ISMV STREAMING MOTIONVIEWER

Similar documents
XTO-IP ALARM PANEL. Description. Supervised Wireless Technology. Features

XL200L/600L/700L GPRS Control Panel

Indoor MotionViewer IMV 200/601/701

XV 210 GPRS Control Panel

XT-iP 210 Control Panel

OMV OUTDOOR MOTION VIEWER

SZ-PIR04N ZigBee Motion Detector Installation Guide

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Wi-Fi DOOR/WINDOW SENSOR

Badge Reader BR Installation Guidelines. Product Summary

1100D Wireless Receiver

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

1100X Wireless Receivers

Panel XTO210/610/710 GPRS

2 x screws. 2 x wall plugs

Panel XT210/610/ Description. Supervised Wireless Technology

ADT. Pulse 2017ADT LLC

PET IMMUNE PIR MOTION DETECTOR

Atomic Digital Office Clock

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

ShockLink. Important Product Information.

Wireless Outdoor Air Reset Adaptor PN:

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Pet Immune SAW PIR Motion Sensor

Smart Hub THERMOSTAT. Installation Manual

Wireless External Alarm

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Smart THERMOSTAT. Installation Manual

Wireless Weather Station

Optima ZigBee Thermostat

Draft - develop and review

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

Automatic Dimming Mirror with HomeLink

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

Features and content. This is where air comes into your detector.

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

1126 Series Ceiling Mount PIR Motion Detector

Impassa CDMA Module INSTALLATION GUIDE

Rev D 3/20/17

Smart Radon Detector with Indoor Air Quality Sensors

EL-TSTAT Owner s Manual

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD240)

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions (YRD220)

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Yale Real Living Touchscreen Lever Installation and Programming Instructions (YRL220)

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

1 Copyright 2015 Alarm.com. All rights reserved. Rev 3.4

1 Copyright 2014 Alarm.com. All rights reserved. Rev 3.3

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

Technical support is also available by or by phone: (North America) (International)

InTemp CX Temperature Logger (CX40x) Manual

Save these instructions This product is for household only

EN1221S-60 Waterproof Pendant Installation and Operation Manual

GARAGE DOOR OPENER KIT

Regulatory Compliance and Safety Information for Contol4 Model C4-16AMP3-B.

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Touchscreen Comfort Control

Install Guide TP-2014-IG-V02

1164/1164NS WIRELESS SMOKE DETECTOR

BE1310 Visit Smart hub

S541.RF 4G Product Guide

Installer Guide smart connect

Installer Guide smart connect

Water Sensor. Model CFWS10

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

CLIP PG2 PowerG Wireless, Curtain, PIR Motion Detector

1125 PIR Motion Detector

How to install your ecobee4

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

Contents. User Manual GA-U-1. VultureNet: Long Range System

Caught a critter in the act?

Intelli-Time Alarm Clock model 13041RM

ecobee 3 Quick Start Guide Installation Guide DRAFT

Remote Notification System Instruction Manual

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

Wireless Alarm Bar TM Installation Guide

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

ADC-T2000. Smart Thermostat v1.5

Nest x Yale Lock Programming/Troubleshooting Guide

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

EC-100 Energy Controller User Guide

safety & regulatory information

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

Door/Window Sensor Installation Instructions

Smoke Bridge Owner s Manual

Videofied Distributor Asfales - Oude Molenstraat Mol (b) (0)

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Performance Thermal Binder

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

Transcription:

DOC. - REF. -ISMV MODIF. DATE : MARCH 07 Main features The ISMV 00/60/70 is a wireless, battery-powered, motion activated indoor video camera. It can also be activated by user request. Wireless technology for optimal security. Color video (lighted sites) or black & white (night vision). Infrared LED for night vision. Standard motion coverage lens. Wall and cover tamper. Powered by 3 Lithium CR3A batteries for extended autonomy. Device supervision every 8 minutes. Video capture and transmission in «streaming mode» on user request. Flat wall mounting holes Installation guidelines For an easier installation, programming and RF testing should be done to check for good communication between the control panel and all system devices before mounting. Install the detector and other system devices in the following order: > Programming / RF Testing: Program detector and all other devices into the control panel and test RF communication at each intended device location to the control panel. > Mounting: Mount detector at the tested location. Corner mounting holes Only use of the 4 mounting holes. or. Mounting rules > Use proper tools and hardware. > Mount indoors in a temperature controlled environment. > Mount camera.m from the floor. > Respect Top and Bottom side of the Motion Viewer > When possible, mount in a wall corner in order to aim at a complete room > Mount detector on an outside wall, aimed at area to protect. > Do not aim detector at windows, especially those that let in direct sunlight, or at heat sources such as lamps, fireplaces, radiators and heating vents. > Do not aim detector at moving objects such as curtains, fans or animals. > Do not cover the Fresnel lens.

Programming / RF Testing / Mounting The following provides summarized steps for device programming,testing, and mounting. For complete details, refer to the control panel installation manual. Loosen bottom screw Separate base from ISMV Install 3 CR3A 3V batteries, observing correct polarity. 3 Enter the panel into programming/configuration mode. 4 Using a programmed alphanumeric keypad, proceed through menus until the display shows ADD A NEW DEVICE. 5 Press OK. The display shows PRESS PROGRAM BUTTON OF DEVICE. 6 Press and release the program button on the ISMV 3 using a paper clip. The ISMV LED flashes red 4. 3 Wait for the keypad to display : CAMERA REGISTERED. 7 Press OK, the keypad displays RADIO RANGE TEST? Press OK again. The ISMV LED starts flashing and the keypad displays TEST IN PROGRESS. 8 Move the ISMV to the intended mounting location and confirm the signal is 9/9, indicating good communication with the control panel. 4 9 Press OK to end the radio range test then press ESC/NO. 0 The display shows : AREA ALLOCATION : AREA : Press either arrow button on the keypad until the desired AREA number appears, then press OK. By default all devices in area will be subject to the entry and exit delays. The screen displays NAME + LOCATION : Enter an appropriate device name (up to 6 characters). The name of the device should describe its intended mounting location or zone. Press OK. The display will show the device number and name for your verification. Mount the ISMV on the wall: > Follow the mounting rules on page. > Hold the ISMV base against the mounting surface and mark the appropriate mounting holes. > Drill pilot holes and install anchors where needed. > Place the base on mounting surface so that the pilot holes line up and secure base with appropriate screws. > Attach camera to base and secure with screw if required. 3 Press OK. The display shows FUNCTIONAL DEVICE TEST? Press YES again and verify IMV operation. The red LED indicates the detection field. 4 Press OK to end the detection test. 5 The display shows ADD A NEW DEVICE? Repeat steps -4 for remaining devices. 6 When finished, exit from configuration mode by pressing and holding the ESC/NO for 5 seconds.

Mounting recommendations Recommended mounting height is, m. There may be a m radius blind zone under the detector depending on the room size and detector installation height. Confirm the detection field using the functional device test. The ISMV is fitted with a 90 wide angle lens that allows the camera to cover the full size of the area to protect. It will reduce the blind area under the detector as well. Please mount the ISMV in an angle to optimize detection. It shall be mounted opposed to the access point or asset you need to protect. The detector should not be mounted close to a door or an access point. Such installation increase the probability of a missed intrusion. When stairs mounted, please aim the detector towards the entry or the exit of the stairwell. Detection diagram Streaming option The new ISMV MotionViewer allow the user to request a live video session. The ISMV is the first battery-powered wireless camera detector emitting on 868MHz able to provide a live video stream from its camera. The 868 MHz frequency has excellent range and allow for excellent battery-life. 3

Security notes / (FR) Notes de sécurité / (DE) Hinweise zur Sicherheit English Français Deutsch Remove the batteries before any maintenance! WARNING, there is a risk of explosion if a battery is replaced by an improper model! Observe polarity when setting up the batteries! Do not litter the batteries when they are used! Dispose of them properly according to Lithium Metal requirements Retirez les piles avant toute opération de maintenance! Attention! Il y a un risque d'explosion si la batterie utilisée est remplacée par un mauvais modèle! Respectez la polarité lors de la mise en place des piles! Ne jetez pas les batteries usagées! Ramenez-les à votre installateur ou à un point de collecte spécialisé. Batterien vor jeglichen Wartungsarbeiten entfernen! Vorsicht, es besteht Explosionsgefahr, wenn eine Batterie durch eine Batterie falschen Models ersetzt wird! Achten Sie beim Einsetzen der Batterien auf die Polung! Entsorgen Sie Batterien nicht im normalen Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterien zu den öffentlichen Sammelstellen. FCC Regulatory Information for USA and CANADA FCC Part 5. Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 5.05 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: > Reorient or relocate the receiving antenna. > Increase the separation between the equipment and receiver. > Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. > Consult the dealer or an experienced radio/tv technician for help. Radio frequency radiation exposure information according.09 /.093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 0 cm between the radiator and your body. Cet équipement est conforme aux limites d exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 0 cm de distance entre la source de rayonnement et votre corps. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 5 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s) Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes : L appareil ne doit pas produire de brouillage, et L utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement.. This symbol on the product or on its packaging indicates that this product should not be treated as household waste. It must be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health. The recycling of materials will help to conserve natural resources. For more information about recycling of this product, please contact your local municipality, your waste disposal service or the company that installed the product. The EC declaration of conformity of this product is available by flashing this QR code. 4

ELECTRICAL PROPERTIES Panel compatibility Streaming option Without streaming option Battery Nominal voltage Low battery treshold Estimated battery life Current consumption 3 CR3A 3V Lithium batteries 3 V.7 V 4 years Standby (h average) 00 µa Max RADIO PROPERTIES W panels XL, XLL, XT, XV, Visio and their variants 300 ma RF SView technology Radio type Spread spectrum RF bidirectional Operating frequency 868MHz - ISMV 00 (Europe, Africa, Asia) 95 MHz - ISMV 60 (USA, Canada, South america) 90 MHz -ISMV 70 (Australia, South america) Transmission security AES algorythm encryption Supervision Radio, batteries, tamper Radio antenna Integrated VIDEO PROPERTIES Camera Angle 90 Sensor type CMOS Lighted video Programmable : Color or B&W Night vision video Black & white automatic infrared Infrared illumination Automatic with IR LEDs Infrared illumination distance 7m Video Video format H64 (MPEG if not available) Framerate 5 images per second Resolution QVGA (30x40) Video file size Up to 30 kb DETECTION PROPERTIES Infrared detection specifications Technology Passive-infrared DSP Type Dual element sensor Lens Fresnel Detection angle 90 Detection range Up to 0m Initialization time 0 seconds Recovery time 90 seconds Tamper Tamper detection BOX Physical properties Material Environmental properties Operating temperature Max relative humidity Installation / Mounting Mounting height Wall mounting Box sealing Certification organisation : CNPP Cert. Route de La Chapelle Réanville CS65 F 7950 SAINT MARCEL Tel : +33(0).3.53.63.63 Fax: +33(0).3.53.64.46 Sites Internet : www.cnpp.com Email : certification@cnpp.com Cover and wall tamper, electromagnetic immunity STANDARDS AND APPROVALS ABS UL94-V0-0 /+55 C 75%, without condensing,0 m screws With screw 868 MHz ISMV 00 Compliant with annex IV from the R&TTE 999/5/CE directive NF&AP boucliers suivant le référentiel NF34-H58 Matériels de sécurité electronique, détection d intrusion DETECTEUR DE MOUVEMENT A INFRAROUGE PASSIF Marque commerciale Videofied Référence produits ISMV 00 N de certification 630000 NF EN503-- Grade 008 RTC 503-- 05 NF EN5030-4 0 NF EN5030-5 Environment Class II 0 Certification organisation : AFNOR Certification, rue François de Pressensé 9357 Saint Denis La Plaine Cedex Tel : +33(0).4.6.80.00 Fax: +33(0).49.7.90.00 Sites Internet : www.marque-nf.com E-mail : certification@afnor.org www.videofied.com 5