CASE STUDY: WASTEWATER TREATMENT

Similar documents
TECHNOLOGIES AND EQUIPMENT FOR WASTEWATER TREATMENT RAKE BAR SCREEN

THE EQUIPMENT. TECHNOLOGIES AND EQUIPMENT for wastewater treatment MECHANICAL TREATMENT AIR DIFFUSERS EQUIPMENT WE TRUST FOR CLARIFIERS

CHAMBER- MEMBRANE FILTER PRESS. Guaranteed efficiency without worries

HEADWORKS PERFORATED PLATE FILTER SCREEN ROTARY DRUM SCREEN IN CHANNEL PERFORATED DRUM SCREEN

JIWET technical report. 8. Rotary Screen

Fifth Annual Waste Treatment Symposium, September Kelly Brown, BDP Industries, Inc.

Web:

FATS, OIL AND GREASE (FOG) PROGRAM

Development of Boiler Design

hydrogone horizontal disc dryer A robust and proven design for high capacity sludge drying

Ultra High Dispersing: increased dispersion efficiency and considerable steam savings

Content. 1 Basics. 2 Detailed Information on different types of Vacuum technologies. Vacuum sanitary installations. Vacuum sewer systems

Technical Memorandum. 1 Summary Findings and Conclusions. SMCSD Headworks, Primary and Secondary Treatment Pre-Design

Exploring Vacuum Technology in Pharmaceutical Processing FDA Eases-the-Way for Processors to Automate Processing Lines with Safer, Faster and

Summary of Conversion Steps. 1. Obtain the abandonment/conversion permit from the Department of Health.

REGISTER YOUR PRODUCT. for warranty claims INSTALLATION PROOF. Please complete and return

What To Consider When Selecting A Filter-Press Pump

Complex Solutions.

Moving to the Cloud: The Potential of Hosted Central Station Services

ACE KOREA INCORPORATION

Improved Dryer Control

Huber s New Q-Press. Presented by: Steve Macomber Huber Technology, Inc.

HEIN-HESØ cleanliness in perfection Worldwide distribution of German/Danish quality Our recipe for success customer orientation

AIRVAC sewer systems are reliable, dependable, and will save you money.

Compression of Fins pipe and simple Heat pipe Using CFD

Overview of Haarslev s Approach to THP

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

* Automatic boiler for burning pellets with power 8kW r. The smallest, certified boiler * in Poland 8kW

AUTOMATIC SOLUTION FOR CONTINUOUS OUTPUT OF MILL-SIZE BALES

Drying and cleaning plant for reprocessing of plastics

PUTTART VERTICAL DRYER-GRANULATOR SLUDGE DRYING AND GRANULATING IN ONE

EN l CartWash Plus. CartWash Plus. Hygienically perfect cleaning of laundry carts

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

* Automatic boiler for burning pellets with power 8kW r. The smallest, certified boiler * in Poland 8kW

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Commonwealth of Virginia Department of Health Division of Onsite Sewage, Water Services, Environmental Engineering and Marina Programs

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

Domino VGS-F.O.G. Domino VGS - F.O.G* Fat, Oil & Grease Separator. Separated Fat, Oil & Grease. Inlet Elbow Sludge Outlet

CLIENT PROJECT. Schematic representation of sludge treatment at WWTP Homburg

INTEGRATED CLEANING SYSTEM TOUCHLESS CLEANING SOLUTIONS

Girapac and Girasieve Rotating drum screens for wastewater pre-treatment

LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES

6 Growth Management Challenges and Opportunities

Filtration Equipment Vertical Plate Pressure Filter VPA

VT-DESOL2 DESOLDERING STATION DESOLDEERSTATION STATION DE DESSOUDAGE ENTLÖTSTATION USER MANUAL GEBRUIKERSHANDLEIDING MANUEL D'UTILISATION

Wastewater produced by chemical plants contains very few fibers, so dewatering the sludge is difficult.

Tel Group

AUTOMATIC BAR FEEDING MECHANISM FOR POWER HACKSAW MACHINE

Don t Screw Press Around: Applying Screw Press Technology to WTP Residual Solids Dewatering

Walker Process Equipment Division of McNish Corporation 1

Application of ALPHA Inverter in the Transformation Plan of Central Air-Conditioning

Introduction. General requirements when using the heat pump

Biosolids Technology Fact Sheet Recessed-Plate Filter Press

SUMMER VILLAGE OF SUNRISE BEACH

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

New requirements for IEC best practice compliance

EARTH FAULT METER MD-08

Irrigation for Lawns and Gardens

LTV - LTV-N Air Handling Unit

Joseph Florio, Commissioner of Pub. Works Tel

Screening and Grit Removal presented by Doug McCord EnQuip.com

Inline Sludge Screens Municipal and Industrial Applications

THE A.A.B. COMPANY 615 McCallie Avenue Chattanooga, TN

Advantages of the Sanosil Q-Jet devices

A New Approach to Dust Monitoring

FEEDGAS FOR MODERN HIGH-PERFORMANCE OZONE GENERATORS. Bruce T. Stanley. Ozonia Ltd Duebendorf, Switzerland 1999

SOLAR Sludge Drying NATURETECH ENVIRO PROTECTION LTD. I+M GMBH & CO.KG

CONTAINMENT AND DEWATERING OF MINE TAILINGS WITH GEOTEXTILE TUBES AT A SILVER MINE IN SAN LUIZ POTOSI, MEXICO

EST User Manual. (Please read this manual carefully before using)

Sedimentation. Photo Credit: Virginia Department of Health

What is a Closed circuit Cooling Tower (CCT)?

Świętokrzyskie region (PL): Modern water supply and sewerage disposal for more effective utilisation of local assets.

PROFILE. industrial services rental trading

Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Komline-Sanderson Paddle Dryer. Drying technology for biosolids, sludges and by-products

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

ANAEROBIC DIGESTERS HEATED BY DIRECT STEAM INJECTION: EXPERIENCE AND LESSONS LEARNED

Beverage Processing System

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

Solids Handling and Reduction Choices for Wastewater Applications

Meeting the Requirements of NFPA 820:

Biosolids dewatering using super absorbent polymers (SAPs) Mostafa M.Noureldin Illinois Institute of Technology

Inta City Concealed Shower Mixing Valve CT80010CP

Coastal Community Convinced about Vacuum Sewers

How to install Solar Water Heater Systems?

88MLV Series Open Channel Modular UV Systems

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

MODERN BELT DRYING OF SLUDGE INNOVATIVE SLUDGE AND ENERGY MANAGEMENT

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Nikita Engineers, Vadodara

Danfoss the world s biggest producer of radiator thermostats

dryer power consumption Why DE Hybrid saves energy Operational savings Seasonal savings ambient temperature débit d air comprimé

STONE WOOL SUBSTRATES

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

INTELLIGENT AXIAL FAN user's manual

OWEA Biosolids Specialty Workshop December 3, 2015

DAIKIN Huizhou Factory Profile

Optimum Design of a Solar Desalination Process IPRO 304-e

Transcription:

TECHNOLOGIES AND EQUIPMENT FOR WASTEWATER TREATMENT CASE STUDY: WASTEWATER TREATMENT PROJECT CLIENT OBJECT LOCATION Modernization of the mechanical wastewater treatment facility Wodociągi i Kanalizacje Miejskie Spółka z o. o. w Augustowie Augustów WWTP Augustów, Poland COMMISSIONING January 2017.

The Municipal Wastewater Treatment Plant is situated in the southern part of Augustów. Its capacity is 10 000 m 3 /d. In 2016 EKOTON Company was chosen to implement investment project for the modernization of the main sewage pumping station which located at the Augustów WWTP. Within the project, the following equipment for mechanical wastewater treatment facility was produced, installed and commissioned: 1. Rake bar screen RKE; 2. Screw compacting press SCP; 3. Slide gates of ZSg type; 4. Facility control system. The aim of the pumping station modernization was to increase the efficiency of mechanical impurities removal and waste thickening with full automation of the process. INITIAL STATE: In accordance with initial project, wastewater was fed via two collectors into the pumping station, where it was mechanically treated on the screens with 25 mm mesh.. Screen cloth cleaning was carried out manually by the personnel as it became clogged. The removed waste was fed into the container for its further lifting by means of lifting device to a zero mark (ground surface) into a receiving tank. The main problems which were occurring during operation of the old equipment are following: The need of constant monitoring of the screen cloth to prevent pump station flooding and emergencies; High cost of the screen cloth cleaning and further waste transportation into receiving tank; Pumping equipment and further stages emergencies occurring due to insufficient removal of mechanical impurities.

PROJECT IMPLEMENTATION: One of the key complication during the project implementation was installation of equipment in existed pumping station among which: The building was not designed for installation of equipment with length of more than 2,5 m, thus there was a requirement to produce rake screen with 6 m length from separate parts with length of 2 m max. Every part was mounted on supporting structure which were brought together inside the pumping station for further parts assembling inside the building. Pic. 1. Manual cleaning grille Pic. 2. The waste removal mechanisms Pic. 3. Mounting of equipment at the pumping station Pic. 4. The screen installed at the pumping statio

RESULTS: The modernization project allowed to achieve the following results: 1. After the new rake screens installation with 5 mm mesh, the amount of removed waste was increased by 2 times. 2. Due to the partial waste dewatering with screw compacting press SCP, its overall mass has decreased more than 3 times. 3. The necessary time for equipment maintenance reduced more than by 95 % due to its replacement on the new one which operates in fully automatic mode. It should be also noted the additional advantages achieved by mechanical wastewater treatment equipment replacement: considerable decreasing of emergencies and scheduled repairs on the next stages of wastewater treatment technological process. Full elimination of the need for manual labor which were necessary for waste removal earlier. It has significantly improved not only the sanitary condition at the pumping station, but also the labor conditions of the personnel. The quantity and mass data of the waste removal from the screens in period from 2015 to 2017 is given below in figures. The pumping station modernization was carried out in the fourth quarter of the 2016 and in January 2017, the new mechanical treatment facility was launched; the data from that year indicates significant treatment parameters improvement. Reliable screen and screw press design provide the treatment facility with a possibility of round-the-clock and trouble-free operation of equipment in automatic mode. Daily maintenance and inspection requires no more than 15 min. 83,94 28,93 31,09 21,70 23,32 16,46 2015 2016 2017 Объем Waste отбросов volume, m³ м³/год / year. Масса Weight отбросов of waste, тонн/год m³ / year. Pic. 5. The amount and mass of wastes removed from the screen in the period from 2015 to 2017

15 185 Manual screen Automatic screen Pic. 6. Time for equipment maintenance in minutes per day CONCLUSIONS: : The mechanical treatment facility modernization at the sewage pumping station allowed to organize efficient wastewater treatment from large and average impurities. Removed wastes are rinsed for organic part reduction and are thickened on the screw press for its volume and weigh reduction. Installed mechanical treatment facilities operate in fully automatic mode and do not require constant personnel presence. The mechanical treatment process improvement allowed to solve all of the set challenges and assured stable and uninterrupted wastewater treatment process operation. www.ekoton.com eu@ekoton.com +48 87 620 06 02