Centrifugal Fans, Non-Overloading, Backward Inclined

Similar documents
CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

A. Codes and Standards that are Standard at the University:

Selecting the Correct Fan

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Twin City Fan & Blower

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Introduction to Fans. The Basics of Fan Principles and Terminology

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Fans: Features and Analysis

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

an ISO 9001 Company Bulletin PR-112

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

An ISO 9001 : 2008 Certified Company SUBURBAN INDUSTRIAL WORKS (LESSEE)

Fan Arrangements, Rotation, Discharge and Motor Position

JM Aerofoil Fans Bulletin JMA60-05

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

Ducted Propeller. Airflow Volume

CML Northem Blower Inc. Air Movement Equipment

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SECTION (15833) - HVAC POWER VENTILATORS

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Double Skin Air Handling Units

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Centrifugal Blower. Backward/Aerofoil Curved.

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

Practical Consideration of Noise from Fans

Miniveyor. Tough Fans for Tough Jobs! NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.

Wilo IL Vertical Split-Coupled Inline Pumps

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Horizontal Split Case Pumps Type U

Twin City Fan & Blower

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

Understanding Fan System Effects

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

fans & heaters SIMPLE, ROBUST AND RELIABLE

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Jethwa Automatic Can Equip. Co. An Export Award Winning ISO 9001 Quality Certified Company

Industrial Fans & Blowers

Glossary of Terms Laboratory & Fume Exhaust Fans

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service

CUSTOM PRODUCTS AND SERVICES GUIDE

R. K. Engg. Works Private Limited

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

The Advantages of Choosing Centrifugal Fans

Axial flow fan AXICO ANTI-STALL

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

FAN ENGINEERING. Sealing of Fan Housings

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Company History Locations Product range References

Tunnel Axial Flow Fan

CAP SERIES SEWAGE AND WASTE WATER PUMPS

With the world-renowned SIGMA PROFILE

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Commercial Evaporative Cooling

Double Skin Air Handling Units

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton

Great for Rental Stackable: Constructed with interlocking ribs for stacking vertically. Great for storage as they need a minimal footprint

Varius Application of Dynair Fans

HEAT RECOVERY AIR HANDLING UNIT

MAS AIR SYSTEMS, LLC (724) mas-fan.com PRODUCTS AND SERVICES GUIDE

REVERSING DRUM MIXER

University of Houston Master Construction Specifications Insert Project Name

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Marley Ultra Quiet Fan

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems

ROTARY DRYER CONSTRUCTION

MXI Mixed Flow Inline Fan

CombiBloc Close-coupled centrifugal pumps

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE

CR A-F-A-E-HQQE 3x400/ HZ

Scirocco (tri-lobe) blowers Tri-lobe design for higher efficiency and reduced noise levels in the Water Industry

5 year fan housing and motor warranty

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

HOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

What is the correct type of fan: Axial, radial, diagonal?

DUST COLLECTORS. OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

Centeral Station Air Handling Unit

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

ARI 260 Standard: Sound Rating of Ducted Air Moving and Conditioning Equipment

Transcription:

BACKWARD INCLINED CENTRIFUGAL FANS Centrifugal Fans, Non-Overloading, Backward Inclined MVA, MVZ, MVX & MVW Series with laminar blades MAVA, MAVZ & MAVX Series with aerofoil blades Features The combination of scientifically designed aerofoil or laminar ( single thickness) blades with the highly desirable non-overloading power characteristic of backward inclined blades produce fans that offers the ultimate in high efficiency and quiet operation. The laminar bladed fan is used for general purpose applications and can tolerate very light dust load while the higher efficiency aerofoil bladed fan is used to achieve substancial power saving in large sized fans. The aerofoil bladed series are only suitable for clean air applications. Both single width single inlet (SWSI) and double width double inlet (DWDI) fans are available. For DWDI fans delivering twice the volume at the same static pressure, multiply fan RPM by 1.01, and multiply fan absorbed power by 2.04. The above fans are custom built to optimise the mechanical design to achieve excellent performance that will assist our customers to find competitive solutions to their air movement problems. All the fan components are liberally sized to ensure long trouble free life. The mechanical design can be tailored to meet different operating conditions ie. temperature, corrosion, noise, dust load, humidity, abrasion, space limitation etc. The fan handing can be adapted to meet your specific requirement without restrictions. Construction Casing - Heavy welded construction from plate steel. Side plates stiffened to prevent drumming. Scroll designed to optimise fan pressure developed by impeller. Impeller - ruggedly built, welded mild steel construction, dynamically balanced to International Standard ISO 1940, to ensure smooth running without vibration. Pedestal - top & sides fabricated from heavy mild steel plate. Optional Extras Silencers, lagged casing, filters, guards, dampers, inlet boxes, variable inlet vanes, anti-vibration mounts, matching flanges, flexible connections, wear plates on impeller and housing, split housing, corrosive resistant coatings, stainless steel housing & impeller, anti-sparking construction. Laminar SWSI Aerofoil DWDI Applications General air handling, pneumatic conveying, pollution control, ventilation, drying, cooling, exhausting, extraction of fumes, chemical processing, combustion, food processing etc. MAVA 320 fan, Arr.1, 45kw c/w discharge damper, silencer and elbow. Grain dust collection system. 50

BACKWARD INCLINED CENTRIFUGAL FANS MVZ 630 Fan, Arr.8, Coupling Driven, 300kw MVZ 191 Fan, Arr. 9 with cooling fin for high temperature MVW 360 Fans, Arr. 1, 75kw MVX 240 Fan, Arr. 9, 7.5kw MAVA 540 Fan, Arr.3, DWDI, 90kw c/w discharge damper MVZ 340 (75kw), MVX 340 (55kw) and MVX 240 (30kw) Fans, Arr. 1 c/w discharge silencers 51

MVA SERIES 52

53 MAVA SERIES

MVZ SERIES 54

55 MAVZ SERIES

MVX SERIES 56

57 MAVX SERIES

MVW SERIES 58

59 MVA, MAVA, MVZ, MAVZ SERIES

MVX, MAVX SERIES 60

61 MVW SERIES

MVR SERIES MVR Series Radial Tip Centrifugal Fans The MVR range of radial tip centrifugal fans are similar in contruction to the laminar bladed centrifugal fans. However the impeller blades are curved at the leading edge while the blade tips are radial to provide a self-cleaning action. Radial tip centrifugal fans are used mainly in large sizes (above 750 mm wheel diameter) for light to moderate loading of dust, dirt, powder, flakes, process exhausts and industrial applications involving hot gases. The radial tip is an important feature in the presence of dust, fly ash etc. Material buildup on the blade, which causes unbalance and vibration is avoided. Wear plates for abrasive particles can be supplied. MVR fans do not have the non-overloading characteristics and have a steadily rising power curve. 62

M SERIES M Series Dust Fans Rugged construction provides long trouble free performance under arduous conditions. The impellers have radial blades which are easy to clean and prevent material build-up or deposit. Its rigid construction from heavy steel plate will ensure many years of trouble free service. Radial bladed fans produce a power curve which is almost a straight line rising from a minimum at zero flow to a maximum at maximum flow. These fans normally do not surge or pulsate at low volumes. At high speeds they tend to be noisy. Types Of Impellers And Applications: Type M Impeller - the radial blades are welded to the backplate and front shroud. This impeller is suitable for air containing granular material, sawdust, grain, particle laden industrial process air or gases. Type L Impeller - the radial blades are welded to the backplate with an open front. This impeller is designed for handling long stringy material, fibrous material such as textile scrap, wool, wood shavings and paper trim segments. It is not suitable for continuous paper trim handling. Type O Impeller (paddle) - the radial blades are welded to a heavy duty steel hub. This impeller is designed for heavy or abrasive dust, conveying of air or gases containing sticky material that would have a tendency to build up on other types of impellers. The paddle design facilitates coating or attaching replaceable bolt-on wear plates. Chopper Impeller - the radial blades are welded to a conical backplate with an open front. This impeller has polished surfaces and is designed for handling continuous paper trim. The blades of the impeller have sharp and hardened cutting edges, which can be supplied as a bolt-on option. Construction Casing - heavy welded construction from plate steel. Side plates stiffened to prevent drumming. Scroll designed to optimise fan pressure developed by impeller. Pedestal - top & sides fabricated from heavy mild steel plate. Optional Extras Anti-vibration mounts, matching flanges, split housing, corrosive resistant coatings, stainless steel housing & impeller, anti-sparking construction, high temperature construction. Arr. 1 Belt Driven Chopper Fan with Cutting Edges on Impeller, Arr. 9 63

M SERIES 64

65 M SERIES

M SERIES 66

67 M SERIES

MINE VENTILATION FANS Mine Ventilation Fans Two-Stage Axial Flow Fans - Contra-Rotating Features * High Quality Aerofoil Bladed Cast Aluminium Impellers * Robustly Designed Casings, Flanges & Motor Mounting Brackets * Fully Welded Construction With Heavy Duty Hanging Brackets * Totally Enclosed Air Over Motors, With Minimum IP55 Protection * External Terminal Boxes - Fully Welded Steel Construction * Wire Mesh Guards At Fan Inlet For Protection * Bag Adaptors At Fan Discharge (Optional) * Inlet Cone With Guard (Optional) * External Greasing Points For Motors (Optional) Proven Performers - Over the past 20 years, our extensive skills and experience have gone into supplying numerous contra-rotating axial flow fans for underground mine ventilation throughout Australia, particularly the Kalgoorlie region of Western Australia. AF 1220 Two Stage Fan, Heavy Duty, 55kw per stage 68

MISCELLANEOUS Inline centrifugal fans The Aerotech inline centrifugal fans are heavy duty industrial type, non-overloading fans which are quiet and compact. The consolidation of the centrifugal wheel in a tube with guide vanes produce a highly efficient performance characteristics comparable to scroll type centrifugal fans but with minimum space requirements similar to that of axial flow fans. The tubular design eliminates the need for duct turns and transition pieces, thus providing simpler and less costly installation. The inlet and outlet diameters are identical and the fan can be mounted vertically or horizontally. Acoustically Lagged Centrifugal fans The Aerotech range of centrifugal fans can all be acoustically lagged to reduce radiated noise from the fan casing. The whole casing is double skinned and insulated with sound absorbent material. It is more economical to purchase a lagged fan than to acoustically insulate the fan casing on site to meet the necessary noise requirements. MVX 320 s/s fan, Arr.1, 90kw HP 332 fan, Arr.8, Coupling Driven, 22kw HP 406 fan, Arr.1, 120kw Petrol Engine Driven centrifugal fans These fans are ideal for use in remote areas where electricity supply is not easily available. Plug Fans for high temperature The Aerotech plug fans are solidly welded, non-overloading fans which can be square panel mounted to the side or top of oven dryer panel. The mounting panel is insulated. These fans are designed for internal operation in furnaces, ovens or kilns where air has to be exhausted, re-circulated, or distributed. Plug units eliminate ductwork and special mounting platforms. F 24 Fan MVZ 160 fan Direct Driven Belt Driven 69