DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Similar documents
TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Changes to this Division since the last issuance are indicated with yellow highlighted text.

Card Access Control Specifications

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

SECTION INTRUSION DETECTION

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

Appendix 1 LACCD Districtwide Security Performance Requirements

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

UBC Technical Guidelines Section Edition Door Hardware Page 1 of 7

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

APPENDIX F: LOCKSETS AND ACCESS CONTROL

DESIGN GUIDELINES AND TECHNICAL STANDARDS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Access Control System - CAAMS. Basis of Design

CARD ACCESS CONTROL SYSTEM

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

ELECTRONIC SAFETY AND SECURITY SYSTEMS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

106. LOCK AND CARD ACCESS GENERAL DESIGN INFORMATION

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

USD 380 Centralia, Frankfort & Vermillion

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

16721 FIRE ALARM AND DETECTION SYSTEMS

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

OKLAHOMA STATE UNIVERSITY

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 28 ELECTRONIC SAFETY AND SECURITY

BSD Technical Standard. Division 28: Electronic Safety & Security

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

Architect s Specification Guideline:

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

FIRE ALARM AND DETECTION SYSTEMS

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

16721 FIRE ALARM AND DETECTION SYSTEMS

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

1. The fire detection and alarm system (including the conduit) shall be a separate bid item and not part of the general electrical contract.

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

Environmental Health & Safety

SECTION ADDRESSABLE FIRE ALARM SYSTEM

Wayne State University Police Department. Alarm/Card Access Specification s & Standards

RFP Addendum 2 March 31, 2016

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

SECTION : FIRE ALARM & DETECTION SYSTEMS

4. Hardware templates to fabricators of other work receiving electro-mechanical hardware.

STATEMENT OF WORK. System Description:

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION FIRE ALARM SYSTEMS

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

1.3 REFERENCE STANDARDS

System Design and Overview Document

/ How To Order

1. Buildings on the Pullman campus are monitored by a Simplex 4120 FDA Network or a Siemens XLS Network.

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Fire Alarm System Inspection and Testing Report

Pilfergard Door Alarms

SAFEPATH Mass Notification System (SPMNS)

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

ONYX FirstVision Specification Interactive Firefighters Display

SECTION FIRE DETECTION AND ALARM

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 28 Electronic Safety and Security 4600 Fire Detection and Alarm

July 14, 1999 DF C-100.

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Mircom FX /01/16

DIVISION 28 ELECTRONIC SAFETY AND SECURITY 2006 Edition, Published January 1, 2006 Division Revision Date: February 7, 2017

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

SECTION DOOR HARDWARE

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION FIRE DETECTION AND ALARM

TrueAlarm Fire Alarm Systems

University Design Standard Fire Alarm Systems

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Monarch Electrified Series

ONONDAGA COMMUNITY COLLEGE FERRANTE HALL RENOVATIONS - PHASE

SECTION FIRE ALARM SYSTEM PART 1 GENERAL

Brighton Area Fire Authority

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

University of Rochester October 17, 2008 Brooks Landing Business Center

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Specification/ Data Sheet

The following information shall become and form part of the contract documents.

Transcription:

281300 - ACCESS CONTROL A. General DIVISION 28 ELECTRONIC SAFETY AND SECURITY At the beginning of the project, schedule a meeting with the Facilities Access/Maintenance Coordinator with questions and concerns. B. Software 1. Lenel Onguard is utilized as the University s electronic access software. Communications Engineering Company (CEC) 319-294-9000 is the University s value added reseller and partner. All readers, door contacts, intrusion alarms, interface modules, configuration and programming should be provided through CEC. C. Exterior Doors 1. All doors that are on a schedule must be hard wired. No wireless allowed. 2. Exterior doors should be equipped with Von Duprin panic device hardware with QEL (Quiet Electronic Retraction), latch bolt monitoring and request-to-exit built in. No electric strike plates or PIR Request to Exit Motion Sensors. 3. All exterior doors must be hardwired back to the Lenel panel. Von Duprin 99 series rim panics exit device or mortise locks, on all exterior doors. 4. All doors that are normally locked 24/7 should only have position switches installed to ensure door is in the closed position. 5. Proximity readers should be installed at doors identified for after-hours access. One handicap entrance is to be identified for after-hours access. 6. For monitoring reasons, all exterior doors should have position switches. 7. All door that are monitored must have a closing device on door. 8. Interlock handicap operators with door access system to prevent operation if door is locked. 9. A Schlage AD-300 is an option, if an electrified mortise lock or panic device is not 1

feasible. D. Interior Doors 1. For monitoring reasons, all interior doors should have position switches installed. 2. No electric strike plates or PIR Request to Exit Motion Sensors, unless approved by Physical Plant Facilities Access Office. 3. All interior doors must be mortise locks. If using a panic device, it must be Von Duprin with QEL, latch bolt monitoring and request-to-exit built in. Must be hardwired back to Lenel panel. Electric strike maybe an option if doing an interior retrofit. This must be approved by Physical Plant Facilities Access Office. 4. Electrified mortise lock must have a door position switch and a request to exit included. 5. A Schlage AD-400 wireless, is an option, if an electronic hardwire lock is not feasible. Must be cleared by Physical Plant Facilities Access Office. E. Additional 1. All electronic locks on campus must have a Stanley Best Security Solutions (7 pin core) lock cylinder, for a key override. 2. All circuit boards must be in a panel box that is lockable. Before mounting a panel box in a data closet area, space must be approved by Physical Plant Facilities Access Office. 3. Readers must be a HID iclass SE R10 or R40 model, another option is a pin pad keypad reader. All readers must be mounted straight and level. Door contacts need to flush and match the color of the door frame as much as possible. Panic bar and request to exit need to be tight, straight and level. Card reader and keypad required for certain locations, verify with Owner. 4. Intelligent Dual Reader controller must be a Lenel LNL 2220 or LNL 1320. 5. If an electrified mortise lock or panic device is not feasible, Schlage AD-300 is an option. 6. Fail secure devices must be on all latching and locking devices. 2

7. The electronic door access system components should be on emergency power. Any telecommunications equipment that is required for connecting the electronic door access system to the campus network is also required to be on emergency power. 28 31 00 - FIRE ALARM SYSTEMS A. General 1. Design Requirements a) Meet current NFPA 72 (National Fire Alarm Code), NFPA 101 (Life Safety Code) ADA, UBC, Iowa State Building Code, paying particular attention to the Fire Safety Rules for School and College Buildings. b) Require strict compliance with audibility requirements. c) Owner desires to install analog type addressable systems in new buildings and major remodels in existing buildings. Smaller buildings and minor additions to existing systems may still be hard wired. Voice systems are also desired in most new construction. Discuss the basic system type with the Owner prior to design. 2. Materials a) University standard fire alarm control panel is Simplex 4100 Series. 3. Preferred Zoning/Annunciation: a) Addressable systems: 1) Annunciate each device or group of devices by room number and room function, on the LCD display. B. Fire Alarm Control Panel (FACP) 1. Power Supplies: a) Primary power source from normal 120 VAC building power with emergency generator backup if available. Secondary power source is an internal battery pack. b) Provide adequate internal power supply capacity for 25% future growth. c) Furnish a dedicated circuit for each fire alarm control panel. d) Provide a convenience receptacle, for service purposes, within 3 of the FACP. 2. Generally control panels should be located at the fire department attack entrance. Discuss locations with Owner s Representative. 3

3. Voice Systems: a) When voice systems are employed, use standard UNI message set with temporal code for evacuation. b) Discuss the use of messages and their method of initiation with the Owner s Representative prior to design. c) Voice systems to use 70 Volt Line. d) Provide one redundant back up audio amplifier for each system. e) Total amplifier power should be based on 4 watts per speaker location. f) Provide a microphone and audio switches at the FACP and at the attack entrance annunciator(s). C. Local alarm panel communication with campus emergency responders. 1. Owner has a Siemens Automation System (BAS) in most campus buildings. Discuss system availability and connection point location with Owner before fire alarm design. Owner prefers a stand alone fire alarm system in each building, with connection to the BAS system indicating: a) General alarm (device address when requested) b) System trouble c) Supervisory alarm (when used). d) Special alarms (when used). 2. Provide a ¾ conduit with cables, as required, between the FACP and the nearest building automation panel. D. Annunciator 1. Provide annunciator at fire department Attack entrance(s). LCD type preferred. Mount in shaded location so sunlight will not wash out LCD display. 2. Annunciator type, quantity and location(s) to be discussed with Owner s Representative at schematic design phase. Graphic annunciator panels will not be used. 3. Operating controls such as reset, acknowledge and smoke control accessible by key only. E. Auxiliary Systems 4

1. Fan shutdown equipment: a) Provide fan shutdown(s) where required by current codes. 2. Door holders: a) 24V 3. Smoke elimination: 4. Extinguishing Systems a) On Drawings show wiring between any extinguishing systems and the building fire alarm system as well as the contractor responsible for installation. F. Coiling Doors/Fire Curtains (Roll Up Metal Doors) 1. The use of this type door is strongly discouraged, and only by specific permission of the Owner s Representative. G. Wiring 1. Mark junction boxes and conduit by painting red. and stenciling FA on cover 2. Min. size # 18 AWG with larger sizes as needed, stranded wire allowed. Fire alarm cable to be plenum rated, even when used in non-plenum areas or in raceway. Type per Simplex approved list. 3. Complete raceway system required. H. Job Site Considerations 1. When working on operating fire alarm systems, only circuits(s) affected may be bypassed or disconnected and only during working hours. Panel must be operational at end of working hours. Disconnections and bypasses to be done only by Owner s Representative(s). 2. Detectors in construction areas to be Bagged during dust producing operations. Working detectors to be uncovered at end of working hours. I. Testing: 1. Start up and certification testing to be done by a qualified NICET certified fire alarm technician. Technician s name and certification number to appear on documents. 2. Acceptance testing to be witnessed by Owner s Representative. life safety technician. Owner to receive copies of all test results immediately upon completion, 100% of the devices must be tested. 5

3. Test in accordance with NFPA 72 Chapter 7. Provide documentation per 7-5. 4. All A/V devices must be uniquely identified with a bar code - Barcode Reader to be turned over to owner. 5. Walk test program to record/download test results must be included. Hardware and software to be turned over to the owner. 6