All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60 HEART ENTERPRISE CO. LTD. HEART ENTERPRISE CO., LTD. 0
Table of Contents Features 2 Specification 3 Wiring Description 4 Installation 5 1.Wiring Diagram of HA3021(Security controller included) 5 2.Wiring Diagram of HA3021 6 Main Function Description 7 1.Basic operation 7 2.Card Management 7 3.Duress Function 7 4.Guard Function 7 5.Modify Personal password 7 6.Back-up password 8 Parameter Listing 9 Parameter setting 10 Display / Error/ Warning message 11 Factory Default List 14 HEART ENTERPRISE CO., LTD. 1
FEATURES 1. Proximity type reader, read range up to 10cm (4 ). 2. Proximity card are less prone to physical damage or loss. 3. Memory capacity store up to 5000 card holders. 4. LCD display,16 characters 2 lines with back light 5. Three access mode options: (1). Mode 0: Card only (default). (2). Mode 1: Card and PIN.. (3). Mode 2: Card only or main password. 6. Anti-duress function : Card + personal password + random number or main password + random number With the anti-duress function provided, you no longer kidnap by thief. Key in a preset code to the rear, the duress relay will be activated to the require alarm device, other than the door opened normally. 7. Guard function : Guard password + Card The function can be used to arm/disarm the connected security system. 8. Personal Identification Number (PIN) Each card can be added with a four-digit PIN. This PIN is only valid when Mode 1: Card and PIN of the access modes are selected, which provides higher security. 9. Lock out on invalid password To prevent unauthorized persons from gaining password entry by trial and error, the system activates an alarm relay and/or automatically deletes the card number after five tries, once the option id selected in the system. 10. Keypad pause function Keypad key in incorrect five times and no distance of 1min, keypad function will stop 1min and display READY FOR CARD ENTRY HALT 11. User card can be register /delete in batch mode 12. Large 2-line LCD of 16 characters with back light feature including power saver function: the back light will turn off if inactive for more than 3 minutes.. 13. Alarm to be activated once incorrect password key-in five times within four minutes. 14. Last 100 Access Granted card numbers can be viewed on-screen. 15. Strike, alarm and duress relay have selectable activation timer (00-255 seconds) 16. Selectable door left open timer(0-255 seconds) 17. Audible key tone available 18. For safety reason the * will be displayed when entering card number or PIN 19. Force entry alarm function available. 20. Tamper alarm function available. 21. Three-piece enclosure design the reader is patted for weather and hazard proofing 22. A separate relay module design, high security provided 23. Check the record in any time. 24. Open door to key-in Card number. 25. Build-in RS485, copy data by this controller parameter and enrolled card. HEART ENTERPRISE CO., LTD. 2
SPECIFICATION Input Voltage : DC +10V to 15V DC Current : Average 135mA @12VDC; Peak 300mA @12VDC K1(Strike) & K2(Alarm) 0.4A @125VAC / 2A @30VDC Contact Current : K3(Bell) & K4(Guard) 0.1A @100VAC / 0.5A @20VDC Frequency (optional) : 125KHz 134.2KHz or 13.56MHz Read Range : 1. 125KHz & 134.2KHz:Up to 7 cm (In noise-free environment) 2. 13.56MHz:Up to 5 cm (In noise-free environment) *1 Keypad : 12 keys (0 ~ 9,*,#) Display : 16 characters, 2 lines, LCD with backlight. LED Indicator : Bicolor (Greed/Red) Memory Capacity : 5000 cards (Including PIN) & last 100 transactions Weight : 380g MAX Operating humidity : 5%~95% (relative humidity, non-condensing) Operating temperature : 0 ~70 / 32 ~158 Card type (optional) : EM HID Mifare(ISO14443A) TI-LF(134.2KHz) or TI-HF(ISO15693) Case material : ABS (UL94V0) Dimensions : 150 x 110 x 45 mm / 5.9 x 4.3 x 1.8 in. Remark: *1. Reduced read range with keytag and proximity sticker. WIRING DESCRIPTION Pin Wire Colore Function Description 1 Red V+ + 8.5V to 16V DC 2 Black GND Power Ground 3 Blown EXIT Exit Button 4 Orange STATUS Door Status Sensor 5 Yellow COM1 Strike Relay COM 6 Green NC/NO1 Strike Relay NC/NO 7 Blue COMS Alarm Relay COM 8 Purple NC/NO2 Alarm Relay NC/NO Strike Relay Contact Selection Alarm Relay Contact selection HEART ENTERPRISE CO., LTD. 3
9 Grey COM3 Door Bell Relay COM 10 White NO3 Door Bell Relay NO 11 Light Blue COM4 Guard Relay COM 12 Light Green NO4 Guard Relay NO 13 Deep Pink Guard+ Guard Status Sensor(+) 14 Light Pink Guard- Guard Status Sensor(-) HEART ENTERPRISE CO., LTD. 4
INSTALLATION 1. Wiring diagram of HA3021(Security controller included). HEART ENTERPRISE CO., LTD. 5
2.HA3021 Wiring Diagram HEART ENTERPRISE CO., LTD. 6
MAIN FUNCTION DESCRIPTION 1. Basic operation MODE 0 Card only DEFAULT: This mode only requires the user to present his card to be granted access. MODE 1 Card and PIN: The mode requires that the user presents his card and then enters his PIN on the keypad. This mode is suitable for application s where higher security is needed. MODE 2 Card only or main password only: This mode will require that the user presents his card to the reader or enter main password using the keypad to be granted access. Open the door by exit button: Opening the door just pressed the exit button. 2. Card Management Up to 5,000 user cards can be registered in the HA3021 system. All cards are required to be registered in the system before use. Depending on how many cars you need to program, you can simply add them one at a time or use the batch process to ass a per-selected batch of cards in the system. For more information on cards, refer to the Adding & Deleting Cards section. 3. Duress Function: The duress function is used to provide added security to personnel. In situations of duress, a cardholder presents his card to the reader, and then enters his PIN + any one-digit number (0-9) when the MODE1 of the access modes is selected. Or enter the master password + any one-digit number (0-9) when the MODE 2 of the access modes is selected. Access Mode Duress operation procedures 1 MODE 0 Card only Not available 2 MODE 1 Card and PIN Card + PIN + (any one-digit number)+# 3 MODE 2 Card only or main password only Enter master password + (any one-digit number) +# 4. Guard Function: (Guard password + # + Card) HA3021 equipped a guard relay which can arm or disarm the connected security system. Use guard password or guard pass word plus card data to activate this function. HEART ENTERPRISE CO., LTD. 7
5. Modify Personal password: 1. MODE 1, display after sensor card Enter Password Code NO.: 2. And now enter * + old personal password (default: 0000) New Password Code NO.: 3. Enter new password(4 digit) and enter #. 6. Back- up password: Back up password: 23400204 Key-in back up password and enter # when forgot the password, and then sensor the valid card, you will enter the setting mode. And setting password recover 111111(factory default), controller have to at least enroll one valid card. Operation: Key-in back-up password (23400204) + # + Valid Card. HEART ENTERPRISE CO., LTD. 8
PARAMETER LISTING The hierarchy diagram shows the relationship of each function Main function Function 1 Function 2 Function 3 Function 4 Function 5 Function 6 1.ENROL 2.PASSWD 3.TIMER 1.S-ADD 2.S-DEL 3.B-ADD 4.B-DEL 1.MASTER 2.MAIN 3.REVIVE 4.GUARD 1.STRIKE 2.ALARM 3.DB 4.GUARD 1.ALARM 1.FORCE 2.TAMPER 3.P-ERR 4.SYSTEM 2.KNOCK 3.GUARD 4.OTHER 4.DURESS 1FUNCTION 2.GUARD CIRCUIT 1.ReALARM 2.CARD 3.RECORD 4.MORE 1.REVIVE 2.TONE 3.ACCMOD 4.MORE 1.DOOR 2.ERASE 3.CLOCK 4.MORE 1.MEMORY ERASE 2.RECORD ERASE 1.Databass Copy 2.Hardware Test 1.PARAMTER 2.ENROLLED CARD HEART ENTERPRISE CO., LTD. 9
PARAMETER SETTING 1. Enrollment Entry the parameter setting, press # for three seconds and when monitor change enter 1, then enter the default master code "111111" (factory default). 1.1 Add a new card(s_add) : 1 1 Card or password # 1.2 Delete a card(s_del) : 1 2 Card or password # 1.3 Add the cards in batch mode(b_add) : 1 3- Card serial no.1 enroll card quantity you want (1~5000). # 1.4 Delete the cards in batch mode(b_del) : 1 4 Card serial no.1 delete quantity of card (1~5000). # 1.5 Modify setting password(master) : 2 1 random 6 digit number # 1.6 Modify main password(main) : 1 1 random 4 digit number # 1.7 Modify relieve arm password(revive) : 2 3 random 7digit number # 1.8 Modify guard password(guard) : 2-4 random 3 digit # 1.9 Modify strike active time (STRIKE) : 3 1 0~255 sec.(0 sec. is LATCH mode) # 1.10 Modify alarm active time(alarm) : 3 2 0~255 sec. (0 sec. is last alarm) # 1.11 Modify an interval time of door left open(db) : 3 3 0~255 sec. (0 sec. ***) #- 1.12 Modify security relay motion time(guard) : 3 4 0~255 sec. (0 sec. is LATCH mode) 1.13 Force entry setting enable/disable(force) : 4 1 1 1(DISABLE-ENABLE) # 1.14 Tamper alarm setting(tamper) : 4 1 2 1(DISABLE- ENABLE) # 1.15 Alarm activated when enter incorrect password five times(p_err) : 4 1 3 1(DISABLE-ENABLE) # 1.16 Anti-duress alarm(duress) : 4-1-4-1(DISABLE-ENABLE) # 1.17 Door bell function(knock) : 4 2 1(DISABLE- ENABLE) # 1.18 Guard setting function(guard FUNCTION) : 4 3 1 1(DISABLE-ENABLE) # 1.19 Guard circuit status detection(guard CIRCUIT) : 4 3 2 1(DISABLE-ENABLE) # 1.20 Delay re-alarm function(realarm) : 4 4 1 1(DISABLE-ENABLE) # 1.21 Key in no. to open (CARD) : 4 4 2 1(DISABLE-ENABLE) # 1.22 Entry record setting(record) : 4 4 3 1(DISABLE-ENABLE) # 1.23 Relive alarm password setting(revive) : 4 4 4 1 1 (DISABLE-ENABLE) # 1.24 Button tone (TONE) : 4 4 4 2 1(DISABLE-ENABLE) # 1.25 Selection of open mode (ACCMOD) : 4 4 4 3 1(MODE2 MODE 0 MODE 1 # 1.26 Door sensor status (DOOR) : 4 4 4 4 1 1(NO-NC) # 1.27 Clear all enroll card data and record(memory ERASE) : 4 4 4 4 2 1 1 6 digit setting password # 1.28 Clear card record(recode ERASE) : 4-4 4 4 2 2 1 6 digit password # 1.29 Date/Time Adjustment (CLOCK) : 4 4 4 4 3 by sequence keypad button 1 (decrease) keypad button 3 (increase) # confirm to adjust mth/date/hour/min # 1.30 Controller parameter copy(paramter) : 4 4 4 4 4 1 1 1.31 Card data copy (PARAMTER) : 4 4 4 4 4 2 1 HEART ENTERPRISE CO., LTD. 10
Display / Error / Warning message WELCOME Access Granted Message displays when entitle to enter. WARNING Invalid Card Message displays when using invalid card. Please enroll the card to become valid card before use. WARNING Invalid Entry 1. Under Mode 0, it s only for card holder access granted so by key in password to enter, error message shows. 2. Wrong password please re-enter the correct password. READY FOR CARD DOOR OPEN 1. Once door open without closing, alarm will be activate and message will display on screen. Please close the door to stop alarm. 2. Forced entry will activate the alarm sound to warn security guard if any intruder. READY FOR CARD RELEASE ALARM Message displays when release alarm code was enter to disarm. HEART ENTERPRISE CO., LTD. 11
+ + + In Guard + + + Message displays when under In Guard mode. READY FOR CARD DOOR BELL ON Message displays when door bell button is being push. READY FOR CARD FORCE ACCESS Message displays when enter the door by forcing it to open and alarm continuously beeping. By using valid card or key in disarm code can release the alarm. READY FOR CARD TAMPER ALARM Message displays when casing was dismantled and alarm sound continuously. By using valid card or key in disarm code or mount back the casing can release the alarm. READY FOR CARD ENTRY HALT Message displays when entering wrong pass words for 5 times, keypad will halt for 1 minute. By using valid card or wait for 1 min. to continue the process. CARD PLEASE Message displays when reading is in process. HEART ENTERPRISE CO., LTD. 12
Data Transfer Message displays when data transfer is in process. Data Receive Message displays when data receiving is in process. PARAMETER Transfer Fail! Message displays when controller parameter transfer fails, please check RS485 cable. Data Transfer Transfer Fail! Message displays when data transfer fails, please check RS485 cable.. HEART ENTERPRISE CO., LTD. 13
FACTORY DEFAULT LIST Description Factory Default Access mode Mode 2 (Card data or password) Master code 111111 Main password 1234 Revive Password 1234567 Guard Password 123 Personal Password 0000,refer to page 3 Strike Relay Active Time 5 sec.(0~255s, 0 is flash mode) Alarm Relay Active Time 10 sec.(0~255s, 0 is last alarm) Guard Relay Active Time 1 sec.(0~255s, 0 is LATCH mode) Alarm relay activated of door left open 0 sec.(0~255s, 0 is dis-alarm) Anti-duress alarm Active Time Same as Strike Relay Tamper Alarm Force Entry / Exit alarm Alarm Guard Function Setting Guard Circle Detection Relay Alarm Press Card number to open the door Card Record Save Function Release Alarm Password Button Tone Enable Door Sensor Status N/O Date / Time Display HEART ENTERPRISE CO., LTD. 14