Propane Fume Detection System

Similar documents
Propane Fume Detection System With Solenoid Valve Control

Propane Fume Detection System With Solenoid Valve Control

Deluxe Discharge Alarm

RV Carbon Monoxide Alarm

Marine Carbon Monoxide Alarm

CG2 & MA2 Series Clean Agent FE-241 & HFC-227ea Owner s Manual & Installation Instructions

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

BEP Marine Gas Detector FD-2

BEP Marine Gas Detector 600-GDRV

OPERATION, SERVICE & PARTS MANUAL

Owner Instructions. Warning! Read instructions before using the machine. Model: SSS 1500C Back Pack Vacuum

FW-RA-LED Remote Multiplex Annunciator Panels

IMPORTANT SAFETY INFORMATION:

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Controllers. Instruction Manual WARNING

OPERATION, SERVICE & PARTS MANUAL

Instruction Manual WARNING

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

Model # Airflow Monitor Warranty. Installation, Operation, Maintenance Manual. Analog Airfl ow Monitor Model Number #51403

Duct Mount. Installation Instructions

Panel Mounted Heat Exchangers by Dantherm, Inc.

COMBUSTIBLE GAS LEAK DETECTOR PEN

Owner s. Coolerr. comply. To view

OWNER'S MANUAL RSL MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local:

INSTALLATION AND INSTRUCTION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Murano Shower Cabin Installation Instruction

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

RK-05 Combustible Gas Transmitter Operator s Manual

Compressed Air Dryer

INSTALLATION, OPERATION AND MAINTENANCE

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

For use with models: BP , BP , BP

INSTALLATION AND OPERATING MANUAL

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

Macurco HD-11 Hydrogen Gas Detector

User s Manual and Operating Instructions

USER S OPERATING AND INSTRUCTION MANUAL

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

PM100/PM100E PLANTER MONITOR. Operator s Manual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

RK/ RK Combustible Gas Detector Operator s Manual

Protocol Station Remote Alarm

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

RK / RK Methane Detector Operator s Manual

Level Alarm Control. Blender Accessories U S E R G U I D E UGB

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

INSTALLATION AND OPERATING MANUAL

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Environmental Monitoring SmartSlot Card

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Installation and Operation Instructions 1000 Series Siren & Controller

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

RK Transmitter Technical Notice

INSTRUCTION MANUAL HS-229G

M1200 Series Limited Warranty Dependability Promise

RK Combustible Gas Transmitter Operator s Manual

Introduction... 1 System Overview... 1 System Diagram... 2

CD6102 / CD6102 OC / CD6102-2

Owner s. 18 Misting MF18W. To view

nova extreme retrofit High Output T5 Lighting Kit

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Installation & Operation Manual Ice Cream Freezers

Industrial Vacuums, Inc

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

RK Carbon Monoxide Transmitter Operator s Manual

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

PPI PPI PPI SERVICE PPI PPI PPI PPI PPI PPI CAUTION! PPI

OZX-300ST Ozone Generator

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

(HSTAT Series) Instruction Manual

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Owner's Manual RSL-2700 GRAPHIC LAMINATION PRODUCTS

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

User s Manual For Model Aero-551 (Rev. Orig.)

The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

RK-05 Carbon Monoxide Detector Operator s Manual

gamma pond Ultraviolet Sterilizers

CVS Model Inline Multi-Port Ventilators

OWNERS MANUAL MODEL 451 (-101 & -201)

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

OWNER'S MANUAL. RSL-2701U (for CANADA MODEL) RSL-2701S (for USA MODEL ) Royal Sovereign International Inc.

RK Carbon Monoxide Transmitter Operator s Manual

Single Station Remote Alarm

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

Transcription:

Propane Fume Detection System Single Channel Systems P-1B-R (Black, Round) P-1C-R (Chrome, Round) Owner s Manual & Installation Instructions Read and comply with all instructions, warnings and limitations before installing, servicing or removing this device. 1

Additional copies of this manual are available at no charge by contacting the manufacturer, distributor or dealer. Fireboy-Xintex reserves the right to change features without notice. General Information 3 Specifications 3 Operation of Xintex Propane Fume Detector(s) 4 Installation 6 Installing the Display Unit (P1BR-N01-D/P1CR-N01-D) 6 Routing Sensor Cable(s) (FS-X01 CABLE XX ) 6 Installing Propane Fume Sensor(s) (FS-T01) 6 Electrical Connections (P1BR-N01-D/P1CR-N01-D) 7 Testing the System Operation 7 Testing the Propane Fume Sensors 7 Maintenance 7 In the Event of an Alarm 8 Repairing Xintex Propane Detection Components 8 Returning Xintex Propane Detection Components 8 1 Year Limited Warranty 9 2

General Information WARNING PROPANE FUME DETECTORS ARE MEANT TO SERVE AS A SUPPLEMENTAL WARNING SYSTEM. IT IS NOT MEANT TO REPLACE STANDARD SAFETY PRACTICES WHICH SHOULD BE CARRIED OUT AROUND EXPLOSIVE GASES. The P-1B-R and P-1C-R Propane Fume Detectors are an effective means to monitor propane fumes in a compartment or leaking fuel systems. The system uses a sensor, located in a place of interest, and a central display unit that notifies you of the state of the system. Specification System Specifications (P-1B-R/P-1C-R) Operating Voltage: 9-30 VDC Nominal Current Draw: 55mA @ 12 VDC Maximum Current Draw: 95mA @ 9 VDC Operating Temperature: -40 F (-40 C) to 185 F (85 C) Alarm Horn: 68dB 3

Operation of Xintex Propane Fume Detector(s) There are 3 LEDs located on the Display Unit for each channel on the system. The Green LED, located at the top, indicates that the system is operational. The Yellow LED, located in the center, indicates that there is a Fault in the system. This is to notify the user to check the connections and wire runs of the sensors. There may be a break in the wiring or a disconnected sensor on that channel. The Red LED, located at the bottom, indicates a fume buildup of 20% of the LEL (Lower Explosive Limit) which is considered an alarm. The alarm horn will sound when the Red LED is illuminated. P1BR-N01-D P1CR-N01-D The alarm status will continue as long as the fume level remains at an elevated level. The alarm horn may be silenced by pressing the Check/Reset button. The alarm will reactivate after 30 seconds as long as the Detector remains in alarm status. The problem should never be considered corrected as long as the Red LED is illuminated. 4

FS-X01 CABLE XX FS-T01 P1BR-N01-D P1CR-N01-D RED Power (+) BLACK Ground (-) 1.0 Amp Fuse 5

Installation Installing the Display Unit (P1BR-N01-D/P1CR-N01-D) The Display Unit should be located at the instrument panel, so that the visible and audible indicators may be easily observed. Drill a 2-1/16 hole to accommodate the P1BR-N01-D/P1CR-N01-D Display Unit. Insert Display Unit into hole and secure with the provided threaded mounting nut. NOTE DO NOT MAKE ELECTRICAL CONNECTIONS AT THIS TIME. THEY WILL BE ADDRESSED IN A LATER SECTION. Routing Sensor Cable(s) (FS-X01 CABLE XX ) A 20 FT Sensor Cable is provided for each Propane Fume Sensor. The Sensor Cables should be routed starting at the Display Unit, then to the pre-determined location of the Propane Fume Sensor. Connect to the Display Unit using the attached quick-disconnect connectors. Take care not to pinch, break, or cut the Sensor Cable or put too much stress on the connectors while routing the cable. Secure the Sensor Cable with the appropriate hardware for the application. NOTE DO NOT CUT EXTENSION CABLE FOR ANY PURPOSE. DOING SO VOIDS THE PRODUCTS WARRANTY. LONGER CABLES ARE AVAILABLE FROM 20 FT TO 100 FT. Installing Propane Fume Sensor(s) (FS-T01) The Propane Fume Sensor should be located by the propane powered appliance, near the floor. Avoid areas where damage may take place due to cleaning, mopping, kicking, or other physical damage. Harsh chemicals should not be used to clean sensors. Use the appropriate #8 mounting hardware to mount the Propane Fume Sensor in the desired location. The rubber gasket should be installed between the sensor and the mounting surface. Connect to the Extension Cable using the attached quick-disconnect connectors. 6

Installation Continued Electrical Connections (P1BR-N01-D/P1CR-N01-D) The Display Unit operates on 9-30 VDC. A Red and a Black 16 GA wire are provided for connecting to the power source. Connect the Red wire to Power (+) with an inline 1.0 Amp fuse. Connect the Black wire to Ground (-). NOTE IMPROPER CONNECTIONS WILL DAMAGE THE DISPLAY UNIT AND WILL VOID WARRANTY. Testing the System Operation The Propane Fume Detectors can be tested by pressing the Check/Reset button on the face of the Display Unit. The Display Unit will cycle through the LEDs and the alarm horn will activate while the LEDs cycle. Unplug the Propane Fume Sensor from each channel of the Detection System. The Yellow Fault LED should illuminate. If the Yellow LED does not illuminate, remove Display Unit and return direct to manufacturer following the instructions at the back of this manual. Testing the Propane Fume Sensors WARNING DO NOT USE A PROPANE SOAKED RAG OR A PARTIALLY FULL CONTAINER OF PROPANE TO TEST A SENSOR. THE RAW PROPANE COULD IGNITE, RESULTING IN SERIOUS INJURY. Test the Sensors by holding a Butane lighter to the sensor. Within a few seconds, the Red Danger LED should illuminate and the alarm horn will sound. Remove the lighter from the Sensor and mute the alarm horn. After approximately one minute, the Red LED will shut off. Maintenance The system should be tested periodically in the fashion described in the previous sections. Due to the harsh environmental conditions in marine applications, it is recommended to replace the Propane Fume Sensors every 3-4 years. 7

In the Event of an Alarm Immediately have all passengers and crew exit the passenger compartment and vessel if possible. Ventilate the space being monitored. Carefully check all fuel lines and other potential sources of propane fume leaks. If leaks are identified, shut off fuel supply and make any necessary repairs. Repairing Xintex Propane Fume Detection Components Xintex Propane Fume Detection Components are not field serviceable. Components must be returned to the factory for any repairs. Returning Xintex Propane Detection Components No product may be returned for credit or repair without a written Returned Material Authorization (RMA) form. Purchaser must call or email Fireboy-Xintex 616-735-9380 or fireboy@fireboy-xintex.com for a RMA. If due to extenuating circumstances a product is to be returned, after approval it must be received in 100% new/resalable condition. Products stored by the buyer for more than 26 weeks may not be returned for any reason. Maintaining fresh and current inventory is the responsibility of the buyer. 8

1 Year Limited Warranty This Warranty is in lieu of all other expressed or implied Warranties Seller warrants title, materials, and workmanship on equipment, except components manufactured by others for which the Seller assigns, as permitted, the original manufacturer s warranty. Seller s warranty shall be for a period of (1) one year from the date of sale to the ORIGINAL CONSUMER PURCHASER, during which non-conforming equipment returned to the Seller at Buyer s expense and risk, be repaired or replaced at the Seller s option. Fireboy-Xintex, Inc. will repair or replace products found to be defective in materials or workmanship within the period set forth above, provided that: (a) the product has not been subjected to abuse, contamination, neglect, accident, incorrect wiring not our own, improper installation or servicing, or used in violation of instructions furnished by Fireboy-Xintex, Inc. and (b) as to any prior defects in materials or workmanship covered by this warranty, the product has not been repaired or altered by anyone except Fireboy-Xintex, Inc and (c) the serial number has not been removed, defaced or otherwise changed, and (d) examination discloses, in the judgment of Fireboy-Xintex, Inc., does not assume the costs of removal and/or installation of the product or any other incidental costs of removal and/or installation of the product or any other incidental costs which may arise as a result of any defect in material or workmanship, and (e) upon discovery of defect, Buyer shall immediately cease use of and notify Fireboy-Xintex, Inc. Any warranty implied by law, including warranties of merchantability or fitness, is in effect only for the duration of the expressed warranties set forth above, no person is authorized to give any other warranty, or to assume for Fireboy-Xintex, Inc. any other liability in connection with the sale of its products; Fireboy-Xintex, Inc. shall not be liable for the loss of use, revenue, or profit or for any injury, or for any other consequential or incidental damages, buyer is not relying on seller s judgment regarding his or her particular requirements, and has had an opportunity to inspect the product to his or her satisfaction. This warranty gives you specific legal rights, and you may also have other rights, which vary, from state to state. www.fireboy-xintex.com Fireboy-Xintex, Inc. O-379 Lake Michigan Dr. NW Grand Rapids, MI 49534 fireboy@fireboy-xintex.com Phone (616) 735 9380 Fireboy-Xintex, LTD 10 Holton Road, Holton Heath Trading Park Poole Dorset BH16 6LT UK fireboyeu@fireboy-xintex.com Phone 44 (0) 845 9462 9