Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Similar documents
Multi line separator module

Input module, input/output module

Input module, input/output modules

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Mimic display driver, LED ribbon cable

Output module (230 V)

DM1131 / DM1133 / DM1134 Manual call points

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Interbases. Sinteso FDSB221, FDSB228, FDSB229

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDOOT221, FDO221, FDT221

ASA linear smoke detector

OH720, OP720, HI720, HI722

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDCIO223 (ES 45) Transponder

FDCL221-M Multi line separator module

FDOOT241-A9-Ex Multisensor fire detector

FDCL221-Ex Line adapter (Ex)

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

SWING radio fire detection system

Radio fire detection system

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Fire control panels FC360

DF1101-Ex Infrared flame detector

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

DT1101A / DT1102A / DO110xA Automatic fire detectors

OOH740-A9-Ex Multisensor fire detector

FDM273 Radio manual call point Mounting

Fire control panel for modernization

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

DC1192 Input /Output module

OOH740, OOHC740 Automatic fire detectors

OOH740-A9-Ex Multi-sensor fire detector

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Fire control panels FC726 FC726-XA

Test units and accessories

FC724 Fire control panel

Test units and accessories

FC722 Fire control panel

FC722 Fire control panel

FDCW241 Radio gateway Mounting

FC724 Fire control panel

Frost Protection Thermostat

DF1151-Ex Infrared flame detector

FC723 Fire control panel

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Room thermostat with 24-hour time switch and large LCD

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

Electronic timeswitch

FDA241, FDA221 Siemens ASD

FDCI221, FDCIO221 Input module, input/output module Technical Manual

FDCL221 Line separator

FT2080 Fire terminal (Touch) Mounting Installation

Duct Temperature Sensors

FT2080 Fire terminal (Touch) Mounting Installation

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

XC10 Extinguishing control panels

FDL241-9 Linear smoke detector Mounting Commissioning

FC2020 Fire control panel

1592P01. for liquids in piping DN

Test units and accessories

Frost Units for air temperature monitoring

Call stations and extensions

Room Temperature Controllers

Synova TM product catalog.

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

FDA241, FDA221 Siemens ASD

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FP120-Z1 Power supply kit A (70 W) Technical Manual

Room Temperature Controller

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

DOW1171 / DCW1151 Radio fire detection system

Room thermostats with LCD RDD100..

Room thermostat with independent DHW control

Flush-mounted room thermostat

Room Temperature Sensors

Room thermostat with Auto Timer, independent DHW

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDBZ290 Air sampling smoke detection kit Technical Manual

Building Technologies. FDUL221 en Line tester operating instructions for electricians

FS20 Fire detection system

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Sinteso TM product catalog.

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

FDS229 Alarm sounder with supplementary optical indication Technical Manual

Semi flush-mount room thermostats

OH110, OP110, HI110 Automatic fire detectors

FD20 Sinteso Detector system

FS720 Fire detection system (marine) Technical Manual

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Wall-mounted room thermostat with LCD

RVL479. Heating Controller. for use with a partner unit

Transcription:

Sinteso Cerberus PRO Manual call point FDM223H, FDM224H 'Heavy Duty' manual call point addressed (FDnet/C-NET) Manual call points for addressed Sinteso FS20 and Cerberus PRO FS720 fire detection systems Very robust housing design made from fiberglass-reinforced thermoplast For surface mounting in humid, wet and dusty environments Manual call point FDM223H with indirect activation: type 'B' according to EN 54-11 Manual call point FDM224H with direct activation: type 'A' according to EN 54-11 Two-wire installation for all cable types Communication via FDnet/C-NET (addressed individually) 2018-06-15 Control Products and Systems

Properties Features Integrated line separator: The defective part on the detector line is located by the fire control panel and isolated between two FDnet/C-NET devices. Built-in alarm indicator (LED) Protected electronics Two-color LED for alarm and test Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated Functions Manual call point FDM223H Indirect alarm activation by pushing in the glass insert and pressing the alarm button Open the door of the detector with the key to replace the glass insert. Reset the alarm button before closing the door. Protective cover DMZ1197-AC (accessories) protects the manual call point against the glass being broken accidentally. Seal DMZ1197-AC (accessories) protects the manual call point in wet areas 1 2 DMZ1197-AC DMZ1197-AD Legend for manual call point FDM223H: 1 Metal cable gland (accessories) 2 Cable gripper 2

Manual call point FDM224H Direct alarm activation by pushing in the glass insert Open the door of the detector with the key to replace the glass insert. The alarm button is reset when the door is closed. Protective cover DMZ1197-AC (accessories) protects the manual call point against the glass being broken accidentally. Seal DMZ1197-AC (accessories) protects the manual call point in wet areas Fields of application FDM223H and FDM224H For the immediate manual activation of a fire alarm For indoor and outdoor application, also suitable for humid, wet, and dusty environments For surface-mounted cable entry in easily accessible locations only Type Overview Manual call point FDM223H FDMH292-R Red housing with glass, key, 3 cable grippers (2-hole), 2 standard signs with building and fire brigade/fire detector A5Q00005525 0.302 FDME223 Switching unit for FDM223H A5Q00003087 0.071 Manual call point FDM224H FDMH292-R Red housing with glass, key, 3 cable grippers (2-hole), 2 standard signs with building and fire brigade/fire detector A5Q00005525 0.302 FDME224 Switching unit for FDM224H A5Q00009392 0.061 Accessories for the manual call points FDM223H and FDM224H DMZ1197-AC Protective cover BPZ:5223550001 0.012 DMZ1197-AD Sealing for wet areas BPZ:5470680001 0.022 Spare parts for the manual call points FDM223H and FDM224H DMZ1196-AC Glass insert BPZ:4942050001 0.011 - Cable gripper red, M20 x 1.5 (1-hole) - Standard signs with building and fire brigade/fire detector A5Q00006735 0.007 BPZ:5304150001 0.007 3

Product documentation Document ID Name 008164 Equipment overview Sinteso Detector system FD20 008331 List of compatibility (for 'Sinteso ' product line) A6V10229261 List of compatibility (for 'Cerberus PRO' product line) 007002 Technical manual Manual call points FDM223, FDM224, FDM223H, FDM224H 008615 Installation Housing for manual call point 'Heavy Duty' FDMH292-R Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download Notes Mounting Disposal Mounting options Use the opening at the top or the two openings at the bottom for cable gripper M20 (included) or cable glands M20 (accessories). Open cable entries must be closed for IP64 applications. The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 4

Technical data Operating voltage FDM223H / FDM224H DC 12 33 V Operating current (quiescent) 200 µa Ext. Alarm indicator (AI) 2 Operating temperature -25 +70 C Storage temperature -30 +75 C Air humidity (no moisture condensation) Communication protocol Cable cross section Color Protection category (IEC 60529) With seal DMZ1197-AD 95 % rel. FDnet/C-NET 0.28 1.5 mm² ~RAL 3000 flame red IP41 IP64 Standards EN 54-11, EN 54-17 Approvals VdS LPCB DNV GL (Marine) System compatibility FDnet C-NET FDM223H: G205014 531k/09 - FS20, AlgoRex, SIGMASYS FS720 FDM224H: G206124 531k/11 MEDB00003UM 08 07 0786 FDM223H Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. 007002 FDM223H - Manual callpoint incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-11 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20444; DoC No.: CED-FDM223H 0786 FDM224H Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. 007002 FDM224H - Manual callpoint incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-11 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20370; DoC No.: CED-FDM224H 5

Dimensional drawings Manual call point FDM223H/FDM224H 134.3 42.5 134.3 Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2007 Technical specifications and availability subject to change without notice. 6 Document ID Manual FD20/FD720 Edition 2018-06-15 Register 4