an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

Similar documents
an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

an ISO9001 company APPLICATION NOTES FOR TGS2610 Application Notes for LP Gas Detectors using TGS2610

an ISO9001 company APPLICATION NOTES FOR TGS2611 Application Notes for Methane Gas Detectors using TGS2611

TGS for the detection of Carbon Monoxide

TECHNICAL DATA MQ-2 GAS SENSOR

Web Site: Forums: forums.parallax.com Sales: Technical:

The MiCS-5524 is a compact MOS sensor.

The MiCS-4514 is a compact MOS sensor with two fully independent sensing elements on one package.

Ozone Gas Sensor. (Model:MQ131 High Concentration) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co.

Smoke Sensor. (Model:MQ-2) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

IR25 Dual Gas Series Datasheet

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Ammonia Gas Sensor. (Model:MQ137) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

IR15 Dual Gas Series Datasheet

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

MEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

The MiCS-6814 is a compact MOS sensor with three fully independent sensing elements on one package.

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

The MiCS-6814 is a compact MOS sensor with three fully independent sensing elements on one package.

ACCURATE ELECTRONICS INC

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

ExplorIR -M CO2 Sensor

VQ500 Series Combustible Gas Detector Elements

The MiCS-5524 is a compact MOS sensor.

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

IR1 Single Gas Series Datasheet

IRceL CH4 Methane (CH 4

Lamp Supply (Recommended)

Air-Quality Gas Sensor (Model: MP905) Manual. Version:1.1. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

AUR300C. Advanced Ultraviolet Burner Controller

SprintIR -W CO2 Sensor

ExplorIR -W CO2 Sensor

Thermopile Sensor TPS 230 / 3365

GAS MONITOR Model Model

-smartgas- A new low cost infrared gas sensor for domestic and automotive applications

Heated tools. Semiconductor equipment

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Air-Quality Gas Sensor (Model:MP503) Manual. Version:1.3. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

CMF, CMX & CMA series

Technical Specifications and User Guide for the GDCO Detector

Gas Analyzing System Based on Semiconductor Sensors for Providing Safety of Oil And Gas Pipeline Operations

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Datasheet. CozIR -A CO2 Sensor. Tel: +44 (0)

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

99 Washington Street Melrose, MA Phone Toll Free Visit us at

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

Operation and Maintenance Manual

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

NTC THERMISTOR SENSOR PERFORMANCE

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

NGD8800 USER S MANUAL

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

Advanced Ultraviolet Burner Controller

General Specifications

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

SP-220. Features. Combustible handheld gas leakage detector

Wood pellet and biomass system ceramic igniter

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

ESD500. ESD500 Combustible / Toxic Gas Detector

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

INSTRUCTION MANUAL (ATEX / IECEx)

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

KAE Gas Alarm Operation Manual

APPLICATION DATA SHEET

Mounting Instruction

KANE-ALERT-CO 2 Monitor with Temperature

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Flameproof Type Light Curtain Type 4

PREMIER PLATINUM INFRARED GAS SENSOR

Fire Alarm System Accessories

Features. Applications

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

FIS SMART SENSOR U (Draft 1) June 25, 2001

ESD3000 ESD200 Combustible / Toxic Gas Detector

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Fire Alarm System Accessories

Transcription:

TECHNICAL INFORMATION FOR TGS83 an ISO900 company Technical Information for Combustible Gas Sensors Figaro TGS 8-series sensors are a type of sintered bulk metal oxide semiconductor which offer low cost, long life, and good sensitivity to target gases while utilizing a simple electrical circuit. The TGS83 displays high selectivity and sensitivity to LP Gas and methane. Page Specifications Features...2 Applications...2 Structure...2 Basic measuring circuit...2 Circuit & operating conditions...3 Specifications...3 Dimensions...3 Basic Sensitivity Characteristics Sensitivity to various gases...4 Temperature and humidity dependency...5 Heater voltage dependency...6 Gas response...6 Initial action...7 Long term characteristics...7 See also Technical Brochure Technical Information on Usage of TGS Sensors for Toxic and Explosive Gas Leak Detectors. IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER S SPECIFIC APPLICATIONS. FIGARO STRONGLY RECOMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER S TARGET GASES ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS NOT BEEN SPECIFICALLY TESTED BY FIGARO. Revised 9/99

TECHNICAL INFORMATION FOR TGS83. Specifications - Features * General purpose sensor for a wide range of combustible gases * High sensitivity to LP gas and methane * Low cost * Long life * Uses simple electrical circuit -2 Applications * Domestic gas leak detectors and alarms * Recreational vehicle gas leak detectors * Portable gas detectors Sensor element -3 Structure Figure shows the structure of TGS83. This sensor is a sintered bulk semiconductor composed mainly of tin dioxide (SnO2). The semiconductor material and electrodes are formed on an alumina ceramic tube. A heater coil, made of 60 micron diameter wire, is located inside the ceramic tube. Lead wires from the sensor electrodes are a gold alloy of 80 microns in diameter. Heater and lead wires are spotwelded to the sensor pins which have been arranged to fit a 7-pin miniature tube socket. The sensor base and cover are made of Nylon 66, conforming to UL 94HB (Authorized Material Standard). The deformation temperature for this material is in excess of 240 C. The upper and lower openings in the sensor case are covered with a flameproof double layer of 00 mesh stainless steel gauze (SUS36). Independent tests confirm that this mesh will prevent a spark produced inside the flameproof cover from igniting an explosive 2: mixture of hydrogen/oxygen. Fig. - Sensor structure Fig. 2 - Basic measuring circuit -4 Basic measuring circuit Figure 2 shows the basic measuring circuit for use with TGS83. Circuit voltage (Vc) is applied across the sensor element which has a resistance between the sensor s two electrodes and the load resistor (RL) connected in series. The sensor signal (VRL) is measured indirectly as a change in voltage across the RL. The Rs is obtained from the formula shown at the right. Rs = Vc - VRL VRL x RL Formula to determine Rs Revised 9/99 2

TECHNICAL INFORMATION FOR TGS83-5 Circuit & operating conditions -7 Dimensions The ratings shown below should be maintained at all times to insure stable sensor performance: Circuit Item voltage (Vc) Specification Max. 24V AC/DC Heater voltage (VH) 5.0V ± 0.2V AC/DC 7ø±0.5 Heater resistance (room temp.) 30 ± 3Ω 2 Load resistance (RL) Variable (min = [Vc / 60] kω) Sensor power dissipation (Ps) 5mW Operating & storage temperature -40 C ~ +70 C 6.5±0.5 Optimal detection concentration 500 ~ 0,000ppm 6.5 ±0.5-6 Specifications NOTE Item Specification S ensor resistance ( 000ppm methane) 5kΩ ~ 5kΩ 9.5ø Sensor resistance ratio (Rs/Ro) 0.60 ± 0.05 6 45 ø±0.05 Rs/Ro = Rs(3000ppm methane)/rs(000ppm methane) 5 2 Heater current (RH) approx. 67mA 4 3 45 Heater power consumption (PH) approx. 835mW Mechanical Strength: The sensor shall have no abnormal findings in its structure and shall satisfy the above electrical specifications after the following performance tests: Withdrawal Force - withstand force > 5kg in each direction Vibration - frequency-000c/min., total amplitude-4mm, duration-one hour, direction-vertical Shock - acceleration-00g, repeated 5 times Fig. 3 - Sensor dimensions NOTE : Sensitivity characteristics are obtained under the following standard test conditions: (Standard test conditions) Temperature and humidity: 20 ± 2 C, 65 ± 5% RH Circuit conditions: Vc = 0.0±0.V AC/DC VH = 5.0±0.05V AC/DC RL = 4.0kΩ ± % Preheating period: 7 days or more under standard circuit conditions Revised 9/99 3

TECHNICAL INFORMATION FOR TGS83 2. Basic Sensitivity Characteristics 0 2- Sensitivity to various gases Air Figure 4 shows the relative sensitivity of TGS83 to various gases. The Y-axis shows the ratio of the sensor resistance in various gases (Rs) to the sensor resistance in 000ppm of methane (Ro). Rs/Ro CO Using the basic measuring circuit illustrated in Figure 2, these sensitivity characteristics provide the sensor Methane Ethanol Propane Isobutane Hydrogen output voltage (VRL) change as shown in Figure 5. 0. 500 000 3000 5000 0000 Concentration (ppm) NOTE: All sensor characteristics in this technical brochure Fig. 4 - Sensitivity to various gases (Rs/Ro) represent typical sensor characteristics. Since the Rs 5 or output voltage curve varies from sensor to sensor, calibration is required for each sensor (for additional information on calibration, please refer to the Technical Advisory Technical Information on Usage of TGS Sensors for Toxic and Explosive Gas Leak Detectors ). VRL(V) 4 3 2 Hydrogen Methane Iso-butane Propane Ethanol CO Air Vc=5.0V RL=Rs in 000ppm methane 0 0 2000 4000 6000 8000 0000 2000 Concentration (ppm) Fig. 5 - Sensitivity to various gases (VRL) Revised 9/99 4

TECHNICAL INFORMATION FOR TGS83 2-2 Temperature and humidity dependency 2.0 Figure 6 shows the temperature and humidity dependency of TGS83. The Y-axis shows the ratio of sensor resistance in 000ppm of methane under various atmospheric conditions (Rs) to the sensor resistance in 000ppm of methane at 20 C/65%RH (Ro). Rs/Ro.5.0 0% R.H. 20% R.H. R.H. ( C) 0 %R.H. 20%R.H. 40%R.H. 65%R.H. 00%R.H. 0.9 0.8 40% R.H 65% R.H. 00% R.H. -0.860.742.676.609.556 0.792.523.44.353.303 0.733.346.247.50.02 20.684.2.095.000 0.955 0.7-0 0 0 20 30 40 50 Ambient Temperature ( C) Fig. 6 - Temperature and humidity dependency (Rs/Ro) 30.643.7 0.984 0.903 0.86 40.62.065 0.94 0.858 0.820 Table - Temperature and humidity dependency (typical values of Rs/Ro for Fig. 6) 0-0 C/0%RH 20 C/65%RH 40 C/00%RH Table shows a chart of values of the sensor s resistance ratio (Rs/Ro) under the same conditions as those used to generate Figure 6. Rs(kΩ) Figure 7 shows the sensitivity curve for TGS83 to methane under several ambient conditions. While temperature may have a large influence on absolute Rs values, this chart illustrates the fact that effect on the slope of sensor resistance ratio (Rs/Ro) is not significant. As a result, the effects of temperature on the sensor can easily be compensated. 0. 00 000 0000 00000 Concentration(ppm) Fig. 7 - Resistance change ratio under various ambient conditions For economical circuit design, a thermistor can be incorporated to compensate for temperature (for additional information on temperature compensation in circuit designs, please refer to the Technical Advisory Technical Information on Usage of TGS Sensors for Toxic and Explosive Gas Leak Detectors ). Revised 9/99 5

TECHNICAL INFORMATION FOR TGS83 2-3 Heater voltage dependency 0 Figure 8 shows the change in the sensor resistance ratio according to variations in the heater voltage (VH). Note that 5.0V as a heater voltage must be maintained Rs/Ro because variance in applied heater voltage will cause the sensor s characteristics to be changed from the typical characteristics shown in this brochure. Air CO Methane Isobutane Ethanol Hydrogen 0. 4.4 4.6 4.8 5.0 5.2 5.4 5.6 VH (V) Fig. 8 - Heater voltage dependency (Rs = Rs in 000ppm of specified gas, Ro = Rs at 000ppm methane and VH=5.0V) 00 2-4 Gas response Figure 9 shows the change pattern of sensor resistance (Rs) when the sensor is inserted into and later Rs (kω) 0 Gas: 000ppm methane removed from 000ppm of methane. Gas in Gas out As this chart displays, the sensor s response speed to the presence of gas is extremely quick, and when removed from gas, the sensor will recover back to its original value in a short period of time. 0 20 40 60 80 00 Time (sec) Fig. 9 - Response speed Figure 0 demonstrates the sensor s repeatability by showing multiple exposures to a 000ppm concentration of methane. The sensor shows good repeatability according to this data. 00 Rs (kω) 0 Gas exposure (000ppm methane) 0 5 0 5 20 25 Time (min) Fig. 0 - Repeatability Revised 9/99 6

TECHNICAL INFORMATION FOR TGS83 2-6 Initial action Figure shows the initial action of the sensor resistance (Rs) for a sensor which is stored unenergized in normal air for 30 days and later energized in clean air. The Rs drops sharply for the first seconds after energizing, regardless of the presence of gases, and then reaches a stable level according to the ambient atmosphere. Such behavior during the warm-up process is called Initial Action. Since this initial action may cause a detector to alarm unnecessarily during the initial moments after powering on, it is recommended that an initial delay circuit be incorporated into the detector s design (refer to Technical Advisory Technical Information on Usage of TGS Sensors for Toxic and Explosive Gas Leak Detectors ). This is especially recommended for intermittent-operating devices such as portable gas detectors. 000 00 Rs (kω) 0 0. -2 0 2 4 6 8 0 2 Time (min) Fig. - Initial action 2-7 Long-term characteristics Figure 3 shows long-term stability of TGS83 as measured for more than 8 years. The sensor is first energized in normal air. Measurement for confirming sensor characteristics is conducted under ambient air conditions rather than in a temperature/ humidity controlled environment. The cyclic change in sensitivity corresponds to the seasonal changes of temperature/humidity in Japan (peak T/H conditions occur in July, as corresponds with the sensitivity peaks in this chart). The Y-axis represents the ratio of sensor resistance in 000ppm of methane on the date tested (Rs) to sensor resistance in 000ppm of methane at the beginning of the test period (Ro). Rs/Ro 0 0. 0 400 800 200 600 2000 2400 2800 3200 Elapsed time (days) Fig. 2 - Long term stability (Ro = Rs on day ) As this chart illustrates, TGS83 shows stable characteristics over a very long period of time. Revised 9/99 7

TECHNICAL INFORMATION FOR TGS83 Figaro USA Inc. and the manufacturer, Figaro Engineering Inc. (together referred to as Figaro) reserve the right to make changes without notice to any products herein to improve reliability, functioning or design. Information contained in this document is believed to be reliable. However, Figaro does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights, nor the rights of others. Figaro's products are not authorized for use as critical components in life support applications wherein a failure or malfunction of the products may result in injury or threat to life. FIGARO GROUP HEAD OFFICE Figaro Engineering Inc. -5- Senba-nishi Mino, Osaka 562 JAPAN Tel.: (8) 727-28-256 Fax: (8) 727-28-0467 email: figaro@figaro.co.jp OVERSEAS Figaro USA Inc. 3703 West Lake Ave. Suite 203 Glenview, IL 60025 USA Tel.: () 847-832-70 Fax.: () 847-832-705 email: figarousa@figarosensor.com Revised 9/99 8