Notice to all Recognised Organisations, Shipowners, Masters, and Shipbuilders

Similar documents
MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

Resolution A.1116(30) Adopted on 5 December 2017 ESCAPE ROUTE SIGNS AND EQUIPMENT LOCATION MARKINGS

TECHNICAL ALERT No

Requirements for ships carrying hydrogen and compressed natural gas vehicles

Photoluminescent maritime safety signs

ISO INTERNATIONAL STANDARD

HI-FOG for Ro-Ro and Special Category spaces

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

Technical Information

COMDTPUB P NVIC Mar NAVIGATION AND VESSEL INSPECTION CIRCULAR NO Electronic Version for Distribution Via the World Wide Web

MSC Guidelines for General Emergency Alarm & Public Address Systems

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

ISO INTERNATIONAL STANDARD. Ships and marine technology Lowlocation lighting on passenger ships Arrangement

IMO DEVELOPMENT OF MODEL PROCEDURE FOR EXECUTING SHIPBOARD EMERGENCY MEASURES. Fire-fighting drills. Submitted by the Republic of Korea

INFORMATION BULLETIN No. 150

Parish of Repton NEIGHBOURHOOD DEVELOPMENT PLAN

COMMISSION REGULATION (EU)

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

Unit and Assessment Specification

FIRE SAFETY ON BOATS. In partnership with

MAIB SAFETY BULLETIN 2/2010. Failure of fixed high expansion foam system to extinguish fire on board the passenger ferry Oscar Wilde

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE

Fire Safety Policy Date: 0

26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

COMMISSION REGULATION (EU)

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

Low Location Lighting

Burnham-on-Sea & Highbridge Town Council. Burnham Joint Burial Committee (BJBC) Closed Circuit Television (CCTV) Policy

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

Attachment 1. to ClassNK Technical Information No. TEC-1077 Isle of Man Ship Registry Manx Shipping Notice SOLAS II-2 The Maintenance and inspection o

Fire and Rescue Services Act 2004 Factsheet

Interferry Ro Ro Deck Fire Safety Operational Best Practice Guidance

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

OFFSHORE SUPPORT VESSELS 2014

Can we use knowledge and experience from other sectors to prove Water mist s suitability for land applications? UK Water Mist Seminar 8th March 2016

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

FIRE & RESCUE MARINE RESPONSE

The Dell Out of School Club

GUARDIAN - SPECIALIST ESCAPE LOCKS

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

ISO INTERNATIONAL STANDARD. Ships and marine technology Lowlocation lighting (LLL) on passenger ships Arrangement

Fire prevention and protection

Panic and Emergency Exit Devices

Perth and Kinross Council Development Management Committee 24 April 2013 Report of Handling by Development Quality Manager

Dispute over the requirement for fire door signage to hotel suites at 124 Devon Street West, New Plymouth

ClassNK Technical Information No. TEC-0838 (iii) The dormant period, visual indication, first stage audible alarm, second stage remote audible alarm a

Amendments to the Revised Guidelines for the Maintenance and Inspection of Fire Protection Systems and Appliances (MSC.1/Circ.

ST. VINCENT AND THE GRENADINES

RESOLUTION MSC.101(73) (adopted on 5 December 2000) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES

Fire prevention and protection

Introduction to SRtP. Mr Georgios Vavourakis

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

FIRA Technical Services. Suzie Radcliffe-Hart Technical Manager

IMO LIST OF DOCUMENTS ISSUED IN CONNECTION WITH THE FORTY-SEVENTH SESSION OF THE SUB-COMMITTEE ON FIRE PROTECTION AGENDA FOR THE FORTY-SEVENTH SESSION

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

IMAS nd Edition Director, United Nations Mine Action Service (UNMAS), DC2 0650, United Nations, New York, NY 10017, USA

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2)

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

Prescription of qualifications. ARB Criteria at Part 2

BWTS installation and beyond UK Chamber of Shipping BWM implementation forum

Policy for Safe Evacuation of Persons with Disabilities

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

IMO FP 54 Agenda Preview (Updated version)

A guide to landlords duties: Gas Safety (Installation and Use) Regulations What type of property is covered?

IMO CCC1 Summary Report on the developments of the IGF Code

RESOLUTION A.752(18) adopted on 4 November 1993 GUIDELINES FOR THE EVALUATION, TESTING AND APPLICATION OF LOW-LOCATION LIGHTING ON PASSENGER SHIPS

Peninsula Dental Social Enterprise (PDSE)

Fire Risk Assessment

ABLOY safety and security solutions for TRANSPORTATION AND LOGISTICS

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Fixed Fire Extinguishing Equipment and Systems

CERTIFICATE OF FIRE APPROVAL

Panic & emergency exit devices

GL-001. CIRM Guideline PERFORMANCE TEST PROCEDURE FOR ELECTRONIC CHART DISPLAY AND INFORMATION SYSTEM (ECDIS) Edition 1.

Survey of electrical equipment installed in hazardous areas on tankers

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS

Hybrid Oil Injector Fitting Guide

Evacuation Tragedies Do Happen Kaprun Scandinavian Star Manchester Dusseldorf Airport Kings Cross

NOTTINGHAM CITY HOMES

Guidance on the construction of CO 2 systems

FIRE PREVENTION GUIDELINE

FIRE SAFETY ON BOATS. In partnership with

Guidance Note FIA Application Guidance on BS :2015

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

WORLD CALIMA. Summary report on engine room fire

ISO INTERNATIONAL STANDARD. Safety identification Escape and evacuation plan signs. Identification de sécurité Plans d'évacuation et de secours

COMDTPUB P NVIC JUNE 1995

Appendix H. BGS BR211 Radon Report

UWE CCTV Code of Practice

MV THOMSON MAJESTY Engine-room fire South of Gorgona Island 21 October 2016

Emergency information for local residents

Transcription:

MARINE GUIDANCE NOTE MGN 426 (M) External Access to Means of Escape Notice to all Recognised Organisations, Shipowners, Masters, and Shipbuilders This notice should be read with SOLAS II-2/2 and II-2/13, MSC/Circ.847, ISPS Code A/9.4.2 and B/9.18-9.24. PLEASE NOTE:- Where this document provides guidance on the law it should not be regarded as definitive. The way the law applies to any particular case can vary according to circumstances - for example, from vessel to vessel and you should consider seeking independent legal advice if you are unsure of your own legal position. Summary This MGN highlights the conflict between safety and security with regards to means of escape and provides advice on the methods to overcome the conflict. 1. Introduction 1.1 The conflict between international safety and security requirements with regard to locking the doors on escape routes while providing a means of escape is frequently reported by ship operators and designers. 1.2 This MGN assists those involved in the design, construction, operation and certification of UK ships in identifying a safe means of complying with both the safety and security requirements for escapes. 2. Background 2.1 Many parts of the ISPS Code require doors to be secured against unauthorised access. This includes doors on escape routes. For safety reasons such locks must not impede emergency escape. Over the years many ways for overcoming this conflict have been adopted. Unfortunately some unacceptable methods do not allow access from outside the space in an emergency. 2.2 SOLAS II-2/2.2.1.6 outlines the functional requirements of escape routes, one of which is protection of means of escape and access for fire fighting. - 1 -

Passenger Ships 2.3 SOLAS II-2/13.3.2.6.1 requires Cabin and stateroom doors shall not require keys to unlock them from inside the room. Neither shall there be any doors along the designated escape route which require keys to unlock them when moving in the direction of escape. 2.4 Normally latched escape doors providing escape from public spaces are required to be fitted with a means of quick release. The system for quick release is required to meet specific requirements outlined in SOLAS II-2/13.3.2.6.2. For this reason, not all of the acceptable methods of achieving both safety and security requirements listed in para. 3.3 below may be acceptable for passenger escapes on passenger ships. Cargo Ships 2.5 Although SOLAS II-2/13.4.2.1.2 does not explicitly require every door leading to the open deck to be capable of being opened from both sides, MSC/Circ.1120 outlines the philosophy that means of escape referenced in SOLAS II-2/13.3.3 must be accessible from both sides. It states; The escape routes are routes for escape and also for access. Accordingly, the locking arrangement should be such that it does not obstruct these two objectives (escape and access). Doors along any designated escape routes which require keys to unlock them when moving in the direction of escape should not be permitted. 2.6 The UK interpretation of SOLAS is that all doors on all escape routes must be accessible in both directions in an emergency. 3. Guidance on Compliance with International Requirements 3.1 Methods of Securing Doors 3.1.1 It is recognised that security requires that access to restricted areas is controlled. Both the safety and security requirements have to be met and various methods of achieving this have been employed. 3.2 Examples of unacceptable methods:- dead bolt latches on the inside Planks of wood across the door handles internally Internally lashed doors with emergency knife Door locks with no external keyhole 3.3 Examples of acceptable methods:- Key-pad door locks which in their failure mode open the lock Swipe-card locks which in their failure mode open the lock A padlock key control system and an internal quick release device Door locks with internal release device and an external lock with key control system Latch dogs with a removable handle that require a special shaped head for opening them externally, with the handle readily available for emergency use. Use of customs tags to show restricted area has not been breached coupled with a patrol system to verify integrity of tag Door alarm coupled with a response system to investigate when alarm sounds - 2 -

3.4 The acceptable methods described above also require appropriate operational procedures to be in place to ensure that the means of access is readily accessible in an emergency. Examples of this are: procedures for access to and use of keys and codes; or searches of restricted areas to verify their integrity after a suspected breach. 3.4 If existing locking arrangements fall within the description of any of the unacceptable methods, the locking arrangements should be changed to comply with the international requirements. 3.5 This may involve the removal of internal locking devices that cannot be disconnected from the outside in emergency situations and ensuring that doors which are locked internally using conventional door locks and keys can still be opened externally. 3.6 Changes should be implemented as soon as practicable. In the meantime, any shipboard emergency procedures should take account of the locking arrangements in place. 4. Examples of door securing devices with internal release 4.1 The following diagrams and pictures illustrate two examples of compliance with requirements, in conjunction with appropriate operational procedures to ensure that the locking arrangements are readily accessible in an emergency. 4.2 Diagrams of an acceptable arrangement (not for passenger escapes on passenger ships). - 3 -

4.3 Pictures of an acceptable arrangement (not for passenger escapes on passenger ships). Locked - 4 -

Unlocked More Information Security Policy Manager Maritime and Coastguard Agency Bay 2/18 Spring Place 105 Commercial Road Southampton SO15 1EG Tel : +44 (0) 23 8032 9511 Fax : +44 (0) 23 8032 9371 e-mail: phil.white@mcga.gov.uk General Inquiries: infoline@mcga.gov.uk MCA Website Address: www.mcga.gov.uk File Ref: Published: September 2010 Please note that all addresses and telephone numbers are correct at time of publishing Crown Copyright 2010 Safer Lives, Safer Ships, Cleaner Seas Printed on material containing minimum 75% post-consumer waste paper - 5 -