INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

Similar documents
Explosive atmospheres. IECEx. International Electrotechnical Commission

IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTRODUCTION

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

INTERNATIONAL STANDARD

IECEx Certificate of Conformity

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

IECEx Certificate of Conformity

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

IECEx Certificate of Conformity

This document is a preview generated by EVS

Australian/New Zealand Standard

Combustible Dusts What do I do???

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Australian/New Zealand Standard

Official Journal of the European Union

IECEx Certificate of Conformity

Not to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them?

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

IECEx Certificate of Conformity

INTERNATIONAL STANDARD

IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

IECEx Certificate of Conformity

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

IECEx Certificate of Conformity

IECEx Certificate of Conformity

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Changes to Certification and its Impact on Manufacturers. Des McDonell CSE-Ex Pty Ltd

IECEx Certificate of Conformity

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

INTERNATIONAL STANDARD

IECEx Certificate of Conformity

Legislation, Standards and Technology. IEC TC 41 Explosion protection of electrical equipment

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

IECEx Certificate of Conformity

UL HAZARDOUS LOCATIONS SERVICES

Australian/New Zealand Standard

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

OVERVIEW OF INDIAN HAZARDOUS LOCATION SYSTEM. By B K Gupta

Official Journal of the European Union

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

AS/NZS :2008

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

IECEx Certificate of Conformity

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Guide for hazardous areas

IECEx Certificate of Conformity

Guidelines for Analysis of Electromeric Sound Deadner (Under Seal) Silencer

IECEx Certificate of Conformity

IECEx Certificate of Conform ity

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

IECEx Certificate of Conformity

FLASHLIGHT ANSI STANDARDS

(German speaking trainers with English written slides)

FLASHLIGHT ANSI STANDARDS

Electrical Installations Design, Selection, Erection and Inspection

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

Disclosure to Promote the Right To Information

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Disclosure to Promote the Right To Information

srra, of Conformity IECEx Gert f cate ?-ot,b

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

IECEx Certificate of Conformity

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IECEx Certificate of Conformity

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

INTERNATIONAL STANDARD

IECEx Certificate of Conformity

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Title: ExTAG Industry Discussion Request Application of IEC Ed Section 16.6 Selection of suitable cable INTRODUCTION

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

IECEx Certificate of Conformity

INTERNATIONAL STANDARD

EMIRATES CONFORMITY ASSESSMENT SCHEME (ECAS): ECASEx COMPLIANCE

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

AS/NZS IEC :2015

Survey of electrical equipment installed in hazardous areas on tankers

Area Classification and Types of Protection for Explosive Atmospheres: A Review

Disclosure to Promote the Right To Information

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres?

S T R I T T & P R I E B E I N C.

Safety standards relevant to Refrigeration, Air-Conditioning and Heat Pump equipment

C 319/6 Official Journal of the European Union

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

IECEx Certificate of Conformity

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) To: Members of the Management Committee ExMC Introductory Note The Secretariat is pleased to advise that an application has been received from India for acceptance as a Participating Member within the IECEx Scheme. In accordance with IECEx 01, IEC Scheme for Certification to s relating to Equipment for use in Explosive Atmospheres (IECEx Scheme) Basic Rules - a copy of the application is attached for approval by the Ex Management Committee, ExMC. Therefore please consider the application and return the completed voting form to the Secretariat by 24 07 2006. You may return your vote via either fax or E-mail. Visiting address: s Australia Building 286 Sussex Street Sydney NSW 2000 Australia Contact Details: Tel: +61 2 8206 6940 Fax: +61 2 8206 6272 E-mail: chris.agius@iecex.com http://www.iecex.com Page 1 of 5

Mr C Agius Secretary ExMC 286 Sussex Street Sydney NSW 2000 Australia Tel: +61 2 8206 6940 Date: 18 Fax: +61 2 8206 6272 E-mail: chris.agius@iecex.com Reference: CMD III/ IEC Ex For the attention of the Secretary of the IEC Ex Management Committee Application to become a participating country in the Scheme of the IECEx for Certification to s for Electrical Equipment for Explosive Atmospheres (IECEx Scheme) The following application is made in accordance with Clause 7 and annex A of Publication IECEx 02: a) name of the country...india... b) name and address of the Member Body of the IECEx BUREAU OF INDIAN STANDARDS 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002 Phone: +91 11 23237481 Fax: +91 11 23231229 E-mail: ddgm@bis.org.in c) legal status of the Member Body of the IECEx within the country BUREAU OF INDIAN STANDARDS is the s Body of India, established under the Act of Parliament of India, (BUREAU OF INDIAN STANDARDS ACT, 1986) d) IEC standard(s) for which participation is sought (tick one or more for the following IEC standards): Number 60079-0 Electrical apparatus for explosive gas atmospheres Part 0: General requirements 60079-1 Electrical apparatus for explosive gas atmospheres Part 1: Flameproof enclosures d 60079-2 Electrical apparatus for explosive gas atmospheres Part 2: Pressurised enclosures 'p' 60079-5 Electrical apparatus for explosive gas atmospheres Part 5: Powder filling "q" 60079-6 Electrical apparatus for explosive gas atmospheres Part 6: Oil-immersion 'o' Page 2 of 5

60079-7 Electrical apparatus for explosive gas atmospheres Part 7: Increased safety 'e' 60079-11 Electrical apparatus for explosive gas atmospheres Part 11: Intrinsic safety 'i' 60079-15 Electrical apparatus for explosive gas atmospheres Part 15: Type of protection 'n' (Non-Sparking) 60079-18 Electrical apparatus for explosive gas atmospheres Part 18: Encapsulation 'm' 61241-1-1 Electrical apparatus for use in the presence of combustible dust Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus 61241-4 Electrical apparatus for use in the presence of combustible dust Part 4: type of protection pd 61779-1 Electrical apparatus for the detection and measurement of Part 1: General requirements and test methods 61779-2 Electrical apparatus for the detection and measurement of Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air 61779-3 Electrical apparatus for the detection and measurement of Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air 61779-4 Electrical apparatus for the detection and measurement of Part 4: Performance requirements for group II apparatus indicating up to 100% lower explosive limit 61779-5 Electrical apparatus for the detection and measurement of Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas e) the national standard(s) corresponding to the IEC standard(s) ticked off in d): Number 60079-0 Electrical apparatus for explosive gas atmospheres Part 0: General requirements IS 13346: 2004 60079-0(2000) 60079-1 Electrical apparatus for explosive gas atmospheres Part 1: Flameproof enclosures d IS 2148: 2004 60079-1(2001) 60079-2 Electrical apparatus for explosive gas atmospheres Part 2: Pressurised enclosures p IS 7389: 2004 60079-2(2001) Page 3 of 5

60079-5 Electrical apparatus for explosive gas atmospheres Part 5: Powder filling "q" 60079-6 Electrical apparatus for explosive gas atmospheres Part 6: Oil-immersion 'o' 60079-7 Electrical apparatus for explosive gas atmospheres Part 7: Increased safety 'e' 60079-11 Electrical apparatus for explosive gas atmospheres Part 11: Intrinsic safety 'i' 60079-15 Electrical apparatus for explosive gas atmospheres Part 15: Type of protection 'n' 60079-18 Electrical apparatus for explosive gas atmospheres Part 18: Encapsulation 'm' 61241-1-1 Electrical apparatus for use in the presence of combustible dust Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IS 7724: 2004 60079-5(1997) IS 7693: 2004 60079-6(1995) IS 6381: 2004 60079-7(2001) IS 5780: 2002 60079-11(1999) IS 8289:1976 Being harmonized with IEC 60079-15 IS 15451: 2004 60079-18(1992) 61241-4 Electrical apparatus for use in the presence of combustible dust Part 4: type of protection pd 61779-1 Electrical apparatus for the detection and measurement of Part 1: General requirements and test methods 61779-2 Electrical apparatus for the detection and measurement of Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air 61779-3 Electrical apparatus for the detection and measurement of Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air 61779-4 Electrical apparatus for the detection and measurement of Part 4: Performance requirements for group II apparatus indicating up to 100% lower explosive limit Page 4 of 5

61779-5 Electrical apparatus for the detection and measurement of Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas f) any national differences from the IEC standard(s) (use a separate page or pages if necessary to list national differences) No Differences. Please see e) for corresponding s which are identical to IEC s. IS 8289: 1976 Electrical equipment with type of protection n, is being revised to make it identical to IEC 60079-15. g) whether or not IECEx Certificates of Conformity are accepted in the country Will be accepted after India becomes member of IEC Ex Scheme. The IECEx Member Body undertakes to abide by the Rules and Procedures laid down in Publication IECEx 02 and to use its best endeavours to assist in the achievement of the aims and objectives of the IECEx Scheme Signature: Name: S. M. BHATIA Date: 18 Deputy Director General (Marks) Bureau of Indian s Page 5 of 5