Storage Tanks Type NADO

Similar documents
Operation and Installation Manual. Accumulation Tanks. NADO 500/200v7 NADO 750/200v7 NADO 1000/200v7

OPERATING AND INSTALLATION MANUAL

StorMaxx CTEC Series Tanks

OPERATING AND INSTALLATION MANUAL

TANK TYPE INDIRECT WATER HEATERS

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING and INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING and INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

STORAGE TANKS NEWS WITH TRADITION

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

ENAMELED INDIRECT WATER HEATERS

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

WATER HEATERS. Tradition from 1956

WATER HEATERS AND HOT WATER STORAGE TANKS

WATER HEATERS AND HOT WATER STORAGE TANKS

INDIRECT WATER HEATERS

Unvented Electric Water Heater 10/15 litre Undersink

WATER HEATERS AND HOT WATER STORAGE TANKS

Page 1 SERVICE MANUAL. Little flow heaters SERVICE MANUAL

17 OPERATING AND INSTALLATION MANUAL - EN

SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3

Installation and Operating Manual

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Specification / Type INTEGRA 400/100 INTEGRA 500/120 INTEGRA 800/200

BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE Hot Water Storage Tank with Coil

WATER HEATERS FOR CENTRAL UTILITY WATER ENSOL/1

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

INDIRECT SYSTEM FOR FROST LOCATIONS

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

LBF RANGE BALANCED FLUED WATER HEATERS

CORREX MP Anode with external voltage source. Installation & Operation Manual

HOTFLO 10 / 15. Fitting Instructions and User Guide

Installer manual AHP/AHPS

with insulated heating elements for water heaters INSTALLATION AND USER MANUAL WARRANTY CARD

Components for solar heating systems

TECHNICAL PROPERTIES OF THE APPLIANCE

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Installer manual AHP/AHPS

STORAGE WATER HEATERS

CHAPTER 8 CHIMNEYS AND VENTS

WATER HEATERS EN - flyer 03/z/2018 Made in Poland

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Installation and User Instructions HS10U, HS15U.

flue pipes flue pipes

16 XD Mk2 Inset Electric Fire

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

CRU-S Series Stainless Steel Condensate Recovery Unit

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

INTADUO THERMOSTATIC BATH/SHOWER MIXER

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

gorenje GBFU SIMPLICITY

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

CHAPTER 8 CHIMNEYS AND VENTS

Frequently Asked Questions

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Slide 1 Jul 20, 2006 Viessmann UK

Air Entrainment Meter Type A CN025. Impact Test Equipment Ltd & User Guide. User Guide

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

User and Installer manual NIBE UKV 20

CHIMNEYS AND VENTS CHAPTER 8

Knight & Charger Water Heaters

English Piping Guide Vacuum Piping Guide, Building :04

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4.

Charger range. the Knight & Technical Specification. Our conventionally flued gas fired storage water heaters.

INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK

Niles Steel Tank Hot Water Generator Installation and Operation Manual

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

THERMAL STORE MAINS PRESSURE SYSTEM

Recourse to the italian Law - SIENA COURT in case of controversy shall apply.

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Link-Up. Solid Fuel Association Guide to Central Heating.

CHART PERUVIAN TECHNICAL STANDARDS

User s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel.

THERMAL STORE MAINS PRESSURE SYSTEM

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Unvented water heating

Air/water - Heat pumps

Aquaflam Wood boiler stoves and fireplace inserts

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

VAPORETTINO LUX A B C E. Fig.1 Fig.2 Fig.3 Fig.4. Fig.5 Fig.6 Fig.7 Fig.8. Fig.9 Fig.10 Fig.11. Vaporettino Lux 1R02

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Transcription:

Operation and Installation Manual Storage Tanks Type NADO Družstevní závody Dražice strojírna s.r.o. (Works Cooperative - Dražice Machine Plant, Ltd.) Dražice 69 29471 Benátky nad Jizerou Tel.: 326 370911, fax: 326 370980 www.dzd.cz dzd@dzd.cz

EN Operation & Fitting Instructions 1. Description Storage tanks serve accumulation of excessive heat from its source. The source may be a solid fuel boiler, heat pump, solar collectors, fireplace inserts, etc. Some types of storage tanks allow combination of connecting even multiple sources. The NADO type storage tanks serve accumulation of heat in the heating system and allow heating or preheating of HSW (Hot Service Water) in an inner vessel. Incorporation of a storage tank in the heating system with a solid fuel boiler allows an ideal run of a boiler at favourable temperature during the boiler operation. The main benefit lies in the period of optimum operation (i.e. with maximum efficiency) when the excessive unconsumed heat accumulates in the storage tank. The tanks and potential tubular exchangers are made of steel, without the inner surface treatment, the outer surface of the tank is provided with a protective paint. The storage tanks are equipped with a removable 100 mm thick Symbio insulation made of polyurethane sheet. The storage tanks are manufactured in 500, 700 and 1000-litre volumes. Individual versions are additionally equipped with one or two tubular exchangers, each of 1.5 m 2 area and an inspection hole of 182 mm clearance with an option of installation of an in-built electric heating unit TPK. The NADO type enables direct heating of HSW (Hot Service Water) in an inner enamelled vessel, or its preheating for next water heater. Connection to a boiler usually allows direct HSW heating in the inner vessel to the desired temperature whilst, on the contrary, connection to solar collectors or heat pump only preheats HSW and another, e.g. electric, heater has to be used, in order to complete heating the water to the desired temperature, or final electric heating has to be fitted in the storage tank which is enabled either by the electric heating unit TJ 6/4, or by the heating flange TPK. 2. General dimensions Capacity ( l ) Diameter ( mm ) Height ( mm ) 500 600 1990 750 750 2020 1000 850 2053 3. Description of individual versions NADO v1 Storage tank with a flange of 210 mm screw spacing. The flange can be used for assembly of an in-built electric heating TPK flange unit. In the standard version, the flange is blinded. The delivery includes insulation of 100 mm thickness. The storage tank contains an inner enamelled vessel of 100, 160 or 200 litre capacity, depending on the size of the storage tank. NADO v2 Storage tank with a flange of 210 mm screw spacing for the assembly of an in-built electric flange heating unit TPK and one exchanger of 1.5 m 2 area for connection of an additional heating system (e.g. SOLAR). In the standard version, the flange is blinded. The delivery includes insulation of 100 mm thickness. The storage tank contains an inner enamelled vessel of 100 or 140 litre capacity, depending on the size of the storage tank. NADO v3 Storage tank with a flange of 210 mm screw spacing for the assembly of an in-built flange electric heating unit TPK and two exchangers, either of 1.5 m 2 area for connection of an additional heating system (e.g. SOLAR). In the standard version, the flange is blinded. The delivery includes insulation of 100 mm thickness. The storage tank contains an inner enamelled vessel of 100 litre capacity, depending on the size of the storage tank.

4. Illustration of NADO versions and description of outlets

5. Designing the size and connection of storage tank to the heating system An ideal size of the storage tank is designed by a design engineer, or a person sufficiently qualified to design heating systems. Product assembly must be implemented by an authorised person (confirmed in the warranty certificate). Prior to commissioning, we recommend that you run the heating circuit and any impurities that are trapped in the filter clean, then the system is fully operational. 6. General Technical Parameters The maximum operating pressure in the storage tank is 0.3 MPa. The maximum heating water temperature in the storage tank is 90 C. The maximum operating pressure in the inner vessel is 0.6 MPa. The maximum hot service water temperature in the inner vessel is 90 C. In version 2 a 3 additionally: The maximum operating pressure in the exchanger is 1 MPa, the maximum temperature of heating water in the exchanger is 110 C. Important: When putting into operation, water has to be filled first into the inner vessel for HSW and the operating pressure inside it has to be kept, only then heating water can be filled into the outer storage tank, otherwise the product may get damaged! The manufacturer explicitly emphasises the necessity of being particular in testing the tightness of the heating circuit (radiators, piping joints, floor heating, etc.) with the connection of the storage tank. No pressure grow in the storage tank heating water compartment may occur above the maximum operating pressure of 0.3 MPa, if the heating system is pressurised to higher than the maximum operating pressure, the inner enamelled vessel may get permanently damaged! No stop fitting can be put between the security fitting of the heating circuit and the storage tank!!! It is recommended to use the product in an indoor environment with air temperatures from +5 C to 45 C and a maximum relative humidity of 80%. Safety valve has to be fitted on the cold water inlet. Each hot service water pressure heater must have a safety valve with a membrane spring. Nominal clearance of safety valves is defined in the ČSN 0 60830 standard. The heaters are not equipped with a safety valve. The safety valve must be easily accessible, as close to the heater as possible. The input pipes must have at least the same clearance as the safety valve. The safety valve is placed high enough to secure dripping water drain by gravity. We recommend mounting the safety valve onto a branch pipe. This allows easier exchange without having to drain the water from the heater. Safety valves with fixed pressure settings from the manufacturer are used for the assembly. Starting pressure of a safety valve must be identical to the maximum allowed heater pressure, and at least 20% higher than the maximum pressure in the water main. If the water main pressure exceeds such value, a reduction valve must be added to the system. No stop valves can be put between the heater and the safety valve. During the assembly, follow the guide provided by the safety equipment manufacturer. It is necessary to check the safety valve each time before putting it into operation. It is checked by manual moving of the membrane from the seat, turning the make-and-break device button always in the direction of the arrow. After being turned, the button must click back into a notch. Proper function of the make-and-break device results in water draining through the safety valve outlet pipe. In common operation, such a check needs to be implemented at least once a month, and after each heater shutdown for more than 5 days. Water may be dripping off the drain pipe of the safety valve; the pipe must be open into the air, pointed down; environment temperatures must not drop below zero. When draining the heater, use a recommended drain valve. First, close water input into the heater. Find necessary pressure values in the following table. Safety valve starting pressure (MPa) Admissible operating water heater pressure (MPa) Max. pressure in the cold water pipe (MPa) 0.6 0.6 do 0.48 0.7 0.7 do 0.56 1 1 do 0.8

NADO 750/100 v1 NADO 750/100 v1 NADO 750/160 v1 NADO 750/160 v1 NADO 750/200 v1 NADO 750/200 v1 NADO 750/250 v1 NADO 750/250 v1 NADO 750/100 v2 NADO 750/100 v2 NADO 750/140 v2 NADO 750/140 v2 NADO 750/100 v3 NADO 750/100 v3 NADO 500/100 v1 NADO 500/100 v1 NADO 500/160 v1 NADO 500/160 v1 NADO 500/200 v1 NADO 500/200 v1 NADO 500/300 v1 NADO 500/300 v1 NADO 500/100 v2 NADO 500/100 v2 NADO 500/140 v2 NADO 500/140 v2 NADO 500/100 v3 NADO 500/100 v3 For proper safety valve operation, a backflow valve must be mounted on the inlet pipes, preventing spontaneous heater draining and hot water penetrating back into the water main. We recommend that the hot water distribution from the heater was as short as possible to minimise heat losses. Heaters must be provided with a discharge valve mounted on the cold service water inlet to the heater for potential disassembly or repair. When assembling the security equipment, follow ČSN 06 0830. We recommend checking and cleaning the storage tank from scale and eventual replacement of the anode rod after two years of operation. The anode life is theoretically calculated for two years of operation; however, it changes with water hardness and chemical composition in the place of use. Thermal insulation Polyester sheet of 100 mm thickness. It consists of an upper cover, flange cover and hole caps. Insulation is supplied in a separate packaging. We recommend that the insulation was fitted at room temperature. At temperatures significantly below 20 C the insulation shrinks. This disables its easy fitting. Technical parameters Standing loss (W) 80 132 80 132 80 132 80 132 79 130 79 130 80 132 Storage tank volume (l) 475 475 475 475 475 475 475 475 475 475 475 475 475 475 Standing loss (W) 117 156 117 156 117 156 117 156 117 165 116 154 117 156 Storage tank volume (l) 772 772 772 772 772 772 772 772 772 772 764 764 744 744

NADO 1000/100 v1 NADO 1000/100 v1 NADO 1000/160 v1 NADO 1000/160 v1 NADO 1000/200 v1 NADO 1000/200 v1 NADO 1000/100 v2 NADO 1000/100 v2 NADO 1000/140 v2 NADO 1000/140 v2 NADO 1000/100 v3 NADO 1000/100 v3 Standing loss (W) 130 183 130 183 130 183 128 180 128 180 130 183 Storage tank volume (l) 999 999 999 999 999 999 987 987 987 987 971 971 30-9-2015