QUICK SET UP GUIDE LU-8047-QS. QUV Accelerated Weathering Tester. Condensation Tester

Similar documents
QUICK SET-UP GUIDE LX-5085-QS. Xe-2 Xenon Test Chamber

Q-FOG Cyclic Corrosion Testers. A More Realistic Salt Spray

Cyclic Corrosion Testers

Cyclic Corrosion Testers

Cool IR. Model C104 - Cooling System. Instruction Manual

INSTALLATION INSTRUCTIONS

HHP-300 EXTRACTOR 120V

Manual / Handbuch Spare parts list / Ersatzteilliste

Viking Installation Guide

Site Specifications for the. INDUSTREX M37 Plus NDT Filmprocessor

MODEL SW-2. Sample specifications for SW-2 SPECIFICATIONS

PROBLEM CAUSE CORRECTIVE ACTION. Product Service Replace cup. Malfunction of cup. Detergent cup fails to open. Malfunction of relay

INSTALLATION INSTRUCTIONS

ADVANTAGE-100H-SC EXTRACTOR

MV 2. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

COBRA -H EXTRACTOR 120V

Viking Installation Guide

Dishwasher. Installation manual DW60M9990AP

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

VIKING RANGE CORPORATION, P.0. DRAWER 956, GREENWOOD, MS. USA

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

MV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Condensate Pump. Installation and Safety Instructions CP-NL20 CP-NL20-230

SPOTTER CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

AVANI Grinding Booth

Incutrol/2 Regulator

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

DEVIL CERAMIC SPACE HEATERS

INSTALLATION INSTRUCTIONS

Rota- Station and Plus Instructions

P/N CC-100. Coolant Circulator. Operation manual

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

LC Series - Light Commercial Pump Station Installation and Operation Manual

Aloha Vertical Victory Garden

installation Guide

PZ1, PZ3 & PZ6 Installation Guide

Rota- Station and Plus Instructions (Mega Part & )

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

Removing shipping locks

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Condensate Pump. Installation and Safety Instructions CP-16 CP

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

HDLV 55-Gallon Powder Drum Unloader

Next Generation Corona Discharge Installation & Operation Manual

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

SECTION PLUMBING EQUIPMENT

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

WATT R TWIN Energy-Efficient Home Water System

COBRA -300H EXTRACTOR

1-866-PENNERS

HWD-2110 Hot Water Dispenser

Work-Shed Vac 1100 Watt

HR Powder Feed Hopper

Refresh & Clean Carpet Washer

Hot-1 Hot Water Dispenser

SELF-CONTAINED FLAKER

Installation Instructions

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

Installation Manual for M-G014 & M-G015

Machine Tool Coolant Units

Ozone Generator Systems

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

Installation Instructions 36 Inch Refrigerator

OptiSoft Softeners Simple Install Steps 1-17

Operator s Manual. The Quietek

Controlled Environment Equipment Solutions for the Lab

SECTION PLUMBING EQUIPMENT

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

tungsten Smart-heat electric heater

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

High Output Vacuum/Pressure Pump

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

GEMINI TM DYNACONTROL TM HOSES Automatic & Manual Versions FOR DYNAMELT & DYNAMINI TM ADHESIVE APPLICATION SYSTEMS

BASIL 6000 TUNNEL CAGE WASHER

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

HP310-C EXTRACTOR 120V

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

Ozone Generator Systems

XM Plural-Component Sprayers High-Pressure Equipment for Protective Coatings

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

XLT-60 EXTRACTOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

NHR-25 Feed Hopper with Agitator

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

TCUT10UL 2.5 HP 10 Tile Saw Assembly & Operating Instructions

PWC-500/1000/1010/1500

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Transcription:

QUICK SET UP GUIDE LU-8047-QS QUV Accelerated Weathering Tester Condensation Tester Revision Date 16 Jul 2018

Table Of Contents Section Page 1. Purpose...2 2. Unpacking...3 3. Placement...5 4. Dimensions...6 5. Environment...6 6. Electrical...7 7. Water Supply...8 8. Water Drain...10 1. Purpose This Quick Set-up Guide is not an Operating Manual. It is intended to explain only the basics of setting up a QUV accelerated weathering tester and a QCT condensation tester. The QUV Technical Manual LU-8047-TM is necessary for a complete understanding of how to operate the QUV weathering tester. The QCT Technical Manual LC-0875 is necessary for a complete understanding of how to operate the QCT condensation tester. 2

Section 2: Unpacking 2. Unpacking 1. Cut the plastic straps that hold the fiberboard carton to the skid. 2. Remove the carton. Cut Carton Cut Remove Skid 3. Remove the bubble wrap and film from the tester. Remove QUV Tester Shown 4. Cut the plastic strips holding the tester to the skid. Cut Cut 3

Section 2: Unpacking 5. Remove accessory items including box containing casters from the tester rear enclosure. Remove 6. Use 2 persons to rotate the tester diagonally on skid. Top View Tester Skid QUV Weight: 136 kg (300 lbs) QCT Weight: 80 kg (176 lbs) 7. Remove 4 casters from box. 8. Push the casters into the sockets in the tester legs. NOTE: Casters are the primary means of transportation. Caster 4

Section 3: Placement 9. Use 2 persons to carefully remove the tester from skid. QUV Weight: 136 kg (300 lbs) QCT Weight: 80 kg (176 lbs) 3. Placement The tester should be positioned as shown in the figure below. This will allow sufficient room to operate the unit, gain access to service areas and allow proper ventilation. Wall 24" (60cm) Minimum TESTER TESTER 24" (60cm) Minimum TESTER TESTER 6" (15cm) Minimum 12" (30cm) Recommended 6" (15cm) Minimum 12" (30cm) Recommended 5

Section 4: Dimensions 4. Dimensions External Dimensions A C B D QUV QCT A 137cm 54.0" 137cm 54.0" B 131cm 51.5" 131cm 51.5" C 52cm 20.5" 52cm 20.5" D 135cm 53.0" 102cm 40.25" 5. Environment Suitable Environments Operating the tester in an unsuitable environment will void the warranty. These are sophisticated scientific instruments. They must be operated in a controlled environment. The QUV and QCT testers are intended for indoor use only. The testers are not protected against harmful ingress of moisture or water. Room Temperature: 70 o F (21 o C) and 80 o F (27 o C). Room Humidity: Non-Condensing. Ventilation: The QUV tester adds 700 watts (2400 BTU/hr) and 8 liters of water per day to room air. Locate away from drafts. Pollution Control: Rated as Pollution Degree 2. Sound Pressure Level: < 74dBA. Altitude: Up to 2000 meters. 6

Section 6: Electrical Unsuitable Environments: Examples of unsuitable environments that will void your warranty. Outdoors: Rain and dust will corrode or short out electrical components. Metal Dust / Metal Chips: Do not locate the tester near metal cutting machines or metal grinding machines. Conductive metal dust or metal chips in the air will damage electronic components. Carbon Fibers: Do not operate the tester where carbon fibers or carbon reinforced plastic are being cut. The conductive carbon fibers will damage electronic components. Conductive Pigments: Do not operate the tester where carbon black or other conductive pigment dust is in the air. The conductive dust will damage electronic components. Salt Fog: Do not operate the tester next to a Salt Spray Chamber. Salt fog drawn into the tester s electronics with cooling air will cause corrosion and short circuits. Other Corrosive Gases: Do not expose the tester to acid fog, SO2 gas or other corrosive gases. Excessive Voltage: The electrical supply to the tester must be no more than 10% higher than the voltage listed on the nameplate. Low Voltage: Recurring brown-outs or voltages less than 90% of the rated voltage will damage electrical components. Water Leaks from Ceiling: Water leaking onto the tester will damage electrical components. 6. Electrical Voltage: Shown on the nameplate, either 120 or 230 +/- 10%. Current: 120V QUV/se and QUV/spray: 16 amps 120V QCT: 15 amps 120V QUV/basic: 14 amps 230V QCT: 7 amps 230V QUV/se and QUV/spray: 230V QUV/basic: Frequency: 50 or 60 hz. 8 amps 7 amps Circuit Protection: Built in breaker, 20A for 120 volt machines and 10A for 230 volt machines. Electrical Connection: A 3-prong grounding plug is provided for 120V testers. 120V 230V Power: Black Brown Neutral: White Blue Safety Earth Ground: Green Green/Yellow Although a Main Power Switch is provided at the rear of the unit, the specified means for disconnecting the AC Main supply circuit is the plug on the power supply cord. If the plug is not easily accessible for this purpose, then an external Disconnect Switch must be provided in the installation. Transient Over voltage: Installation Category II of transient over voltages. 7

Section 7: Water Supply 7. Water Supply QUV/basic, QUV/se, QUV/cw, QCT Purity: Ordinary tap water. Pressure: 2 psi (13.8 kpa) to 80 psi (550 kpa). Volume: 8 liters per day. Connections 1. Install the saddle valve and connect tubing as shown below. For QUV/spray models, see the connection information on Page 9. Saddle Valve 6 mm (1/4") Plastic Tube (Preferred) Brass Insert Plastic Sleeve 6 mm (1/4") Copper Tube (Alternate) Brass Ferule Rubber Washer Water Supply Pipe 2. Connect saddle valve to the QUV water feed valve with 1/4" tubing (included in CV-255-K) or 6 mm tubing (included in CV-60131-K). Water Feed Assembly Tubing 3. See LU-8047-TM QUV Technical Manual for additional connection information. 8

Section 7: Water Supply QUV/spray, QUV/spray/rp Purity: Purified water is required for proper operation. Resistivity > 200 kohms-cm, PH 6.0 to 8.0. Pressure: 40 psi (225 kpa) to 80 psi (550 kpa). Spray Volume: 7 liters per minute (LPM). See LU-8047-TM QUV Technical Manual for detailed purity requirements for QUV spray models. Connections The QUV/spray water supply connects to the solenoid valve assembly at the left rear of the tester. Three (3) options are available to connect the water supply to the QUV/spray (see below). 1. Connect a 1/2 inch supply hose over the supplied hose barb and secure it with a hose clamp. 2. Connect a 1/2 inch supply tube into the push lock elbow. 3. Connect a 12 mm supply tube using the supplied tube adapter (Part # U-40816-X, 230 V testers only). Connections between QUV/spray and the water supply should be stainless steel or plastic. Elbow Swivels Solenoid Valve Assembly Connection Location Hose Barb for 1/2 Inch Hose Push Lock Elbow for 1/2 Inch Tubing Adaptor for 12 mm Tubing 9

Section 8: Water Drain 8. Water Drain Water Pan Cleaning Drain: Turn off water supply and unclamp to empty the water pan. Water Feed Overflow Drain: The 1/2" (12mm) hose supplied with the tester should be connected to the water feed overflow port and run to a floor drain. Water Pan Drain (QUV/spray only): 1-1/4" (32mm) drain hose is supplied. Connect to the fitting under the water pan and secure with a hose clamp. Run to a floor drain. Water Pan Drain QUV/spray Only Water Feed Overflow Drain Water Pan Cleaning Drain 10

Please contact the nearest international branch office by phone or email for technical support. Repair and Tester Support is available over the telephone Monday through Friday from 8:30 AM to 5 PM. You can also visit our website at www.q-lab.com to register your tester to access additional useful troubleshooting guides, operating manuals, and technical information. Q-Lab Headquarters Westlake, OH USA Tel: +1-440-835-8700 Repair@q-lab.com Q-Lab Europe, Ltd. Bolton, England Tel: +44-1204-861616 RepairEurope@q-lab.com Q-Lab Deutschland GmbH Saarbrücken, Germany Tel: +49-681-857470 RepairGermany@q-lab.com Q-Lab China 中国代表处 Shanghai, China 中国上海电话 : +86-21-5879-7970 RepairChina@q-lab.com Q-Lab Corporation www.q-lab.com Q-Lab Headquarters Westlake, OH USA Tel: +1-440-835-8700 info@q-lab.com Q-Lab Europe, Ltd. Bolton, England Tel: +44-1204-861616 info.eu@q-lab.com Q-Lab Deutschland, GmbH Saarbrücken, Germany Tel: +49-681-857470 vertrieb@q-lab.com Q-Lab Florida Homestead, FL USA Tel: +1-305-245-5600 q-lab@q-lab.com Q-Lab Arizona Buckeye, AZ USA Tel: +1-623-386-5140 q-lab@q-lab.com Q-Lab China 中国代表处 Shanghai, China 中国上海电话 : +86-21-5879-7970 info.cn@q-lab.com LU-8047-QS 2013 Q-Lab Corporation. All Rights Reserved. Q-Lab, the Q-Lab logo and QUV are registered trademarks of Q-Lab Corporation. 11