Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Similar documents
Software Version 2.01 LEVEL MONITOR MODEL 220

Level Measurement Continuous level measurement - Ultrasonic transmitters

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Annubar Flowmeter Series

Mobrey MCU900 Series Universal Control Unit

APPLICATION DATA SHEET

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Continuous level measurement Ultrasonic transmitters

TX6831 Data Sheet. Features. Benefits

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Process Alarm Module RTA 421

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 7000 Fixed gas detector

UDC100 Universal Digital Controller Specifications

Dissolved Oxygen Measurement liquisys M COM 223 / 253

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Rosemount 3490 Series

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Instruction Manual Model A

IGD.CO.UK

LC1350 Level Controller

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

RT FLOW RATE TOTALISER

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

DIGITAL METERS Large Display Temperature Meters Instruction Manual

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

APPLICATION DATA SHEET

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

2-wire Passive Intelligent Loop (LED) Display Meter

Level Measurement Continuous level measurement Ultrasonic transmitters

Ultrasonic Point Level Switches

LEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS. DATASHEET F170 - LEVEL MONITOR

Model 144H. Product Data Sheet , Rev DB February Content

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

2-wire Passive Intelligent Loop (LED) Display Meter

4) Intrinsic Safety Certification

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

INSTRUCTION MANUAL (ATEX)

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

FAHM Co. Temperature Transmitter PTT74 Series

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

DB5 Intrinsically Safe Sounder Type DB-5

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Process & TeMPerATUre UniversAl input DigiTAl MeTers

/8 DIN Level Indicator

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

I/A Series 716C 1/16 DIN Temperature Controller

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SUPREMATouch. Modular Fire & Gas Detection System

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Ultrasonic Switches. Features & Benefits

Specifications - Installation and Operating Instructions 2X 1/2 NPT OR M20 ELECTRICAL ENTRY. 3/4 NPT or 3/4 BSPT 5/8 [15.88]

OilSET-1000 (12 VDC)

WH EN IGH T T C LO SED

EXA Conductivity & Resistivity Analysers

Dräger PointGard 2100 Detection of toxic gases and vapours

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Low Temperature Zirconia Oxygen Analyzer

SET-2000 Hi Level/Oil

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Watchdog Elite Watchdog Elite BRAIME Product Information Bucket Elevator & Conveyor Hazard Monitor

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

SUPREMATouch. Modular Fire & Gas Detection System

Dräger Polytron 5100 EC Detection of toxic gases and vapors

EasyLog Data Logger Series

INTRODUCTION / TABLE OF CONTENTS

Toroidal Conductivity Transmitters Series APT4000 Specifications

Rosemount 3100 Series Ultrasonic Level Transmitters

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Pump-Up Controller MODEL 4062

Nov 08 PRODUCT SPECIFICATION SHEET

EasyLog Data Logger Series

Rosemount 4500 Hygienic Pressure Transmitter

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

SET-2000 Oil/Sludge 12 VDC

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

UDC 700 Universal Digital Controllers and Indicator Specifications

Pump-Down Controller MODEL 4052

Rosemount 3100 Series Ultrasonic Level Transmitters

Instrumentation Products and Applications

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

BA374C Intrinsically safe field mounting indicating temperature transmitter

Non-Contacting Point Level Detection and Pump Control Sensor. Setting a New World Standard

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Inductive slot sensor

eed quality electronic design USER s MANUAL

Laser Level Measurement Products. Introducing the New LLT100

Technical Data. Dimensions

PARTICULATE EMISSION MONITORING

Toxic Gas Detection. Model F12. Toxic Gas Detection

Transcription:

Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com

Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display Tank contents display Density correction Intrinsically safe Watertight to IP67 (Nema 4X) Wall, pipe and panel mounting CE compliant The Model 220 Level Monitor accepts a 4-20mA signal from a wide range of level sensors, including pressure transmitters, ultrasonic sensors or capacitance probes, and displays both level and tank contents on a large LCD display. Solid state relay outputs provide up to four level alarms and a 25 point non-linearity correction table allows the instrument to be programmed to fit most tanks. The Level Monitor is powered entirely from the 4-20mA current loop and, therefore, requires no external power or batteries. The instrument is fully programmable with setup parameters such as span, offset, alarm levels, etc, stored in a non-volatile memory which will retain all data for more than 10 years without power. The Model 220 is housed in an attractive IP67 (Nema 4X) polycarbonate enclosure which is completely watertight. A wall mounting bracket is supplied as standard, while a 2" pipe mounting bracket is available as an option. Alternatively, the Model 220 can be supplied as a panel mount instrument.

Level Monitor Displays measured level as a percentage (0-100%). Relays are programmable to alarm in either mode. 7 digit numeric display of contents with programmable span. An offset can be programmed to account for contents remaining in the tank when the measured level is 0%. The contents are displayed with 42 digit resolution so that larger values are displayed with trailing zeros (for example, 1437765 would be displayed as 1437700 and 5467289 would be displayed as 5467000). A programmable filter will filter out fluctuations in readings caused by agitation in the tank. Density correction is provided for level devices which are density sensitive. Should the density change, a correction factor can be programmed via the front panel. Four solid state opto-isolated dc relays arranged as high-high, high, low and low-low. An optional DIN rail mounted relay module is available which incorporates mains operated relays. A 25 point non-linear correction table can be programmed to handle any shaped tank. Up to 25 points on both the x and y axis can be programmed and the Model 220 will perform linear interpolation between points. The curve enables the contents of vessels, such as cylindrical tanks, bullet shaped tanks or hoppers to be displayed directly in engineering units as a volume or mass. A conversion program which runs under Windows 95 is available to calculate theoretical values for the conversion program based on tank dimensions. A DIN rail mounted module is available as an option which provides: 24Vdc at 50mA max for powering the 4-20mA current loop. Four relays rated at 240Vac, 3A max. The module is designed such that it can be mounted remotely from the Model 220, but easily wired to the instrument. Alarms can be programmed for continuous operation or for an Acknowledge mode of operation where the Display key is pressed to acknowledge and cancel the relay alarm output. The Model 220 is certified as intrinsically safe to European ATEX standards, and CSAUS/C standards covering both the USA and Canada.

LCD. 20 segment bar graph. 0...100% proportional to input signal. For non-inverting tanks 0% is 4mA and 100% is 20mA. For inverting tanks 0% equals 20mA and 100% is 4mA. 7 digits with 12mm (0.48") high digits on the LCD. Contents are displayed with 42 digit resolution and trailing zeros. The contents span is programmable in the range of 0.001...9,999,999 and can be any unit of measure. The contents zero is programmable in the range of 0.000...9,999,999. The contents zero is the contents in the tank at 0% level. Operating temperature: -20 C to 60 C. 98mm (3.9") (h) x 152mm (6.0") (w) x 43mm (1.7") (d) (cable glands not included). Sealed to Nema 4X or IP67 standards. Wall: Universal mounting bracket supplied as standard. Pipe: A galvanised metal bracket is available which enables the Model 220 to be attached to a 2" vertical or horizontal pipe. Panel: Supplied with mounting brackets. Terminals accessible from rear. ( Decimal point position for contents is programmable in range of 0...3 decimal point places. 0.05% of span. 0.05% of span @ 25 C. 0.1% (typ) of span, full temperature range. 0.5 second. Two wire. 2.5 volts maximum. ATEX Type II 2G EEx ia IIB T4. CSAUS/C Type Class 1, Groups C & D. Ui = 28V max Ii = 93mA max Pi = 653mW max Ui = 28V max Ii = 93mA max Pi = 653mW max Four open collector outputs suitable for driving DC solenoids or external relays. The outputs provide high, high-high, low and low-low flow alarms. "on" state. 200mA. 30 Vdc maximum. 0.8 Vdc typical across the output in the Outputs are separately opto-isolated. 1 Low-low Alarm (-) 2 Low-low Alarm (+) 3 4-20mA (-) Input 4 4-20mA (+) Input 5 Low Alarm (-) 6 Low Alarm (+) 7 High Alarm (-) 8 High Alarm (+) 9 High-high Alarm (-) 10 High-high Alarm (+)

The Model RPS24 Relay & Power Module is a DIN rail mounted module that provides a 24 Vdc loop power supply which can be used to power both the transmitter and Model 220. In addition, the RPS24 has four electromechanical relays which can be connected directly to the open collector outputs in the Model 220 to provide switchable ac outputs. 24 Volts dc. 50mA maximum. 250 Vac, 30 Vdc max. 3A max. 80mm H x 107mm D x 40mm W. 3.1" H x 4.2" D x 1.6" W. Intrinsic Safety i Intrinsically safe Not intrinsically safe Enclosure 0 Wall Mounting (no gland holes) and Mounting 1 Pipe Mount 2 Wall Mounting (Standard glands) 6 Pipe Mount Hazardous C CSA US and Canadian Approval Approvals M ATEX Approval S SAA Australian Approval No Approvals Typical Part Number: 220i.0C Riverside, Canal Road, Sowerby Bridge West Yorkshire HX6 2AY, UK Tel: +44 1422 829 940 Fax: +44 1422 829 941 Email: sales@contrec.co.uk 916 Belcher Drive, Pelham, AL 35124 USA Tel; (205) 685 3000 Fax; (205) 685 3001 Email; contrec@contrec-usa.com 5 Norfolk Ave, Ringwood, Vic 3134 Melbourne, AUSTRALIA Tel; + 61 413 505 114 Email; pchaston@optusnet.com..au 220 DS - 11/13