Product Specifications 480 VAC, 175A Main Power Distribution Panel

Similar documents
Product Specifications 480 VAC, 70A Main Power Distribution Panel

Product Specifications Auto Restart Main Power Distribution Panel

Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications Linear Accelerator Relay Junction Box

Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications Fail Safe Emergency Power Off Control Panel 480V 3 Phase

Product Specifications Warning Light Control Cabinet

Product Specifications Warning Light Control Cabinet

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Electric Duct Heaters

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

MaxLite Polygon Linear LED Light

Elevator Control ES Switch

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

PART GENERAL 1.01 SECTION INCLUDES

Installation, Operation & Service Manual

MaxLite LED High Bay Fixtures

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

Quest Power Electric Heat EHS 62 Pro

INSTALLATION and OPERATION INSTRUCTIONS

Installation Manual. Models 99168, 99169, 99170

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

Installation & Operation Manual for WarmlyYours Towel Warmers

SIMPLEX WEATHERPROOF CONTROL PANELS

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

SC-6 Six Supervised Control Module

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

InstructIon Manual KrEs EQuIPMEnt stands

Installation & Operation Manual for WarmlyYours Towel Warmers

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

Installation Instructions

Service Parts, Kits and Accessories

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

GETZ MANUFACTURING PART # CYLINDER DRYER

Desiccant / Pump Dehumidification System. Model Operating Manual

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Hardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers

CABINET INFRARED HEATER

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

D E S I G N G U I D E REVISED 10 / 2017

Owner s Manual Hydro-X Vacuum Pac

D E S I G N G U I D E REVISED 9 / 2018

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

SECTION AUTOMATIC TRANSFER SWITCHES

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Drawing Submittal Package

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Instruction Manual and Warranty

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

DISPOSER CONTROL CENTER

VENTILATION FAN WITH LIGHT AND HEATER

OPERATION, SERVICE & PARTS MANUAL

Drawing Submittal Package

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

For use with models: BP , BP , BP

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Guide Specification Model CTG Automatic Transfer Switch

Owner s Manual Phoenix Aquadry TX 200

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Phoenix AirMAX - Radial Air Mover

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

GENESIS Indoor Air Conditioners

ELECTRIC FLAT PANEL FIREPLACE HEATER

ASCO Series 185 Power Transfer Switches

ASME Packaged Electric Water Heater

Inline Heater for Solvent or Gas. Installation and Operation Manual

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

OPERATING INSTRUCTIONS

Best Practices for Specifying Emergency Power Systems

User Manual. Conveyor Toaster. Models: T140 06/2017. Please read and keep these instructions. Indoor use only.

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

HTLS. Heat Tracing Line Sensing Control Panel

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

Transcription:

NOVA Energy & Automation Product Specifications 480 VAC, 175A Main Power Distribution Panel Model NEAS-43175-ST 29 July 2012

Product Description 1. Standard Applications The Nova NEAS-43175-ST system Main Disconnect Panel (MDP) serves as the main facility power disconnect source installed ahead of the medical imaging equipment. Each MDP is sold with 2 remote Emergency stop Buttons. The MDP saves time, installation labor, and valuable mounting space by consolidating the main circuit breaker and the feeder over current devises into one integrated panel. The panel design includes short circuit, overload and emergency shutdown of the system. All power is controlled by an ADA approved through the door disconnect or by the remote emergency operator control station. 2. System Compatibility The Nova NEAS-43175-ST is compatible with the following medical imaging equipment: Philips Healthcare: MR 3. Identification Philips Healthcare MR: The proper distribution panel can be identified in the Philips site planning drawings sheet EL Electrical Legend item CB Equal to item 175A 480VAC Circuit Breaker with shunt trip and related components Figure 1 Nova 175A Main Disconnect Panel Co Author: JF 2

4. Features/ Benefits Features Benefits UL and cul listed to conform to NEC Labeled to conform with NFPA99, NFPA-70, NEC 100, NEC 110-3, NEC 660.5 Provides over current and short circuit protections Short circuit current rated at 22kAIC Single point main disconnect and termination point American Disabilities Act (ADA) approved through the door disconnect handle provides one hand ON/OFF operation. The ADA handle makes turning the imaging equipment on and off during emergencies or power failures easy for technicians and nursing staff. Lock Out/ Tag Out lockable operating handle provides added safety during maintenance and OSHA requirements. Interlocked ON/OFF hinged door prevents access to the panel while the disconnect is in the ON position. Door may be locked closed with customer provided padlock. ¼ turn slotted door latch provides additional security. Isolated Neutral lugs Oversized ground lugs for parity sizing of ground wire Compact size for easy installation Thermal Overload protection is provided by heat sensitive bimetals. Short Circuit protection is accomplished using a precise magnetic coil. Factory wired to match medical imaging equipment and tested Manufactured in the USA Designed, tested, and installed on several projects worldwide Manufactured using the highest quality components for high reliability and long life Provides protection for sensitive electronic equipment Manufactured to a tolerance which exceeds the specifications of the medical imaging equipment. Easy to view LED indicator lights for System ON Reduced weight- all components are within a small 45lb enclosure Reduces installation time and cost by eliminating delays in obtaining individually enclosed components and by eliminating on site assembly Provides a standardized platform for other future modifications or upgrades Co Author: JF 3

5. Specifications Model Application Input Voltage Output Voltage Control Voltage Emergency Power Off Controls Operator Controls Compatible Estop Buttons Overload Current Protection Short Circuit Current Protection Instantaneous Trip Settings Approvals NEAS-43175-ST 175 Amp Main Disconnect with Shunt Trip and Internal Controls 480VAC (please specify if other voltage is required) 480VAC (please specify if other voltage is required) Internally derived 24VAC for controls 24 VAC Shunt Trip Compatible with 24 VAC and Low Voltage EPO operator devices Normally Open Contacts Philips MR: 2 Estops- 2 NO Contacts Factory set to 175A, (please specify if other current rating is required) 22 KAIC Field adjustable UL/cUL 6. Weights and Dimensions Mounting Dimensions Weight Mounting Enclosure Enclosure Sealing Main disconnect is provided in a steel enclosure suitable for surface or semi flush installations. Height: 19.68 (500mm) Width:15.77 (400mm) Depth: 5.9 (150mm) 39 lbs. (17.69 kg) Rear wall mounting holes (4). Spaced 0.79 (20mm) from enclosure edge. Optional mounting brackets are available 16 Gauge Carbon Steel, all rounded corners 1 gland plate in the enclosure base. Foamed-in place polyurethane door gasket Finish Dip coat primed, powder coated in textured RAL 7035 Latching Mechanism Interior Panel Protection Category Two ¼ turn latches with double-bit inserts (cam lock). Door is hinged on the left side but can be swapped if specified when order is placed. Zinc-Plated subpanel IP 66 to EN60 529/09:2000, complies with NEMA 4 Enclosure Approvals: UL, CSA, TUV, GL, Lloyds, VDE, Bureau Veritas Co Author: JF 4

Top View 15.75" (400mm) 5.94" (150mm) Power On 19.68" (500) CG CG 9.84" (250) 76.2 (3") 7.87" (200) Right Side View Figure 2 Enclosure Dimensions: Outside, Mounting, Depth Figure 3 Enclosure Mounting Holes on back Co Author: JF 5

7. Warranty This limited warranty set forth below is given by Nova Automation ( Seller ) with respect to the electrical equipment ( Product ) packaged with this limited warranty. The Product, when delivered to you in new condition in its original packaging, is warranted against defects in materials or workmanship as follows: For a period of one (1) year from the date of original purchase, defective parts or a defective Product returned to a Seller, or its authorized service providers, as applicable, and proven to be defective upon inspection, will be repaired, or exchanged for a new Product, as determined by the Seller, or the authorized service provider. This limited warranty covers all defects encountered in normal use of the Product, and does not apply in the following cases: Loss of or damage to the Product due to abuse, mishandling, alteration, accident, electrical current fluctuations, failure to follow operating, maintenance or environmental instructions prescribed by Seller, failure to follow Sellers installation instructions, or service performed by someone other than Seller or its authorized service provider. Nova assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any consequential or incidental damages arising from the use of the product. Nova Automations entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement of the product. WARRANTY IS VOID IF PRODUCT IS NOT USED FOR THE PURPOSE FOR WHICH IT WAS MANUFACTURED. 8. Product Service and Technical Assistance Nova Automation, LLC 2722 N. Avondale Blvd Milwaukee WI 53210 PH# 262-309-2950 Website: www.novaautomation.net Co Author: JF 6

9. Approvals Prepared By ([Job Title]) This document requires the following approvals Approved By ([Job Title]) ([Job Title]) Approval Date Co Author: JF 7