fresh air exchange is carried out through the fluid circulating in a closed circuit. Heat transfer from the air to water - water to air is performed. intermingling of fresh air and exhaust air is not in question. Ethylene glycol is used in areas with the risk of freezing. The circulation pump in the system and there is a need to balance tank. The exhaust side of the condensate pan is used. Plate Heat Recovery Cross-flow plate heat recovery elements, without having moving parts between fresh air and exhaust air to provide heat transfer. even at high pressure difference can be provided complete seal. It can operate between -30 C to 90 C. Aluminum plates, are made of epoxy-coated aluminum or stainless steel. To prevent freezing at low temperatures are manufactured by-pass damper. The exhaust side, A drain pan is mounted against condensation can occur. Rotary Heat Recovery They have a compact design and high thermal performance. heat transfer sheet with an aluminum plate on a wavy appearance when placed in a rotor is performed. V-belts driven rotor rotation is provided by an electric motor. Generally can be grouped into 3 types 1 - Condensation Heat Wheels: In standard comfort ventilation, heat by condensing the water vapor in the air drained is low-cost solution that enables recovery. 2) Heat - moisture-absorbing wheels: Standard comfort air conditioning applications, and humidity makes the heat transfer wheels with a special surface in the appropriate temperature range. 3)Entalpy heat wheels In climates with high temperature and humidity conditions are preferred. Dessikant padded surface coated with substances with moisture transfer in higher amounts. With pre-cooling and dehumidifying feature reduces energy spent on cooling. Thus, the smaller capacity chillers provide a significant amount of energy is used. Fill diameter is between 250-5000 mm. less space due to its compact structure. The temperature efficiency of the thermal wheels minutes 12 d / d are optimized according to the rotation speed.

It is increased by the application. If desired capacity controlled by the variable climates frequency converter speed control is performed. The request must be submitted in order of capacity control. There is a risk of freezing. Determination of the rotor air handling fan Location General features Fantürk air handling units are manufactured in 28 different sections. Flow range is 900 m3 / h - 145, 000 m3 / h for cooling and ventilation purposes.only for heating plants, that is 900-194000 m3 / h Fan position, Differential Pressure Zone and Sweep

Moisturizer The spot to the desired moisture content is achieved by moisturizers. Fantürk types of steamy air handling, filling type, isothermal gas-guzzling and atomizer humidification units are used. Steam Humidifiers It generates heat with electricity Electric Heater Fantürk electric heater is used as optional air conditioning plant. Risk of freezing is used in power plants in regions with high inputs. It is also used in power plants in sensitive systems that need immediate heating output. Electrical heating tape galvanized or optionally is manufactured from stainless steel. Elements are stainless steel. Protection class is IP43, respectively. Gradual or proportional control can be performed. It has CE certificate. automatic reset limit thermostat and heater as standard with manual reset safety thermostat is located. If the heater is recommended for 2-3 minutes more fans after stopping operation of the power plant it is over 30 kw of heat energy. Central air conditioning electric heater in the study or the fan is running at very low speed (1.5 m / six ) cases, it is imperative to take measures to prevent abandonment of the electric heater Heating and Cooling Coils Heating and cooling is performed with coils. Serpentine copper or steel pipes, wings aluminum, copper, steel, epoxy-coated aluminum or copper may be coated with epoxy. Direct expansion coils are manufactured from copper a tube collectors are copper and aluminum fin Serpentine tray is made of galvanized steel sheet. The test pressure is 20 bar. Hot and cold water pipe inlet - outlet of gear in coils ; angry water and steam coils, pipes and input and output mouth is flanged. It is produced so that it can easily be taken out for maintenance. Special bypass sheet with only air to pass through the coil surface. Air and water is designed as reverse flow for improved efficiency. Hot and cold water coils, water inlet from the bottom, the water outlet is over the top. Cooling coils inside the drain pan through the flush -mounted panel coil surface area is made available in an efficient manner. Condensate pan is manufactured from stainless steel dual slope. separator used to hold condensed water from the air after cooling coils. Serpentine and Service Aspects from mains water. Microprocessor controlled. Moisture vapor from the unit performs humidification with the help of steam distribution pipes in the plant. On-Off or proportional control staff from 1.5 to 130 kg / h, there are many models in the range.

Fillet Type of Humidifiers Evaporative humidifier air is passed through the wet pad. It soaked through circulation pump filling system. the level of efficiency of the humidifier used is 65% to 85% to 95%. 3.5 m / s in air speed above the humidifier cell separator is placed. Isothermal Gas Fired Humidifiers Thanks to Isothermal humidifiers Gas-fired gas burning compact structure, Isothermal vapor can produce. changing parts during assembly natural gas (G20 or G25), propane (G30) or butane (G31) can be burned. Isothermal steam humidifiers are installed outside and plant produced steam is directed into central steam distribution pipes. Atomizer humidifiers are very low energy consuming large quantities of steam generating device. -60 100 kg / h are models in the range. Proportional running, these devices are capable of connecting to multiple air handling units. It works with demineralized water. Water is sprayed through the spray to the pressure up to 75 bar and thus ensure that the air is completely involved. Per liter / hour spends about 4 watts of energy for humidification. The system conforms to DIN 1946 standards of hygiene. Such emollients are used by adiabatic cooling. Equipment : Frequency controlled pump Drain valves Control unit Stainless steel pulverizer Distribution pipes drift eliminators, Automatic column valves Silencers The noise level is of great importance in ventilation systems, silencers is reduced to help locality acceptable level. sound absorption coefficient varies according to the length of the muffler silencer used. Muffler cell galvanized or stainless steel sheets into rock wool consists of set out backstage. Muffler elements 20m / s is designed to deform the air speed. Fantürk air handling There are 6 different size silencer. Sound absorption capacity are given in the following table according to the size silencer. Sound Absorption Capacity Size by Silencer

Fans and Motors Each section in the various fan types in accordance with the air flow and total pressure drop is presented. International standards suitable for static and dynamic balancing of purpose and fans were tilted forward, depending on the customer s request, can be tilted backward or airfoil blades. Fan- motor group, depending on the total air volume and static pressure efficiency, low noise levels and minimum energy consumption is selected considering. fan - motor assembly for preventing the vibration device is connected with the spring isolator. Bush as standard in our apparatus, fixed diameter pulleys are used optionally variable diameter pulleys may also be used. SPZ, SPA, SPB and SPC belt types are available. Tensioning of the strap is provided with a special mechanism. The fans for service and maintenance cell has a service door safety shield. Special cases are plug type fans are used motor is directly coupled. Engines are IP55 protection class as standard, it complies with CE norms. The standard single speed motors, can also be used as optional double speed motors. frequency converters are available as accessories for motor speed control Fan Operating Modes Diffuser Diffusers; then from fans, filters, coil, the air in the presence of elements such as silencers are used to provide a homogeneous distribution on these elements.